• 제목/요약/키워드: screw fixation

검색결과 431건 처리시간 0.025초

최소 침습적 경피적 나사못 고정 방법을 이용한 전위된 관절내 종골 골절 치료 (Minimally-invasive Percutaneous Screw Fixation of Displaced Intra-articular Calcaneal Fractures)

  • 채수욱;양정환
    • 대한족부족관절학회지
    • /
    • 제14권1호
    • /
    • pp.73-78
    • /
    • 2010
  • Purpose: The purpose of this study is to analyze the clinical and radiological results of minimally invasive percutaneous screw fixation in intra-articular calcaneal fractures and its complications. Materials and Methods: This study is based on 30 intra-articular calcaneal fractures that treated by index operation from June 2005 to November 2006 with at least 6 months follow-up. We assessed the clinical and radiological outcomes and complications. Results: According to Sanders classification, there were 8 in type IIA, 7 in type IIB, 3 in type IIIAB, 6 in type IIIBC, 6 in type IV. And according to Essex-Lopresti classification, there were 9 in the tongue type, 21 in the joint depression type. Average follow-up period was 14.6 months (range: 6-23 months). Average interval between from injury to operation was 2.3 days. Average AOFAS score was 87.7 (range: 52-92). Satisfactory results were obtained in 22 cases (73.3%) by AOFAS score and in 20 cases (66.7%) by VAS score (mean: 3.4). Radiological results improved from 8.7 to 20.3 degrees in the Bohler angle and from 40.2 mm to 52.1 mm in calcaneal height. Postoperative complications were 2 skin and soft tissue problems and 1 sural neuropathy. Conclusion: Minimally invasive percutaneous screw fixation may be useful alternative surgical method in the management of Sanders type II and III calcaneal fractures, which is possible to achieves the anatomical restoration and minimizes postoperative complication in patients with high risks of soft tissue compromise and allows relatively early operation.

Pedicular and Extrapedicular Morphometric Analysis in the Korean Population : Computed Tomographic Assessment Relevance to Pedicle and Extrapedicle Screw Fixation in the Thoracic Spine

  • Kim, Jun-Hak;Choi, Gyeong-Mi;Chang, In-Bok;Ahn, Sung-Ki;Song, Joon-Ho;Choi, Hyun-Chul
    • Journal of Korean Neurosurgical Society
    • /
    • 제46권3호
    • /
    • pp.181-188
    • /
    • 2009
  • Objective : To evaluate the anatomical parameters that must be considered when performing thoracic transpedicular or extrapedicular screw fixation. Methods : We selected 958 vertebrae (1,916 pedicles) from 98 patients for analysis. Eight parameters were measured from CT scans : the transverse outer pedicular diameter, transverse inner pedicular diameter, length, angle, chord length of the pedicles and the transverse width, angle, and chord length of the pedicle-rib units. Results : The age of the patients ranged from 21 to 82 years (mean: 48.2 years) and there were 57 men and 41 women. The narrowest transverse outer pedicular diameter was at T5 (4.4 mm). The narrowest pedicle length was at T1 (15.9 mm). For pedicle angle, T1 was 31.6 degrees, which was the most convergent angle, and it showed the tendency of the lower the level, the lesser the convergent angle. The chord length showed a horizontal pattern with similar values at all levels. For the PRU width, T5 showed a similar pattern to the pedicle width at 13.4 mm. For the PRU angle, T1 was the largest angle at 46.2 degrees and the tendency was the lower the level. the narrower the angle. For chord length, T1 was the shortest at 46.9 mm and T8 was the longest at 60.1 mm. Conclusion : When transpedicular screw fixations carried out at the mid-thoracic level, special care must be taken because there is a high chance of danger of medial wall violation. In these circumstances, extrapedicular screw fixation may be considered as an alternative treatment.

Scapular spine base fracture with long outside-in superior or posterior screws with reverse shoulder arthroplasty

  • Eroglu, Osman Nuri;Husemoglu, Bugra;Basci, Onur;Ozkan, Mustafa;Havitcioglu, Hasan;Hapa, Onur
    • Clinics in Shoulder and Elbow
    • /
    • 제24권3호
    • /
    • pp.141-146
    • /
    • 2021
  • Background: The purpose of the present study was to determine how long superior screws alone or in combination with posterior placement of metaglene screws protruding and penetrating into the scapular spine in reverse total shoulder arthroplasty affect the strength of the scapular spine in a fresh cadaveric scapular model. Methods: Seven fresh cadaver scapulas were allocated to the control group (short posterior and superior screws) and seven scapulars to the study group (spine base fixation with a four long screws, three with both long superior and long posterior screws). Results: The failure load was lower in the spine fixation group (long screw, 869 N vs. short screw, 1,123 N); however, this difference did not reach statistical significance (p>0.05). All outside-in long superior or superior plus posterior screws failed due to scapular spine base fracture; failures in the short screw group were due to acromion fracture. An additional posterior outside-in screw failed to significantly decrease the failure load of the acromion spine. Conclusions: The present study highlights the significance of preventing a cortical breach or an outside-in configuration when a superior or posterior screw is inserted into the scapular spine base.

무지외반증 환자의 근위 갈매기형 절골술에서 생체 흡수성 나사못을 이용한 고정 (Bioabsorbable Screws Used in Hallux Valgus Treatment Using Proximal Chevron Osteotomy)

  • 신우진;정영우;안기용;서재웅
    • 대한족부족관절학회지
    • /
    • 제22권4호
    • /
    • pp.181-183
    • /
    • 2018
  • Hallux valgus is a deformity that causes pain in the first metatarsophalangeal joint. Surgical methods are quite diverse and a range of osteotomies are used at the proximal and distal part of the metatarsal bone and proximal phalange. Fixation methods, such as plate, screw, K-wire, and others have been used in various ways. The fixation device is often removed with various side effects due to the fixation devices. In the case of instruments that are absorbed in vivo, these procedures are not necessary to remove and there is an advantage of not performing the second operation. Three patients were treated, in which a proximal chevron osteotomy was used with a bioabsorbable screw (K-$MET^{TM}$; U&I Corporation).

설상형 관절내 종골 골절에 있어서 경피적 Acutrak 나사 고정을 이용한 수술적 치료 (Percutaneous Acutrak Screw Fixation of Intra-articular Tongue Type Fracture of Calcaneus)

  • 이성주;최신권;임문섭;황연수
    • 대한족부족관절학회지
    • /
    • 제10권1호
    • /
    • pp.71-75
    • /
    • 2006
  • Purpose: To evaluate the results of treatments by percutaneous Acutrak screw fixation for intra-articular tongue type fracture of calcaneus, especially in elderly patient or patients with underlying disease including diabetes mellitus. Materials and Methods: Seven cases with intra-articular tongue type fracture of calcaneus, from November 2003 to February 2005, were reviewed. There were 6 males and 1 female with 65 years old mean age (range: $61{\sim}71$ years old). The average follow-up period was 16 months (range: $10{\sim}25$ months). Two Steinmann pins were used for closed reduction. After closed reduction was done like Essex-Lopresti's method, two Acutrak screws were inserted. The third Acutrak screw was inserted at the sustentaculum tali away from sinus tarsi to fix the primary fracture line. The patients were evaluated with Salama scale, the extent of recovery of Bohler angle, state of subtalar joint. Results: Clinical results according Salama scale were excellent in 5 cases, and good in 2 cases. Average preoperative Bohler angle was $13^{\circ}$ (range: $12{\sim}15^{\circ}$). Average postoperative Bohler angle was 31o (range: $23^{\circ}-40^{\circ}$). There were no soft tissue complications. There were two mild subtalar arthritis. Conclusions: We think that percutaneous Acutrak screw fixation is a good option for tongue type fracture of calcaneus in elderly patient or patients with underlying disease including diabetes mellitus.

  • PDF

Short-segment Pedicle Instrumentation of Thoracolumbar Burst-compression Fractures; Short Term Follow-up Results

  • Shin, Tae-Sob;Kim, Hyun-Woo;Park, Keung-Suk;Kim, Jae-Myung;Jung, Chul-Ku
    • Journal of Korean Neurosurgical Society
    • /
    • 제42권4호
    • /
    • pp.265-270
    • /
    • 2007
  • Objective : The current literature implies that the use of short-segment pedicle screw fixation for spinal fractures is dangerous and inappropriate because of its high failure rate, but favorable results have been reported. The purpose of this study is to report the short term results of thoracolumbar burst and compression fractures treated with short-segment pedicle instrumentation. Methods : A retrospective review of all surgically managed thoracolumbar fractures during six years were performed. The 19 surgically managed patients were instrumented by the short-segment technique. Patients' charts, operation notes, preoperative and postoperative radiographs (sagittal index, sagittal plane kyphosis, anterior body compression, vertebral kyphosis, regional kyphosis), computed tomography scans, neurological findings (Frankel functional classification), and follow-up records up to 12-month follow-up were reviewed. Results : No patients showed an increase in neurological deficit. A statistically significant difference existed between the patients preoperative, postoperative and follow-up sagittal index, sagittal plane kyphosis, anterior body compression, vertebral kyphosis and regional kyphosis. One screw pullout resulted in kyphotic angulation, one screw was misplaced and one patient suffered angulation of the proximal segment on follow-up, but these findings were not related to the radiographic findings. Significant bending of screws or hardware breakage were not encountered. Conclusion : Although long term follow-up evaluation needs to verified, the short term follow-up results suggest a favorable outcome for short-segment instrumentation. When applied to patients with isolated spinal fractures who were cooperative with 3-4 months of spinal bracing, short-segment pedicle screw fixation using the posterior approach seems to provide satisfactory result.

Comparison of intermaxillary fixation techniques for mandibular fractures with focus on patient experience

  • Kim, Young Geun;Yoon, Sung Ho;Oh, Jae Wook;Kim, Dae Hwan;Lee, Keun Cheol
    • 대한두개안면성형외과학회지
    • /
    • 제23권1호
    • /
    • pp.23-28
    • /
    • 2022
  • Background: Intermaxillary fixation (IMF) is a technique that allows for the reduction and stabilization of mandibular fractures. Several methods of IMF, such as self-tapping screws or arch bars, have been developed. This study aimed to validate the usefulness of IMF with a self-tapping screw compared to IMF with arch bars with focus on the patients' perspective. Methods: We retrospectively reviewed the medical records of all patients who were treated for mandibular fractures at our hospital between August 2014 and February 2021. A total of 57 patients were enrolled in this study. Thirteen patients were excluded from the analysis: three patients were lost to follow-up, and 10 patients did not undergo IMF. Finally, 44 patients were analyzed, of which 31 belonged to the arch bar group, and 13 belonged to the screw group. Patient discomfort and pain during IMF application and removal were analyzed using a patient self-assessment questionnaire. The surgeon also assessed oral hygiene, IMF stability, and occlusion. Results: We applied IMF to 34 men (77%) and 10 women (23%). The mean age of the patients was 37.3 years. The most common fracture site was the angle (30%), followed by the parasymphysis (25%), the body (23%), the condyle (11%), and the ramus (11%). Patient discomfort and oral hygiene were statistically favorable in the screw group. The IMF application time was statistically shorter in the screw group (p< 0.001). IMF stability was not statistically different between the two groups. The pain score during IMF removal was lower in the screw group (p< 0.001). Conclusion: Compared to arch bars, IMF screws provide more comfort during the IMF period, help maintain favorable oral hygiene, and have a shorter application time. From the patient's perspective, IMF screws are an excellent alternative to conventional arch bars when applicable.

Impact of Screw Type on Kyphotic Deformity Correction after Spine Fracture Fixation: Cannulated versus Solid Pedicle Screw

  • Arbash, Mahmood Ali;Parambathkandi, Ashik Mohsin;Baco, Abdul Moeen;Alhammoud, Abduljabbar
    • Asian Spine Journal
    • /
    • 제12권6호
    • /
    • pp.1053-1059
    • /
    • 2018
  • Study Design: Retrospective review. Purpose: To detect the effect of cannulated (poly-axial head) and solid (mono-axial head) screws on the local kyphotic angle, vertebral body height, and superior and inferior angles between the screw and the rod in the surgical management of thoracolumbar fractures. Overview of Literature: Biomechanics studies showed that the ultimate load, yield strength, and cycles to failure were significantly lower with cannulated (poly-axial head) pedicle comparing to solid core (mono-axial head). Methods: The medical charts of patients with thoracolumbar fractures who underwent pedicle screw fixation with cannulated or solid pedicle screws were retrospectively reviewed; the subjects were followed up from January 2011 to December 2015. Results: Total 178 patients (average age, $36.1{\pm}12.4years$; men, 142 [84.3%]; women, 28 [15.7%]) with thoracolumbar fractures who underwent surgery and were followed up at Hamad Medical Corporation were classified, based on the screw type as those with cannulated screws and those with solid screws. The most commonly affected level was L1, followed by L2 and D12. Surgical correction of the local kyphotic angle was significantly different in the groups; however, there was no significant difference in the loss of correction of the local kyphotic angle of the groups. Surgical correction of the reduction in the vertebral body height showed statistical significance, while the average loss of correction in the reduction of the vertebral body height was not significantly different. The measurement of the angles made by the screws on the rods was not significantly different between the cannulated (poly-axial head) and solid (mono-axial head) screw groups. Conclusions: Solid screws were superior in terms of providing increased correction of the kyphotic angle and height of the fractured vertebra than the cannulated screws; however, no difference was noted between the screws in the maintenance of the superior and inferior angles of the screw with the rod.

Comparison of Posterior Fixation Alone and Supplementation with Posterolateral Fusion in Thoracolumbar Burst Fractures

  • Hwang, Jong-Uk;Hur, Jin-Woo;Lee, Jong-Won;Kwon, Ki-Young;Lee, Hyun-Koo
    • Journal of Korean Neurosurgical Society
    • /
    • 제52권4호
    • /
    • pp.346-352
    • /
    • 2012
  • Objective : We compared the radiological and clinical outcomes between patients who underwent posterior fixation alone and supplemented with fusion following the onset of thoracolumbar burst fractures. In addition, we also evaluated the necessity of posterolateral fusion for patients treated with posterior pedicle screw fixation. Methods : From January 2007 to December 2009, 46 consecutive patients with thoracolumbar burst fracture were included in this study. On the basis of posterolateral fusion, we divided our patients into the non-fusion group and the fusion group. The radiological assessment was performed according to the Cobb's method, and results were obtained at immediately, 3, 6, 12 months after surgery. The clinical outcomes were evaluated using the modified Mcnab criteria at the final follow-up. Results : The demographic data and the mean follow-up period were similar between the two groups. Patients of both groups achieved satisfactory clinical outcomes. The mean loss of kyphosis correction showed that patients of both groups experienced loss of correction with no respect to whether they underwent the posterolateral fusion. There was no significant difference in the degree of loss of correction at any time points of the follow-up between the two groups. In addition, we also compared the effect of fixed levels (i.e., short versus long segment) on loss of correction between the two groups and there was no significant difference. There were no major complications postoperatively and during follow-up period. Conclusion : We suggest that posterolateral fusion may be unnecessary for patients with thoracolumbar burst fractures who underwent posterior pedicle screw fixation.

이차적인 연부조직 손상을 동반한 종골 골절에 대한 유관 나사 및 단순 환상 강선 고정술을 이용한 치료: 2예 보고 (Treatment of Secondary Soft Tissue Compromised Calcaneus Fractures Using a Cannulated Screw and Simple Cerclage Wiring: A Report of Two Cases)

  • 김준겸;서재완
    • 대한족부족관절학회지
    • /
    • 제21권4호
    • /
    • pp.165-169
    • /
    • 2017
  • Secondary soft tissue injuries can occur from the pressure of the displaced fragment of posterior calcaneal tuberosity in calcaneal tongue-type fractures and calcaneal tuberosity avulsion fractures. The soft tissue injury can be prevented by immediate reduction of the displaced fragments. Various techniques can be used to fix the fracture fragments, but the stability of fixation and minimal invasiveness to soft tissue should be considered. This paper reports the successful outcomes of patients with soft tissue compromises in calcaneal tongue-type fractures and calcaneal tuberosity avulsion fractures. The fixation technique of a large cannulated screw and simple cerclage wiring is believed to be a useful surgical option for the treatment of secondary soft tissue compromised calcaneal fractures.