• Title/Summary/Keyword: secondary coil

Search Result 140, Processing Time 0.024 seconds

Effect of Heat Treatment on Properties of Tungsten Embolization Coils (텅스텐 색전코일의 특성에 미치는 열처리 효과)

  • Son, Ung-Hui;Hong, Sun-Hyeong;Sin, Gyeong-Min;Lee, Yun-Sin;Park, Jae-Hyeong
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.4
    • /
    • pp.333-339
    • /
    • 1998
  • The effect of heat treatment conditions on the properties of tungsten(W) embolization coils has been evaluated. The W embolization coils were fabricated by coiling the primary W coil with a diameter of 30.mm on a alumina rod mandrel with a diameter of 2.92mm. The secondary coils were then heat treated at 475$^{\circ}C$and 600$^{\circ}C$ for various heat treatment time ranging from 5 minutes to 36hours. The pitch distance, diameter and shape retention capability of the W embolization coils were characterized after the heat treatment. The pitch distance of the W embolization coils increased with the heat treatment time. The diameter of W emboliazation coils decreased continuously with heat treatment time. The shape retention capability of the W embolization coils increased with the heat treatment time due to an increase in elasticity by formation of tungsten oxide film on W coil surface during the heat treatment. The heat treatment condition of W embolization Col at 600$^{\circ}C$ for 20 minute was considered desirable based on the optimization of the shape retention capability, pitch distance and secondary coil diameter after heat treatment.

  • PDF

Implementation of a Transcutaneous Power Transmission System for Implantable Medical Devices by Resonant Frequency Tracking Method (주파수 추적 방식에 의한 이식형 의료기기용 무선전력전달 장치 구현)

  • Lim, H.G.;Lee, J.W.;Kim, D.W.;Lee, J.H.;Seong, K.W.;Kim, M.N.;Cho, J.H.
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.5
    • /
    • pp.401-406
    • /
    • 2010
  • Recently, many implantable medical devices have been developed and manufactured in many countries. In these devices, generally, energy is supplied by a transcutaneous method to avoid the skin penetration due to the power wires. As the most transcutaneous power transmission methods, the electromagnetic coupling between two coils and resonance at a specific frequency has been used widely. However, in case of a transcutaneous power transmitter with a fixed switching frequency to drive an electromagnetic coil, inefficient power transmission and thermal damage by the undesirable current variation may occur, because the electromagnetic coupling state between a primary coil and a secondary coil is very sensitive to skin thickness of each applied position and by person. In order to overcome these defects, a transcutaneous power transmitter of which operating frequency can be automatically tracked into the resonance frequency at each environment has been designed and implemented. Through the results of experiments for different coil surroundings, we have been demonstrated that the implemented transcutaneous power transmitter can track automatically into a varied resonance frequency according to arbitrary skin thickness change.

Safety and Efficacy of Flow Diverter Therapy for Unruptured Intracranial Aneurysm Compared to Traditional Endovascular Strategy : A Multi-Center, Randomized, Open-Label Trial

  • Kim, Junhyung;Hwang, Gyojun;Kim, Bum-Tae;Park, Sukh Que;Oh, Jae Sang;Ban, Seung Pil;Kwon, O-Ki;Chung, Joonho;Committee of Multicenter Research, Korean Neuroendovascular Society,
    • Journal of Korean Neurosurgical Society
    • /
    • v.65 no.6
    • /
    • pp.772-778
    • /
    • 2022
  • Objective : Endovascular treatment of large, wide-necked intracranial aneurysms by coil embolization is often complicated by low rates of complete occlusion and high rates of recurrence. A flow diverter device has been shown to be safe and effective for the treatment of not only large and giant unruptured aneurysms, but small and medium aneurysms. However, in Korea, its use has only recently been approved for aneurysms <10 mm. This study aims to compare the safety and efficacy of flow diversion and coil embolization for the treatment of unruptured aneurysms ≥7 mm. Methods : The participants will include patients aged between 19 and 75 years to be treated for unruptured cerebral aneurysms ≥7 mm for the first time or for recurrent aneurysms after initial endovascular coil embolization. Participants assigned to a flow diversion cohort will be treated using any of the following devices : Pipeline Flex Embolization Device with Shield Technology (Medtronic, Minneapolis, MN, USA), Surpass Evolve (Stryker Neurovascular, Fremont, CA, USA), and FRED or FRED Jr. (MicroVention, Tustin, CA, USA). Participants assigned to a coil embolization cohort will undergo traditional endovascular coiling. The primary endpoint will be complete occlusion confirmed by cerebral angiography at 12 months after treatment. Secondary safety outcomes will evaluate periprocedural and post-procedural complications for up to 12 months. Results : The trial will begin enrollment in 2022, and clinical data will be available after enrollment and follow-up. Conclusion : This article describes the aim and design of a multi-center, randomized, open-label trial to compare the safety and efficacy of flow diversion versus traditional endovascular treatment for unruptured cerebral aneurysms ≥7 mm.

A three-region movable-boundary helical coil once-through steam generator model for dynamic simulation and controller design

  • Shifa Wu;Zehua Li;Pengfei Wang;G.H. Su;Jiashuang Wan
    • Nuclear Engineering and Technology
    • /
    • v.55 no.2
    • /
    • pp.460-474
    • /
    • 2023
  • A simple but accurate mathematical model is crucial for dynamic simulations and controller design of helical coil once-through steam generator (OTSG). This paper presents a three-region movable boundary dynamic model of the helical coil OTSG. Based on the secondary side fluid conditions, the OTSG is divided into subcooled region (two control volumes), two-phase region (two control volumes) and superheated region (three control volumes) with movable boiling boundaries between each region. The nonlinear dynamic model is derived based on mass, energy and momentum conservation equations. And the linear model is obtained by using the transfer function and state space transformation, which is a 37-order model of five input and three output. Validations are made under full-power steady-state condition and four transient conditions. Results show good agreements among the nonlinear model, linear model and the RELAP5 model, with acceptable errors. This model can be applied to dynamic simulations and controller design of helical coil OTSG with constant primary-side flow rate.

Characteristics of Superconducting Elements in Series-Connected Three-Phase Flux-Lock type SFCL (3상 자속구속형 한류기의 초전도 소자 직렬연결 특성분석)

  • Park, Hyoung-Min;Choi, Hyo-Sang;Cho, Yong-Sun;Hwang, Jong-Sun
    • Proceedings of the KIEE Conference
    • /
    • 2007.04b
    • /
    • pp.35-36
    • /
    • 2007
  • We investigated the characteristics of three phase flux-lock type SFCL. Three phase flux-lock type consists of three reactor wound on an iron core in each single phase and the secondary coil is connected to the superconducting elements in series. the superconducting elements with serial connection were quenched simultangously in the single line-to-ground fault.

  • PDF

개선된 자속구속형 전류제한기의 동작 특성 분석

  • Kim, Yong-Jin;Du, Ho-Ik;Kim, Min-Ju;Lee, Dong-Hyeok;Han, Byeong-Seong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.215-215
    • /
    • 2009
  • Improved flux-lock type superconducting fault current limiter(SFCL) is composed of a series transformer and superconducting unit of the YBCO coated conductor. The primary and secondary coils in the transformer were wound in series each other through an iron core and the YBCO coated conductor was connected with secondary coil in parallel. In this paper, we investigated the current limiting characteristics through initial line current after fault initiation. through the analysis, it was shown that the smaller initial line current is superior to current limiting characteristics and a point of view of power burden of the YBCO coated conductor.

  • PDF

High-Efficiency Non-contact Power Supply System

  • Zheng, Bin;Kwan, Dae-Hwan;Lee, Dae-Sik
    • Proceedings of the Korea Society of Information Technology Applications Conference
    • /
    • 2005.11a
    • /
    • pp.233-235
    • /
    • 2005
  • Non-contact power supply (NCPS), as a clean and safe energy supply concept has been applying wildly. Comparing with the conventional transformer the non-contact transformer has a large air gap between the long primary winding and the secondary winding. Due to it, the non-contact transformer has increased leakage inductance and reduced magnetizing inductance. So the high frequency series resonant converter has been widly used on the non-contact power supply system for transferring the primary power to the secondary one, from what a high influence voltage can be gained on the secondry coil even though the large air gap exists. However, it still has the disadvantages of the load sensitive voltage gain characteristics when load is changing. In this paper, we propose a fuzzy logic controller to adjust the frequency of the inverter to track the resonat which is changing when the load is change.

  • PDF

Optimal Construction of Rotary-Linear Induction Motor (회전-리니어 병용 유도전동기의 특성해석)

  • Onuki, Takashi;Jeon, Woo-Jin;Tanabiki, Masamoto;Yoo, Ji-Yoon
    • Proceedings of the KIEE Conference
    • /
    • 1997.07a
    • /
    • pp.130-132
    • /
    • 1997
  • In this paper, we propose a new type of tubular linear induction motor(TLIM) with two-dimensional motion. The proposed motor consists of four short primary LIMs arranged on a same circumference and a common secondary. By adopting independently energized ring-windings to the primary, we can expect the reduction of coil-end region and the freedom of alternating current supply. The secondary conductor is capable of producing anyone of rotary, linear, and helical motions by controlling the phase of supply currents in each primary winding. From the 3-D finite element analysis and the experiment, we derive the feeding conditions to increase the subsidiary rotary-force and an optimal arrangement of primary currents to reduce the number of slot.

  • PDF

Characteristic analysis of inductive contactless power transformer used for the road/railway to improve the performance. (도로/궤도 매립형 무접촉 집전장치의 전력전달 성능 개선을 위한 특성해석)

  • Han K.H.;Baek S.H.;Lee B.S.;Bae C.H.;Byun Y.S.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1304-1306
    • /
    • 2004
  • Recently, the study for development of system having affinity for environment is on investigation. This issue is also applicable to transportation system. This paper suggested the inductive power transformer used for the road/railway applied to contactless power transfer system. The two secondary windings, large gaped magnetic structure and horizontal alignment between primary and secondary coil for that transformer approach a process for improvement of contactless power transfer system performance.

  • PDF

Design, Implementation and Testing of HF transformers for Satellite EPS Applications

  • Zahran, Mohamed
    • Journal of Power Electronics
    • /
    • v.8 no.3
    • /
    • pp.217-227
    • /
    • 2008
  • The electric power subsystems (EPS) of most remote sensing satellites consist of a solar array as a source of energy, a storage battery, a power management and control (PMC) unit and a charge equalization unit (CEU) for the storage battery. The PMC and CEU use high frequency transformers in their power modules. This paper presents a design, implementation and testing results of a high frequency transformer for the EPS of satellite applications. Two approaches are used in the design process of the transformer based on the pre-determined transformer specifications. The transformer is designed based on an ETD 29 ferrite core. The implemented transformer consists of one center-tapped primary coil with eleven center-tapped secondary coils. The offline calculation results and measured values of R, L for transformer coils are convergence. A test circuit for measuring the transformer parameters like voltage, current and B-H hysteresis was implemented and applied. The test results confirm that the voltage waveforms of both primary and secondary coils were as desired. No overlapping occurred between the control signal and the transformer, which was not saturated during testing even during a short circuit test of the secondary channels. The dynamic B-H loop characteristics of the used transformer cores were measured. The sample test results are given in this paper.