• 제목/요약/키워드: screw fixation

검색결과 434건 처리시간 0.026초

척추경나사의 최적설계를 위한 유한요소해석과 형성가공에 관한 연구 (A study on the finite element analysis and machining methods for optimum design of pedicle screw system)

  • 남기우;장성민;이성희;조명우
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 추계학술대회 논문집
    • /
    • pp.634-638
    • /
    • 1997
  • The objectives of this research are to develop lumber and lower-thoracic pedicle fixation system for Korean patients. To achieve the aimed goals, first, optimized shape design process is performed, and finite element methods are applied to evaluate the mechanical strength of the developed fixation system. Second, appropriate machining experiments are carried out to develop optimum machining conditions for titan~um alloys those are known as one of the most difficult-to-cut material. As the results of this research, new pedicle screw system, considering the morphological characteristics of Korean patients, is developed by applying the finite element analysis, optimum shape processing method and optimize design algorithm.

  • PDF

ATOM technique: Anatomic reduction using screw-wire Traction for Open reduction and internal fixation of Mandibular fractures

  • Ingole, Pranav D.;Rajguru, Jignesh G.;Budhraja, Nilima J.;Shenoi, Ramakrishna S.;Karmarkar, Jui S.;Dahake, Rahul N.
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제48권2호
    • /
    • pp.122-124
    • /
    • 2022
  • Various techniques are well documented to obtain anatomic reduction, such as reduction forceps, manual reduction, or a combination of these methods. However, these techniques have inherent drawbacks. We propose a new intra-operative technique for anatomic reduction using screw-wire traction for open reduction and internal fixation of mandibular fractures.

Pulmonary Embolism after Screw Fixation for a Greater Tubercle Fracture of Humerus

  • Kang, Suk;Chung, Phil Hyun;Kim, Jong Pil;Kim, Young Sung;Lee, Ho Min;Jang, Han Gil
    • Clinics in Shoulder and Elbow
    • /
    • 제17권4호
    • /
    • pp.201-204
    • /
    • 2014
  • Pulmonary embolism is a serious complication, which is well known in patients undergoing total hip or total knee arthroplasty or lower extremity fracture surgery. But, there are few literatures concerning pulmonary embolism after upper extremity surgery. Pulmonary embolism after minor upper extremity fracture surgery is extremely rare. We report a case of 66-year-old female patient that developed pulmonary embolism after percutaneous cannulated screw fixation for a greater tubercle fracture of the proximal humerus with literature review.

인간 골 간섭 나사못의 초기 고정력 (Initial Fixation Power of Human Bone Interference Screw)

  • 김정만;정양국;김양수;오인수;고인준
    • 대한정형외과스포츠의학회지
    • /
    • 제1권1호
    • /
    • pp.26-30
    • /
    • 2002
  • 목적: 동종골-슬개건-골을이용한전방십자인대재건술시인간골간섭나사못의초기및조기고정력을알아보려고하였다. 대상및방법 : 동종골-슬개건-골을이용한전방십자인대재건술을28 슬관절에대해수술후6주, 12주, 6개월, 1년에추적조사하였다. Lachman test, flexion rotation drawer test, jerk test등의이학적검사를시행하였고KT-1000 측정을동시에시행하여경골의전방전위정도를측정하였다. Lachman test는 0$\~$2mm 전방전위까지를정상으로하였고KT-1000 측정은정상측과비교하여 2mm 이내는정상으로하였다. 마지막검사시M RI를시행하였다. 결과: 단일예를제외하고는모두이학적검사와KT-1000 측정상정상범위에속하였다. 실패한일례는수술소견상이식물이경골터널에서의근위전위되었으며이는넓어진터널을감안하지않고단하나의간섭나사못을사용한기술적실수로평가되었다. 결론: 인간골골피간섭나사못은전방십자인대의재건술을시행하는데충분한초기및조기고정력을보여주었다.

  • PDF

Three-dimensional finite element analysis of the stress distribution and displacement in different fixation methods of bilateral sagittal split ramus osteotomy

  • Yun, Kyoung In;Cho, Young-Gyu;Lee, Jong-Min;Park, Yoon-Hee;Park, Myung-Kyun;Park, Je Uk
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제38권5호
    • /
    • pp.271-275
    • /
    • 2012
  • Objectives: This study evaluated a range of fixation methods to determine which is best for the postoperative stabilization of a mandibular osteotomy using three-dimensional finite element analysis of the stress distribution on the plate, screw and surrounding bone and displacement of the lower incisors. Materials and Methods: The model was generated using the synthetic skull scan data, and the surface model was changed to a solid model using software. Bilateral sagittal split ramus osteotomy was performed using the program, and 8 different types of fixation methods were evaluated. A vertical load of 10 N was applied to the occlusal surface of the first molar. Results: In the case of bicortical screws, von-Mises stress on the screws and screw hole and deflection of the lower central incisor were minimal in type 2 (inverted L pattern with 3 bicortical repositioning screws). In the case of plates, von-Mises stress was minimal in type 8 (fixation 5 mm above the inferior border of the mandible with 1 metal plate and 4 monocortical screws), and deflection of the lower central incisor was minimal in types 6 (fixation 5 mm below the superior border of the mandible with 1 metal plate and 4 monocortical screws) and 7 (fixation 12 mm below the superior border of the mandible with 1 metal plate and 4 monocortical screws). Conclusion: Types 2 and 6 fixation methods provide better stability than the others.

The influence of screw type and osseointegration ratio on stress distribution in two different endosseous implants

  • Han, Jung-Suk
    • 대한치과보철학회지
    • /
    • 제38권3호
    • /
    • pp.348-357
    • /
    • 2000
  • The purpose of this study is to examine the effect of partial osseointegration situation on bone loading patterns around two different free-standing screw shaped implants (Nobel Biocare, Gothenburg, Sweden and Degussa-Huls, Hanau, German). Two dimensional axisymmetric Finite element models of two implants(10mm length and 4mm diameter) were created according to different bone quantity, quality and osseointegration ratio in maxilla and mandible bone. At the same time uni-cortical and hi-cortical fixation were analyzed. Generally, full bond case showed less stress than partial bond case in overall area and mandibular model showed less amount of stress than that of maxilla model. Maximum stress of the Branemark implant is higher than that of ANKYLOS regardless of bonding ratio at crestal and apex region. However, more stress concentration was noted in ANKYLOS implant at screw body area especially in mandible. The effect of bicortical fixation on crestal bone stress reduction is dramatical in mandible however, there was no significant effect in maxillary case. The effect of partial bond on stress distribution was more significant at screw body and apex region than in crestal region. Partial bond cases demonstrated greater stress accumulation in trabecular bone than cortical bone. It is concluded that the more accurate model of implant and bone which affects stress and strain distribution is needed to mimic in vivo behavior of implants.

  • PDF

골다공증과 동반된 족관절 외과 골절의 지연나사를 이용한 치료 (Treatment of Ankle Lateral Malleolar Fractures Accompanying Osteoporosis using Lag Screw)

  • 이준영;이광철
    • 대한족부족관절학회지
    • /
    • 제10권2호
    • /
    • pp.207-212
    • /
    • 2006
  • Purpose: To evaluate the results of ankle lateral malleolar fractures classified as Danis-Weber type B accompanying osteoporosis that were treated with lag screw. Materials and Methods: 15 cases of Danis-Weber type B ankle lateral malleolar fractures that had T score of less than -2.5 in BMD(bone mineral density) test were selected from June 2003 to December 2005. 10 cases were males and 5 cases were females with mean age of 59 years. The main injury mechanism was supination and external rotation. Mean follow-up period was 16 months. Clinical and radiologic evaluation was done according to Meyer and Kumler's criteria. Results: All cases showed satisfying result and mean radiologic bone union period was 3 months. Anatomic reduction and bone union was acquired in all cases without complications including wound infection, skin necrosis, delayed union and nonunion Conclusions: Lag screw fixation seem to be excellent treatment of Danis-Weber type B lateral malleolar fractures with osteoporosis as it can minimize soft tissue injury and enable anatomic reduction with firm fixation.

  • PDF

Cortical lag screw fixation for the management of mandibular injuries

  • Elsayed, Shadia Abdel-Hameed
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제46권6호
    • /
    • pp.393-402
    • /
    • 2020
  • Objectives: Here, we present cases of mandibular fracture that were managed with the cortical lag screw fixation technique (CLSFT) in order to critically evaluate technique indications and limitations of application at various fracture sites. Materials and Methods: This was a retrospective cohort study. The study sample was composed of patients suffering from mandibular fractures that were treated by the CLSFT. The outcome variables were fracture type, duration of surgery, number of screws, and pattern of application. Other study categories included patient demographics and causes of injury. Chi-square tests were used to assess descriptive and inferential statistical differences, and the P-value was set at 0.05. Results: Thirty-three patients were included in the study sample, with a mean age of 30.9±11.5 years and a male predominance of 81.8%. The technique was applied more frequently in the anterior mandibular region (51.5%) than in other sites. Double CLSFT screws were required at the symphysis and parasymphysis, while single screws were used for body and angle regions. No intraoperative and postoperative variables were significantly different except for surgical duration, which was significantly different between the sites studied (P=0.035). Conclusion: We found that CLSFT is a rapid, cost-effective technique for the fixation of mandibular fractures yielding good treatment results and very limited complications. However, this technique is sensitive and requires surgical expertise to be applied to mandibular fractures that have specialized characteristics.

후방 척추고정술에서 척추경 나사못의 크기와 형태가 척추 고정력에 미치는 영향에 대한 연구 (Effects of Screw Diameter and Thread Shape on the Strength of Transpedicular Screw Fixation in Posterior Spinal Fusion)

  • 문무성;류제청;유명철;김기택
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1995년도 춘계학술대회
    • /
    • pp.23-26
    • /
    • 1995
  • The objectives of the present study are 1)to find the effect of the diameter of transpedicular screws on their fixational strength in pedicles under static pull-out loading, 2)to determine the biomechanical correlation between the pedicle diameter and the screw diameter, and 3)to find the effects of other factors in the screw design, such as materials, screw pitch, thread height and shape on their fixational strength. Biomechanical tests (Test I) were performed to evaluate the effect of the screw diameter on pull-out strength by using 60 porcine pedicls and six groups of custom-made pedicle screws with different diameters (the major and the minor diameter of the screws used in the testing varied from 4mm upto 9mm and from 3mm upto 8mm, respectively) while all other factors (materials, screw pitch, thread height and shape etc.) were fixed. In Test II, by using 61 porcine pedicles, the relationship between the ratio of the pedicle diameter and the screw diameter(=aspect ratio) of the custum-made screw and the pull-out strength of the screw was investigated. Test III was performed with 94 porcine pedicles and 8 different types of the commercial screws from 6 major productors in order to determine the effect of the screw diameter, pitch and the thread shape on the pull-out strength of the screw, respectively. The results of Test I showed that the axial pull-out resistance of the screw could be increased prportionaly to the screw diameter(P<0.05). But this increase in the pull-out resistance did not found when the screws of 4mm or 9mm in the diameter were employed. It was found from the results of Test II that the screws had its maximum pull-out resistant force when the aspect ratio ranging 40 - 69% (P<0.05). based on the results for the major diameter against the minor diameter of screw, the maximal pull-out resistance was found at 60-65% (P<0.05). According to these biomechanical testing results, it seems that the screw with a moderately large pitch is more desirable and the buttress-shaped screw can provide stronger fixation than the V-shape one can, if other designal factor and conditions were fixed.

  • PDF