• Title/Summary/Keyword: sd-system

Search Result 1,031, Processing Time 0.029 seconds

Network Neutrality in the Digital Convergence Era : a System Dynamics Model with Two-Sided Market Framework (디지털 컨버전스 환경에서 양면시장 플랫폼으로서의 인터넷망 중립성에 관한 동태적 분석)

  • Kim, Do-Hoon
    • Journal of Information Technology Services
    • /
    • v.10 no.2
    • /
    • pp.75-94
    • /
    • 2011
  • The industrial ecosystem around the Internet services has been evolving since the Internet was first introduced. The Net Neutrality issue best represents the process of the evolution and presents an inevitable challenge that the industry should overcome. This paper deals with this structural change with the Two-Sided Market framework and provides a System Dynamics(SD) model to evaluate the economic implications of the net neutrality policy. In particular, our approach analyzes the policy impacts when two competing platforms (network providers) play a role of the platform in a typical two-sided market, which connects Content Providers(CPs) with users. Previous studies show that the indirect network externality between these two markets makes the entire system tip to one platform. When the multi-homing in the CP market is allowed as in our model, however, their argument may lose its validity. To examine the system behavior, conducted here is SD simulations of our model. The simulation results show that co-existence of the competing platforms persists with the network effects over a certain threshold. The net neutrality policy seems to lower the threshold based on our experimental outcomes.

Development of a System Dynamics Model For Estimating the Volume of Forest Resources and Function of Public Benefit (산림자원 및 산림의 공익기능량 추정을 위한 시스템다이내믹스 모형 개발)

  • Cho, Yoon-Sook
    • Korean System Dynamics Review
    • /
    • v.15 no.3
    • /
    • pp.5-36
    • /
    • 2014
  • The purpose of this paper is to develop a System Dynamics model for estimating the volume of forest resources in the future and simulating the volume of function of public benefit linked to forest resources in dynamic manner. Also it is to analyze the impact when the volume of forest land conversion is controlled by policy using the SD model. The analysis was done at nation-wide for the simulation period 2000 to 2040. Estimated forest area was 6.2 million ha and estimated growing stock was $4.7\;billion\;m^3$ in 2040 from the future forecast without policies. Changing of forest resources, 13.9 billion tons of forest-ground-water storage was estimated, $1.8\;million\;m^3$ of erosion control of forest was estimated and 377 million tons of $CO_2$ absorption was estimated. As a result of simulation with two alternatives, forest area was less reduced and growing stock was bigger than do nothing policy. Also, function of public benefit reflected by changes of forest resources was enhanced. This study contributes to estimate the quantitatively measured volume of forest resources and function of public benefit over the 30 years in Korean forest land in scientific way. Using this SD model, decision maker would develop forest land policies more delicately for deserving forest resources and increasing the volume of function of public.

  • PDF

Study of Small and Medium-Sized VDR Device with Camera and Data Control Method for Efficiency Garantee of Ship Navigation System (선박 네비게이션 시스템의 효율성 보장을 위한 카메라 장착 중소형 VDR장치 및 데이터 제어방법 연구)

  • Min, Byung Guk;Ha, Tae Jin;Kim, Young Soo;Park, Jung Min;Cha, Jun Sub
    • Smart Media Journal
    • /
    • v.2 no.1
    • /
    • pp.42-47
    • /
    • 2013
  • The paper presents VDR system for efficiency of ocean navigation device and how to output and to save data using this system as well as compressed digital data and analog video output from the camera are utilized at the same time. The compressed digital data is used to store video for VDR device while analog video is used to display on screen in real-time so that VDR system saves the load on SD memory card without navigation terminal and output it with real-time video. Also, the control method using VDR system are proposed for saving and outputting data.

  • PDF

Boarding environment of training ship KAYA for the hull vibration (실습선 가야호의 선체진동에 대한 승선환경)

  • Kim, Min-Son;Shin, Hyeon-Ok;Kim, Min-Seok;Han, Jin-Seok
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.45 no.1
    • /
    • pp.46-55
    • /
    • 2009
  • To compare and evaluate the suitability and comfort levels of the environment on board a stern trawl training ship, KAYA(GT: 1737 tons, Pukyong National University), with the international standardization guide ISO 6954:2000(E), measurements of the hull vibration on accommodation areas and working areas of the training ship from July 8 to July 10, 2008 were completed upon KAYA's linear sea route. The vibrations along the z-axis were measured with the use of a 3-axis vibration level meter, which included a marine vibration card. Results show accelerations of the vibrations on the passenger's accommodation area to be 42.0-115.8(average: 78.0, standard deviation(SD): 21.0) mm/$s^2$, which is largely below the permissible upper limit, but 75 % of the observation points exceeded the permissible lower limit of 71.5 mm/$s^2$, indicating a comfortable environment. The accelerations of the vibration in a frequency of 10-24Hz lowering the visual performance were measured at 2.5-12.0(average: 7.6, SD: 3.1) mm/$s^2$. The crew s accommodation area experienced vibration accelerations of 42.9-82.3(average: 93.1, SD: 53.1) mm/$s^2$, which is generally below the permissible upper limit of 214.0 mm/$s^2$, and 62.5% of the observation points did not exceed the permissible lower limit of 107.0 mm/$s^2$, denoting a level of comfort. The acceleration of the vibration in a frequency of 10-24Hz were 4.7-28.3(average: 12.4, SD: 8.8) mm/$s^2$. On the crew s working area the accelerations were measured at 86.9-153.9(average 119.3, SD 18.0) mm/$s^2$. These values were generally below the permissible upper limit of 286.0 mm/$s^2$ and only 12.5% of the observation points did not exceed the permissible lower limit of 143.0 mm/$s^2$, the level at which a high level of comfort is maintained. The accelerations in frequency of 10-24Hz and 30Hz were 9.1-29.8 (average 13.8, SD= 4.5) mm/$s^2$ and 8.9-13.7 (average 11.8, SD 2.1) mm/$s^2$, respectively. In conclusion the boarding environment of the training ship was good in general although an improvement of the vibration condition partially needed on the crew s accommodation area near the engine room.

Comparison of Diagnostic Accuracy and Prediction Rate for between two Syndrome Differentiation Diagnosis Models (중풍 변증 모델에 의한 진단 정확률과 예측률 비교)

  • Kang, Byoung-Kab;Cha, Min-Ho;Lee, Jung-Sup;Kim, No-Soo;Choi, Sun-Mi;Oh, Dal-Seok;Kim, So-Yeon;Ko, Mi-Mi;Kim, Jeong-Cheol;Bang, Ok-Sun
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.23 no.5
    • /
    • pp.938-941
    • /
    • 2009
  • In spite of abundant clinical resources of stroke patients, the objective and logical data analyses or diagnostic systems were not established in oriental medicine. In the present study we tried to develop the statistical diagnostic tool discriminating the subtypes of oriental medicine diagnostic system, syndrome differentiation (SD). Discriminant analysis was carried out using clinical data collected from 1,478 stroke patients with the same subtypes diagnosed identically by two clinical experts with more than 3 year experiences. Numerical discriminant models were constructed using important 61 symptom and syndrome indices. Diagnostic accuracy and prediction rate of 5 SD subtypes: The overall diagnostic accuracy of 5 SD subtypes using 61 indices was 74.22%. According to subtypes, the diagnostic accuracy of "phlegm-dampness" was highest (82.84%), and followed by "qi-deficiency", "fire/heat", "static blood", and "yin-deficiency". On the other hand, the overall prediction rate was 67.12% and that of qi-deficiency was highest (73.75%). Diagnostic accuracy and prediction rate of 4 SD subtypes: The overall diagnostic accuracy and prediction rate of 4 SD subtypes except "static blood" were 75.06% and 71.63%, respectively. According to subtypes, the diagnostic accuracy and prediction rate was highest in the "phlegm-dampness" (82.84%) and qi-deficiency (81.69%), respectively. The statistical discriminant model of constructed using 4 SD subtypes, and 61 indices can be used in the field of oriental medicine contributing to the objectification of SD.

A Dosimetric Evaluation of Large Pendulous Breast Irradiation in Prone Position (Large Pendulous Breast 환자의 방사선 치료에 있어서 엎드린 자세의 유용성 평가)

  • Hong, Chae-Seon;Ju, Sang-Gyu;Park, Ju-Young
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.20 no.1
    • /
    • pp.37-43
    • /
    • 2008
  • Purpose: To evaluate dosimetry results of three different techniques for whole breast irradiation after conservative surgery of large pendulous breast patient. Materials and Methods: Planning computed tomography (CT) scans for three techniques were performed on a GE Hi-speed advantage CT scanner in the supine (SP), supine with breast supporting Device (SD) and prone position on a custom prone mattress (PP). Computed tomography images were acquired at 5 mm thickness. The clinical target volumes (CTV), ipsilateral lung and heart were delineated to evaluate the dose statistic, and all techniques were planned with the tangential photon beams (Pinnacle$^3$, Philips Medical System, USA). The prescribed dose was 50 Gy delivered in 25 fractions. To evaluate the dose coverage for CTV, we analysed percent volume of CTV receiving minimum of 95%, 100%, 105%, and 110% of prescription dose ($V_{95}$, $V_{100}$, $V_{105}$, and $V_{110}$) and minimal dose covering 95% ($D_{95}$) of CTV. The dosimetric comparison for heart and ipsilateral lung was analysed using the minimal dose covering 5% of each organs ($D_5$) and the volume that received >18 Gy for the heart and >20 Gy for the ipsilateral lung. Results: Target volume coverage ($V_{95}$ and $V_{100}$) was not significantly different for all technique. The V105 was lower for PP (1.2% vs. 4.4% for SP, 11.1% for SD). Minimal dose covering 95% ($D_{95}$) of target was 47.5 Gy, 47.7 Gy and 48 Gy for SP, SD and PP. The volume of ipsilateral lung received >20 Gy was 21.7%, 11.6% and 4.9% for SP, SD and PP. The volume of heart received >18 Gy was 17.0%, 16.1% and 9.8% for SP, SD and PP. Conclusion: Prone positioning of patient for large pendulous breast irradiation enables improving dose uniformity with minimal heart and lung doses.

  • PDF

Associations Between Heart Rate Variability and Symptom Severity in Patients With Somatic Symptom Disorder (신체 증상 장애 환자의 심박변이도와 증상 심각도의 연관성)

  • Eunhwan Kim;Hesun Kim;Jinsil Ham;Joonbeom Kim;Jooyoung Oh
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.31 no.2
    • /
    • pp.108-117
    • /
    • 2023
  • Objectives : Somatic symptom disorder (SSD) is characterized by the manifestation of a variety of physical symptoms, but little is known about differences in autonomic nervous system activity according to symptom severity, especially within patient groups. In this study, we examined differences in heart rate variability (HRV) across symptom severity in a group of SSD patients to analyze a representative marker of autonomic nervous system changes by symptoms severity. Methods : Medical records were retrospectively reviewed for patients who were diagnosed with SSD based on DSM-5 from September 18, 2020 to October 29, 2021. We applied inverse probability of treatment weighting (IPTW) methods to generate more homogeneous comparisons in HRV parameters by correcting for selection biases due to sociodemographic and clinical characteristic differences between groups. Results : There were statistically significant correlations between the somatic symptom severity and LF (nu), HF (nu), LF/HF, as well as SD1/SD2 and Alpha1/Alpha2. After IPTW estimation, the mild to moderate group was corrected to 27 (53.0%) and the severe group to 24 (47.0%), and homogeneity was achieved as the differences in demographic and clinical characteristics were not significant. The analysis of inverse probability weighted regression adjustment model showed that the severe group was associated with significantly lower RMSSD (β=-0.70, p=0.003) and pNN20 (β=-1.04, p=0.019) in the time domain and higher LF (nu) (β=0.29, p<0.001), lower HF (nu) (β=-0.29, p<0.001), higher LF/HF (β=1.41, p=0.001), and in the nonlinear domain, significant differences were tested for SampEn15 (β=-0.35, p=0.014), SD1/SD2 (β=-0.68, p<0.001), and Alpha1/Alpha2 (ß=0.43, p=0.001). Conclusions : These results suggest that differences in HRV parameters by SSD severity were showed in the time, frequency and nonlinear domains, specific parameters demonstrating significantly higher sympathetic nerve activity and reduced ability of the parasympathetic nervous system in SSD patients with severe symptoms.

Effects for Running Shoes with Resilience of Midsole on Biomechanical Properties (미드솔의 반발탄성이 러닝화의 생체역학적 특성에 미치는 영향)

  • Yoo, Chan-Il;Won, Yonggwan;Kim, Jung-Ja
    • Korean Journal of Applied Biomechanics
    • /
    • v.25 no.1
    • /
    • pp.103-111
    • /
    • 2015
  • Objective : The purpose of this study was to evaluate the effect for running shoes with resilience of midsole on biomechanical properties. Methods : 10 healthy males who had no history of injury in the lower extremity with an average age of 26.5 year(SD=1.84), height of 172.22 cm(SD=4.44) and weight of 67.51 kg(SD=6.17) participated in this study. All subjects ran on the treadmill wearing three different running shoes. Foot pressure data was collected using Pedar-X system(Novel Gmbh, Germany) operating at 100 Hz. Surface EMG signals for biceps femoris, rectus femoris, vastus lateralis, medial lateralis, tibialis anterior, medial gastrocnemius, soleus and peroneus longus were acquired at 1000 Hz using Bignoli 8 System(Delsys Inc., USA). To normalize the difference of the magnitude of muscle contractions, it was expressed as a percentage relative to the maximum voluntary contraction (MVC). The impact resilience of the midsole data was collected using Fastcam SA5 system(Photron Inc., USA). Collected data was analyzed using One-way ANOVA in order to investigate the effects of each running shoes. Results : TPU midsole was significantly wider in contact area than EVA, TPE midsole in midfoot and higher in EMG activity than EVA midsole at biceps femoris. TPE midsole was significantly wider in contact area than EVA midsole in rearfoot and higher in peak pressure than EVA midsole in forefoot. EVA midsole was significantly higher in EMG activity than TPU midsole at tibia anterior. In medial resilience of midsoles, TPE midsole was significantly higher than EVA, TPU midsole. Conclusion : TPU midsole can reduce the load on the midfoot effectively and activate tibialis anterior, biceps femoris to give help to running.