• Title/Summary/Keyword: seawater concentration

Search Result 544, Processing Time 0.027 seconds

An integrated studies for salt-water intrusion in Yeonggwang-gun, Korea

  • Hwang Seho;Chi Sejung;Lee Won-suk;Shin Jehyun;Park Inhwa;Huh Dae-Gee;Lee Sang-kyu
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2003.11a
    • /
    • pp.455-458
    • /
    • 2003
  • A combination of drilling, hydrogeochemical survey, geophysical survey and the numerical modelling for the flow and transport of groundwater was performed to evaluate the seawater intrusion in Baeksu-eup, Yeonggwang-gun, Korea. The survey area extends to over 24 $km^2$. Twelve wells were also drilled for the collection of geologic, geochemical, hydrologic, and geophysical logging data to delineate the degree and vertical extent of seawater intrusion. To evaluate and map the salinity in a coastal aquifer, geophysical data and hydrogeochemical results were used. Layer parameters derived from VES data, various in situ physical properties from geophysical well loggings, and the estimated equivalent NaCl concentration were used as the useful input parameters for the numerical simulation with density-dependent flow. Our multidisciplinary approach for evaluating the seawater intrusion can be considered as a valuable attempt to enhancing the utilization of various data and the reliability of numerical ground modelling.

  • PDF

Measurement of Waste Generation in Seawater Aquaria by Common Conger (Astroconger myriaster) arld Olive Flounder (Paralichyhus olivaceus) (해수활어수조에서 붕장어 (Astroconger myriaster)와 넙치 (Puralichyhus olivaceus)에 의한 오염물 발생량 산정)

  • SUH Kuen-Hack;SHIN Jeong-Sik;JO Jae-Yoon
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.37 no.6
    • /
    • pp.492-497
    • /
    • 2004
  • Waste concentration and waste generation rate in seawater aquaria by common conger (Astrocongey myriaster) and olive flounder (Paralichyhus olivaceus) were investigated. The initial fish density of common conger and olive flounder were $3{\%}\;and \;2.8{\%}$ of total weight of aquarium water, respectively Wastes in the seawater aquaria, such as protein, total suspended solid (TSS), ammonia, turbidity and chemical oxygen demand (COD) increased with days after stocking. Protein generation rate of common conger increased until 1 day after stocking while that of olive flounder increased until 3 days. The average protein generation rates of common conger and olive flounder were $0.28g/kg{\cdot}day\;and\;0.21g/kg{\cdot}day$, respectively. The trends of other waste generation rate were similar to protein generation rate.

Protein Removal by a Foam Fractionator in Simulated Seawater Aquaculture System

  • Peng, Lei;Oh, Sung-Yong;Jo, Jae-Yoon
    • Ocean and Polar Research
    • /
    • v.25 no.3
    • /
    • pp.269-275
    • /
    • 2003
  • Effects of different operating factors including superficial air velocity (SAV), hydraulic residence time (HRT), protein concentration, and foam overflow height on protein removal by a foam fractionator in simulated seawater aquaculture system were investigated. This experiment was conducted on batch and consecutive modes at different combinations of the affecting factors. The foam fractionator had a diameter of 20cm and a height of 120cm and the experiment was conducted with synthetic wastewater. In 5 consecutive trials, protein concentrations in culture tank water decreased faster when the foam fractionator was operated at higher SAVs and lower HRTs. In batch trials, protein removal rates increased with an increase in SAV but decreased with an increase in URT. Higher protein concentrations in the bulk solution resulted in higher protein removal rates. Protein concentrations in the collected foam condensates increased but the foam overflow rates decreased with the increase of foam overflow heights. The results of this experiment indicate that foam fractionation would be an effective way for protein removal in seawater aquaculture systems and the performance of the foam fractionator depends largely on the operating parameters, especially SAV.

Fluoride Removal from Aqueous Solutions using Industrial Waste Red Mud (산업폐기물인 적니를 이용한 불소 제거)

  • Um, Byung-Hwan;Jo, Sung-Wook;Kang, Ku;Park, Seong-Jik
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.55 no.3
    • /
    • pp.35-40
    • /
    • 2013
  • The present study was conducted to investigate the adsorption potential of red mud for fluoride removal. Different operation parameters such as the effect of contact time, initial concentration, pH, competing anions, seawater, adsorbent dose amount, and adsorbent mixture were studied. Nearly 3 hr was required to reach sorption equilibrium. Equilibrium sorption data were described well by Langmuir model and the maximum adsorption capacity of red mud was 5.28 mg/g. The fluoride adsorption at pH 3 was higher than in the pH range 5-9. The presence of anions such as sulfate, nitrate, phosphate, and bicarbonate had no significant effect on fluoride adsorption onto red mud. The fluoride removal by red mud was greater in seawater than deionized water, resulting from the presence of calcium and magnesium ion in seawater. The use of red mud alone was more effective for the removal of fluoride than mixing red mud with other industrial waste such as oyster shells, lime stone, and steel slag. This study showed that red mud has a potential application in the remediation of fluoride contaminated soil and groundwater.

Assessment of water quality in an artificial urban canal: A case study of Songdo City in South Korea

  • Ahn, Jungkyu;Na, Yeji;Park, Sung Won
    • Environmental Engineering Research
    • /
    • v.24 no.4
    • /
    • pp.582-590
    • /
    • 2019
  • Currently, the waterfront facility was constructed in New Songdo City, South Korea. It has the various water leisure areas and especially an artificial urban canal with filtered seawater by re-circulating flow system. However, due to excessive amount of nutrients from seawater combined with complicated geometry, it is highly vulnerable to deterioration of water quality. In this study, flow characteristics and pollutant transport were analyzed with comprehensive numerical models, MIKE 3 FM and ECO-lab. Based on these numerical results, notable sampling points were selected for field measurements and comparison between modeling and measured results were conducted. In addition, the integrated water quality evaluation index, Water Quality Index was applied to analyze various water quality issues. We also set up scenarios to control the two kinds of water quality factors, dissolved oxygen (DO), and total phosphorus (TP). As a result, the effect of 20% reduction of TP was less than 10% and it was almost ineffective for a year but it was reduced by up to 40% in case of scenario which DO is increased by 20%. Therefore, it was recommended to control the DO concentration, usually by applying re-aeration facility, rather than TP in artificial urban canal with seawater.

Selective Corrosion of Socket Welds of Stainless Steel Pipes Under Seawater Atmosphere (해수분위기에서 스테인리스강 배관 소켓 용접부의 선택적 부식)

  • Boo, Myung-Hwan;Lee, Jang-Wook;Lee, Jong-Hoon
    • Corrosion Science and Technology
    • /
    • v.19 no.4
    • /
    • pp.224-230
    • /
    • 2020
  • Stainless steel has excellent corrosion resistance. The drawback is that pitting occurs easily due to the concentration of chloride. In addition, corrosion of socket weld, which is structurally and chemically weaker than the other components of the pipe, occurs rapidly. Since these two phenomena overlap, pinhole leakage occurs frequently in the seawater pipe socket welds made of stainless steel at the power plants. To analyze this specific corrosion, a metallurgical analysis of the stainless steel socket welds, where the actual corrosion occurred during the power plant operation, was performed. The micro-structure and chemical composition of each socket weld were analyzed. In addition, selective corrosion of the specific micro-structure in a mixed dendrite structure comprising γ-austenite (gamma-phase iron) and δ-ferrite (iron at high temperature) was investigated based on the characteristic micro-morphology and chemical composition of the corroded area. Finally, the different corrosion stages and characteristics of socket weld corrosion are summarized.

Metal Sequestering by a Poly(ethylenimine)-Sephadex G-25 Conjugate Containing 2,2'-Dihydroxyazobenzene

  • Gwan, Won Jong;Yu, Chang Eun;Jang, Won Seok;No, Yeong Seok;Seo, Jeong Hun
    • Bulletin of the Korean Chemical Society
    • /
    • v.21 no.4
    • /
    • pp.393-400
    • /
    • 2000
  • 2,2¢-Dihydroxyazobenzene (DHAB) was attached to poly(ethylenimine) (PEI) to obtain DHAB-PEI. Spectral titration revealed that uranyl, Fe(III), Cu(II), and Zn(II) ion form 1 : 1-type complexes with DHAB attached to PEI. Formation constants for the metal complexes formed by the DHAB moieties of DHAB-PEI were mea-sured by using various competing ligands. The results indicated thatthe concentrations of uranyl, Fe(III), and Cu(II) ions can be reduced to 10 -16 -10 -23 M at p 8 with DHAB-PEI when the concentration of the DHAB moiety is 1 residue M. By using cyanuric chloride as the coupling reagent, DHAB-PEI was immobilized on Sephadex G-25 resin to obtain DHAB-PEI-Seph. Binding of uranyl,Fe(III), Cu(II), and Zn(II) ion by DHAB-PEI-Seph was characterized by using competing ligands. A new method has been developed for characteriza-tion of metal sequestering ability of a chelating resin. Formation constants and metal-binding capacity of two sets of binding sites on the resin were estimated for each metal ion. DHAB-PI-Seph was applied to recovery of metals such as uranium,Fe, Cu, Zn, Pb, V, Mn, and W from seawater. The uranium recovery from seawaterby DHAB-PEI-Seph does not meet the criterion for economical feasibility partlydue to interference by Fe and Zn ions. The seawater used in the experiment was contaminated by Fe and Zn and, therefore, the efficiency of uranium extractionfrom seawater with DHAB-PEI-Seph could be improved if the experiment is carried out in a cleaner sea.

Characterization and Antimicrobial Resistance of Vibrio parahaemolyticus Strains Isolated from Seawater of Geum River Estuary Area, West Coast of Korea (금강 하구 해역의 해수에서 분리한 장염비브리오(Vibrio parahaemolyticus) 균의 특성 및 항균제 내성)

  • Lee, Shin-Hye;Kim, Hee-Dai;Park, Kwon-Sam
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.55 no.6
    • /
    • pp.850-857
    • /
    • 2022
  • Seventy-five Vibrio parahaemolyticus isolates from the surface seawater of the Geum River Estuary area, on the west coast of Korea, were analyzed for the presence of virulence genes and susceptibility to 17 different antimicrobials. All 75 isolates were examined for the presence of two virulence genes (tdh or trh) using polymerase chain reaction; Only one of the isolates possessed the tdh or trh gene. According to the results of disk diffusion susceptibility tests, all of the strains were resistant to penicillin G, 92.0% were resistant to ampicillin, 82.7% were resistant to amoxicillin, 2.7% were resistant to ciprofloxacin, 2.7% were resistant to trimethoprim, 1.3% were resistant to cephalothin, and 1.3% were resistant to erythromycin. However, all of the strains were susceptible to amikacin, cefoxitin, chloramphenicol, gentamycin, kanamycin, nalidixic acid, nitrofurantoin, rifampin, streptomycin, and tetracycline. The average minimum inhibitory concentrations for ampicillin for V. parahaemolyticus was 557.6 ㎍/mL. These results not only provide novel insight into the necessity for seawater sanitation in Geum river estuary area, but they help reduce the risk of contamination of antimicrobial-resistant bacteria.

Application of Limestone, Zeolite, and Crushed Concrete as Capping Material for Interrupting Heavy Metal Release from Marine Sediments and Reducing Sediment Oxygen Demand (해양퇴적물에서 중금속 용출 차단 및 퇴적물 산소 요구량 감소를 위한 석회석, 제올라이트 및 폐콘크리트의 피복 소재로서 적용)

  • Kang, Ku;Park, Seong-Jik
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.57 no.4
    • /
    • pp.31-38
    • /
    • 2015
  • This study aims to assess the effectiveness of limestone, zeolite, and crushed concrete as capping material to block the release of heavy metals (As, Cu, Cr, Ni, and Pb) and reduce the sediment oxygen demand. The efficiency of limestone, zeolite, and crushed concrete was evaluated in a reactor in which a 1-cm thick layer of capping materials was placed on the sediments collected from Inchon north harbor. Dissolved oxygen concentration and heavy metal concentration in seawater above the uncapped sediments and capping material were monitored for 17 days. The sediment oxygen demand was in the following increasing order: crushed concrete ($288.37mg/m^2{\cdot}d$) < zeolite ($428.96mg/m^2{\cdot}d$) < limestone ($904.53mg/m^2{\cdot}d$) < uncapped ($981.34mg/m^2{\cdot}d$). The capping materials could reduce the sediment oxygen demand by blocking the release of biochemical matters consuming dissolved oxygen in seawater. It was also shown that zeolite and crushed concrete could effectively block the release of Cu, Ni, and Pb but those were not effective for the interruption of As and Cr release from marine contaminated sediments.

A Study on the Solid-Liquid Separation of Cooling Water in Ships (선박용 냉각수의 고.액분리에 관한 연구)

  • Choi, M.S.;Kim, J.H.;Jo, D.H.;Han, W.H.;Kim, B.G.
    • Journal of Power System Engineering
    • /
    • v.7 no.4
    • /
    • pp.25-30
    • /
    • 2003
  • Hydrocyclone has been widely used for the solid-Liquid separation in many industrial sites because of its comparatively preferable applications that can be applied to wide-range panicle sizes. If seawater with impurities flows through pumps or heat exchanger, it might cause an decrease in efficiency of cooling system. In this paper, we have suggested solid methods of separating impurities from seawater in the cooling system by using a Hydrocyclone. The effects of design factors as solid concentration, cyclone inlet pressure, flow rate and diameter of underflow on the seperating performance of the Hydrocyclone were investigated. The results from the study are summarized as follows: 1) In proportion to the increase of solid concentration, the efficiency of solid-liquid separation is improved. 2) According as the cyclone inlet pressure increases the efficiency of separation is improved. Conclusively, this research suggested that the Hydrocyclone will be used as a pre-treatment system of cooling water in ships, and eventually prevent unexpected accidents in engine systems.

  • PDF