• 제목/요약/키워드: screws

검색결과 646건 처리시간 0.023초

임플란트 생체금속들과 골조직간의 생체적합도에 관한 연구 (BICOMPATIBILITY OF BICOMTALS IN RABBIT BONE)

  • 한종현;허성주;정종평;구영;류인철;최용창
    • 대한치과보철학회지
    • /
    • 제35권3호
    • /
    • pp.557-565
    • /
    • 1997
  • Screw-shaped implants of commercially pure (c.p.) titanium, c.p. niobium, c.p. zirconium, and stainless steel(Sus 304) were inserted in the rabbit tibial bone over 12 weeks of follow-up. New developed torque gauge instrument was used to evaluate the implant holding power and a image analysis program coupled to a microscope was used for histomorphometry. The three best consecutive threads of each implant were measured. Quantitative analyses at 12 weeks revealed a partial bone contact to the four kinds investigated metals. There were no obvious adverse tissue reactions to any of the biomaterials. At 12 weeks the average removal torques for titanium, niobium and zirconium were better than that needed for Sus 304 screws, on the other hand high score of bony contact ratio of titanium and niobium were showed in comparison to those of zirconium and Sus 304. There was no significant differences in the amount of interfacial bone of zirconium and Sus 304 whereas there was significant difference in the torque forces of niobium and Sus 304. Three months after implant insertion, the average removal torque was 6.64 Ncm for the titanium, 6.57 Ncm for the niobium, 6.38 Ncm for the zirconium, and 4.25 Ncm for the Sus 304. On average bone contacts there were 51.24% in the titanium, 48.19% in the niobium, 31.79% in the zirconium, 23.54% in the Sus 304. Biocompatibility of the titanium, niobium and zirconium was acceptable level in comparison to the Sus 304.

  • PDF

개방형과 폐쇄형 임플랜트 매식후 주위골 형성에 관한 실험적 연구 (A STUDY ON THE BONE FORMATION OF OPEN TYPE AND CLOSED TYPE IMPLANTS)

  • 김정호;양재호;정헌영;이선형
    • 대한치과보철학회지
    • /
    • 제32권4호
    • /
    • pp.573-592
    • /
    • 1994
  • A two-stage procedure is ideal for getting a successful osseointegration. But if a one-stage procedure can achieve a similar osseointegration, the one-stage procedure has several advantages. The purpose of this study was to observe the initial bone formation and bone remodeling of open type (nonsubmerged) and closed type (submerged) titanium implants. Eight ITI hollow-screws and eight Branemark fixtures were divided into two groups (submerged and nonsubmerged) and were installed on the lower jaws of four mongrel dogs. The animals were sacrificed three months later and bone sections with implants were processed for light microscopic and fluorescent microscopic observation. The results were as follows : 1 There was no significant difference in bone-to-implant contact between submerged and nonsubmerged implants. 2. Smooth surface titanium implants showed more bone-to-implant contact than that of titanium plasma coated implants histologically. 3. Under fluorescent microscopy, the active bone remodeling and new bone formation were observed in the interface zone. 4. Under fluorescent microscopy, submerged and nonsubmerged implants had no difference in bone remodeling pattern, and intramembranous bone formation was more prominent. 5. The connective tissue fibers orienting perpendicularly toward implant surface were oberved in the neck of implants.

  • PDF

선형 추진 BLDC 모터에 대한 파라미터 추정기법을 이용하는 오토튜닝(Auto Tunning) PI 제어기설계 (The Design of an Auto Tunning PI Controller using Parameter Estimation Method for the Linear BLDC Motor)

  • 차영범;송도호;김진애;최중경
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2005년도 춘계종합학술대회
    • /
    • pp.959-962
    • /
    • 2005
  • 서보 모터는 컴퓨터와 센서로부터 오는 지령에 대해 높은 위치 정밀도와 정확한 속도제어가 가능해 자동화 시스템에서 중요한 부분으로 사용된다. 본 논문에서는 선형추진 BLDC모터로부터 얻어지는 파라메터를 추정하여 정현여자에 의해 구동되는 방식을 제안했다. 파라미터 추정은 제어기의 게인 튜닝과 외란 관측기를 통해 이루어졌다. 이러한 것을 가능하게 하기 위해 DSP(TMS320F240)를 사용하여 시스템을 구성 하였으며 FOC(Field Oriented Control)방식을 적용하였다. 본 시스템에 사용 된 TMS320F240은 A/D Converter와 PWM 발생부, 다수의 IO Port를 내장하고 있어 서보모터 제어에 유용하게 사용될 수 있는 프로세서이다.

  • PDF

Clavicle Nonunion: Matchstick Bone-grafting and Osteosynthesis

  • Park, Yong Bok;Yoo, Jae Chul;Park, Geun Min;Kum, Dong Ho;Tauheed, Mohammed;Jeong, Jeung Yeol
    • Clinics in Shoulder and Elbow
    • /
    • 제19권1호
    • /
    • pp.33-38
    • /
    • 2016
  • Background: This study was conducted to evaluate the surgical outcomes of plate fixation using autologous iliac bone graft shaped in the form of a matchstick in clavicle nonunion resulting from prior surgical or non-surgical management. Methods: From May 2005 to February 2013, 17 patients underwent surgery for clavicle nonunion. The mean age at the time of surgery was 48.8 years. The iliac bone was harvested and shaped into slivers approximately 3 cm long, which resembled matchsticks. After opening of the medullary canal, the plate and screws were applied and cancellous bone was placed at the nonunion site. Matchstick bone grafts which were longitudinally placed and encircled on the nonunion site were tied with periosteum using 3-4 stitches. Union was determined via postoperative plane X-ray. Clinical status was evaluated using the visual analogue scale score for pain, and Constant and American Shoulder Elbow Surgeon score. Results: All patients had a stable radiological union at the follow-up. The mean duration from index operation to nonunion operation was 13.2 months (7-32 months). The mean follow-up period was 20.1 months (8-56 months), and the mean duration until union was 11.2 weeks (8-16 weeks). All clinical scores were improved at the final follow-up (p<0.001). The mean segmental defect was $3.3{\pm}2.6mm$ (1-18 mm); and the difference in clavicular length between operative and non-operative site was $5.9{\pm}6.9mm$. Conclusions: Matchstick shaped autologous iliac bone grafting technique in clavicle nonunion is acceptable with a high union rate.

Comparison between Accurate Anatomical Reduction and Unsuccessful Reduction with a Remaining Gap after Open Reduction and Plate Fixation of Midshaft Clavicle Fracture

  • Kim, Joon Yub;Choe, Jung Soo;Chung, Seok Won
    • Clinics in Shoulder and Elbow
    • /
    • 제19권1호
    • /
    • pp.2-7
    • /
    • 2016
  • Background: The purpose of this study is to compare the radiological and clinical outcomes after open reduction and plate fixation of midshaft clavicle fractures between patients who achieved successful anatomical reduction and those who had a remaining fracture gap even after open reduction and plate fixation, and were thus treated with additional demineralized bone matrix (DBM). Methods: This retrospective analysis was conducted on 56 consecutive patients who underwent open reduction and internal fixation using a locking compression plate for acute displaced midshaft clavicle fractures, and who underwent radiographic and clinical outcome evaluations at least 6 months postoperatively. The outcomes between those who achieved perfect anatomical reduction without remnant gap (n=32) and those who had a remaining fracture gap even after open reduction and plate fixation treated with additional DBM (n=24) were evaluated. Results: There were no differences in the use of lag screws or wiring and operation time (all p>0.05) between those with and without remnant gap. No difference in the average radiological union time and clinical outcomes (satisfaction and Constant score) was observed between the two groups (all p>0.05). However, significantly faster union time was observed for AO type A fracture compared with other types (p=0.012), and traffic accident showed association with worse clinical outcomes compared with other causes of injury. Conclusions: Surgical outcome of midshaft clavicle fracture was more affected by initial fracture type and event, and re-reduction and re-fixation of the fracture to obtain a perfect anatomical reduction spending time appears to be unnecessary if rigid fixation is achieved.

3상 170 kV 가스절연개폐장치(GIS)의 사고 원인 분석 및 예방 대책 (Analysis of the Causes of Accidents Related to 3 Phase 170 kV Gas Insulated Switchgears(GIS) and Preventive Measures)

  • 최충석
    • 한국안전학회지
    • /
    • 제26권4호
    • /
    • pp.41-46
    • /
    • 2011
  • The purpose of this paper is to analyze the causes of accidents related to the 3 phase 170 kV gas insulated switchgear of a power system collected from accident sites to secure data for the prevention of similar accidents and provide important points of view regarding diagnosis for the prevention of accidents involving gas insulated switchgears. The analysis results of the causes of accidents involving gas insulated switchgears showed deformation of the manipulation lever installed at the S-phase, disconnection of the insulation rod connection, melting of the upper conductor, a damaged tulip, damage to the lower spacer and the spacer at the breaker, etc. It is believed from this result that the potential for accidents has expanded due to accumulated energy as a result of repeated deterioration. The carbonization depth of a GIS was formed near the screw (T2, T3) used to secure the lower pole of the S-phase tulip. It is not known what has caused the screws to be extruded and melted. However, it is thought that an unbalanced electromagnetic force, micro-discharge, surface discharge, etc., have occurred at that point. In addition, even though 16 years have passed since its installation, there was no installation defect, act of arson, accidental fire, etc. General periodical inspection and diagnosis failed to find the factors causing the accidents. As a system contained in a closed metal container, it has a high risk factor. Therefore, it is necessary to design, install and operate a GIS in accordance with the standard operational procedure (SOP). In addition, it is necessary to apply conversion technology for periodical SF6 gas analysis and precision safety diagnosis. It is expected that tracking and managing these changes in characteristics by recording the results on the history card will provide a significant accident prevention effect.

The Role of Minimally Invasive Plate Osteosynthesis in Rib Fixation: A Review

  • Bemelman, Michael;van Baal, Mark;Yuan, Jian Zhang;Leenen, Luke
    • Journal of Chest Surgery
    • /
    • 제49권1호
    • /
    • pp.1-8
    • /
    • 2016
  • More than a century ago, the first scientific report was published about fracture fixation with plates. During the 1950's, open reduction and plate fixation for fractures were standardized by the founders of Arbeitsgemeinschaft $f{\ddot{u}}r$ osteosynthesefragen/Association for the Study of Internal Fixation. Since the introduction of plate fixation for fractures, several plates and screws have been developed, all with their own characteristics. To accomplice more fracture stability, it was thought the bigger the plate, the better. The counter side was a compromised blood supply of the bone, often resulting in bone necrosis and ultimately delayed or non-union. With the search and development of new materials and techniques for fracture fixation, less invasive procedures have become increasingly popular. This resulted in the minimally invasive plate osteosynthesis (MIPO) technique for fracture fixation. With the MIPO technique, procedures could be performed with smaller incisions and thus with less soft tissue damage and a better preserved blood supply. The last 5 years rib fixation has become increasingly popular, rising evidence has becomeavailable suggesting that surgical rib fixation improves outcome of patients with a flail chest or isolated rib fractures. Many surgical approaches for rib fixation have been described in the old literature, however, most of these techniques are obscure nowadays. Currently mostly large incisions with considerable surgical insult are used to stabilize rib fractures. We think that MIPO deserves a place in the surgical treatment of rib fractures. We present the aspects of diagnosis, preoperative planning and operative techniques in regard to MIPO rib fixation.

나사조임토크에 따른 전선접속부의 열적특성에 관한 연구 (A Study on the Thermal Characteristics of Wire Connection Part Depending on the Screw Torque)

  • 김시국;지승욱;박상민;이춘하
    • 한국화재소방학회논문지
    • /
    • 제26권4호
    • /
    • pp.82-88
    • /
    • 2012
  • 본 논문은 나사조임 단자대에 접속되는 전선접속부의 나사조임토크에 따른 열적특성을 분석하고자, 나사조임토크를 KS C 2625에서 규정한 정상조임토크와 시공불량 및 경년변화 등의 원인으로 인해 나사조임의 풀림으로 발생될 수 있는 이상조임토크를 실험의 변수로 하였다. 이때, 정상조임토크와 이상조임토크에 동일한 부하를 인가한 후, 열화상카메라를 이용하여 전선접속부의 열적특성을 측정한 후 비교 분석하였다. 도출된 결과를 바탕으로 향후 전기안전점검 시 단자대 접속개소의 조임토크 불량으로 인한 발열을 사전에 감지하고, 전기화재의 위험성이 나타날 가능성을 최소화 할 수 있는 대책자료로 활용하고자 한다.

전두동 골절 환자에서 머리덮개뼈의 바깥판을 한판으로 이용한 즉시 전두동 재건술 1례 (A Case Report of an Immediate Frontal Sinus Reconstruction Using an Outer Table Calvarial Bone Graft in an En Bloc Manner)

  • 김종도;김정태;김연환
    • 대한두개안면성형외과학회지
    • /
    • 제12권1호
    • /
    • pp.33-36
    • /
    • 2011
  • Background: In a frontal sinus reconstruction, the literature primarily recommends a surgical approach for definite treatment with the exception of for anterior wall fractures with no dislocation. Many studies have assessed a range of methods for the reduction of frontal sinus fractures. This paper presents a case, in whom the anterior wall of the frontal sinus was reconstructed using an outer table calvarial bone graft in an en bloc manner. Patient and methods: A 36-year-old male visited the emergency room with a heavy injury to the forehead. He was diagnosed with fractures of the anterior and posterior wall of the frontal sinus. The neurosurgeon removed the fractured area and repaired the meninges. Afterwards, cranialization was performed and the opening of the nasofrontal duct was obstructed. After fixing the removed bone to its original location, all fragments of fractured anterior wall were purged out and the anterior wall reconstructed using an en bloc calvarial bone graft. Results: In the post-operative 8 months period, there were no complications, the round contour of the forehead was expressed well and the patient was satisfied with the result. Conclusion: There are many methods for reconstructing the anterior wall of the frontal sinus. On the other hand, in cases of large fracture sites with many fractured bone fragments, en bloc harvesting of the outer table calvarial bone could be a better choice than making use of only plates and screws because this method shows a good results in terms of aesthetics with a low complication rate.

Skull Reconstruction with Custom Made Three-Dimensional Titanium Implant

  • Cho, Hyung Rok;Roh, Tae Suk;Shim, Kyu Won;Kim, Yong Oock;Lew, Dae Hyun;Yun, In Sik
    • 대한두개안면성형외과학회지
    • /
    • 제16권1호
    • /
    • pp.11-16
    • /
    • 2015
  • Background: Source material used to fill calvarial defects includes autologous bones and synthetic alternatives. While autologous bone is preferable to synthetic material, autologous reconstruction is not always feasible due to defect size, unacceptable donor-site morbidity, and other issues. Today, advanced three-dimensional (3D) printing techniques allow for fabrication of titanium implants customized to the exact need of individual patients with calvarial defects. In this report, we present three cases of calvarial reconstructions using 3D-printed porous titanium implants. Methods: From 2013 through 2014, three calvarial defects were repaired using custom-made 3D porous titanium implants. The defects were due either to traumatic subdural hematoma or to meningioma and were located in parieto-occipital, fronto-temporo-parietal, and parieto-temporal areas. The implants were prepared using individual 3D computed tomography (CT) data, Mimics software, and an electron beam melting machine. For each patient, several designs of the implant were evaluated against 3D-printed skull models. All three cases had a custom-made 3D porous titanium implant laid on the defect and rigid fixation was done with 8 mm screws. Results: The custom-made 3D implants fit each patient's skull defect precisely without any dead space. The operative site healed without any specific complications. Postoperative CTs revealed the implants to be in correct position. Conclusion: An autologous graft is not a feasible option in the reconstruction of large calvarial defects. Ideally, synthetic materials for calvarial reconstruction should be easily applicable, durable, and strong. In these aspects, a 3D titanium implant can be an optimal source material in calvarial reconstruction.