• Title/Summary/Keyword: seating components

Search Result 3, Processing Time 0.015 seconds

A Comparison Study for Wheelchair Seating System between Wheelchair Users with Cerebral Palsy and Spinal Cord Injuries (외상성 척수손상장애인과 뇌성마비장애인의 맞춤형 전동휠체어 적용 시 착석시스템의 차이에 대한 연구)

  • Yoo, S.M.;Cho, K.R.;Lim, M.J.;Kim, J.B.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.3 no.1
    • /
    • pp.49-53
    • /
    • 2009
  • In this paper, we compared wheelchair seating system between wheelchair users with cerebral palsy and spinal cord injuries. Wheelchair seating system is divided into three parts, seating components, seating cushion, and special functions. Seating components are composed of 10 sections, such as headrest, footrest, etc. There are 4 seating cushions including gel, form, hybrid, and air. Also leg elevation, seat elevation, tilt-in-space, reclining, and standing are special function of the wheelchair. There are 10 wheelchair users, 5 with celebral palsy, and 5 with spinal cord injuries who have participated in this study. 10 wheelchair users have been customers of rehabilitation technology center in national rehabilitation center. On the result, SCI group mostly uses headrest, and Humeral blocks (seating components), air cushion (seating cushion), and tilt in space, reclining (special functions). On the other hand, CP group uses adductor, abductor, and pommel (seating components), form cushion (seating cushion), and some of CP group uses reclining (special functions)

  • PDF

The Design of long cantilever beam using post-tensioned tendons in Kumjung Stadium (포스트텐션을 이용한 장스팬 켄틸레버보의 설계)

  • 최동섭;김동환;김종수
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.10a
    • /
    • pp.619-624
    • /
    • 2002
  • A prestressed/precast concrete system was used to build the new Asian Olympic Stadium Project in Pusan, Korea. The stadium(mainly intended for cycle racing) is designed for the 2002 Asian Olympic Games and has a seating capacity of 20,000 spectators plus a few private suites. More than 1300 prestressed/precast components were used and they include single columns, primary beams, cantilever beams, double riser stands, and double tees. Especially, a total of 24 cantilever beams is used on the fourth story for the stands and double tees. These 8m long beams are post-tensioned to prevent cracking, to increase their durability and to serve serviceability by vibration. A cantilever section with cast-in-place topping is 800mm wide and 1500mm deep. Cantilever beams are connected to the column with the corbel by cast-in place concrete. Bonded post-tensioning tendons were assembled at the job site. Dead-end anchorages were installed in the end of cantilever beams and live-end anchorage is the opposite of them. This article presents the geometric layouts, design features and so on.

  • PDF

Screw joint stability according to abutment screw materials

  • Jeong Yong-Tae;Chung Chae-Heon;Lee Heung-Tae
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.3
    • /
    • pp.297-305
    • /
    • 2001
  • Statement of problem. There have been previous studies about instability according to screw material by means of calculating preload in tightening screw or recording of the torque necessary to loosen screw after tightening screw. Purpose. The purpose of this study was to evaluate screw joint stability through the analysis of fitness at the mating thread surfaces between implant and screw after tightening screws made of different materials. Material and methods. In this study, screws were respectively used to secure a cemented abutment to a hexlock implant fixture; teflon coated titanium alloy screw and titanium alloy screw(Steri-Oss), gold-plated gold-palladium alloy screw and titanium alloy screw(Implant Innovation), gold screw and titanium screw(AVANA Dental Implant System). Each abutment screw was secured to the implant with recommended torque value using a digital torque controller. Each screw was again tightened after 10minutes. All samples were cross sectioned with sandpaper and polished. Then samples were evaluated with an scanning electron microscope analysis. Results. In titanium alloy screw, irregular contact and relatively large gap was present at mating thread surface. Also in teflon-coated titanium screw, incomplete seating and only partially contact was present at the mating thread surface. In gold-plated gold-palladium alloy screw, relatively close and tight contact without the presence of large gap was present by existing of gold coating at the mating thread surfaces. In gold alloy screw, relatively small gap between the mating components was seen. Conclusions. This result suggested that gold plated gold-palladium alloy screw and gold alloy screw achieved a greater degree of contact at the mating thread surfaces compared to titanium alloy screw and teflon-coated titanium alloy screw.

  • PDF