• 제목/요약/키워드: seismic code

검색결과 672건 처리시간 0.023초

중공단면 고강도 철근 콘크리트 교각의 연성거동에 관한 실험적 연구 (Ductility performance of hollow-section reinforced concrete piers using high-strength reinforcing bars)

  • 오병환;박대균;조근호;신용석
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.730-733
    • /
    • 2004
  • Three Hollow RC piers were tested under a constant axial load and a cyclically reversed horizontal loadto investigate the structural behavior of hollow RC piers using the high strength concrete and the high strength rebars. The test variables include concrete compressive strength, steel strength, and steel ratio. The test results indicate that RC piers using the high strength concrete and high strength rebars exhibit ductile behavior and appropriate seismic performance, in compliance with the design code. The present study allows more realistic application of high strength rebars and concrete to RC piers, which will provide enhanced durability as well as more economy.

  • PDF

벽식 노후 공동주택의 내진성능평가에 관한 연구 (Study on Seismic Performance Evaluation of Existing Apartment with Wall Type)

  • 정철화;정란
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.52-55
    • /
    • 2004
  • Before incorporating the earthquake-resistance design in design code(998), most of existing residential buildings were built without having lateral resistance capacity in addition to their structural peculiarity such as exterior stair ways, exterior elevator room. For these reasons, the retrofitting research demands for existing buildings arise recently and many retrofitting methods are proposed. These tasks are important to reduce the enormous economic loss and environmental issues. In this study, Scaled residential buildings with/without lateral resistance were tested and monitored with external lateral load especially toward the longer side of the building. From these experiments, enhanced retrofitting methods of old shear wall system are proposed and also compared with structural analysis.

  • PDF

Calibration of model parameters for the cyclic response of end-plate beam-to-column steel-concrete composite joints

  • Nogueiro, Pedro;da Silva, Luis Simoes;Bento, Rita;Simoes, Rui
    • Steel and Composite Structures
    • /
    • 제9권1호
    • /
    • pp.39-58
    • /
    • 2009
  • Composite joints, considering the composite action of steel and concrete, exhibit, in general, high strength and high ductility. As a consequence, the use of this type of joint has been increasing in many countries, especially in those that are located in earthquake-prone regions. In this paper, a hysteretic model with pinching is presented that is able to reproduce the cyclic response of steel and composite joints. Secondly, the computer implementation and adaptation of the model in a spring element within the computer code Seismosoft is described. The model is subsequently calibrated using a series of experimental test results for composite joints subjected to cyclic loading. Finally, typical parameters for the various joint configurations are proposed.

Seismic behavior of post-tensioned precast reinforced concrete beam-to-column connections

  • Cheng, Chin-Tung
    • Computers and Concrete
    • /
    • 제5권6호
    • /
    • pp.525-544
    • /
    • 2008
  • In this research, the self-centering effect in precast and prestressed reinforced concrete structures was investigated experimentally. The reinforced concrete beams and columns were precast and connected by post-tensioning tendons passing through the center of the beams as well as the panel zone of the connections. Three beam-to-interior-column connections were constructed to investigate parameters such as beam to column interfaces (steel on steel or plastic on plastic), energy dissipating devices (unbonded buckling restrained steel bars or steel angles) and the spacing of hoops in the panel zone. In addition to the self-centering effect, the shear strength in the panel zone of interior column connections was experimentally and theoretically evaluated, since the panel zone designed by current code provisions may not be conservative enough to resist the panel shear increased by the post-tensioning force.

철근콘크리트 구조물의 성능기반 평가방법 (Methodology for Performance_Based Evaluation of a RC Structure)

  • 이도형
    • 공학논문집
    • /
    • 제8권1호
    • /
    • pp.5-11
    • /
    • 2006
  • In order to evaluate the seismic performance of a reinforced concrete building structure, four different analyses are carried out. Firstly, conventional pushover analysis with code-specified inverted triangular load pattern is conducted. Secondly, the pushover analysis with uniform load pattern is performed. Thirdly, adaptive pushover analyses with spectral amplification for both EC 8 artificial and Northridge earthquake are carried out. Lastly, Incremental dynamic analyses under a number of scaled PGA for both EC 8 artificial and Northridge earthquake record are performed. Comparative studies demonstrate that the adaptive pushover analysis may be able to explain the response characteristics that conventional pushover analysis with fixed load distribution fails to capture.

  • PDF

비내진 상세를 가진 10층 철근 콘크리트 조적채움 골조의 일방향 가력 실험 (Push-Over Test of A 10-Story Reinforced Concrete Masonry Infilled Frame with Nonseismic Details)

  • 이한선;김정우;김상호
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 봄 학술발표회 논문집(I)
    • /
    • pp.513-518
    • /
    • 1999
  • The objective of this experiment is to observe the elastic and inelastic behaviors of high-rise reinforced concrete frame with infilled masonry. To do this a building frame designed according to Korean seismic code and detailed in the Korean conventional manner was selected. An 1:12 scale plane masonry-infilled frame model was manufactured according to similitude law. Push-over test were performed under the roof displacement control. To simulate the earthquake effect, the lateral force distribution was maintained to be an inversed triangular by using whiffle tree. From the tests, story displacements, lateral story forces, local plastic rotations and the relations between inter-story drift versus story shear are obtained. Based on the test results, conclusions on the characteristics of the elastic and inelastic behaviors of a high-rise reinforced concrete frame with infilled masonry are drawn.

  • PDF

뉴질랜드 기준에서의 제한된 연성의 RC 구조물 내진 상세설계 (Seismic Details of Reinforced Concrete Structures of Limited Ductility in New Zealand Standard)

  • 이한선;유은진;우성우
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 가을 학술발표회논문집(I)
    • /
    • pp.229-234
    • /
    • 2000
  • As the level of earthquake intensity in Korea is considered to be moderate, some structures or structural elements may be subjected to the reduced ductility demand, in contrast to the structures in high seismicity, due to the large inherent strength induced by gravity loads. New Zealand Standard(NZS) deals with there structures within the category of structures of limited ductility. This paper briefly reviews the applicability of the code, regarding limited ductility, for frame strucures which are commonly used as the office building structural system. The difference of the loading condition is considered. Details of the plastic hinge region are compared between NZS and Korean standard.

  • PDF

청소로봇이 부착된 커튼월 부재의 구조해석 (The Structural Analysis of the Curtain Wall System for the Attached Cleaning Robot)

  • 한유길;이용원;연규원;김종;서상교
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2011년도 추계 학술논문 발표대회
    • /
    • pp.197-198
    • /
    • 2011
  • Most of buildings' exterior walls are curtain wall systems and in the respect, the cleaning robot system is the main research item for cleaning and maintenance of them. We have structurely analysed the cases to review on the structural stability of the mullion members where the cleaning robot is attached. The result is showing that the largest stress is formed by the basic wind speed, which is specified in Korean Building Code-Structural.

  • PDF

Effects of confinement reinforcement and concrete strength on nonlinear behaviour of RC buildings

  • Yon, Burak;Calayir, Yusuf
    • Computers and Concrete
    • /
    • 제14권3호
    • /
    • pp.279-297
    • /
    • 2014
  • This paper investigates the effects of confinement reinforcement and concrete strength on nonlinear behaviour of reinforced concrete buildings (RC). For numerical application, an eleven-storey and four bays reinforced concrete frame building is selected. Nonlinear incremental static (pushover) analyses of the building are performed according to various concrete strengths and whether appropriate confinement reinforcement, which defined in Turkish seismic code, exists or not at structural elements. In nonlinear analysis, distributed plastic hinge model is used. As a result of analyses, capacity curves of the frame building and moment-rotation curves at lower end sections of ground floor columns are determined. These results are compared with each other according to concrete strength and whether appropriate confinement reinforcement exists or not, respectively. According to results, it is seen that confinement reinforcement is important factor for increasing of building capacity and decreasing of rotations at structural elements.

초고층 건물골조 시스템의 내진설계상 문제점 (Problems in Seismic Design of High-Rise RC Building Frame Systems)

  • 이한선;정성욱;고동우
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2005년도 학술발표회 논문집
    • /
    • pp.195-202
    • /
    • 2005
  • High-rise residential buildings in these days tend to adopt a building frame system as primary earthquake resisting structural system for some architectural reasons. But there exist several ambiguities in designing such building frame systems according to current codes, with regards to : the effective stiffness property of RC cracked section in static and dynamic analyses, analytical model to evaluate story drift ratio and, deformation compatibility requirements of frames. The comparative study for these issues by appling IBC 2000 and KBC 2005 to a typical building frame system shows that demands of member strength and story drift ratio can be different significantly depending on designer's interpretation and application of code requirements.

  • PDF