• Title/Summary/Keyword: screen tests

Search Result 187, Processing Time 0.023 seconds

Image Superimposition for the Individual Identification Using Computer Vision System (컴퓨터 시각 인식 기법을 이용한 영상 중첩법에 의한 개인식별)

  • Ha-Jin Kim
    • Journal of Oral Medicine and Pain
    • /
    • v.21 no.1
    • /
    • pp.37-54
    • /
    • 1996
  • In this thesis, a new superimposition scheme using a computer vision system was proposed with 7 pairs of skull and ante-mortem photographs, which were already identified through other tests and DNA fingerprints at the Korea National Institute of Scientific Investigation. At this computer vision system, an unidentified skull was caught by video-camcoder with the MPEG and a ante-mortem photograph was scanned by scanner. These two images were processed and superimposed using pixel processing. Recognition of the individual identification by anatomical references was performed on the two superimposed images. These results were as followings. 1. For the enhancement of skull and ante-mortem photographs, various image processing schemes, such as SMOOTH, SHARPEN, EMBOSS, MOSAIC, ENGRAVE, INVERT, NEON and COLOR TO MONO, were applied using 3*5 window processing. As an image processing result of these methods, the optimal techniques were NEON, INVERT and ENGRAVE for the edge detection of skull and ante-mortem photograph. 2. Using various superimposition image processing techniques (SRCOR, SRCAND, SRCINVERT, SRCERASE, DSTINVERT, MERGEPAINT) were compared for the enhancement of image recognition. 3. By means of the video camera, the skull image was inputed directly to a computer system : superimposing it on the ante-mortem photograph made the identification more precise and time-saving. As mentioned above, this image processing techniques for the superimposition of skull and ante-mortem photographs simply used the previous approach, In other wrods, taking skull photographs and developing it to the same size as the ante-mortem photographs. This system using various image processing techniques on computer screen, a more precise and time-saving superimposition technique could be able to be applied in the area of individual identification in forensic practice.

  • PDF

The Measurement and Analysis by Free Space Scatter Dose Distribution of Diagnostic Radiology Mobile Examination Area (영상의학과 이동검사 영역의 공간선량 분포에 대한 측정 및 분석)

  • Kim, Sung-Kyu;Son, Sang-Hyuk
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.11 no.1
    • /
    • pp.5-13
    • /
    • 2009
  • There are several reasons to take X-ray in case of inpatients. Some of them who cannot ambulate or have any risk if move are taken portable X-ray at their wards. Usually, in this case, many other people-patients unneeded X-ray test, family, hospital workers etc-are indirectly exposed to X-ray by scatter ray. For that reason I try to be aware of free space scatter dose accurately and make the point at issue of portable X-ray better in this study. kVp dose meter is used for efficiency management of portable X-ray equipment. Mobile X-ray equipment, ionization chamber, electrometer, solid water phantom are used for measuring of free space scatter dose. First of all the same surroundings condition is made as taken real portable X-ray, inquired amount of X-ray both chest AP and abdomen AP most frequently examined and measured scatter ray distribution of two tests individually changing distance. In the result of measuring horizontal distribution with condition of chest AP it is found that the mAs is decreased as law of distance reverse square but no showed mAs change according to direction. Vertical distribution showed the mAs slightly higher than horizontal distribution but it isnt found out statistical characteristic. In abdomen AP, compare with chest AP, free space scatter dose is as higher as five-hundred times and horizontal, vertical distribution are quite similar to chest AP in result. In portable X-ray test, in order to reduce the secondary exposure by free space scatter dose first, cut down unnecessary portable order the second, set up the specific area at individual ward for the test the third, when moving to a ward for the X-ray test prepare a portable shielding screen. The last, expose about 2m apart from patients if unable to do above three ways.

  • PDF

Evaluation of ROC Curve in High Kilovoltage Technique Using Simulated Nodules on Chest (고관전압 흉부촬영의 가상결절을 이용한 ROC평가)

  • Ahn, Jin-Shin;Chang, Myung-Mi;Chung, Kyung-Mo;Cheung, Hwan;Lim, Jung-Ki;Kim, Jong-Hyo
    • Journal of radiological science and technology
    • /
    • v.15 no.2
    • /
    • pp.25-30
    • /
    • 1992
  • With transmitted dose through chest which has the problem of wide variations in absorption, simple film/screen combination method makes it diffucult to image lung field, mediastinum and retrocardiac areas. In order to overcome this, it is very common to use the high kilovoltage technique in diminishing the differences between high and low contrast. We have been adopting this method at department of diagnostic radiology, Seoul National University Hospital. To compare the image of it with that of low kilovoltage technique, we did radiographic tests using beans on the skin. We marked off into three anatomical categories such as lungs, mediastinum and near diaphragm, then attached a bean on a marked area at random. In order to compare with high and low, we took a radiography of high($120{\sim}140\;kVp$) and low($70{\sim}90\;kVp$) kilovoltage tehchniques, respectively at the same time. We have done experiments 320 cases. We evaluated the results of test in response to sensitivity(true positive) and specificity(true negative). In evaluating, we gave them points from 1 to 5 according to true or false. With given points by a radiologist having much experiences, we could acquire the percentage of sensitivity and specificity. The percentage made us to get the schematic table of ROC curve of those two methods. Consequently, high kilovoltage technique appeared 18% better than low kilovoltage technique for detecting beans with our apparatus.

  • PDF

An Empirical Study on Quantitative Evaluation of Cognitive Function (인지기능의 정량적 평가를 위한 측정 모델 소프트웨어 개발 및 실험적 검증 연구)

  • Ryu, Wan-Seok;Kim, Hyung-Gun;Chung, Sung-Taek
    • Progress in Medical Physics
    • /
    • v.21 no.1
    • /
    • pp.42-51
    • /
    • 2010
  • Imaging studies using MRI, PET, and/or MEG have been primary evaluation methods to quantitatively assess cognitive function. Recent advances in computational technology and information technology may allow a novel evaluation methodology to quantitate cognitive function more cost-effectively. In this study, we developed a software package composed of a series of tests to evaluate cognitive ability combined with a user-friendly touch screen input device. This cognitive assessment tool can quantitate concentration, numeric memory, associative memory, topological memory, visual and muscular reaction, and acoustic reaction over a relatively short testing time. We performed an empirical study on eighty normal subjects aged 20 and 59 years old using the developed evaluation methods. Age-related cognitive deterioration after 40 years old was confirmed. There was no difference in cognitive ability between male and female in the same age group. This study demonstrates the feasibility of a simple but effective evaluation software tool to quantitatively assess cognitive ability. This methodology may provide improved accessibility and reduced costs to perform cognitive function studies to compare between various subject groups.

PM Reduction Characteristics of Partial Metal DPF with Screen Mesh Filter Structure (스크린 필터 구조 Partial Metal DPF의 PM 저감 특성)

  • Kim, Chunghui;Kim, Hyunchul;Lee, Geesoo;Choi, Jeonghwang;Chon, Munsoo;Shin, Suk Shin;Suh, Hyun Kyu
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.21 no.3
    • /
    • pp.82-87
    • /
    • 2013
  • In this work, the 1L grade integrated metal DOC/DPF filter that can install in engine manifold position was developed to investigate the effect of platinum-coating amount of filter on the improvement of filter activation temperature and reduction of particulate matter (PM). This filter was installed in 2.9L CI engine which meets the EURO-4 emission regulation. Tests for PM reduction efficiency of filter were conducted under ND-13 mode with full-load test condition. It was revealed that the time to reach the activation temperature of metal filter ($280^{\circ}C$) was shorter as the amount of platinum-coating increased. This short activation time can be helpful for the reduction of CO and HC emissions during cold start condition. At the same time, PM reduced as the coating amount increased. The reduction percentage of $DOC_{40}$, $DOC_{20}$, and $DOC_0$ were 96.7% (2.34 mg/kW'h), 95.1% (3.47 mg/kW'h), and 94.5% (3.69 mg/kW'h) compared to previous result (71.4 mg/kW'h), respectively.

Usefulness of four commonly used neuropathic pain screening questionnaires in patients with chronic low back pain: a cross-sectional study

  • Gudala, Kapil;Ghai, Babita;Bansal, Dipika
    • The Korean Journal of Pain
    • /
    • v.30 no.1
    • /
    • pp.51-58
    • /
    • 2017
  • Background: Recently symptoms-based screening questionnaires have gained attention for screening for a neuropathic pain component (NePC) in various chronic pain conditions. The present study assessed the usefulness of four commonly used NePC screening questionnaires including the Self-completed douleur neuropathique 4 (S-DN4), the ID Pain, the painDETECT questionnaire (PDQ), and the Self-completed Leeds Assessment of neuropathic Symptoms and Signs (S-LANSS) questionnaire in patients with chronic low back pain (CLBP) to assess the presence of NePC. Methods: This is a single-center cross-sectional study where patients with CLBP, with or without leg pain, were included. Participants were initially screened for NePC presence by a physician according to the regular practice, and later assessed using screening questionnaires. The diagnostic accuracy of these questionnaires was compared assuming the physician-made diagnosis as the gold standard. Results: A total of 215 patients with CLBP of which 164 (76.3%, 95% CI, 70.2-81.5) had a NePC were included. S-DN4, ID Pain, and PDQ have an area under the curve (AUC) > 0.8 indicating excellent discrimination. However, S-LANSS has an AUC of 0.69 (0.62-0.75), indicating low discrimination. S-DN4 has a significantly higher AUC as compared to ID Pain (d(AUC) = 0.063, P < 0.01) and S-LANSS (d(AUC) = 0.197, P < 0.01). But the AUC of S-DN4 does not significantly differ from that of PDQ (d(AUC) = 0.013, P = 0.62). Conclusions: S-DN4, ID Pain, and PDQ, but not S-LANSS, have good discriminant validity to screen for NePCs in patients with CLBP. Despite using all the tests, 20-30% of patients with an NePC were missed. Thus, these questionnaires can only be used as an initial clue in screening for NePCs, but do not replace clinical judgment.

CHEMILUMINESCENCE IN DIAGNOSIS OF ORAL LICHEN PLANUS (화학 발광 검사법을 이용한 구강 편평 태선의 진단)

  • Myoung, Hoon;Jeong, Hae-Seok;Lee, Hyun-Sun;Hong, Soon-Min;Kim, Myung-Jin
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.33 no.4
    • /
    • pp.281-287
    • /
    • 2007
  • Purpose: This study was conducted in order to evaluate how chemiluminescent lighting($ViziLite^{(R)}$) could increase the sharpness of margin and contrast to normal mucosa in the diagnosis of oral lichen planus(OLP), the most frequent oral premalignant lesion, compared with direct visual inspection under incandescent light. Methods: 41 consecutive patients, diagnosed to have OLP with visual inspection under incandescent light, were further examined with chemiluminescent light. The degrees of margin sharpness and lesion contrast were ranked on a scale from 1 to 3 for all patients under visual inspection and chemiluminescent light. The presence of additional lesion only detected by chemiluminescent light, complication, and discomfort were checked for each patient. After both screening tests, biopsy specimens were harvested from all patients with scalpels and histopathologic assessments were done. Results: All 41 patients were diagnosed to have OLP by both visual inspection and chemiluminescent light examination. This result was definitively diagnosed by histopathology. Degrees of margin sharpness and lesion contrast were increased by chemiluminescent light compared with visual inspection, but only the difference of lesion contrast was statistically significant. In 22.0% of patients, additional lesions were detected and 88.9% of them were diagnosed to have OLP histopathologically. 17.1% of patients noted discomfort and 9.8% of patients showed complications after chemiluminescent test. Conclusion: Chemiluminescent light may not be proper for the screen test of oral cancer or premalignant lesion but showed some possibility for additional diagnostic tool for definitively diagnosed patients in determination of lesion margin and scope.

Government Website Accessibility: Comparison between Korea and the United States (한국과 미국 정부기관의 웹사이트 접근성 평가)

  • Hong, Soon-Goo;Cho, Jae-Hyung;Lee, Dae-Hyung
    • Information Systems Review
    • /
    • v.7 no.1
    • /
    • pp.81-96
    • /
    • 2005
  • Because the web sites are in common today, the access to the web for disabled people and old aging people, what we call accessibility, becomes more important. Even though efforts to reduce the informational gap resulted from the lack of the accessibility have been carried out, the studies in this field in Korea are not still in popular. In this study, previous research on the measurements for the accessibility is reviewed and then a new model measuring accessibility is suggested. To increase the validity of the measurement, both an automated tool and a manual test are employed. First we used the 'A-Prompt', one of the popular automated validation tools and analyzed web sources, and applied manual tests by HPR Screen Reader. With the error rates calculated, the accessibility of the government web sites between Korea and the United States was compared and finally the conclusions were drawn.

Multivariate Analysis of the Prognosis of 37 Chondrosarcoma Patients

  • Yang, Zheng-Ming;Tao, Hui-Min;Ye, Zhao-Ming;Li, Wei-Xu;Lin, Nong;Yang, Di-Sheng
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.4
    • /
    • pp.1171-1176
    • /
    • 2012
  • Objective: The current study aimedto screen for possible factors which affect prognosis of chondrosarcoma. Methods: Thirty seven cases were selected and analyzed statistically. The patients received surgical treatment at our hospital between December 2005 and March 2008. All of them had complete follow-up data. The survival rates were calculated by univariate analysis using the Kaplan-Meier method and tested by Log-rank. ${\chi}^2$ or Fisher exact tests were carried out for the numeration data. The significant indexes after univariate analysis were then analyzed by multivariate analysis using COX regression model. Based on the literature, factors of gender, age, disease course, tumor location, Enneking grades, surgical approaches, distant metastasis and local recurrence were examined. Results: Univariate analysis showed that there were significant differences in Enneking grades, surgical approaches and distant metastasis related to the patients' 3-year survival rate after surgery (P<0.001). No significant difference was not found in gender, age, disease course, tumor location or local recurrence (P>0.05). Multivariate analysis showed that Enneking grade (P=0.007) and surgical approaches (P=0.010) were independent factors affecting the prognosis of chondrosarcoma, but distant metastasis was not (P=0.942). Conclusion: Enneking grades, surgical approaches and distant metastasis are risk factors for prognosis of chondrosarcoma, among which the former two are independent factors.

Fluorescence-in-situ-hybridization in the Surveillance of Urothelial Cancers: Can Use of Cystoscopy or Ureteroscopy be Deferred?

  • Ho, Christopher Chee Kong;Tan, Wei Phin;Pathmanathan, Rajadurai;Tan, Wei Keith;Tan, Hui Meng
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.7
    • /
    • pp.4057-4059
    • /
    • 2013
  • Background: Fluorescence in situ hybridization (FISH) testing may be useful to screen for bladder carcinoma or dysplasia by detecting aneuploidy chromosomes 3, 7, 17 and deletion of the chromosome 9p21 locus in urine specimens. This study aimed to assess the sensitivity, specificity, positive and negative predictive value of FISH in a multi-ethnic population in Asia. Materials and Methods: Patients with haematuria and/or past history of urothelial cancer on follow-up had their voided urine tested with FISH. Patients then underwent cystoscopy/ureteroscopy and any lesions seen were biopsied. The histopathological reports of the bladder or ureteroscopic mucosal biopsies were then compared with the FISH test results. Results: Two hundred sixty patients were recruited. The sensitivity and specificity of the FISH test was 89.2% and 83.4% respectively. The positive (PPV) and negative predictive values (NPV) were 47.1% and 97.9%. By excluding patients who had positive deletion of chromosome 9, the overall results of the screening test improved: sensitivity 84.6%; specificity 96.4%; PPV 75.9% and NPV 97.9%. Conclusions: UroVysion FISH has a high specificity of detecting urothelial cancer or dysplasia when deletion of chromosome 9 is excluded. Negative UroVysion FISH-tests may allow us to conserve health resources and minimize trauma by deferring cystoscopic or ureteroscopic examination.