• Title/Summary/Keyword: screen plate

Search Result 111, Processing Time 0.024 seconds

Microstructures and Optical Properties of Composite Crystals in the System (Bi2O3)0.85.(Nb2O5)0.15-6Bi2O3.SiO2 ((Bi2O3)0.85.(Nb2O5)0.15-6Bi2O3.SiO2계 복합다결정체의 미세구조와 광학적 특성)

  • 김호건
    • Journal of the Korean Ceramic Society
    • /
    • v.26 no.1
    • /
    • pp.139-145
    • /
    • 1989
  • An eutectic melt in the system(Bi2O3)0.85·(Nb2O5)0.15-6Bi2O3·SiO2 was unidirectionally solidfield at a rate of 0.5mm/h under a thermal gradient of 100℃/cm. Double crucibles and seed crystal plate were used in order to botain the composite crystals which had uniform microstructure throughout the ingot. The obtained composite crystals showed uniform microstructure, in which needle-like δ-(Bi2O3)0.85·(Nb2O5)0.15 crystals were arrayed in parallel in a matrix of γ-6Bi2O3·SiO2 single crystal. It was found that the <110> direction of δ-(Bi2O3)0.85·(Nb2O5)0.15 crystal was essentially parallel to the <111> direction of γ-6Bi2O3·SiO2 crystal in the composite crystals. A transverse thin plate of the composite crystals showed a high resolution optical transmission like an optical fiber array, and sharp chatoyancy was observed in the cabochon shaped composite crystals. Then, this may be useful for applications such as screen of a cathode ray tube or artificial cat's eye gem stones.

  • PDF

Optimum Global Failure Prediction Model of Inconel 600 Thin Plate with Two Parallel Through-Wall Cracks

  • Moon Seong In;Kim Young Jin;Lee Jin Ho;Song Myung Ho;Choi Young Hwan
    • Nuclear Engineering and Technology
    • /
    • v.36 no.4
    • /
    • pp.316-326
    • /
    • 2004
  • The $40\%$ of wall criterion, which is generally used for the plugging of steam generator tubes, is applied only to a single crack. In a previous study, a total number of 9 failure models were proposed to estimate the local failure of the ligament between cracks, and the optimum coalescence model of multiple collinear cracks was determined among these models. It is, however known that parallel axial cracks are more frequently detected than collinear axial cracks during an in-service inspection. The objective of this study is to determine the plastic collapse model that can be applied to steam generator tubes containing two parallel axial through-wall cracks. Three previously proposed local failure models were selected as the candidates. Subsequently, the interaction effects between two adjacent cracks were evaluated to screen them. Plastic collapse tests for the plate with two parallel through-wall cracks and finite element analyses were performed to determine the optimum plastic collapse model. By comparing the test results with the prediction results obtained from the candidate models, a COD base model was selected as an optimum model.

Boundary Element Analysis of Magnetic Shielding Effects of Shield Cup in Electron Gun (경계요소법을 이용한 전자총 Shield Cup의 자기차폐 특성해석)

  • Go, Chang-Seop;Jeong, Gwan-Sik;Han, Song-Yeop
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.5
    • /
    • pp.291-296
    • /
    • 2000
  • Recently large size color TV and computer monitor are very popular and a lot techniques are being developed to get a high quality picture on the screen through reducing the convergence error among the red, green and blue beams and achieving a high focusing. One of the techniques is considering the mutual effects of the components of the Brown tube. The magnetic deflection yoke, especially, stands immediately next to the electron gun and generates the leakage magnetic fields at the electron gun which affects the trajectories of the electron beams inside the gun. Hence a shield cup made of thin conducting plate is located at the end of electron gun in order to shield the leakage flux from the deflection yoke. Since the red, green and blue beams are placed unsymmetrically the shielding effects of the shield cup on the beams are not same and eddy current controller, made of thin conducting plate, is auxiliary placed inside the shield cup. In this paper a transient magnetic field analysis algorithm is developed using boundary element method, and applied to the analysis of the shielding effects of the eddy current controller of shield cup in an electron gun.

  • PDF

Evaluation of Relative Emission of Image Plate by Using Relative Sensitivity in Computed Radiography System (컴퓨터 방사선영상시스템에서 비감도를 이용한 영상판의 상대적 발광량 평가)

  • Seoung, Youl-Hun
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.11
    • /
    • pp.355-361
    • /
    • 2014
  • The aim of the present study was to evaluate a relative emission of image plate (IP) in computed radiography (CR) system by using relative sensitivity in film/screen methods. The characteristic curve was obtained by using the uniform aluminum 11-step wedge penetrometer. X-ray exposure factors on radiographic digital image were 50 kVp, 10 mAs. We adjusted zero of all parameter of algorithms (MUSICA) so proximate to raw data and applied to 200 of exposure class. Modeling on relative emission of IP are used IP without fading time and IP after 4 hours, 8 hours, 12 hours, 24 hours in the respective storage after X-ray exposure. The results of this study showed that the sensitivity point density at the measuring of relative sensitivity in CR was suited pixel values of the 2000 easy to relatively measure the characteristic curve and when relative sensitivity is decreased, the amount of light emitted from the image signal for generating was also decreased. In conclusion, the proposed method of measurement of relative sensitivity can be utilized to evaluate the quantity of relative emission of IP in CR system.

Research Trends in Light Guide Plates for LED Backlight Units (LED 백라이트유닛 도광판의 연구동향)

  • Park, So Hee;Choi, Eun Seo;Ahn, Sun Young;Shin, Yong Jin
    • Korean Journal of Optics and Photonics
    • /
    • v.28 no.6
    • /
    • pp.314-326
    • /
    • 2017
  • The display, which is closely related to modern life, is being developed as a window on a network connecting individuals, devices, and even other individuals from simple display devices, as the IT industry develops. To achieve a thinner, brighter unit with less consumption for backlighting, the LED light source has applied, and the study of complex light-guiding plates to improve luminance, uniformity, and viewing angle has been initiated. In this paper, we summarize the research results for the scatterers' pattern formation of the light-guiding plate and the arrangement and composition of the light source, which have enabled remarkable development of the LED backlight unit over the last 10 years. In addition, a large-area flat-screen illumination system, applying the light-guiding-plate technology to a currently noteworthy LED light-fixture design, is outlined. Finally, we discuss the direction and way to develop the current technology more progressively.

A Study on Performance of the Radiographic Cassettes (X선(線)필름용 카셋트의 성능(性能)에 관한 검토(檢討))

  • Choi, Jong-Hak;Jeon, Man-Jin;Huh, Joon;Kang, Se-Sik
    • Journal of radiological science and technology
    • /
    • v.5 no.1
    • /
    • pp.35-43
    • /
    • 1982
  • The authors surveyed the cassettes in 10 general hospitals and compared in experimentation on performances of 6 kinds of cassettes manufactured with several materials in order to discover the present condition and performance of the cassettes being used at present. And the authors got the following results. 1. In distribution of the cassettes in use, Okamoto's(Japan), Picker's and Titan's(U.S.A.) were more than others classified by the manufacture. The rate of using high speed was 72.0%, par speed 28.0% classified by types of intensifying screens in the cassettes and the rate of the year in use for $4{\sim}5$ years was 40.0%, $6{\sim}7$ years 24.0% classified by the years in use. 2. The results of the screen-film contact test were that tile ordinary was 42.7%, the good 36.0%, and the poor 21.3%. 3. The results of the test for light leakage were that fogged area appeared on 1 side or more in 84.0% films. 4. In Aluminum equivalents of front plate, the cassettes with a front plate consisting of carbon fiber were fewest, and the ones of bakelite and aluminum were fewer in order 5. In compared results of the exposure dosage for same density of the films, the exposure of the cassettes used carbon fiber for the material on the front plate was smallest and bakelite, auminum was smaller in order.

  • PDF

Effective Microwell Plate-Based Screening Method for Microbes Producing Cellulase and Xylanase and Its Application

  • Kim, Jennifer Jooyoun;Kwon, Young-Kyung;Kim, Ji Hyung;Heo, Soo-Jin;Lee, Youngdeuk;Lee, Su-Jin;Shim, Won-Bo;Jung, Won-Kyo;Hyun, Jung-Ho;Kwon, Kae Kyoung;Kang, Do-Hyung;Oh, Chulhong
    • Journal of Microbiology and Biotechnology
    • /
    • v.24 no.11
    • /
    • pp.1559-1565
    • /
    • 2014
  • Cellulase and xylanase are main hydrolysis enzymes for the degradation of cellulosic and hemicellulosic biomass, respectively. In this study, our aim was to develop and test the efficacy of a rapid, high-throughput method to screen hydrolytic-enzyme-producing microbes. To accomplish this, we modified the 3,5-dinitrosalicylic acid (DNS) method for microwell plate-based screening. Targeted microbial samples were initially cultured on agar plates with both cellulose and xylan as substrates. Then, isolated colonies were subcultured in broth media containing yeast extract and either cellulose or xylan. The supernatants of the culture broth were tested with our modified DNS screening method in a 96-microwell plate, with a $200{\mu}l$ total reaction volume. In addition, the stability and reliability of glucose and xylose standards, which were used to determine the enzymatic activity, were studied at $100^{\circ}C$ for different time intervals in a dry oven. It was concluded that the minimum incubation time required for stable color development of the standard solution is 20 min. With this technique, we successfully screened 21 and 31 cellulase- and xylanase-producing strains, respectively, in a single experimental trial. Among the identified strains, 19 showed both cellulose and xylan hydrolyzing activities. These microbes can be applied to bioethanol production from cellulosic and hemicellulosic biomass.

Design and Test of ASME Strainer for Coolant System of Research Reactor (연구용 원자로 냉각계통의 ASME 스트레이너 설계 및 성능시험)

  • Park, Yong-Chul;Park, Jong-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.2 no.3 s.4
    • /
    • pp.24-29
    • /
    • 1999
  • The ASME strainers have been newly installed at the suction side of each reactor coolant pump to get rid of the foreign materials which may damage the pump impeller or interfere with the coolant path of fuel flow tube or primary plate type heat exchanger. The strainer was designed in accordance with ASME SEC. III, DIV. 1, Class 3 and the structural integrity was verified by seismic analysis. The screen was designed in accordance with the effective void area from the result of flow analysis for T-type strainer. After installation of the strainer, it was confirmed through the field test that the flow characteristics of primary cooling system were not adversely affected. The pressure loss coefficient was calculated by Darcy equation using the pressure difference through each strainer and the flow rate measured during the strainer performance test. And these are useful data to predict flow variations by the pressure difference.

  • PDF

Measurement of Surface Heat Transfer Using Exponential Temperature Variations (지수형 온도변화를 이용한 표면 열전달의 측정)

  • Park, Byung Kyu;Hong, Taek;Park, Sang Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.9
    • /
    • pp.1121-1128
    • /
    • 1999
  • A single blow, transient testing method for determining the heat transfer characteristics of heat exchanger surfaces are presented. The exponential inlet temperature variations were made using screen mesh with small time constant and frontal velocities of the test section. The system is used to investigate the usefulness of a model with exponential inlet temperature variations. A data reduction program is developed to calculate the temporally and spatially averaged heat transfer coefficient using the measured disturbance and response of the fluid temperature. The results are compared with the existing theoretical and experimental data for parallel plate stacks. It was recommended to take an average for the time greater than the 99% of the final temperature had reached in order to obtain fairly good results.

A Study on the Condenser Temperature Characteristics of a Disk Type Heat Pipe (원판형 히트파이프의 응축부 온도 특성에 관한 실험적 연구)

  • Boo, Joon-Hong;Chung, Won-Bok;Kim, Tae-Gyu
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.148-153
    • /
    • 2000
  • An experimental study was conducted to investigate an isothermal characteristics of the condenser surface of disk type heat pipe using PF 5060 and FC 40 as working fluids. Desired temperature range at the condenser surface was $90^{\circ}C{\sim}130^{\circ}C$, which was cooled by natural convection. The operating temperature, the height of vapor space, the wall thickness of condenser, and the existence of a wick structure were considered as experimental factors. The temperature difference and the temperature fluctuation at the condenser surface were analysed to describe the performance of the heat pipe.

  • PDF