• 제목/요약/키워드: school zones

검색결과 483건 처리시간 0.024초

Mechanical behavior of sandstones under water-rock interactions

  • Zhou, Kunyou;Dou, Linming;Gong, Siyuan;Chai, Yanjiang;Li, Jiazhuo;Ma, Xiaotao;Song, Shikang
    • Geomechanics and Engineering
    • /
    • 제29권6호
    • /
    • pp.627-643
    • /
    • 2022
  • Water-rock interactions have a significant influence on the mechanical behavior of rocks. In this study, uniaxial compression and tension tests on different water-treated sandstone samples were conducted. Acoustic emission (AE) monitoring and micro-pore structure detection were carried out. Water-rock interactions and their effects on rock mechanical behavior were discussed. The results indicate that water content significantly weakens rock mechanical strength. The sensitivity of the mechanical parameters to water treatment, from high to low, are Poisson ratio (𝜇), uniaxial tensile strength (UTS), uniaxial compressive strength (UCS), elastic modulus (E), and peak strain (𝜀). After water treatment, AE activities and the shear crack percentage are reduced, the angles between macro fractures and loading direction are minimized, the dynamic phenomenon during loading is weakened, and the failure mode changes from a mixed tensile-shear type to a tensile one. Due to the softening, lubrication, and water wedge effects in water-rock interactions, water content increases pore size, promotes crack development, and weakens micro-pore structures. Further damage of rocks in fractured and caved zones due to the water-rock interactions leads to an extra load on the adjoining coal and rock masses, which will increase the risk of dynamic disasters.

A Wide-field-of-view Table-ornament Display Using Electronic Holography

  • Daerak Heo;Hosung Jeon;Sungjin Lim;Joonku Hahn
    • Current Optics and Photonics
    • /
    • 제7권2호
    • /
    • pp.183-190
    • /
    • 2023
  • Three-dimensional (3D) displays provide a significant advantage over traditional 2D displays by offering realistic images, and table-style displays in particular are ideal for generating 3D images that appear to float above a table. These systems are based on multiview displays, and are typically operated using temporal or spatial multiplexing methods to expand the viewing zone (VZ). The VZ is an expanded space that results from merging the sub-viewing zones (SVZs) from which an individual view is made. To increase the viewing angle, many SVZs are usually required. In this paper, we propose a table-ornament electronic holographic display that utilizes 3f parabolic mirrors. In holography, the VZ is not simply expanded but synthesized from SVZs to implement continuous motion parallax. Our proposed system is small enough to be applied as a table ornament, in contrast to traditional tabletop displays that are large and not easily portable. By combining multiview and holographic technologies, our system achieves continuous motion parallax. Specifically, our system projects 340 views using a time-multiplexing method over a range of 240 degrees.

Analysis of risk for high-speed trains caused by crosswind in subgrade settlement zones based on CFD-FE coupling

  • Qian Zhang;Xiaopei Cai;Tao Wang;Yanrong Zhang;Shusheng Yang
    • Wind and Structures
    • /
    • 제37권4호
    • /
    • pp.275-287
    • /
    • 2023
  • Subgrade differential settlement of high-speed railways was a pivotal issue that could increase the risk of trains operation. The risk will be further increased when trains in the subsidence zone are affected by crosswinds. In this paper, the computational fluid dynamics (CFD) model and finite element (FE) model were established, and the data transmission interface of the two models was established by fluid-solid interaction (FSI) method to form a systematic crosswind-train-track-subgrade dynamic model. The risk of high-speed train encountering crosswind in settlement area was analyzed. The results showed that the aerodynamic force of the trains increased significantly with the increase in crosswind speed. The aerodynamic force of the trains could reach 125.14 kN, significantly increasing the risk of derailment and overturning. Considering the influence of crosswind, the risk of train operation could be greatly increased. The safety indices and the wheel-rail force both increased with the increase of the wind speed. For the high-speed train running at 350 km/h, the warning value of wind speed was 10.2 m /s under the condition of subgrade settlement with wavelength of 20 m and amplitude of 15 mm.

Adaptive energy group division in the few-group cross-section generation for full spectrum reactor modeling with deterministic method

  • Yichen Yang;Youqi Zheng;Xianan Du;Hongchun Wu
    • Nuclear Engineering and Technology
    • /
    • 제56권6호
    • /
    • pp.2019-2028
    • /
    • 2024
  • Advanced nuclear reactors, especially the newly developed small and micro-reactors have complex neutron spectrum, which makes the deterministic reactor core calculations sensitive to the energy group structure of few-group cross-sections. To avoid significantly increasing the cost of energy discretization in the core calculation, two energy group structures with 31 groups and 33 groups were adopted for typical thermal and fast reactor cores, respectively. Then, an adaptive scheme of group division for reactor cores with a medium neutron spectrum was proposed. The works were based on the full spectrum nuclear reactor analysis code SARAX/TULIP. An equivalent one-dimensional model of the core was proposed to capture the key neutron spectrum features of the reactor core. Such features were used to adaptively determine a few-group structure for the following reactor core calculations. Then, the neutron spectrum in different zones with more details was calculated. With this spectrum, the cross-sections were condensed into the determined energy groups. Three tests based on different neutron spectrum were calculated to verify the schemes. The results show that using the adaptive energy group division scheme, the following core calculation can meet the accuracy requirement of different reactors with different neutron spectra.

수변녹지 조성을 위한 토지매수 우선순위 산정 방안 연구 (A Study on Land Acquisition Priority for Establishing Riparian Buffer Zones in Korea)

  • 홍진표;이재원;최옥현;손주동;조동길;안동만
    • 한국환경복원기술학회지
    • /
    • 제17권4호
    • /
    • pp.29-41
    • /
    • 2014
  • The Korean government has purchased land properties alongside any significant water bodies before setting up the buffers to secure water qualities. Since the annual budgets are limited, however, there has always been the issue of which land parcels ought to be given the priority. Therefore, this study aims to develop efficient mechanism for land acquisition priorities in stream corridors that would ultimately be vegetated for riparian buffer zones. The criteria of land acquisition priority were driven through literary review along with experts' advice. The relative weights of their value and priorities for each criterion were computed using the Analytical Hierarchy Process(AHP) method. Major findings of the study are as follows: 1. The decision-making structural model for land acquisition priority focuses mainly on the reduction of non-point source pollutants(NSPs). This fact is highly associated with natural and physical conditions and land use types of surrounding areas. The criteria were classified into two categories-NSPs runoff areas and potential NSPs runoff areas. 2. Land acquisition priority weights derived for NSPs runoff areas and potential NSPs runoff areas were 0.862 and 0.138, respectively. This implicates that much higher priority should be given to the land parcels with NSPs runoff areas. 3. Weights and priorities of sub-criteria suggested from this study include: proximity to the streams(0.460), land cover(0.189), soil permeability(0.117), topographical slope(0.096), proximity to the roads(0.058), land-use types(0.036), visibility to the streams(0.032), and the land price(0.012). This order of importance suggests, as one can expect, that it is better to purchase land parcels that are adjacent to the streams. 4. A standard scoring system including the criteria and weights for land acquisition priority was developed which would likely to allow expedited decision making and easy quantification for priority evaluation due to the utilization of measurable spatial data. Further studies focusing on both point and non-point pollutants and GIS-based spatial analysis and mapping of land acquisition priority are needed.

분자체 모델을 이용한 수종의 수산화칼슘 제재의 이온 용출에 관한 연구 (A STUDY OF IONIC DISSOCIATION ON VARIOUS CALCIUM HYDROXIDE PASTES USING MOLECULAR SIEVING MODEL)

  • 이경선;박광균;유윤정;이승종
    • Restorative Dentistry and Endodontics
    • /
    • 제27권6호
    • /
    • pp.632-643
    • /
    • 2002
  • The purpose of this study was two-fold. First was to evaluate whether the molecular sieving model was appropriate for ionic dissociation experiment. Second was to compare the dissociation of calcium and hydroxyl ions from five types of calcium hydroxide pastes (Pure calcium hydroxide paste, DT temporary $dressing^{\circledR},{\;}Metapaste^{\circledR},{\;}Chidopex^{\circledR},{\;}Metapex^{\circledR}$) in three vehicles (aqueous, viscous and oily) and the antibacterial effect. Each calcium hydroxide pastes was placed into 0.65ml tube with cap and then 15% polyacrylamide gel was placed onto calcium hydroxide pastes. After the gel was hardened, the tubes were filled with tridistilled water (pH 7.14) and closed with cap. The tubes were stored in $37^{\circ}C$ 100% incubator The pH reading and the concentration of calcium ions were taken at 1, 4, 7. 10, and 14 days. The brain heart infusion agar plates with S. mutans and A. actinomycetemcomitans were used far antibacterial activity test. Middle of agar plate was filled with the calcium hydroxide pastes. The plates were incubated at $37^{\circ}C$ and observations were made to detect the zones of inhibition. These data were evaluated statistically by use of the analysis of variance and duncan test. The results were as follows. 1. In fresh mixing state, the pH of five types of calcium hydroxide pastes were measured between 12.5 and 12.8. 2. The pH was increased in all five types of calcium hydroxide pastes compared with control group. In 14 days, Pure calcium hydroxide paste (11.45) and DT temporary $dressing^{\circledR}$ (11.33) showed highest pH, followed by $Metapaste^{\circledR}$ (9.49), $Chidopex^{\circledR}$ (8.37) and $Metapex^{\circledR}$ (7.59) 3. Calcium was higher in all five types of calcium hydroxide pastes compared with control group. In 14 days, Pure calcium hydroxide paste (137.29 mg%) and DT temporary $dressing^{\circledR}$ (124.6 mg%) showed highest value, followed by $Metapaste^{\circledR}$ (116.74 mg%), $Chidopex^{\circledR}$ (111.84 mg%) and $Metapex^{\circledR}$ (60.22 mg%). 4. The zones of bacterial inhibition were seen around all five types of calcium hydroxide pastes. $Chidopex^{\circledR}{\;}and{\;}Metapex^{\circledR}$ groups which include iodoform were observed significantly larger zone of inhibition in A. actinomycetemcomitans compared with the other calcium hydroxide groups (p<0.05) However, $Metapex^{\circledR}$ showed the least antibacterial effect on S. mutans compared with other groups (p<0.05). The molecular sieving model was found to be acceptable in dissociation experiment of hydroxyl and calcium ions when compared with the previous tooth model study. But this model was not appropriate for the antibacterial test.

농촌 초등교육시설의 통폐합에 따른 통학접근성을 고려한 교육형평성 평가 (Evaluating Educational Fairness of Commuting Distances for Rural Villages following the Closing of Elementary Schools)

  • 김솔희;전정배;서교
    • 한국농공학회논문집
    • /
    • 제62권1호
    • /
    • pp.29-38
    • /
    • 2020
  • Although educational facilities are important considerations from a social equity standpoint, the educational environment generally found in rural areas has been continuously deteriorated due to numerous social problems following birth rate declines and school abolition numbers. The purpose of this study is to evaluate the commuting accessibility changed by the abolition of elementary schools. The village-level accessibility is assessed following physical accessibility criteria based on legally defined commuting distances. Moreover, this study shows the implications of commuting accessibility by school district zones through comparing the minimum commuting distances with real commuting distance. The target area is the Gangwon state, the coverage area in which for schools is the widest in South Korea (44.1 ㎢/school). We evaluated the commuting distances to the nearest elementary school for 992 rural villages and 74 urban villages. Of the 1,066 villages in urban and rural areas evaluated, most of the villages (about 77%) are exposed to commutes to elementary schools were the marginal distance is over 1,000 meters. The annual rate of increase of commuting distance for 1,066 villages in Gangwon state has steadily increased by 2.8%p since 2000, average commuting distance from 2.8 km to 3.6 km. By the designation of the school districts, elementary school students have to go to a faraway school located within administrative district, even though there is a school nearby. It is expected that the results of this study will be made use of as basic data for the establishment of policies such as a reasonable basis for closing schools measurements considering the locally unique environment.

어린이보호구역에 과속경보시스템 적용에 따른 장기적 속도변화 평가 (Assessment of Long-Term Effectiveness of Speed Monitoring Displays on Speed Variation)

  • 이상수
    • 한국안전학회지
    • /
    • 제21권3호
    • /
    • pp.107-113
    • /
    • 2006
  • Speeding is one of major causes of frequent and severe traffic accidents in school zones. In this paper, the long-term effectiveness of speed monitoring displays (SMD) on speed variability was investigated through a field study in a school zone environment. The performance difference was discussed with several dependent variables including average speed, 85th percentile speed, and distribution of speed. Study results showed that the speed of vehicles began to reduce where the driver recognized the presence of an SMD, and about 12.4 percent (5.8km/h) of average speed was reduced at the SMD location. This speed reduction was observed throughout the day regardless of time of day. Statistical tests showed that the speed difference was statistically significant. In addition, analysis results of speed distribution showed that the number of speeding vehicle was greatly reduced after the SMD was installed, and 85th percentile speed also decreased from 54.3km1h to 45.0km/h. Therefore, it was concluded that the application of SMD produced a positive impact on the driver's behavior for a long period of times.

Non-premixed Hydrogen Flame Structure in Supersonic Coflowing Air Flows

  • Kim, Ji-Ho;Kim, Je-Hung;Yoon, Young-Bin;Park, Chul-Woung;Hahn, Jae-Won
    • 한국연소학회지
    • /
    • 제7권1호
    • /
    • pp.1-7
    • /
    • 2002
  • Experiments have been performed to investigate the structure of axisymmetric hydrogen diffusion flame in a supersonic coflow air. The characteristics and structure of supersonic flames are compared with those of subsonic flames as the velocity of coflow air increases from subsonic to supersonic velocity of Mach 1.8. Also, the subsonic and supersonic flow fields are analyzed numerically for the non-reacting conditions and the possible flame contours indicated by fuel mass fraction are compared with the measured OH radical distributions. It is found that the flame structure indicates more like a partially premixed flame as the coflow air velocity is increased from subsonic to supersonic regimes; strong reaction zone indicated by intense OH signal is found at the center, which is different from subsonic flame cases. And it is shown that the fuel jet passes along the recirculation zones behind the bluff-body fuel nozzle resulting in relatively long mixing time. This is believed to be the reason of the partially premixed flame characteristics found in the present supersonic flames.

  • PDF

HSA800 강재의 FCAW 용접성, 용접자세 및 이음성능 연구 (A Study for the Weldability, Welding Position and Welded Joint Performance on the FCAW of HSA800 Steel)

  • 이은택;김종락;최영한;김상섭
    • 한국강구조학회 논문집
    • /
    • 제28권4호
    • /
    • pp.281-292
    • /
    • 2016
  • 본 연구에서는 HSA800 60mm 강재의 FCAW 용접성, 용접자세 및 이음성능을 확인하기 위해 용접자세 1G와 3G에 대한 FCAW 공시체를 제작하여 10종의 시험을 실시하였다. FCAW 1G 및 3G의 시험결과는 HSA800 강재의 KS 및 강도의 균질성에 대한 기준을 만족하며, 양호한 용접부로 나타났다. 그러나 용접부 평판 인장시험결과 FCAW 3G의 경우 용접기술 및 방법의 개선이 필요하다고 판단된다.