• 제목/요약/키워드: secondary effluent

검색결과 142건 처리시간 0.022초

생물학적 고도처리공법에 적용된 두 형태의 장방형 이차침전지 성능 파악 (Evaluating Two Types of Rectangular Secondary Clarifier Performance at Biological Nutrient Removal Facilities)

  • 이병희
    • 상하수도학회지
    • /
    • 제27권5호
    • /
    • pp.561-570
    • /
    • 2013
  • There are two types of rectangular secondary clarifier at biological nutrient removal (BNR) facility to settle MLSS; conventional activated sludge secondary clarifier and Gould Type I clarifier. In this study, the performances of two types at respective biological nutrient removal facility are compared using weekly operational data. Surface Overflow Rate (SOR), Surface Loading Rate (SLR), Sludge Volume Index (SVI), secondary effluent SS concentration are studied. It has found that Gould Type I has 3.5 times less average secondary effluent SS concentration that is 2.4 mg/L than that of conventional activated sludge secondary clarifier. Both SOR and SLR have shown little effect on secondary effluent SS concentrations at Gould Type I clarifier in contrary that SOR affects the secondary effluent SS concentrations at conventional activated sludge rectangular secondary clarifier. From this study, it is recommended that Gould Type I must be considered for secondary clarifier when BNR plant is designed.

재사용을 위한 하수처리장 방류수의 고급산화처리 (Advanced Oxidation Processes of Secondary Effluent for Reuse)

  • 조일형;송경석;성기석;정문호;이홍근;조경덕
    • 한국환경보건학회지
    • /
    • 제26권3호
    • /
    • pp.61-68
    • /
    • 2000
  • The use of photo-catalytic processes in pollution abatement and resource has a significant economic importance. Therefore, the applications of photochemical oxidation of secondary effluent driven by UV, TiO2, TiO2/UV, H2O2/UV and TiO2/H2O2/UV, have been investigated in order to treat the secondary effluent from municipal sewage. Various experimental parameters such as BOD, CODcr, Nurbidity, total P, and SPC were examined in each photo-catalytic reaction system. The results showed that the application of single oxidant such as UV, TiO2 only has a minor effect on parameters reduction (CODcr, BOD, etc) to treat the secondary effluent, whereas the combinations of oxidants increase the removal efficiency. The best removal efficiency in every parameters was achieved by the combination of TiO2, H2O2 and UV. It was also found that the optimum amount of TiO2 for the treatment was 1g/ι to achieve water reuse standard. From the results, the photocatalytic reaction system can be an alternative as a post-treatment to treat the secondary effluent from municipal sewage.

  • PDF

Genotoxic and Neurotoxic Potential in Marine Fishes Exposed to Sewage Effluent from a Wastewater Treatment Plant

  • Park, So-Yun;Kim, So-Jung;Rhee, Yong;Yum, Seung-Shic;Kwon, Tae-Dong;Lee, Taek-Kyun
    • Molecular & Cellular Toxicology
    • /
    • 제5권3호
    • /
    • pp.265-271
    • /
    • 2009
  • Concentrations of industrial, agricultural and natural chemicals have been increasing in secondary effluents without their combined sub-lethal effects having been elucidated. In this study, two assays (the comet and acetylcholinesterase assays) were combined to evaluate the genotoxic and neurotoxic effects of effluent from the Noksan wastewater treatment plant (WWTP) on two local marine fish species (flounder and sea eel). The fish were exposed to WWTP secondary effluent that had been diluted with filtered seawater to final concentrations of 1%, 10% and 50%. Analysis of fish samples collected 3 and 5 days after exposure showed that DNA damage occurred in flounder exposed to 50% effluent and in sea eels exposed to 10% or 50% effluent. Furthermore, it was found that acetylcholinesterase (EC:3.1.1.7, AChE) activity decreased in both species when exposed to 10% effluent, indicating the presence of large amounts of genotoxic and neurotoxic chemicals in the effluent. Our results indicate that the comet and AChE assays are promising tools for biomonitoring of secondary effluents.

CFD와 PIV test를 통한 장방형 2차침전지 유입 및 유출배플 형상 최적화 (Optimization of influent and effluent baffle configuration of a rectangular secondary clarifier using CFD and PIV test)

  • 최영균;배강형;윤정환
    • 상하수도학회지
    • /
    • 제24권1호
    • /
    • pp.41-50
    • /
    • 2010
  • The influent and effluent baffle configurations seriously affect the hydraulic characteristics of the secondary clarifier in wastewater treatment plant. In this study, those baffle configurations were optimized by computational fluid dynamics(CFD) analysis and particle image velocity(PIV) test in order to obtain uniform flow in inlet region and to minimize upflow velocity in outlet region of the secondary clarifier. Theoretical analysis using CFD showed that more uniform flow could be accomplished when the influent baffle was located closely to the inlet opening. Effects of effluent baffle configuration on the upflow velocity in the outlet region of the secondary clarifier were analyzed with four types of effluent baffles which are widely adopted for secondary clarifier design. From the CFD analysis, McKinney baffle(EB-2) was estimated to be the most effective for restraining the upflow velocity in the outlet region and these trends were identified by PIV tests. In addition, the McKinney baffle showed the most uniform overflow velocity distribution around the weir.

전자선을 이용한 하수처리장 방류수내 대장균군 살균 (Disinfection of Total Coliforms in Sewage Treatment Effluent using Electron Beam)

  • 김유리;한범수;김진규;강호
    • 한국물환경학회지
    • /
    • 제20권4호
    • /
    • pp.376-381
    • /
    • 2004
  • The use of electron beam irradiation was investigated to disinfect total coliforms in the secondary sewage treatment effluent. Unchlorinated secondary effluent was irradiated at different dose of 0.2~1.0 kGy by 1 MeV, ELV-4 Model electron beam accelerator. It is interesting to note that a 100 % reduction in total coliforms and total colonies were achieved until a dose of approximately 0.8 kGy. Even at low dose of 0.2 kGy, the total coliforms and total colonies were successfully inactivated to the level of satisfying the new effluent discharge guideline. Besides disinfection of total coliforms, approximately a 50% removal in biochemical oxygen demand was pronounced at a dose of 0.2 kGy. More than 20 % removal in suspended solids and turbidity was also observed at a dose of 1.0 kGy. The application of electron beam irradiation appeared to be one of options to reuse sewage treatment effluent as agricultural or industrial water.

하수처리장의 유지제거에 대한 연구 (A Study on the Removal of Grease and Oill in the Treatment Plant)

  • 박재효
    • 한국환경보건학회지
    • /
    • 제7권1호
    • /
    • pp.1-7
    • /
    • 1981
  • During 20 days from November 4 to 28, 1980, the quantities of grease and oil, BOD (biological oxygen demand), COD (chemical oxygen demand), SS (suspended solid) were measured at Grit Chamber, Primary Sedimentation Tank, Secondary Sedimentation Tank in Chung Gye Chun sewage treatment plant. The results were as follows. 1. The average of grease and oil quantities were 251mg/l at Grit Chamber, 185mg/l at Primary Sedimentation Tank, 47mg/l at Secondary Sedimentation Tank. 2. In the secondary treatment for the removal of grease and oil, the removed quantities of grease and oil were increased according to increasing the quantities of influent grease and oil. The regression equation were as follows G.O.removed=0.731 G.O. influent+3.235 (r=0.887) 3. The average of grease and oil removal rate was 76.4% and the standard deviation of grease and oil removal rate daily was 10.6%. 4. G.O. (grease and oil) and BOD, COD, SS showed significant correlationship at Grit Chamber, Primary Sedimentation Tank, Secondary Sedimentation Tank. (P<0.05). 5. In the secondary treatment, effluent grease & oil and other parameters were analyzed by means of Stepwise multiple regression. Multple regression equation for estimates of effluent grease and oil were as follows. $GO_E=-9.1637+2.0380 SS_E+0.068 SS_I$ (r=0.778) 6. The correlative parameters for the effluent grease and oil seem to be the influent SS and the effluent SS. 7. It was estimated that the removal of grease and oil would be improved by means of improvement of suspended solids removal efficiency but it is necessary to inquire further into the study.

  • PDF

활성슬러지공정 하수종말처리장의 단위공정별 세균 제거효율 (Bacterial Removal Efficiencies by Unit Processes in a Sewage Treatment Plant using Activated Sludge Process)

  • 이동근;정미라;성기문;박성주
    • 한국물환경학회지
    • /
    • 제26권5호
    • /
    • pp.871-879
    • /
    • 2010
  • To figure out the removal efficiency of indicator and pathogenic bacteria by unit processes of a sewage treatment plant using activated sludge process, analyses were done for incoming sewage, influent and effluent of primary clarifier, aeration tank, secondary clarifier and final discharge conduit of the plant. A matrix of bacterial items (average of bacterial reduction [log/ml], p value of paired t-test, number of decreased cases of twenty analyses, removal percentage only for decreased cases) between incoming sewage and final effluent of the plant were heterotrophic plate counts (1.54, 0.000, 20, 95.01), total coliforms (1.38, 0.000, 19, 83.94), fecal coliforms (0.90, 0.000, 20, 94.84), fecal streptococci (0.90, 0.000, 20, 98.08), presumptive Salmonella (0.23, 0.561, 7, 99.09), and presumptive Shigella (1.02, 0.002, 15, 92.98). Total coliforms, fecal coliforms, heterotrophic plate counts, and fecal streptococci showed highest decrease through secondary clarifier about 1-log (p<0.001) between 88% and 96%, and primary clarifier represented the significant (p<0.05) decrease. However, final effluent through discharge conduit showed higher total coliforms and fecal streptococci than effluent of secondary clarifier (p<0.05). In addition, final effluent once violated the water quality standard while effluent of secondary clarifier satisfied the standard. Hence some control measures including elimination of deposits in discharge conduit or disinfection of final effluent are necessary.

전기응집을 이용한 2차 유출수의 질소.인 제거 공정 연구 (Removal of nitrogen and phosphorus of the secondary effluent by electro-coagulation)

  • 한송희;장인성
    • 상하수도학회지
    • /
    • 제26권4호
    • /
    • pp.579-589
    • /
    • 2012
  • To reduce extensive energy costs of the internal recycling for the purpose of denitrification in the advanced wastewater treatment, a post-treatment process using an electro-coagulation to treat nitrate in the secondary effluents is evaluated in this study. Removals of phosphorus and organics in the secondary effluents by the electro-coagulation were also evaluated to propose an alternative advanced wastewatert treatment process. A series of experiments of the electro-coagulation were carried out with the following 4 different samples: synthetic solution containing nitrate only, synthetic solution containing nitrate as well as phosphorus, secondary effluents from activated sludge cultivated in laboratory, and secondary effluents from real wastewater treatment plants. Removals of nitrate and phosphorus in the synthetic solution were 30 and 97 % respectively, which verified the feasibility of the process. Removals of nitrate, phosphorus and COD in the secondary effluents from the cultivated sludge in laboratory were 49, 90 and 19 % respectively. Removal efficiency of the total nitrogen, nitrrate, phosphorus and COD in the secondary effluent from real wastewater treatment plant were 50, 61, 98 and 80 % respectively. The removal of the total nitrogen was less than the nitrate as expected, which is due to the formation of ammonia nitrogen in the cathode. But the proposed scheme could be an energy saving and alternative process for the advanced wastewater treatment if further studies for the process optimization are carried out.

물 재이용을 위한 하수처리장 방류수 색도의 자외선처리에 미치는 과산화수소의 영향 (Effect of Hydrogen Peroxide on UV Treatment of Color in Secondary Effluent for Reclamation)

  • 박기영;맹승규;김기팔;이석헌;권지향;안규홍
    • 상하수도학회지
    • /
    • 제18권3호
    • /
    • pp.377-384
    • /
    • 2004
  • In the present study, a feasibility of an advanced oxidation process using UV/Hydrogen peroxide($H_2O_2$) system equipped with a medium pressure lamp for secondary effluent reclamation was investigated. Initial concentration of $H_2O_2$ and pH were changed to determine the optimum operation condition for the system. The removal efficiency of color was than 80% with 14.3mg/L of initial $H_2O_2$ and 5 minute of contact time in the UV/$H_2O_2$ system. The color removal was analyzed using first-order reaction equation. The dependence of rate constant (k) on initial $H_2O_2$ represented the rational relationship with maximum value. Residual $H_2O_2$ caused increase of effluent COD, since analyzing agent, dichromate, reacted with $H_2O_2$ in the sample. Therefore, excess initial concentration of $H_2O_2$ would significantly affect effluent COD measurement. At pH variation experiment, both residual $H_2O_2$ and color showed peak in the neutral pH range with the same pattern. Effect of $H_2O_2$ dose also enhanced color removal but raised residual $H_2O_2$ problem in the continuous operation UV system. In conclusion, these results indicated that medium pressure UV/$H_2O_2$ system could be used to control color in the secondary effluent for reclamation and reuse.

신양천 하천수정화 연못시스템의 처리수준 및 연못반응 (Treatment Level and Reactions of a Treatment Pond System Purifying Sinyang Stream Water)

  • 양홍모
    • 한국환경복원기술학회지
    • /
    • 제8권6호
    • /
    • pp.1-12
    • /
    • 2005
  • Treatment level and pond reactions of a pond system were examined from May to October 2002. The system was constructed in July 2000 for purifying water of Sinyang stream that flows into Koheung Estuarine Lake located in the southern part of the Korean Peninsula. The system was composed of a primary and a secondary pond in series and established on the rice field near the lake. Water pumped from the stream was funneled into the primary pond, whose effluent was discharged into the secondary pond by gravity flow. Effluent from the secondary pond was funneled into wetlands. About 130 $m^3$/day of water was pumped into the primary pond and detention time of the primary and secondary pond was about 2 days. DO from the surface to the 1.0 m depth of the primary and secondary pond was in the rage of 5.2 to 11.0 mg/L and 4.3 to 0.7 mg/L, respectively. DO at the bottom layer of the primary pond was 0 mg/L and that of the secondary pond ranged 3.0~4.7 mg/L. The primary pond functioned as a facultative pond and the secondary as an aerobic one. The temperature difference between the surface and bottom layers of the ponds in August was about $2.5^{\circ}C$ and that in May and October was about $1.0^{\circ}C$. Thermocline was observed in the primary pond during the high ambient temperature of August. The sludge depth of the primary pond in May, August, and October was 2.4, 1.9, and 2.2 cm, respectively. That of the secondary pond was 1.2, 1.0, and 1.1 cm, respectively. SS, $BOD_5$, T-N, and T-P concentrations in influent averaged 16.64, 6.71, 6.21, and 0.23 mg/L and those in effluent from the primary pond averaged 11.48, 4.97, 4.81, and 0.17 mg/L, respectively. The removal rates of the primary pond for SS, $BOD_5$, T-N and T-P were 31%, 26%, 22%, and 24%, respectively. Average concentrations of SS, $BOD_5$, T-N, and T-P in effluent from the secondary pond were 9.81, 4.07, 4.03, and 0.14 mg/L, respectively and the abatement rates of the secondary pond for SS, $BOD_5$, T-N and T-P were 20%, 12%, 13%, and 15%, respectively. SS, $BOD_5$, T-N and T-P concentrations in effluent from the primary pond were significantly low(p=0.001) when compared with those from the secondary one.