• 제목/요약/키워드: school drop-out

검색결과 172건 처리시간 0.026초

자동차 냉/난방 성능 향상을 위한 공기조화 덕트의 기류해석 (Aerodynamic Analysis of Automotive HVAC Duct for Enhancement of Cooling/Heating Performance)

  • 주재우;이기돈;허만웅;김광용;박준규;윤정환;김홍빈
    • 설비공학논문집
    • /
    • 제24권1호
    • /
    • pp.23-28
    • /
    • 2012
  • In the present work, numerical analyses of air flow in HVAC duct have been carried out for enhancement of cooling/heating performance. For the analyses, three-dimensional Reynolds-averaged Navier-Stokes equations have been solved with the shear stress transport turbulence model. The numerical results were validated in comparison with the experimental data. Based on the numerical results, the HVAC duct was designed to reduce the pressure loss. The modified duct geometry shows largely reduced pressure drop in comparison with the reference geometry. And, through modified duct shape, the performance of air conditioning has been enhanced.

미소 사각 채널에서의 마찰 압력 강하 (Pressure Drop due to Friction in Small Rectangular Channel)

  • 임태우;최재혁;김준효;최용석
    • 해양환경안전학회지
    • /
    • 제18권5호
    • /
    • pp.461-467
    • /
    • 2012
  • $500{\mu}m$의 수력직경을 가진 마이크로 채널에서 유동 비등 시 물에 대한 마찰 압력 강하를 측정하기 위한 실험적 연구를 수행하였다. 실험은 열 유속 $100-400kW/m^2$, 증기건도 0-0.2 그리고 질량 유속 $200-600kg/m^2s$의 범위에서 이루어졌다. 유동 비등 시 마찰 압력 강하는 두 가지 모델을 사용하여 예측된다. 즉, 두 상의 속도가 동일하다고 가정한 균질 모델과 두 상 사이에 서로 다른 속도를 가지는 분리류 모델로 분류된다. 실험결과 이상 마찰 승수는 질량 유속이 증가함에 따라 감소한다는 것을 알 수 있었다. 측정된 압력 강하 데이터는 매크로 스케일과 미니/마이크로 스케일에서 제안된 기존의 여러 상관식들과 비교하였다. 균질 모델은 본 연구에서 고려한 실험 조건에서 29.4 %의 평균 오차내에서 마찰 압력 강하를 예측하였다.

고분자 수지 이송 성형에서 브레이드 프리폼의 두께방향 투과율 계수 측정 (Out-of-Permeability Measurement of the Braided Preform in Resin Transfer Molding)

  • Suk, Chae-Hui;Seok, Song-Yeong;Ryun, Yun-Jae
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2003년도 추계학술발표대회 논문집
    • /
    • pp.87-90
    • /
    • 2003
  • In Resin transfer molding (RTM), composite parts are produced by impregnation of a dry reinforcement with liquid matrix resin. Permeability is a key issue in this process. For thin parts, the resin flow in the thickness direction can be neglected. Therefore thin parts are considered as two-dimensional composites. However the resin flow through the thickness is important to thicker parts and we have to consider out-of-plane permeability. This work discusses a method to measure out-of-plane permeability. The flow rate and pressure drop across the porous media were measured. Also one dimensional form of Darcy's law is applied to calculate the out-of-plane permeability of various preforms. The flow is injected uniformly into layers of the preform. And a circular fiber mat with 6cm diameter was cut and flattened from cylindrical mandrel.

  • PDF

Vibration behavior of large span composite steel bar truss-reinforced concrete floor due to human activity

  • Cao, Liang;Li, Jiang;Zheng, Xing;Chen, Y. Frank
    • Steel and Composite Structures
    • /
    • 제37권4호
    • /
    • pp.391-404
    • /
    • 2020
  • Human-induced vibration could present a serious serviceability problem for large-span and/or lightweight floors using the high-strength material. This paper presents the results of heel-drop, jumping, and walking tests on a large-span composite steel rebar truss-reinforced concrete (CSBTRC) floor. The effects of human activities on the floor vibration behavior were investigated considering the parameters of peak acceleration, root-mean-square acceleration, maximum transient vibration value (MTVV), fundamental frequency, and damping ratio. The measured field test data were validated with the finite element and theoretical analysis results. A comprehensive comparison between the test results and current design codes was carried out. Based on the classical plate theory, a rational and simplified formula for determining the fundamental frequency for the CSBTRC floor is derived. Secondly, appropriate coefficients (βrp) correlating the MTVV with peak acceleration are suggested for heel-drop, jumping, and walking excitations. Lastly, the linear oscillator model (LOM) is adopted to establish the governing equations for the human-structure interaction (HSI). The dynamic characteristics of the LOM (sprung mass, equivalent stiffness, and equivalent damping ratio) are determined by comparing the theoretical and experimental acceleration responses. The HSI effect will increase the acceleration response.

Characterization of flow properties of pharmaceutical pellets in draft tube conical spout-fluid beds

  • Foroughi-Dahr, Mohammad;Sotudeh-Gharebagh, Rahmat;Mostoufi, Navid
    • Journal of Industrial and Engineering Chemistry
    • /
    • 제68권
    • /
    • pp.274-281
    • /
    • 2018
  • Experimental studies of the hydrodynamic performance of the draft tube conical spout-fluid bed (DCSF) were conducted using pharmaceutical pellets. The experiments were carried out in a DCSF consisted of two sections: (a) a conical section with the cross section of $120mm{\times}250mm$ and the height of 270 mm, (b) a cylindrical section with the diameter of 250 mm and the height of 600 mm. The flow characteristics of solids were investigated with a high speed camera and a pezoresistive absolute pressure transducer simultaneously. These characteristics revealed different flow regimes in the DCSF: packed bed at low gas velocities, fluidized bed in draft tube at higher gas velocities until minimum spouting, and spouted bed. The stable spouting was identified by the presence of two dominant frequencies of the power spectrum density of pressure fluctuation signature: (i) the frequency band 6-9 Hz and (ii) the frequency band 12-15 Hz. The pressure drops across the draft tube as well as the annulus measured in order to better recognize the flow structure in the DCSF. It was observed that the pressure drop across the draft tube, the pressure drop across the annulus, and the minimum spouting velocity increase with the increase in the height of draft tube and distance of the entrainment zone, but with the decrease in the distributor hole pitch. Finally, this study provided novel insight into the hydrodynamic of DCSF, particularly minimum spouting and stable spouting in the DCSF which contains valuable information for process design and scale-up of spouted bed equipment.

용접식 판형열교환기에서 작동유체의 유량과 온도변화에 따른 성능특성 고찰 (Investigation of Performance Characteristics in a Welded Plate Heat Exchanger according to Mass flow rate and Temperature)

  • 함정균;김민준;안성국;조홍현
    • 한국지열·수열에너지학회논문집
    • /
    • 제14권4호
    • /
    • pp.20-26
    • /
    • 2018
  • In this study, the performance characteristics of a welded plate heat exchanger was investigated experimentally. Performance tests were carried out according to the flow rate and inlet temperature of working fluid. As a result, the heat transfer capacity increased by 335.5 kW with an increasing the flow rate and temperature difference between hot and cold side. However, the overall heat transfer coefficient was increased with the increase of flow rate, and it was not effected significantly from inlet temperature difference between hot and cold working fluid. The pressure drop was increased by 55.78 kPa with an increasing the frow rate when the flow rate ratio between hot and cold side 1:1. However, the tendency of pressure drop was difference when flow rate ratio wasn't 1:1. In case that the flow rate ratio between hot and cold side was not 1:1, the pressure drop at the low flow rate side was higher than that when the flow rate ratio was 1:1, while pressure drop of the other side was decreased compared to that when the flow rate ratio was 1:1.

Al 6082-T6 MIG 용접에서 기공방지를 위한 용접공정 개발 (The Development of Welding Process to Prevent Porosity in MIG Welding of Al 6082-T6)

  • 백상엽;정연호;김원일;조상명
    • Journal of Welding and Joining
    • /
    • 제28권6호
    • /
    • pp.28-34
    • /
    • 2010
  • This paper was described on investigation to prevent porosity in high speed MIG Welding of Al 6082-T6. Porosity measurement was carried out by using image analysis of micrographs with the help of an analysis software. The main parameter was arc length and torch progressive angle. The porosity ratio was increased as arc length was increased. The arc length was increased depending upon the output voltage. By proper selection of pulse waveform parameter, the stable arc of one pulse one drop was generated. The porosity ratio of optimum condition in one pulse one drop was lower than high voltage condition. When torch progressive angle was an angle of advance $10^{\circ}$, porosity ratio was minium.

냉매 R1234yf 적용 자동차용 에어컨 Drop-in 성능 특성 (Performance Characteristics of a Drop-in System for a Mobile Air Conditioner Using Refrigerant R1234yf)

  • 조홍현;이호성;박차식
    • 설비공학논문집
    • /
    • 제24권12호
    • /
    • pp.823-829
    • /
    • 2012
  • In this study, the performance of mobile air conditioner(MAC) systems to which the refrigerants R134a and R1234yf were used was evaluated to compare the characteristic of automotive refrigeration cycles with refrigerant. The experimental setup of a MAC consists of an belt driven compressor, a condenser, an evaporator and a block type thermal expansion valve. The drop-in test on MAC were carried out under variable compressor speed from 800 to 2500 rpm. Performance test by using R1234yf and R134a in the same system revealed low the charge amount and mass flow rates for using R1234yf, that is, up to 10% and 17%, respectively. The compressor discharge temperature of R1234yf is $8^{\circ}C$ lower than that of R134a. The cooling capacity with R1234yf system decreased by 4~7% compared with R134a system. In addition, The COP of R1234yf system is lower 3~4% than that of R134a system.

판형열교환기의 열에너지 성능평가 (Evaluation on Thermal Energy Performance of a Plate Heat Exchanger)

  • 강병하;김도규
    • 한국수소및신에너지학회논문집
    • /
    • 제14권1호
    • /
    • pp.53-60
    • /
    • 2003
  • Performance evaluation on thermal transport of a plate heat exchanger has been carried out. The $\varepsilon$-Ntu method is employed to evaluate the performance of a brazed type of plate heat exchanger. This problem is of particular interest in the design of a plate heat exchanger. The characteristics of heat transfer as well as pressure drop are studied in the wide range of Reynolds numbers in the cold side while that of hot side is fixed at 620. f-factor correlation in a plate heat exchanger is obtained from the pressure drop data. It is also found that the effectiveness of the plate heat exchanger is increased as the Ntu is increased.

순산소 분위기에서 촤 연소 및 질소산화물 배기특성 비교 (Comparative Study of Char Burn-Out and NOx Emissions in O2/N2 and O2/CO2 environments)

  • 이천성;김성곤;이병화;장영준;전충환;송주헌
    • 에너지공학
    • /
    • 제20권3호
    • /
    • pp.191-199
    • /
    • 2011
  • 본 연구에서는 Drop Tube Furnace(DTF)를 이용한 $O_2/N_2$, $O_2/CO_2$ 조건에서 산소 농도(12, 21, 31%)에 따른 아역청탄 입자의 연소특성 및 질소산화물 배출특성에 관한 실험과 수치해석을 수행하였다. $O_2/N_2$, $O_2/CO_2$ 조건에서 산소 농도가 증가함에 따라 촤 연소율이 증가하였고 $O_2/CO_2$ 조건하에서 이산화탄소 경계층에서 석탄입자 표면으로의 산소 확산계수가 낮아지기 때문에 촤 연소율이 감소하였다. 산소 농도가 증가함에 따라 배출되는 NO의 농도는 증가하지만 완전 연소 조건인 31%의 산소 농도에서는 오히려 NO의 농도가 감소하였다. 반면, NO 배출 지수는 산소가 증가함에 따라 점차 감소하였다. $O_2/CO_2$ 조건에서 NO의 농도는 Thermal NO의 결여로 인해 $O_2/N_2$ 조건보다 작게 나타났다.