Objective : To report our experience with pyogenic spondylitis treated with anterior radical debridement and insertion of a titanium mesh cage and to demonstrate the effectiveness and safety of the use of a titanium mesh cage in the surgical management of pyogenic spondylitis. Methods : We retrospectively analyzed the clinical characteristics of 19 patients who underwent surgical treatment in our department between January 2004 and December 2008. The average follow-up period was 11.16 months (range, 6-64 months). We evaluated risk factors, cultured organisms, lab data, clinical outcomes, and radiographic results. Surgical techniques for patients with pyogenic spondylitis were anterior radical debridement and reconstruction with titanium mesh cage insertion and screw fixation. All patients received intravenous antibiotics for at least 6 weeks postoperatively, and some patients received oral antibiotics. Results : The infections resolved in all of the patients as noted by normalization of their erythrocyte sedimentation rates and C-reactive protein levels. The mean pain score on a Visual Analog Scale was 7.8 (range, 4-10) before surgery and 2.4 (range, 1-5) after surgery. The Frankel grade was improved by one grade in seven patients. After surgery, the average difference of the angle was improved about $6.96^{\circ}$ in all patients. At the last follow-up, the mean loss of correction was $4.86^{\circ}$. Conclusion : Anterior radical debridement followed by the placement of instrumentation with a titanium mesh cage may be a safe and effective treatment for selected patients with pyogenic spondylitis. This surgical therapy does not lead to recurrent pyogenic spondylitis.
Bony fixation of implants during the early phase of healing is important in order to get secondary stability of the implant assuring the success of the treatment. Because the successful placement of the implant is limited by the quality and quantity of bone, other agents which stimulate bone formation in the peri-implant spaces has been illustrated. Platelet-derived growth factor (PDGF) has been shown to regulate DNA and protein synthesis in bone cells in vitro and to interact synergistically to enhance soft tissue wound healing in vivo. The purpose of this study was to evaluate bone promotion around implants which were augmented with sagittal split osteotomy or autogenous veneer bone graft using the platelet derived growth factor(PDGF). After placement of newly designed twenty four screw-type implants, which were 12mm in length and 4mm in diameter in 6 dogs. $4{\mu}g$ of PDGF B/B was applied with surgicel carriers. The dogs were sacrificed at 3 days, 1, 2, 3, 6, and 12 weeks after implantation. Specimens were examined clinically, radiographically, histologically, and histomorphometrically. The results were as follows: 1. Clinically and radiologically, there was no significant difference in bone formation and healing pattern between experimental and control group. 2. In autogenous veneer bone graft group, bone formation was observed at 1st week in the experimental groups but 2nd week in the control groups. At 3rd week, the expeimental groups showed more bone formation comparing to the control groups. 3. In sagittal split osteotomy group, bone formation was observed at 1st week in both groups. But the experimental groups showed more bone formation comparing to the control groups after 2nd week. 4. The bone growth rate of experimental group was more rapid than that of control group. These results indicated that PDGF did not affect the initiation of new bone formation, but it accelerated the bone formation at the early period.
Objective : Vertebral body replacement following corpectomy in thoracic or lumbar spine is performed with titanium mesh cage (TMC) containing any grafts. Radiological changes often occur on follow-up. This study investigated the relationship between the radiological stability and clinical symptoms. Methods : The subjects of this study were 28 patients who underwent corpectomy on the thoracic or lumbar spine. Their medical records and radiological data were retrospectively analyzed. There were 23 cases of tumor, 2 cases of trauma, and 3 cases of infection. During operation, spinal reconstruction was done with TMC and additional screw fixation. We measured TMC settlement in sagittal plane and spinal angular change in coronal and sagittal plane at postoperative one month and last follow-up. Pain score was also checked. We investigated the correlation between radiologic change and pain status. Whether factors, such as the kind of graft material, surgical approach, and fusion can affect the radiological stability or not was analyzed as well. Results : Mean follow-up was 23.6 months. During follow-up, $2.08{\pm}1.65^{\circ}$ and $6.96{\pm}2.08^{\circ}$ of angular change was observed in coronal and sagittal plane, respectively. A mean of cage settlement was $4.02{\pm}2.83mm$. Pain aggravation was observed in 4 cases. However, no significant relationship was found between spinal angular change and pain status (p=0.518, 0.458). Cage settlement was seen not to be related with pain status, either (p=0.644). No factors were found to affect the radiological stability. Conclusion : TMC settlement and spinal angular change were often observed in reconstructed spine. However, these changes did not always cause postoperative axial pain.
The fracture and fracture-dislocation of the neck of the talus (Hawkins' type I-IV) are uncommon injuries and represent only 0.12 to 0.32% of all fracures. Authors clinically evaluated in 12 cases Whom treated fracures of the neck of the talus, at department of orthopaedic surgery, Sun General Hospital, from 1990 to 1996, and the following results are obtained. 1. Of 12 cases, there were 11 males and 1 female, average age was 30 years. 2. Causes of fracture was fall down injury in 7 cases(58%), traffic accident in 4 cases(33%), direct trauma in 1 case(8%). 3. According to the classification by Hawkins' type I in 2 cases(17%), type II in 7cases (58%), type III in 3cases(25%). 4. Associated injuries were calcaneal fracture in 3 cases, fracture-dislocation of talus in 3 cases, subtalar dislocation in 3 cases, medial malleolar fracture in 5 cases, soft tissue injury in 3 cases, femur and tibia fracture in 1 case, and lumbar Spine compression fracture in 1 case. 5. Average time to operation after injury was 2.5 days. 6. In 2 cases were treated conservatively and 10 cases were treated open reduction and internal fixation with screw or K-wire. 7. Complications were avascular necrosis in 4 cases, post traumatic arthritis in 2 cases, skin necrosis in 4 cases, and then ankle fusion was done in 2 cases. 8. High rate of complication was seen in the talar neck fracture associated with calcaneal fracture. In the analysis of above results, evaluated by Hawkins' scoring system were excellent to fair in 75%.
Jung, Gyu Sik;Kim, Taek Kyun;Lee, Jeong Woo;Yang, Jung Dug;Chung, Ho Yun;Cho, Byung Chae;Choi, Kang Young
Archives of Plastic Surgery
/
제44권1호
/
pp.19-25
/
2017
Background Numerous condylar repositioning methods have been reported. However, most of them are 2-dimensional or are complex procedures that require a longer operation time and a highly trained surgeon. This study aims to introduce a new technique using a condylar repositioning plate and a centric relation splint to achieve a centric relationship. Methods We evaluated 387 patients who had undergone surgery for skeletal jaw deformities. During the operation, a centric relation splint, intermediate splint, final centric occlusion splint, and condylar repositioning plate along with an L-type mini-plate for LeFort I osteotomy or a bicortical screw for bilateral sagittal split ramus osteotomy were utilized for rigid fixation. The evaluation included: a physical examination to detect preoperative and postoperative temporomandibular joint dysfunction, 3-dimensional computed tomography and oblique transcranial temporomandibular joint radiography to measure 3-dimensional condylar head movement, and posteroanterior and lateral cephalometric radiography to measure the preoperative and postoperative movement of the bony segment and relapse rate. Results A 0.3% relapse rate was observed in the coronal plane, and a 2.8% relapse rate in the sagittal plane, which is indistinguishable from the dental relapse rate in orthodontic treatment. The condylar repositioning plate could not fully prevent movement of the condylar head, but the relapse rate was minimal, implying that the movement of the condylar head was within tolerable limits. Conclusions Our condylar repositioning method using a centric relation splint and miniplate in orthognathic surgery was found to be simple and effective for patients suffering from skeletal jaw deformities.
Journal of the Korean Association of Oral and Maxillofacial Surgeons
/
제40권6호
/
pp.285-290
/
2014
Objectives: We compared resorbable plates with titanium plates for treatment of combined mandibular angle and symphyseal fractures. Materials and Methods: Patients with mandibular angle and symphysis fractures were divided into two groups. The control (T) group received titanium plates while the experimental (R) group received resorbable plates. All procedures were carried out under general anesthesia using standard surgical techniques. We compared the frequency of wound dehiscence, development of infection, malocclusion, malunion, screw breakage, and any other technical difficulties between the two groups. Results: Thirteen patients were included in the R group, where 39 resorbable plates were applied. The T group consisted of 16 patients who received 48 titanium plates. The mean age in the R and T groups was 28.29 and 24.23 years, respectively. Primary healing of the fractured mandible was obtained in all patients in both groups. Postoperative complications were minor and transient. Moreover, there were no significant differences in the rates of various complications between the two groups. Breakage of 3 screws during the perioperative period was seen in the R group, while no screws or plates were broken in the T group. Conclusion: Resorbable plates can be used to stabilize combined mandibular angle and symphysis fractures.
Purpose: In accordance to an increased interest in facial appearance and the popularization of computed tomography scanning, the number of diagnosis and treatment of blowout fractures has been increased. The purpose of this article is to review pure blowout fracture surgery through transconjunctival incision focusing on complications and their management. Methods: In this retrospective study, 583 patients, who had been treated for pure blowout fracture through transconjunctival incision from 2000 to 2009, were evaluated. Their hospital records were reviewed according to their sex, age, fracture site, preoperative presentations, time interval between trauma and surgery, and postoperative complications. Results: According to postoperative follow-up results, there were early complications that included wound dehiscence and infection (0.2%), hematoma (insomuch as extraocular movement is limited) (0.7%), lacriminal duct injury (0.5%), and periorbital nerve injury (0.7%). In addition, there were late complications that lasted more than 6 months, that included persistent diplopia (1.7%), extraocular movement limitation (0.9%), enophthalmos (1.0%), periorbital sensation abnormalities (1.0%), and entropion (0.5%). Conclusion: We propose the following guidelines for prevention of postoperative complications: layer by layer closure; bleeding control with the epinephrine gauzes, Tachocomb, and Tisseel; conjunctival incision 2 to 3 mm away from punctum; avoidance of excessive traction; performing surgical decompression and high dose corticosteroid therapy upon confirmation of nerve injury; atraumatic dissection and insertion of Medpor Barrier implant after securing a clear view of posterior ledge; using Medpor block stacking technique and BioSorb FX screw fixation; performing a complete resection of the anterior ethmoidal nerve during medial wall dissection; and making an incision 2 to 3 mm below the tarsal plate.
Purpose: The purpose of this study was to evaluate the frequency of troughing and stress fracture, which are the major complications of scarf osteotomy, and to suggest methods to prevent these complications. Materials and Methods: We reviewed 243 cases of 137 patients treated with the scarf osteotomy for hallux valgus from January 2005 to December 2012. The mean follow-up period was 2.8 years. During the scarf osteotomy, a long oblique longitudinal osteotomy was performed in order to decrease the possibility of troughing and stress fracture. Radiographs of lateral view of the foot were obtained and the thicknesses of the first metatarsal base at the sagittal plane were measured and compared. Results: There was no troughing during fragment translation and screw fixation intraoperatively. Radiographs of lateral view of the foot taken preoperatively and at the last follow-up showed that the mean thickness of the first metatarsal was 22.4 mm preoperatively and 21.6 mm at the last follow-up, with a mean difference of 0.8 mm. And no stress fracture was observed. Conclusion: To prevent troughing and stress fracture, a long oblique longitudinal cut, parallel to the first metatarsal plantar surface, was performed, making both ends of the proximal segment truncated cone-shape, and securing the strong bony strut of the proximal segment. No troughing or stress fracture was experienced with scarf osteotomy.
Kim, Hyungkyoo;Jeong, Heejun;Park, Chul;So, Kyung-Min;Park, Jiyoung;Jeong, Seong Mok;Lee, Haebeom
한국임상수의학회지
/
제33권5호
/
pp.300-303
/
2016
An age-unknown, 4.8 kg, male, wild, domestic short-hair cat was presented for left hindlimb lameness. A physical examination revealed a draining tract which was suspected of bite on left calcaneal bone. The left tarsal joint was markedly swollen and exudates were observed around the draining tract. Sequestrum at left calcaneus bone, and osteolysis were identified by radiography. The sequestrum and its surrounding exudative tissue were debrided during surgery and the tissue was submitted for bacterial culture and sensitivity test. The debridement caused a bone defect ($1.5cm{\times}0.5cm{\times}0.5cm$) on the medial left calcaneal bone. Plate and screw fixation was performed to the calcaneus bone as buttress plate. Recombinant human bone morphogenetic protein-2 (rhBMP-2) loaded hydroxyapatite was implanted in the bone defect. Furthermore, Amikacin-impregnated collagen sponges were also placed around bone plate to deliver local antibiotics. A systemic antibiotic treatment regimen based on bacterial culture and sensitivity test results was administered for 4 weeks. The wound properly healed without any signs of infection, and the bone healing was confirmed by radiography. The patient showed normal weight bearing ambulation at 18 weeks after surgery. The use of rhBMP-2 and local antibiotic delivery system is a good surgical option for the one-stage treatment of chronic osteomyelitis.
본 연구에서는 환자의 골다공증 유무에 따른 내고정 장치 시술 직후 및 융합 후의 안정성을 평가하기 위해 다양한 하중 모드에서 C5-C6 운동분절의 생체역학적 거동을 분석하였다. 이러한 목적으로 먼저, C5-C6 경추부의 유한요소 모델을 구현하여 검증하였다. 모델의 결과는 기존 실험치와 유사하여 신뢰성이 부여되었다. 검증된 모델은 Smith-Robinson 방식으로 골이식물을 삽입한 후 전방 내고정 장치를 적용한 시술 상황을 재현하기 위해 수정되었다. 수정된 모델은 두 종류로 구현되었다. (1) 첫 번째 모델에서는, 시술 직후의 상황을 재현하기 위해 골이식물과 종판의 경계면에 접촉요소를 사용하였다. (2)두 번째 모델에서는 완전히 융합된 상황을 나타내기 위해 골이식물을 종판에 고정하였다. 골다공증의 효과를 예측하기 위하여 두 모델의 해면골에 대한 탄성계수를 변화시켰다(정상: 100MPa, 골다공증: 40MPa). 각 모델의 C5 주체의 상위면에 73.6N의 압축 하중을 가한 후에 108Nm의 굴곡/신전, 굽힘, 비틀림 하중을 가하였으며, C6 추체의 하단면은 모든 방향에 대하여 구속하였다. 전체적인 결과에 있어서 상대적 회전운동, 미끄럼운동, 골이식물 내에서의 von Mises 응력의 경우 정상 모델에 비해 골다공증 모델에서 증가함을 보였으며, 특히 시술 직후의 모델에서 비틀림 하중이 가해진 경우, 상대적 회전운동 및 미끄럼 운동이 가장 높게 예측되었다. 이는 골다공증환자에게 전방 내고정 장치를 시술한 경우 골이식물의 파단 및 유합의 실패가 비틀림 하중에서 발생할 수 있음을 나타낸다. 해면골의 von Mises 응력은 시술 직후에 골다공증 모델의 모든 하중 모드에서, 유합 후에는 굽힘 하중 외의 모든 하중에서 ultimate strength를 초과하는 것으로 나타나 골다공증 환자에게 screw의 해리가 발생할 가능성이 높은 것으로 예측되었다. 따라서 골다공증 환자에게 과도한 운동이 발생하지 않도록 하기 위해서 시술 후 세심한 주의와 halo 같은 견고한 정형술이 필요할 것으로 사료된다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.