• Title/Summary/Keyword: school indoor facilities

Search Result 111, Processing Time 0.026 seconds

Box Model Approach for Indoor Air Quality (IAQ) Management in a Subway Station Environment

  • Song, Jihan;Pokhrel, Rajib;Lee, Heekwan;Kim, Shin-Do
    • Asian Journal of Atmospheric Environment
    • /
    • v.8 no.4
    • /
    • pp.184-191
    • /
    • 2014
  • Air quality in a subway tunnel has been crucial in most of the subway environments where IAQ could be affected by many factors such as the number of passengers, the amount and types of ventilation, train operation factors and other facilities. A modeling approach has been introduced to manage the general IAQ in a subway station. Field surveys and $CO_2$ measurements were initially conducted to analyze and understand the relationship between indoor and outdoor air quality while considering internal pollution sources, such as passengers and subway trains, etc. The measurement data were then employed for the model development with other statistical information. For the model development, the algorithm of simple continuity was set up and applied to model the subway IAQ concerned, while considering the major air transport through staircases and tunnels. Monitored $CO_2$ concentration on the concourse and platform were correlated with modeling results where the correlation values for the concourse and platform were $R^2=0.96$ and $R^2=0.75$, respectively. It implies that the box modeling approach introduced in this study would be beneficial to predict and control the indoor air quality in subway environments.

Classification of Pollution Patterns in High School Classrooms using Disjoint Principal Component Analysis (분산주성분 분석을 이용한 고등학교교실 내 오염패턴분류에 관한 연구)

  • Jang, Choul-Soon;Lee, Tae-Jung;Kim, Dong-Sool
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.6
    • /
    • pp.808-820
    • /
    • 2006
  • In regard to indoor air quality patterns, the government introduced various polices that were about managing and monitoring quality of indoor air as a major assignment, and also executed 'Indoor Air Quality Management Act' which was presented in the May, 2004. However, among the multi-usage facilities controlled by the Act, the school was not included yet. This study goal was to investigate PM 10 pollution patterns of the high school classrooms using a pattern recognition method based on cluster analysis and disjoint principal component analysis, and further to survey levels of inorganic elements in May, June, and September, 2004. A hierarchical clustering method was examined to obtain possible objects in pseudo homogeneous sample classes by transformation raw data and by applying various distance. Following the analysis, the disjoint principal component analysis was used to define homogeneous sample class after deleting outliers. Then three homogeneous Patterns were obtained as follows: the first class had been separated and objects in the class were considered to be sampled under semi-open condition. This class had high concentration of Ca, Fe, Mg, K, Al, and Na which are related with a soil and a chalk compounds. The second class was obtained in which objects were sampled while working air-conditioners and was identified low concentration of PM 10 and elements. Objects in the last class were assigned during rainy day. A chalk, soil element and various types of anthropogenic sources including combustions and industrial influenced the third class. This methodology was thought to be helpful enough to classify indoor air quality patterns and indoor environmental categories when controlling an indoor air quality.

Size Distribution and Concentration of Airborne Fungi in the Public Facilities (다중이용시설 내부에 분포하는 부유 진균의 입경별 농도 특성)

  • Park, Jae-Beom;Kim, Ki-Youn;Jang, Gyu-Yeob;Kim, Chin-Yon;Lee, Kyung-Jong
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.1 s.88
    • /
    • pp.36-45
    • /
    • 2006
  • The aim of this study is to examine size-based concentration and genera of airborne fungi distributed in public facilities such as hospital, kindergarten, day-care center and postpartum nurse center and to provide fundamental data in order to prevent respiratory diseases caused by exposure to airborne fungi. Culturable total and respirable concentrations of airborne fungi averaged to $382\;cfu/m^3\;and\;292\;cfu/m^3$ in hospital, $536\;cfu/m^3\;and\;347\;cfu/m^3$ in kindergarten, $334\;cfu/m^3\;and\;266\;cfu/m^3$ in day-care center, and $371\;cfu/m^3\;and\;289\;cfu/m^3$ in postpartum nurse center, respectively. The ratio of respirable to total concentration of airborne fungi in the investigated public facilities was ranged from $55\%\;to\;70\%$ but there was no significant difference among them (p>0.05). The mean I/O ratio of culturable total and respirable concentrations were 0.56 and 0.64 in hospital, 0.72 and 0.91 in kindergarten, 0.33 and 0.45 in day-care center, and 0.63 and 0.73 in postpartum nurse center, respectively. Indoor concentration of airborne fungi did not correlated significantly with indoor temperature and relative humidity (p>0.05) but had a significant positive correlation with $CO_2$ concentration (p<0.01) and surrounding condition (p<0.05). Penicillium spp., Cladosporium spp., and Aspergillus spp. were estimated to over $95\%$ of total airborne fungi identified in the investigated public facilities.

Model Study on the Level of Satisfaction for Recreation Forest Accommodations (자연휴양림 숙박시설만족도 모형연구)

  • Lee, Kee-Cheol;Kang, Kee-Rae
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.34 no.6 s.119
    • /
    • pp.78-86
    • /
    • 2007
  • Research into the use of recreation forest accommodations, the main facilities in these forests, and user satisfaction with them has been carried out for recreation forests in the suburbs of Daegusi and Gyongsangbukdo. This study aimed at providing background material to support the increasing demand to improve the facilities of recreation forests and to educate recreation forest staff about how to provide better service. User satisfaction with recreation forests as determined through regression analysis was affected by the following factors in this order: indoor recreation, the indoor space, outdoor recreation, time satisfaction factor, and activity opportunities. The level of satisfaction is affected by the force of factors above. The order of effective offerings of accommodations is presented according to the results.

A Study on the Variation of Airflow Velocity and Temperature upon the Design of Bio Clean Room(BCR) for Laboratory Animal Facilities by Numerical Simulation (실험동물 사육실용 바이오 크린룸(BCR)의 급기 온도 및 풍속 변화 특성에 관한 수치해석적 연구)

  • Park, Dong-Il;Chung, Kwang-Seop;Kim, Young-Il;Kim, Sung-Min
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.7
    • /
    • pp.578-584
    • /
    • 2012
  • In this study, the analysis on the distribution of indoor airflow velocity and temperature by using numerical simulation has carried out to make fundamental data for establishing the optimum design of laboratory animal facilities. From the results, it was found that replacement of cage lacks, air supply and exhaust system, supply air temperature, supply air velocity affect to the optimum design of laboratory animal facilities as a important element.

A Study on the Environmental Planning Guidelines for Crime Safety at Elementary School settings (초등학교 교육환경의 범죄안전 환경계획방안에 관한 연구)

  • Byun, Gi-Dong;Ha, Mi-Kyoung
    • Korean Institute of Interior Design Journal
    • /
    • v.22 no.2
    • /
    • pp.211-219
    • /
    • 2013
  • The purpose of this study is to propose the environmental planning guidelines of elementary school settings for a crime safety. The research methodologies To achieve the goal, the literature review analysis and the survey were used as main research methodologies. The survey is organized as follows. First, elementary education facilities were divided into 20 spaces based on the major space. Second, after analyzing the domestic and foreign CPTED Guidelines, elements of environmental planning were classified to fit in the space. Based on this, the expert survey was conducted. The results of this study are as follows; First, it is necessary to consider specific places such as 'toilets', 'parking lot', 'in-between space', 'main access road', 'sub-access road' and 'harmful facilities around school' for safer school environment. Second, it is significant to plan 'equipment facilities' and 'outdoor space in the school setting' with priority for elementary education environment. Third, environmental planning elements for safer elementary schools can be classified into 9 factors(types) including 'natural surveillance planning', 'territoriality reinforcement planning', 'mechanical surveillance planning', 'access control planning' and 'neighborhood reinforcement planning'. Forth, regarding 'indoor space', crime-free elementary school environment can be build through 'natural surveillance planning' and 'territoriality reinforcement planning'. Finally, regarding 'outdoor space', the crime can be prevented through 'natural surveillance planning' and 'access control planning'.

A Study on the using of the Ventilation System as the Method of Improvement of Air Quality in the Schools (학교건물의 공기질 개선을 위한 환기시스템 적용에 관한 연구)

  • Ahn, Chul-Lin;Kim, Jwa-Jin;Kum, Jong-Soo;Park, Hyo-Soon
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.11 no.2
    • /
    • pp.17-23
    • /
    • 2004
  • The purpose of this study concerns the improvement of air quality in school classrooms. Polluted indoor air is improved by efficient ventilation systems. So it is important to measure the amount of ventilation needed in classrooms. First, the amount of natural ventilation were measured through a tracer gas method. And we have established a heat recovery ventilation system from 4 cases of airflow in classrooms, and we have measured the change of $CO_2$ density. According to air quality measurements in the classrooms, the density of $CO_2$ is well above environmental standards which are acceptable. When the amount of ventilated airflow increases, indoor air quality is improved. It is surveyed that the most suitable amount of external inducted air is 770 CMH to satisfy $CO_2$ less than 1,000 ppm in classrooms. For improvement of air quality in classrooms, we must consider a suitable ventilation plan and installation of ventilation systems when constructing school buildings.

A Study on Improvement of Discharge Pressure Measurement of Indoor Fire Hydrant System (옥내소화전설비의 방수압 측정 개선에 관한 연구)

  • Min, Se-Hong;Jeong, Sang-Ho
    • Fire Science and Engineering
    • /
    • v.26 no.3
    • /
    • pp.67-72
    • /
    • 2012
  • Indoor fire hydrant facilities and sprinkler system applied to the initial fire suppression for buildings' interior fire are pivotal roles in extinguishing the fire in the early stage. The roof shapes of recent buildings combined with distinctive local culture and design are being constructed. Distinctive roof forms, i.e. gable roof buildings are planned and built, View point planning with the roof gardens also restricts measurement of the discharge pressure on the indoor fire hydrant, It is too narrow to gauge the water discharge pressure with deploying up to 5 water hoses. To resolve these problems improvement for the efficient management of indoor fire hydrant system and the effective early stage flame extinguishment is suggested.

A Study on Indoor Environment Safety Level Certification of Educational Facilities and School Safety Level Evaluation (교육시설 안전 등급 인증과 학교 안전도 심사에 대한 연구)

  • Myoung-Kwan Kim;Young-Guk Kwon
    • Journal of the Korea Safety Management & Science
    • /
    • v.25 no.2
    • /
    • pp.17-28
    • /
    • 2023
  • This study aimed to verify the validity of the evaluation items and weight determination of the indoor environmental safety area, which has the most frequent accidents, among the safety certification evaluations of educational facilities by the Ministry of Education of the Republic of Korea, which has been conducted since May 2021. As a preceding study, the evaluation items of the school safety evaluation checklist being implemented in the US state of Vermont were compared, and the causes of accidents judged by teachers in the accident experiences written by 200 Korean teachers were compared with the safety certification evaluation items belonged to the Ministry of Education. In addition, research literature using the AHP analysis technique on safety risks of elementary and secondary schools in China and safety evaluation index study cases of 539 elementary school children in Indonesia were analyzed. Through these preceding studies, measures to add and adjust evaluation items were derived and the validity and importance rankings of evaluation items were calculated through AHP questionnaires to teachers and safety experts. In addition, a survey was conducted on 104 ordinary people to verify the results of expert analysis. As a result of expert AHP analysis, 'safety education and disaster response training (.396)' was the highest priority for the relative importance of the first layer, followed by 'safety measures (.387)' and 'building materials'. Safety (.216)' was found to be the highest priority. In the overall importance ranking of the 13 second-tier screening items, safety accident prevention education had the highest priority and disaster preparedness training ranked second, proving that the Ministry of Education's review weight was underestimated. In addition, slip and collision accident countermeasures, which were not in the existing Ministry of Education review items, ranked 4th, laboratory practice room safety measures ranked 6th, and sanitation, cleanliness, hazardous substance management, and cafeteria/cooking room safety measures ranked 9th, indicating a significant level of importance. Referring to the importance ranking, which is the result of this study, it is suggested that it is necessary to review the weight of each review item again.

The Characterization of Carbonyl Compounds in the Newly-Built Schools, Daegu City (대구지역 신축학교 실내공기 중 카보닐화합물의 농도 특성 평가)

  • Hwang, Yoon-Jung;Park, Hee-Sun;Jang, Seong-Il;Roh, Ki-Cheul;Son, Tae-Jung;Han, Jeong-Wook;Bae, Gi-Soo;Choi, Im-Jo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.6
    • /
    • pp.831-841
    • /
    • 2006
  • The study on school indoor air quality was carried out at classrooms, computer-rooms, laboratories and play- grounds for carbonyl compounds including formaldehyde during the winter time from November to December 2004 and during the summer time from June to July 2005. The sampling was conducted under the general school condition without any artificial intervention such as the sealing, ventilating or heating at indoor environments. The concentrations of formaldehyde at all types of indoor environments were lower than air quality standard of $120{\mu}g/m^3$ for public facilities. The mean concentrations of formaldehyde at indoors were $4.5{\sim}6.1$ times higher than those at outdoors. From the comparison between two year and one year old schools after construction, the concentrations of formaldehyde in two year old school were $30{\sim}38%$ lower than those in one year old school measured at classrooms and laboratories.