• Title/Summary/Keyword: sealants

Search Result 133, Processing Time 0.031 seconds

Assessment of the Hydraulic Conductivity of the Furnace Slag Coated with the Mixture of Bentonite-sepiolite-guargum under Sea Water Condition (벤토나이트-해포석-구아검 혼합물질이 코팅된 제강슬래그의 해수에 대한 투수성 평가)

  • Cheong, Eui-Seok;Rhee, Sung-Su;Woo, Hee-Soo;Park, Jun-Boum
    • Journal of Soil and Groundwater Environment
    • /
    • v.16 no.4
    • /
    • pp.1-9
    • /
    • 2011
  • Bentonite has been generally used as vertical cutoff barrier material and reported to have several problems regarding its low workability, drying shrinkage cracking by particle cohesion, and ineffective waterproof ability under sea water condition. In this study, the particle sealant, the furnace slag coated by the mixture of bentonite, sepiolite and guargum, was developed to compensate these weak points and the hydraulic conductivity of the particle sealant was evaluated. Drying shrinkage cracking and swelling index was estimated to find the optimal mixing ratio of bentonite, sepiolite and guargum. The hydraulic conductivity of the particle sealants having different amount of sealant (bentonite-sepioliteguargum mixture) coating the furnace slag was estimated using the rigid wall permeameter and flexible wall permeameter. The results showed that drying shrinkage cracking was not found in the bentonite-sepiolite mixture with 20% sepiolite contents and the results from free swelling tests for the sealant having 1 : 0.025, 1 : 0.05 and 1 : 0.075 of weight ratios of bentonite-sepiolite mixture and guargum under simulated sea water condition were higher than those for the bentonitesepiolite mixture without guargum under tap water condition. These three sealants were coated on the furnace slag with 50% and 60% of sealant in the particle sealant and the hydraulic conductivity was estimated. In the cases of the particle sealants having 20% sepiolite in the bentonite-sepiolite mixture and 1 : 0.075 weight ratio of the bentonite-sepiolite mixture and guargum, the hydraulic conductivity from the rigid wall permeameter was below $1.0{\times}10^{-7}$ cm/sec under simulated sea water condition. The hydraulic conductivity of the particle sealant having $1.0{\times}10^{-6}$~$1.0{\times}10^{-7}$ cm/sec by the rigid wall permeameter was estimated using the flexible wall permeameter and found to be below $1.0{\times}10^{-7}$ cm/sec.

In Vitro Evaluation of Microleakage and Penetration of Hydrophilic Sealants Applied on Dry and Moist Enamel (법랑질 수분 처리에 따른 친수성 치면열구전색제의 미세누출과 열구 침투도 평가)

  • Ku, Jaewon;Lee, Jewoo;Ra, Jiyoung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.44 no.3
    • /
    • pp.272-279
    • /
    • 2017
  • This study aimed to evaluate the microleakage and penetration of two hydrophilic sealants, Embrace $Wetbond^{TM}$ and Ultraseal $XT^{(R)}$ $hydro^{TM}$, when applied on dry and moist enamel, as compared to a conventionally used hydrophobic sealant, $Clinpro^{TM}$. A total of 60 sound human third molars were randomly divided into 5 groups according to the enamel moisture control and the sealant material used. After sealant application, the teeth were thermocycled and immersed in 1% methylene blue dye. Subsequently, the teeth were sectioned twice and the sections were examined using an optical microscope and image analysis software. Application of Embrace $Wetbond^{TM}$ on either dry or moist enamel resulted in more microleakage than $Clinpro^{TM}$. Application of Ultraseal $XT^{(R)}$ $hydro^{TM}$ on dry enamel showed a similar level of microleakage to $Clinpro^{TM}$, but application on moist enamel resulted in more microleakage. There were no significant differences between the groups in penetration. In conclusion, application of hydrophilic sealants on moist enamel did not improve the sealing ability and showed lower sealing ability than that of $Clinpro^{TM}$ applied on dry enamel.

A STUDY ON THE MICROLEAKAGE OF PIT AND FISSURE SEALANTS WITH DIFFERENT FILLING AMOUNT (치면열구전색재의 충전량에 따른 미세누출의 비교연구)

  • Park, Soo-Jin;Jung, Tae-Sung;Kim, Shin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.2
    • /
    • pp.238-244
    • /
    • 2003
  • With the purpose of evaluating the effect of ailing amount of pit and assure sealants on the microleakage, 6 groups of specimens with different filling amount, filling materials and surface pretreatment were investigated. Sixty permanent third molars were divided into three groups. The occlusal surface of each tooth was divided into two parts; the filing width of one part was below 1mm (group1, 3, 5), and in the other part more than 2mm (group 2, 4, 6) Group 1 and 2: Helioseal F was applied directly to etched enamel; Group 3 and 4: Helioseal F was applied to etched and scotchbond Multi-purpose plus pre-treated enamel; Group 5 and 6: Tetric Flow was applied. After 500 times thermocycling and dye infiltration, we evaulated the microleakage. The results were as follows; 1. The mean microleakage score at each width were increased in the following order;group 5<3<1, and group 6<4<2. 2. In comparing the groups with same material and surface pretreatment but with different filling width (group 1 versus 2, 3 versus 4, 5 versus 6), the microleakage scores were significantly different. 3 The microleage was affected by filling amount of pit and assure sealants than Oiling materials and dentin bonding agent pretreatment.

  • PDF

EVALUATION OF THREE FLOWABLE COMPOSITES AS PIT AND FISSURE SEALANTS WITHOUT USING BONDING AGENTS (접착제 미 사용시 치면열구전색제로서의 유동성 복합레진 평가)

  • Kwon, Ho-Beom;Kim, Myoung-Jin;Shin, Cheol-Hwan;Kim, Ji-Yeon;Park, Ki-Tae
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.2
    • /
    • pp.244-252
    • /
    • 2006
  • The aims of this study were to determine if flowable composites can be used as pit and fissure sealants without bonding agents. Three flowable composites(Filtek Flow, Tetric Flow, Charmfil Flow) and a filled sealant (Ultraseal XT plus) were used. The pattern of resin tag formation in the four sealant materials were compared using SEM. For the microleakage assessment, 54 extracted human premolar teeth were randomly divided into 3 groups containing 18 premolars each. In each group, a conventional filled sealant and one of the three flowable composites were applied to occlusal fissures. The teeth were thermocycled(1200 cycles between $5^{\circ}{\pm}2^{\circ}C\;and\;55^{\circ}{\pm}2^{\circ}C$ with a dwell time of 30 seconds) and immersed in a 1% methylene blue solution for 48 hours. Each tooth was sectioned and examined to determine the extent of dye penetration. Three flowable composites and a filed sealant showed a similar resin tag formation pattern. The three flowable composites showed significantly more microleakage in each group than the filled sealant. The level of microleakage was similar in the three flowable composites. Flowable composites are not recommended as pit and fissure sealants because more microleakage can occur even when occlural fissures are mechanically widened.

  • PDF

Fabrication and Characterization of Composite Sealants for Low Temperature (600∼650°C)SOFCs (저온작동 (600∼650°C) SOFC용 복합밀봉재 제조 및 평가)

  • Lim, Hyun-Yub;Kim, Hyoung-Chul;Choi, Sun-Hee;Kim, Hae-Ryoung;Son, Ji-Won;Lee, Hae-Weon;Lee, Jong-Ho
    • Journal of the Korean Ceramic Society
    • /
    • v.45 no.12
    • /
    • pp.802-806
    • /
    • 2008
  • A proper sealant for low temperature SOFCs should show zero or low leak rates to avoid direct mixing of the fuel and oxidant gases or leakage of fuel gas during the operation of SOFCs. Furthermore, it should be chemically and/or mechanically stable in both oxidizing and reducing environments and chemically compatible with other fuel cell components. In the present work, we developed a novel compressed seal gasket of glass-based composite reinforced with ceramic particulate particles, which can efficiently control the viscous flow of glass matrix as well as the crystallization of glass phase. This novel sealing gasket showed excellent gas tightness under very low compressive load which would be suitable for the operation of SOFCs in the temperature range $600{\sim}650^{\circ}C$.

EARLY CONNECTIVE TISSUE ATTACHMENT ON DENTIN SURFACE TREATED WITH CITRIC ACID, TETRACYCLINE AND FIBRIN SEALANTS (구연산, 테트라싸이클린, 섬유소 전색제로 처리된 상아질면에 대한 결체조직의 조기부착)

  • Lee, Hea-Ja;Han, Soo-Boo;Ko, Jae-Sung
    • Journal of Periodontal and Implant Science
    • /
    • v.23 no.2
    • /
    • pp.283-299
    • /
    • 1993
  • The purpose of this study was to observe early connective tissue attachment on dentin surface treated with citric acid, tetracycline, and fibrin sealants and compare their conditioning effects on dentin surface. Experimental dentin blocks conditioned with citric acid, tetracycline or fibrin sealant, and only root planned control block were surgically implanted in the pouch under buccal mucoperiosteal flaps of left mandible, right maxilla, left maxilla, right mandible of 18 male rabbits. Rabbits were sacrificed after 1 and 6 hours, 1, 3, 7 and 14 days after implantation and then specimens including dentin block and surrounding soft tissue were obtained, and prepared for light and transmission electron microscopic examination. 1 and 6 hours after dentin block implantation, there was plasma proteins adsorption followed by fibrin clot formation and no differences among specimens. At the 1-day observation interval, delicate fibrin network was observed in the all groups, and there were proliferative fibroblasts, angiogenesis and macrophage in the all 3-day specimens. Cellular aggregates and abundant connective tissue adhered dentin surface and tetracycline or citric acid treated group showed much proliferative fibroblast and abundant collagen fibers at 1 week. But at 2 week, citric acid treated group showed much proliferative fibroblast and abundant collagen fibers. These observations suggested that new connective tissue attachment to dentin was initiated by the adsorption of plasma proteins to the dentin surface and followed by fibrin clot formation. Tetracycline and citric acid seemed to make dentin surface more biologically favorable for the connective tissue attachment.

  • PDF

Fundamental Study on Development of Sealants used for WIM Sensor Installation (WIM 센서 설치에 적합한 실런트 개발을 위한 기초적인 연구)

  • Lim, Chisoo;Kim, Du-Byung;Kim, Yongjoo;Lee, Kanghun;Lee, Jaejun
    • International Journal of Highway Engineering
    • /
    • v.19 no.2
    • /
    • pp.17-24
    • /
    • 2017
  • PURPOSES : This study aims to develop a sealant for use in the installation of Weigh-In-Motion (WIM) sensor for asphalt concrete or cement concrete pavements. METHODS : In order to investigate the properties of various sealants that were mixed with latex and carbon fiber, various test methods were adopted, such as bituminous bond strength test, softening point test, and cone penetration test. To evaluate moisture susceptibility, the BBS test was conducted under moist condition. The bond strength ratio (BSR) was calculated based on tensile strength ratio method. RESULTS : The sealant's properties significantly varied according to the amount of latex or carbon fiber. The usage of latex marginally enhanced the cone penetration test result, notwithstanding reduced asphalt content. This implies that the sealant will be proper cold temperature reason. Moreover, the addition of latex and carbon fiber evidently increased the softening point. This indicates that the tendency of the material to flow at elevated temperatures is encountered during service. With the addition of latex and carbon fiber, the moisture susceptibility measured with BSR improved marginally, while the bond strength under dry condition decreased marginally. Sealant F displays the highest bond strength and BSR under limited test conditions. CONCLUSIONS : According to the proportion of latex and carbon fiber mixed, properties of sealant, such as softening point, cone penetration, and BSR varied marginally. This indicates that the sealant has to be applied considering the environmental condition, to improve service life.

The recognition on toothbrushing facilities and job status of facility workers in school dental clinic (학교구강보건실 담당자의 업무 실태 및 양치시설에 대한 의견 조사)

  • Jung, Jae-Yeon;Kim, Soo-Hwa;Han, Su-Jin
    • Journal of Korean society of Dental Hygiene
    • /
    • v.12 no.4
    • /
    • pp.723-732
    • /
    • 2012
  • Objectives : This study aims to analyze the tasks, recognition and obstacles in operation of school dental clinics and to examine opinions on installation, operation and prerequisites for toothbrushing facilities. Methods : It conducted a survey t o the persons in charge at 378 school dental clinics in Korea and total 127 sheets, excluding incompletely answered data, were used for analysis by using SPSS 18.0. Results : Two regular dental hygienists visit school dental clinics 2-3 times per week and work 4-6 hours per week on average. Their tasks include oral health education, toothbrushing instruction, oral examination, sending school newsletters, and dental sealants. The obstacles of operation include excessive workload other than the work for the school dental clinic, lack of dentists, and lack of cooperation of principals and teachers in school. The persons in charge think that the chief task of the school dental clinic is the continuous oral health management, and it effectively affects students' oral health improvement. Most of them were for the installation of toothbrushing facilities. They said that it will be effective in students having an adequate toothbrushing habit and their toothbrushing rate increasing higher. They thought that if the school dental clinic is changed to toothbrushing facilities, it will improve students' oral health management. The prerequisites for toothbrushing facilities are the support of manpower in charge, principal's support, and development of operational programs. Conclusions : The most effective function of school dental clinics is constant oral health management. However, when public health doctors are reduced and dental sealants get included in health insurance, the budget of local government will decrease and then it will eventually reduce the work of school dental clinics. Therefore, it is needed to enhance support for school dental clinics or install a toothbrushing facilities rather than a school dental clinic.

Strength Development and Carbonation Characteristics of Slag Cement/Class C Fly Ash blended CO2 Injection Well Sealant

  • Kim, Tae Yoo;Hwang, Kyung-Yup;Hwang, Inseong
    • Journal of Soil and Groundwater Environment
    • /
    • v.21 no.2
    • /
    • pp.29-37
    • /
    • 2016
  • CO2 injection well sealant is vulnerable to supercritical CO2 (scCO2) exposure. To develop an alternative to the conventional sealant system (class G cement/class F fly ash), the performance of slag cement (SPC) systems containing class F fly ash (FFA) or class C fly ash (CFA) was evaluated and compared with the conventional sealant under scCO2 conditions. All sealant systems showed an immediate increase in compressive strength upon scCO2 exposure and, at 37.6 MPa, SPC/CFA showed the highest compressive strength after 14 days, which was much higher than the 29.8 MPa of the conventional sealant system. Substantial decreases in porosity were observed in all sealant systems, which were partly responsible for the increase in strength. Carbonation reactions led to pH decreases in the tested sealants from 12.5 to 10~11.6. In particular, the greatest decrease in pH in slag cement/class C fly ash probably supported relatively sustainable alkali activation reactions and the integrity of cement hydrates in this system. XRD revealed the presence of CaCO3 and a decrease in the content of cement hydrates in the tested sealants upon scCO2 exposure. TGA demonstrated a greater increase of CaCO3 and calcium-silicate-hydrate phases in SPC/CFA than in the conventional sealant upon scCO2 exposure.

Evaluation of High-power Light Emitting Diode Curing Light on Sealant Polymerization (고출력 발광 다이오드 광중합기의 치면열구전색제 중합능 평가)

  • Park, Youngjun;Lee, Jewoo;Ra, Jiyoung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.46 no.1
    • /
    • pp.57-63
    • /
    • 2019
  • This study aimed to determine whether the curing times of Xtra Power and High Power modes of high-power light emitting diode (LED) curing light are sufficient for polymerization of resin sealants. The specimens were prepared and their microhardness values were measured and compared with those of specimens polymerized under conventional LED curing light. The filled sealant polymerized for 8 seconds in the High Power mode and for 3 seconds in the Xtra Power mode showed significantly lower microhardness than the control specimen (p = 0.000). The unfilled sealant polymerized for 8, 12 seconds in the High Power mode and for 6 seconds in the Xtra Power mode showed significantly lower microhardness than the control specimen (p = 0.000). The results of this study suggest that the short curing time with the Xtra Power and High Power modes of highpower LED curing light are not sufficient for adequate polymerization of sealants under specific conditions, taking into account the curing times and the type of sealant.