• 제목/요약/키워드: seismic bearing

검색결과 509건 처리시간 0.023초

Seismic response variation of multistory base-isolated buildings applying lead rubber bearings

  • Islam, A.B.M. Saiful;Al-Kutti, Walid A.
    • Computers and Concrete
    • /
    • 제21권5호
    • /
    • pp.495-504
    • /
    • 2018
  • The possibility of earthquakes in vulnerable regions indicates that efficient technique is required for seismic protection of buildings. During the recent decades, the concept is moving towards the insertion of base isolation on seismic prone buildings. So, investigation of structural behavior is a burning topic for buildings to be isolated in base level by bearing device. This study deals with the incorporation of base isolation system and focuses the changes of structural responses for different types of Lead Rubber Bearing (LRB) isolators. A number of sixteen model buildings have been simulated selecting twelve types of bearing systems as well as conventional fixed-base (FB) scheme. The superstructures of the high-rise buildings are represented by finite element assemblage adopting multi-degree of freedoms. Static and dynamic analyses are carried out for FB and base isolated (BI) buildings. The dynamic analysis in finite element package has been performed by the nonlinear time history analysis (THA) based on the site-specific seismic excitation and compared employing eminent earthquakes. The influence of the model type and the alteration in superstructure behavior of the isolated buildings have been duly assessed. The results of the 3D multistory structures show that the lateral forces, displacement, inertia and story accelerations of the superstructure of the seismic prone buildings are significantly reduced due to bearing insertion. The nonlinear dynamic analysis shows 12 to 40% lessening in base shear when LRB is incorporated leading to substantial allowance of horizontal displacement. It is revealed that the LRB isolators might be potential options to diminish the respective floor accelerations, inertia, displacements and base shear whatever the condition coincides. The isolators with lower force intercept but higher isolation period is found to be better for decreasing base shear, floor acceleration and inertia force leading to reduction of structural and non-structural damage. However, LRB with lower isolator period seems to be more effective in dropping displacement at bearing interface aimed at reducing horizontal shift of building structure.

Seismic performance evaluation of RC bearing wall structures

  • Rashedi, Seyed Hadi;Rahai, Alireza;Tehrani, Payam
    • Computers and Concrete
    • /
    • 제30권2호
    • /
    • pp.113-126
    • /
    • 2022
  • Reinforced concrete bearing walls (RCBWs) are one of the most applicable structural systems. Therefore, vulnerability analysis and rehabilitation of the RCBW system are of great importance. In the present study, in order to the more precise investigation of the performance of this structural resistant system, pushover and nonlinear time history analyses based on several assumptions drawing upon experimental research were performed on several models with different stories. To validate the nonlinear analysis method, the analytical and experimental results are compared. Vulnerability evaluation was carried out on two seismic hazard levels and three performance levels. Eventually, the need for seismic rehabilitation with the basic safety objective (BSO) was investigated. The obtained results showed that the studied structures satisfied the BSO of the seismic rehabilitation guidelines. Consequently, according to the results of analyses and the desired performance, this structural system, despite its high structural weight and rigid connections and low flexibility, has integrated performance, and it can be a good option for earthquake-resistant constructions.

Probabilistic analysis of seismically isolated elevated liquid storage tank using multi-phase friction bearing

  • Moeindarbari, Hesamaldin;Malekzadeh, Masoud;Taghikhany, Touraj
    • Earthquakes and Structures
    • /
    • 제6권1호
    • /
    • pp.111-125
    • /
    • 2014
  • Multiple level performance of seismically isolated elevated storage tank isolated with multi-phase friction pendulum bearing is investigated under totally 60 records developed for multiple level seismic hazard analysis (SLE, DBE and MCE). Mathematical formulations involving complex time history analysis have been proposed for analysis of typical storage tank by multi-phase friction pendulum bearing. Multi-phase friction pendulum bearing represent a new generation of adaptive friction isolation system to control super-structure demand in different hazard levels. This isolator incorporates four concave surfaces and three independent pendulum mechanisms. Pendulum stages can be set to address specific response criteria for moderate, severe and very severe events. The advantages of a Triple Pendulum Bearing for seismic isolation of elevated storage tanks are explored. To study seismic performance of isolated elevated storage tank with multi-phase friction pendulum, analytical simulations were performed with different friction coefficients, pendulum radii and slider displacement capacities.

납-고무베어링을 적용한 제어장비의 동적 특성평가 (Dynamic Property Evaluation of Control Equipment using Lead Rubber Bearing)

  • 이경진;김갑순;서용표
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2002년도 추계 학술발표회 논문집
    • /
    • pp.341-348
    • /
    • 2002
  • In these days, The base isolation system is often used to improve the seismic capacity of the structures instead of conventional techniques of strengthening the structural members. The purpose of this study is to evaluate dynamic property evaluation of control equipment using lead Lead Rubber Bearing. In this study, a base isolation test of seismic monitoring control cabinet with LRB(lead rubber bearing) was performed. The cabinet will be installed on access floor in MCR(main control room) of nuclear power plant. Details and dynamic characteristics of the access floor were considered in the construction of testing specimen. N-S component of El Centre earthquake was used as seismic input motion. Acceleration response spectrums in the top of cabinets showed that the first mode frequency of cabinet with LRB(lead rubber bearing) was shifted to 7.5 Hz in compared with 18Hz of cabinet without LRB and the maximum peak acceleration was reduced in a degree of22 percent from 2.35 g to 1.84 g

  • PDF

지진시 저층건물 면진구조의 동적 거동해석 (Dynamic Analysis of Base-Isolated Low-level Structures Under Earthquake Excitation)

  • 문병영;강경주;강범수;김계수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집B
    • /
    • pp.448-453
    • /
    • 2001
  • This paper presents an analytical evaluation of the effect of motion on seismic responses of base isolated low-level building and experimental studies to evaluate isolation performances of a rubber bearing. Dynamic responses induced by earthquake were evaluated by response analyses, taking the rubber bearing of the base isolation devices into account. In the experiment, vibration tests were carried out using a model for rubber bearings as isolation devices against earthquake in order to investigate the isolation performances of the rubber bearings. Several kinds of rubber bearing for base isolated low-level building against earthquake are examined. As a result, it is shown that the effect of the motion on the response of the building and the base response is well controlled from a seismic design standpoint.

  • PDF

납고무받침 면진장치와 마찰진자 면진장치에 의한 트러스-아치 구조물의 지진거동 비교 (The Seismic Behavior of the Truss-Arch Structure by Lead Rubber Bearing and Friction Pendulum System with Seismic Isolation)

  • 김기철;석근영;강주원
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2008년도 정기 학술대회
    • /
    • pp.374-379
    • /
    • 2008
  • The purpose of seismic isolation system among them is to lengthen the period of structure and make its period shift from the dominant period of earthquake. In this study, the seismic behavior of arch structure with lead rubber bearing(LRB) and friction pendulum system(FPS) is analyzed. The arch structure is the simplest structure and has the basic dynamic characteristics among large spatial structures. Also, Large spatial structures have large vertical response by horizontal seismic vibration, unlike seismic behavior of normal rahmen structures. When horizontal seismic load is applied to the large spatial structure with isolation systems, the horizontal acceleration response of the large spatial structure is reduced and the vertical seismic response is remarkably reduced.

  • PDF

납-고무 받침에 의해 면진된 원전구조물의 응답에 대한 Bouc-Wen 모델 및 지진특성의 영향 (Effect of Bouc-Wen Model and Earthquake Characteristics for Responses of Seismically Isolated Nuclear Power Plant by Lead-Rubber Bearing)

  • 송종걸;손민균
    • 한국지진공학회논문집
    • /
    • 제21권2호
    • /
    • pp.95-103
    • /
    • 2017
  • In order to modeling seismic isolation system such as lead-rubber bearing (LRB), bilinear model is widely used by many researchers. In general, an actual force-displacement relationship for LRB has a smooth hysteretic shape. So, Bouc-Wen model with smooth hysteretic shape represents more accurately actual hysteretic shape than bilinear model. In this study, seismic responses for seismically isolated nuclear power plant (NPP) with LRB modelled by Bouc-Wen and bilinear models are compared with those of NPP without seismic isolation system. To evaluate effect of earthquake characteristics for seismic responses of NPP isolated by LRB, 5 different site class earthquakes distinguished by Geomatrix 3rd Letter Site Classification and artificially generated earthquakes corresponding to standard design spectrum by Reg. Guide 1.60 are used as input earthquakes. From the seismic response results of seismically isolated NPP, it can be observed that maximum displacements of seismic isolation modelled by Bouc-Wen model are larger than those by bilinear model. Seismic responses of NPP with LRB is significantly reduced than those without LRB. This reduction effect for seismic responses of NPP subjected to Site A (rock) earthquakes is larger than that to Site E (soft soil) earthquakes.

등가선형 및 이선형 납-고무받침 모델을 적용한 면진된 원전구조물의 지진 취약도 해석 (Seismic Fragility Analysis of Seismically Isolated Nuclear Power Plant Structures using Equivalent Linear- and Bilinear-Lead Rubber Bearing Model)

  • 이진희;송종걸
    • 한국지진공학회논문집
    • /
    • 제19권5호
    • /
    • pp.207-217
    • /
    • 2015
  • In order to increase seismic performance of nuclear power plant (NPP) in strong seismic zone, lead-rubber bearing (LRB) can be applied to seismic isolation system of NPP structures. Simple equivalent linear model as structural analysis model of LRB is more widely used in initial design process of LRB than a bilinear model. Seismic responses for seismically isolated NPP containment structures subjected to earthquakes categorized into 5 different soil-site classes are calculated by both of the equivalent linear- and bilinear- LRB models and compared each others. It can be observed that the maximum displacements of LRB and shear forces of containment in the case of the equivalent linear LRB model are larger than those in the case of bilinear LRB model. From the seismic fragility curves of NPP containment structures isolated by LRB, it can be observed that seismic fragility in the case of equivalent linear LRB model are about 5~30 % larger than those in the case of bilinear LRB model.

LRB와 슬라이딩베어링을 혼용한 면진시스템을 적용한 아파트 건물의 지진 응답 (Seismic Response of Apartment Building with Base Isolation System Consisting of Sliding-type Bearing and Lend Rubber Bearing)

  • 천영수;윤영호;황기태;장극관
    • 콘크리트학회논문집
    • /
    • 제19권4호
    • /
    • pp.507-514
    • /
    • 2007
  • 이 논문은 기존 내진설계와 비교하여 면진설계의 효용성과 경제적 효과에 대한 연구 결과를 정리한 것이며, 면진설계에 있어서는 납봉삽입적층고무베어링 (LRB)만을 사용한 경우와 비교하여 슬라이딩베어링과 LRB를 혼용한 면진시스템의 내진 거동을 함께 제시하였다. 연구 결과, 면진은 구조물에 대하여 지진동으로 인한 효과를 감소시키는데 매우 효과적이며, 층 가속도의 감소로 사용성을 증가시킬 수 있음이 입증되었다. 또한 층 가속도와 밑면 전단력의 감소라는 관점에서 슬라이딩베어링과 LRB를 혼용한 면진시스템이 LRB만을 사용한 경우보다 더 효과적임을 증명하였다. 하지만 경제적 효과 면에서는 증가된 성능에 비례하여 지불해야만 하는 비용도 커진다는 사실에 특별히 주의할 필요가 있는 것으로 나타났다.

메탄 하이드레이트 부존 퇴적층으로부터 획득한 수직탄성파 (VSP) 자료에서의 탄성파 진폭 감쇠 (Seismic attenuation from VSP data in methane hydrate-bearing sediments)

  • 송도 윤
    • 지구물리와물리탐사
    • /
    • 제10권1호
    • /
    • pp.29-36
    • /
    • 2007
  • 최근의 탄성파 탐사들은 퇴적층에 메탄 하이드레이트가 존재할 경우 탄성파 진폭 감쇠에 큰 영향을 미치는 것을 보여주고 있다. 이 논문에서는 일본 중부 토카이(Tokai) 해역의 난카이 트러프 (Nankai Trough) 탐사정에서 얻은 수직탄성파자료를 이용하여 30$\sim$110 Hz 주파수 대역에서 메탄 하이드레이트 부존층에서의 P 파 감쇠를 측정하였다. 두 개의 다른 측정방법들 (스펙트럼비 (spectral ratio) 방법과 중심 주파수 이동방법 (centroid frequency shift method))을 이용하여 감쇠 측정의 유효성을 조사하였다. 또한 감쇠 측정의 안정성을 증명하기 위해 측정 심도구간, 시추공의 불규칙 변화, 주파수 구간에 따른 감쇠 분석의 민감도를 조사하였다. 탄성파 주파수 대역에서는 메탄 하이드레이트 부존층에서 P 파의 큰 진폭 감쇠는 발견되지 않았다. 육안으로 보기에는 탄성파 주파수 대역에서의 최대 감쇠는 저포화도의 가스층에 발생한다. 그와는 반대로 같은 시추공에서 얻어진 음파검층의 주파수 대역 $(10{\sim}20\;kHz)$에서는 가장 높은 P 파의 진폭 감쇠가 메탄 하이드레이트 부존층과 관련이 있었다. 그러므로 이 연구는 메탄 하이드레이트 부존 퇴적층의 진폭 감쇠가 주파수에 의존함을 보여주고 있다. 메탄 하이드레이트 부존층은 탄성파 주파수 대역보다는 음파검층 주파수 대역에서 진폭 감쇠를 유발함을 알 수 있다. $30{\sim}110\;Hz$의 탄성파 주파수 대역이 메탄 하이드레이트 부존에 영향을 받지 않는 이유 중의 하나로서 메탄 하이드레이트 지역의 얇은층 들로 이루어진 층서구조의 영향을 제시하였다.