• 제목/요약/키워드: sectional area

검색결과 1,458건 처리시간 0.027초

Behavior of lightweight aggregate concrete voided slabs

  • Adel A. Al-Azzawi;Ali O, AL-Khaleel
    • Computers and Concrete
    • /
    • 제32권4호
    • /
    • pp.351-363
    • /
    • 2023
  • Reducing the self-weight of reinforced concrete structures problem is discussed in this paper by using two types of self-weight reduction, the first is by using lightweight coarse aggregate (crushed brick) and the second is by using styropor block. Experimental and Numerical studies are conducted on (LWAC) lightweight aggregate reinforced concrete slabs, having styropor blocks with various sizes of blocks and the ratio of shear span to the effective depth (a/d). The experimental part included testing eleven lightweight concrete one-way simply supported slabs, comprising three as reference slabs (solid slabs) and eight as styropor block slabs (SBS) with a total reduction in cross-sectional area of (43.3% and 49.7%) were considered. The holes were formed by placing styropor at the ineffective concrete zones in resisting the tensile stresses. The length, width, and thickness of specimen dimensions were 1.1 m, 0.6 m, and 0.12 m respectively, except one specimen had a depth of 85 mm (which has a cross-sectional area equal to styropor block slab with a weight reduction of 49.7%). Two shear spans to effective depth ratios (a/d) of (3.125) for load case (A) and (a/d) of (2) for load case (B), (two-line monotonic loads) are considered. The test results showed under loading cases A and B (using minimum shear reinforcement and the reduction in cross-sectional area of styropor block slab by 29.1%) caused an increase in strength capacity by 60.4% and 54.6 % compared to the lightweight reference slab. Also, the best percentage of reduction in cross-sectional area is found to be 49.7%. Numerically, the computer program named (ANSYS) was used to study the behavior of these reinforced concrete slabs by using the finite element method. The results show acceptable agreement with the experimental test results. The average difference between experimental and numerical results is found to be (11.06%) in ultimate strength and (5.33%) in ultimate deflection.

만성 폐쇄성 폐질환에서 기관의 단면적과 폐기능지표와의 상관관계 (Correlation of Tracheal Cross-sectional Area with Parameters of Pulmonary Function in COPD)

  • 이찬주;이재호;송재우;유철규;김영환;한성구;심영수;정희순
    • Tuberculosis and Respiratory Diseases
    • /
    • 제46권5호
    • /
    • pp.628-635
    • /
    • 1999
  • 연구배경 : 만성 폐쇄성 폐질환을 대변하는 폐기종에서 주요 기능적 장애는 호기의 장애이며, 최대 호기류량은 기도의 크기, 폐의 탄력반동압 그리고 기도의 함몰성에 의해 결정된다. 기도의 항몰성은 폐기종에서 기류를 제한하는 하나의 기전으로 작용하지만, 폐용적과 폐의 과팽창을 유지하는 기전으로 작용하여 가스교환을 증진시킨다는 주장도 있다. 따라서 폐기종에서 기관이 호흡에 미치는 생리학적 역할이 무엇인지를 알아보고자 본 연구를 수행하였다. 방 법 : 1997년 1월 1일부터 8월 31일까지 보라매병원 호흡기내과를 방문하여 단순 흉부방사선검사, 체간용적기록계(body plethysmography)를 포함하는 폐기능검사 및 HRCT를 통해 폐기종으로 진단된 20명을 대상으로 하였다. HRCT에서 대동맥궁의 정상부위에서 기관의 단면적을 호흡주기에 따라 측정하고 이를 체표면적으로 보정한 값과 동맥혈의 이산화탄소분압 및 산소분압, 기도저항, 폐유순도 등 폐기능지표와의 상관 관계를 분석하였다. 결 과 : 폐기종에서 기관의 단면적은 호기시 동맥혈의 이산화탄소분압(r=-0.61, p<0.05) 및 산소분압(r=0.6, p<0.05) 그리고 매분환기량(r=0.73, p<0.05)과 유의한 상관관계가 있었지만, 흡기시에는 상관관계가 없었다(이산화탄소분압과는 r=-0.22, p>0.05, 산소분압과는 r=0.26, p>0.05, 매분환기량과는 r=0.44, p>0.05). 매분환기량은 상시호흡량(tidal volume)과는 r=0.45(p<0.05)로 유의한 상관관계가 있었지만, 호흡수와는 r=-0.31(p>0.05)로 상관관계가 없었다. 폐기종에서 기관의 단면적은 호흡주기와 상관없이 $FEV_1$ FVC, $FEV_1$/FEC, 최대 호기류량, 잔기용적, 폐확산능, 기도저항, 폐유순도 등의 다른 폐기능지표와는 상관관계가 없었다. 결 론 : 폐기종에서 호기시 기관의 단면적은 주로 가스 교환(gas exchange)의 지표들과 유의한 상관관계가 있었지만, 폐용적이나 폐의 과팽창을 시사하는 지표와는 상관관계가 없었다. 따라서 폐기종에서는 호기시 동일 압력점의 개념에 의해 발생하는 기도압박으로 기관의 단면적이 감소하고 이러한 현상이 기류를 제한하는 하나의 기전으로 작용하는 것이지 폐용적이나 폐의 과팽창을 유지시켜 가스교환을 증진시키는 것은 아니라고 생각된다.

  • PDF

자동차용 강판의 겹치기 $CO_2$ 레이저 용접에서 용접속도와 판재간격에 따른 용접특성 연구 (Effects of the Gap and the Speed on the Lap-Joint $CO_2$ Laser Welding of Automotive Steel Sheets)

  • 이경돈;박기영;김주관
    • Journal of Welding and Joining
    • /
    • 제20권4호
    • /
    • pp.510-516
    • /
    • 2002
  • Recently the laser welding technology has been applied increasingly for the automotive bodies. But the lap joint laser welding for 3 dimensional automotive body is new while the butt joint laser welding is well known as the tailored blank technology. In this study, the process window was found for the full penetration welding of the lap joint of the 1mm-thick high strength steel sheets. The limit curves and characteristic curves were suggested to define the boundaries and the contour lines in a space of the welding speed and the gap size. The characteristics of the weld sectional geometry were used to determine the limit curves. They are bead width, penetration depth and sectional area. After the observed data was analysed carefully, it was noticed that there was a transition point at which the sectional shape was changed and the bead area jumped as the welding speed was increased. Also a new concept of 'input energy Per volume' was suggested to distinguish the difference at the transition Point. The difference of sectional areas at the transition point can be related to the dynamic keyhole phenomena.

고온초전도 테이프를 이용한 적층형 전류 도입선의 최적설계 (Optimum Design of Multi-Stacking Current Lead Using HTS Tapes)

  • 설승윤;김민수;나필선
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제3권1호
    • /
    • pp.35-39
    • /
    • 2001
  • The optimum cross-sectional area profile of gas-cooled high-temperature superconductor(HTS) current lead is analyzed to have minimum helium boil-off rate. The conventional constant area HTS lead has much higher helium consumption than the optimum HTS lead considered in this study. The optimum HTS lead has variable cross-sectional area to have constant satiety factor. An analytical formula of optimum shape of lead and temperature profile are obtained. For multi-stacking HTS current leads, the optimum tape lengths and minimum heat dissipation rate are also formulated. The developed formulations are applied to the Bi-2223 material, and the differences between constant area, constant safety-factor, and multi-stacking current leads are discussed.

  • PDF

고온초전도 테이프를 이용한 다단 전류 도입선의 최적설계 (Optimal Design of Multi-Step Current Leads Using HTS Tapes)

  • 김민수;나필선;설승윤
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2001년도 학술대회 논문집
    • /
    • pp.84-88
    • /
    • 2001
  • The optimum cross-sectional area Profile of gas-cooled high-temperature superconductor (HTS) current lead is analyzed to have minimum helium boil-off rate. The conventional constant area HTS lead has much higher helium consumption than the optimum HTS lead considered in this study. The optimum HTS lead has variable cross-sectional area to have constant safety factor. An analytical formula of optimum shape of lead and temperature profile are obtained. For multi-step HTS current leads, the optimum tape lengths and minimum heat dissipation rate are also formulated. The developed formulations are applied to the Bi-2223 material, and the differences between constant area, constant safety-factor, and multi-step current leads are discussed.

  • PDF

하악의 전방 이동이 상부기도의 용적에 미치는 영향 (The Effect of Mandibular Anterior Repositioning on the Upper Airway Volume)

  • 최재갑;기우천;강덕식
    • Journal of Oral Medicine and Pain
    • /
    • 제24권1호
    • /
    • pp.69-80
    • /
    • 1999
  • OBJECTIVES: This study was designed to measure the minimal cross-sectional areas and volumes of the pharynx in snoring patients and normal subjects and to see if there is an increase in the minimal cross-sectional areas and volumes of the pharynx with advancement of the mandible. METHODS: The pharyngeal computed tomography and 3-dimensional reconstruction were used to measure the cross-sectional areas and volumes of the nasopharynx, oropharynx, and hypopharynx with the jaw in normal position and in protrusive position in 7 patients with snoring and 7 control subjects while they were awake. RESULTS: The oropharynx was revealed to have the most narrow site in the pharynx and there was a tendency for the snorers to have a smaller nasopharyngeal and oropharyngeal cross-sectional area than normal subjects but not statistically significant. There were no significant differences in the volumes of the nasopharynx and oropharynx between the two groups. With advancement of the jaw the minimal cross-sectional area of oropharynx was significantly increased, and the volume was also increased but not significantly. The minimal cross-sectional areas and volumes of nasopharynx as well as hypopharynx were not significantly influenced by the advancement of the mandible. CONCLUSIONS: There was a tendency for snorers to have a smaller oropharynx than normal subjects and the oropharyngeal lumen was increased with the advancement of the mandible in both snorers and normal subjects.

  • PDF

정압기 임계유동특성 및 배관망해석 요소로서의 고려에 관한 수치해석적 연구(II);단면적 및 개도 변화 (Numerical Study for The Critical-Flow-Characteristics of The Pressure Regulator and Considerations as a Pipe Network Element (II);Influence of the Cross-Sectional-Area and Opening Ratio)

  • 신창훈;하종만;이철구;허재영;임지현;주원구
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1454-1459
    • /
    • 2004
  • The major parameters governing the fluid dynamical and thermo-dynamical behavior in the large pipeline network system are friction loss and the pipeline length. But in local pipeline networks and relatively short distance pipeline system, secondary loss and the considerations of the moving states of the fluid machine are also important. One of the major element in local pressure control system is pressure regulator. It causes the variations of the physical properties in that pipeline system. When it is under working, the accurate analysis of the flow properties is so difficult. In this study, some numerical approaches to investigate the critical-flow-characteristics of the pressure regulator have been done according to the variations of the opening ratio or cross-sectional area and the detail examinations and considerations of the pressure regulator as a pipeline network elements have been carried. Finally the flow-flied distributions and critical-flow-characteristics have been presented in detail and the critical flow phenomena and the relation to the opening ratio or cross-sectional-area ratio have been studied.

  • PDF

유체봉입 마운트의 유로 조절에 따른 진동감쇠 성능향상 (Dynamic Analysis of Switchable Hydraulic Engine Mount with an Inertia Track and a Decoupler)

  • 안영공
    • 한국소음진동공학회논문집
    • /
    • 제27권1호
    • /
    • pp.80-86
    • /
    • 2017
  • This paper describes switching method of the cross-sectional area of the fluid passage way to improve the performance of a hydraulic engine mount with an inertia track and a decoupler. The mount has nonlinear dynamic characteristics depending on the vibrational frequency and amplitude. For the convenience of analysis, two linear motion equations were derived on the basis of the mechanical model according to the low-and high-frequencies. The properties of the transmissibility and dynamic stiffness derived from the equations were investigated according to switching the cross-sectional area of the inertia track and decoupler. Switching method of the cross-sectional area can be derived from the transmissibility plot. In comparison between transmissibility of passive and switchable mounts with an inertia track and a decoupler, the performance of the switchable mount is improved greatly than the passive mount. The resonant peak is remarkably reduced in the high frequency region.

흡연이 비저항에 미치는 영향 (Effect of Smoking on Nasal Resistance)

  • 오천환;김장욱
    • 대한기관식도과학회지
    • /
    • 제5권2호
    • /
    • pp.113-118
    • /
    • 1999
  • Background & Objectives : Nasal resistance which is halfly responsible for airway resistance is known to be influenced by hypoxia, hypercapnia, exercise, pregnancy, alcohol, ammonia and smoking. Smoking is a common part of our sociocultural environment and we have many a times been introduced to its various adverse effects, which have usually been more focused on lung problems. The purpose of this study is to determine any relationship between smoking and nasal resistance and to evaluate it's effective sites. Materials and Methods : Acoustic rhinometry was performed in 25 smokers and 25 nonsmokers who had no nasal symptoms nor abnormal rhinoscopic findings, and used an acoustic rhinometry to measure the distance from nose-piece to the C-notch, cross sectional area at the C-notch, and volume of the nasal cavity from nose-piece to 7cm. The authors compared the data between the two groups. Results : The cross sectional area at the C-notch was significantly decreased(p<0.05) in smoking group. The distance to the C-notch and the volume of nasal cavity were decreased likely in smoking group but there were no significant difference(p>0.05). Conclusion : Smoking reduced the cross sectional area at the C-notch, so increased the nasal resistance. The underlying mechanisms seems to be decreased nasal mucosal reactivity and congestion of the nasal mucosa. The authors believe there should follow more studies on pathophysiologic mechanisms and the histopathologic changes which involve the effect of smoking on nasal structures.

  • PDF

강섬유 보강 콘크리트 내 강섬유의 재향성 및 분포특성에 관한 연구 (EVALUATION OF REORIENTATION AND DISTRIBUTION OF STEEL FIBERS IN SFRC)

  • 이차돈
    • 콘크리트학회지
    • /
    • 제2권3호
    • /
    • pp.65-72
    • /
    • 1990
  • 섬유 콘크리트 내의 단위 면적당 섬유 개수에 대한 이론식이 공시체의 경계조건의 영향을 고려하여 유도되었다. 또한 단위 면적당의 섬유 개수는 각기 다른 섬유형태, 그리고 다른 용적 혼합율(volume fractions)을 갖는 공시체에 대하여 실험적으로도 산정되었으며 이들 실험치들에 근거한 통계적 해석을 통한 공시체 각 단면에 따른 단위 면적당 강섬유 수의 집중 정도의 차이가 평가 되었다. 또한 vibration에 의한 강섬유의 재향성(reorientation)의 정도는 이론치와 실험치의 차이를 비교함으로서 검토되었다.