• 제목/요약/키워드: school building

검색결과 4,240건 처리시간 0.039초

발파해체현장에서 발생하는 순간분진의 입경분포 특성 (Characteristics of Particle Size Distributions Generated in the Vicinity of Building Blasting Demolition Sites)

  • 이경희;김효진;박찬규;고광백
    • 한국환경과학회지
    • /
    • 제18권1호
    • /
    • pp.41-47
    • /
    • 2009
  • In building demolition work, major dust-generating activities are blasting concrete and rock. The aim of this study was to find the characteristic of particle size of dusts which were generated during building demolition work using explosion. The DustMate of the Turnkey-Instruments Ltd. was used for particulate size-selective sampling of the four sites. TSP(Total Suspended Particle), PM10(Particle Matter $10{\mu}m$), PM2.5(Particle Matter $2.5{\mu}m$), and PM1.0(Particle Matter $1.0{\mu}m$) were measured during building demolition work using explosion. The large particulate (higher than the diameter $10{\mu}m$) showed to be higher than 50%. The particulate ranged from $10{\mu}m\;to\;2.5{\mu}m$ showed about 30-40%. PM2.5 was not scarcely detected in the samples collected for building demolition work using explosion. We conclude that the dust generated during building demolition work using explosion has not most respirable particulate.

건물에너지 저감을 위한 PCM/diatomite composites의 제조 및 특성 분석 (Preparation and characteristic analysis of PCM/diatomite composites for building energy saving)

  • 전지수;정수광;김수민
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.470-474
    • /
    • 2012
  • This paper deals with the thermal performances of PCM/diatomite composites for energy saving. The PCM/diatomite composites were prepared by incorporating PCMs in the pores of diatomite to increase form stability of PCMs. In experiment, we used the hexadecane, octadecane and paraffin as PCM and they have each 254.7 J/g, 247.6 J/g and 144.6 J/g of latent heat capacity, and those melting points are $20.84^{\circ}C$, $30.40^{\circ}C$ and $57.09^{\circ}C$, respectively. Thermal properties of PCM/diatomite composites were determined by using DSC. And PCM/diatomite composites were characterized by SEM and FTIR analysis. The results showed that the PCMs are well infiltrated into the structure of diatomite andt he latent heat capacity of PCM/diatomite composites was obtained by 40% of pure PCMs.

  • PDF

고층빌딩 외벽 유지관리 로봇 시스템 조사연구 (A Survey on Robot Systems for High-rise Building Wall Maintenance)

  • 문성민;허재명;이승훈;강성필;한창수;홍대희
    • 한국정밀공학회지
    • /
    • 제30권4호
    • /
    • pp.359-367
    • /
    • 2013
  • With recent growth of the economy and development of construction technology, the increase of high-rise buildings is appearing rapidly in urban areas. For this reason, the interest in building maintenance has also been increasing. However, it has many safety problems because it is difficult for the workers to access the exterior wall of building. Therefore, the maintenance system of high-rise building stands out as being important issues to be developed, so that a variety of robot systems have been developed to accomplish the building-wall maintenance works. In this paper, the maintenance robots are classified in painting, inspecting, cleaning systems according to the maintenance works. Then, their locomotion and adhesion mechanisms are analyzed including their applicability to the real maintenance works. This study can be used to develop maintenance robotic system that is more efficient and stable than existing ones.

건축물 에너지 시뮬레이션 적용을 위한 목재 열전도율 데이터베이스 구축 (Wood Thermal Conductivity Database Construction for the Application of Building Energy Simulation)

  • 서정기;강유진;김수민
    • 한국가구학회지
    • /
    • 제27권2호
    • /
    • pp.122-127
    • /
    • 2016
  • The increasing interest in the environment and climate change around the globe, while the importance of building energy saving is increasing. The building energy simulation program is used for evaluating of energy performance of buildings. However, an input value of wood thermal conductivity in the programs is different from each other. Therefore, in this study, wood thermal conductivity was measured according to species. Through construction database by species of wood, the error of simulation program are able be decreased. In addition, if used as a structural and interior of buildings, the thermal conductivity and moisture of the wood is difficult to apply to the program because they were changed according to the occupant's lifestyle. In this paper, thermal conductivity and moisture content.of wood confirmed changes in the constant temperature and relative humidity ($25^{\circ}C$, 50% R.H.) condition.

부하예측 외기냉방에 의한 건물에너지 절약에 관한 연구 (A Study on Building Energy Saving using Outdoor Air Cooling by Load Prediction)

  • 김태호;유성연;김명호
    • 설비공학논문집
    • /
    • 제29권2호
    • /
    • pp.43-50
    • /
    • 2017
  • The purpose of this study is to develop a control algorithm for outdoor air cooling based on the prediction of cooling load, and to evaluate the building energy saving using outdoor air cooling. Outdoor air conditions such as temperature, humidity, and solar insolation are predicted using forecasted information provided by the meteorological agency, and the building cooling load is predicted from the obtained outdoor air conditions and building characteristics. The air flow rate induced by outdoor air is determined by considering the predicted cooling loads. To evaluate the energy saving, the benchmark building is modeled and simulated using the TRNSYS program. Energy saving by outdoor air cooling using load prediction is found to be around 10% of the total cooling coil load in all locations of Korea. As the allowable minimum indoor temperature is decreased, the total energy saving is increased and approaches close to that of the conventional enthalpy control.

제로에너지 스쿨을 위한 초등 교육시설의 에너지 성능평가 (Energy Performance Evaluation of A Primary School Building for Zero Energy School)

  • 윤종호;신우철;조진일;박재완;김효중;이철성
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 춘계학술발표대회 논문집
    • /
    • pp.121-126
    • /
    • 2009
  • This study analyzed the standard school's energy usage and patterns as the zero-energy goal of primary school building, and proposed the energy reduction process of school building using energy analysis computing simulation tool. As a analysis simulation tool, Visual DOE 4.0 is used. For analysis of actual energy usage, selected primary school that is standard in the nation's energy consumption. Standard of the school's energy consumption analysis were devided into electric and gas energy. Input parameters of the simulation program based on the literature material and field survey material. after, but it was calibrated to comparison with the standard school's energy consumption. Finally, its energy usage analyzed by component and made the priority order of energy saving. Applied energy saving technologies are envelopment insulation, high efficiency lighting, high performance HAVC system and used active equipment system of solar collector and photovoltaic generation for additional savings.

  • PDF

국내 기존 학교건축물의 내진보강 후 비선형 거동특성 (Nonlinear Behavior of Seismic-Strengthened Domestic School Building)

  • 류승현;윤현도;김선우;이강석;김용철
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제15권1호
    • /
    • pp.243-253
    • /
    • 2011
  • 본 논문은 내진설계규정이 적용되지 않은 국내 철근콘크리트 학교 건물에 관한 해석적 연구이다. 일본의 내진진단과 비선형 정적 및 동적 해석을 통하여 대상 건축물의 내진 성능을 평가하였다. 일본의 내진진단 방법에 기초하여 철근 콘크리트 학교 건물의 부족한 내진 성능을 파악하였다. 또한, 횡하중을 받는 학교 건물의 내진거동이 해석적으로 평가되었다. 건축물의 내진 보강을 위하여 1,300kN의 내력을 받는 전단벽과 K형 가새골조가 사용되었다. 비선형 정적해석 결과, 보강에 의한 전단내력은 보강 전에 비하여 30%이상의 향상을 보이는 것으로 나타났으며, 전단벽 보강 시 최대 하중 이후에서 가새골조 보강에 비해 큰 강성저하를 나타내었다. 또한, 성능점 산정 결과에서 가새골조로 보강된 건축물이 전단벽으로 보강된 건축물에 비해 30% 이상의 변형능력을 보였다. 한편 비선형 동적해석의 시간이력해석 결과에서는 가새골조와 전단벽에 의해 보강된 건축물의 최대 변위가 보강량이 증가할수록 감소하는 경향을 나타내었다. 본 연구는 이 외에도 지진 지역에서의 건축물의 내진성능 향상을 위해 다양한 지반 조건과 지진파를 고려되어야 한다고 판단된다.

사무소건물의 규모 및 배치유형에 따른 하기 옥외 복사열환경 평가 (Evaluation of the Outdoor Radiant Thermal Environment by Building Scale and Block Type of Office Building in Summer)

  • 박수진;정선영;윤성환
    • 한국태양에너지학회 논문집
    • /
    • 제29권6호
    • /
    • pp.81-87
    • /
    • 2009
  • The purpose of this study is to evaluate of the outdoor thermal environment by building scale and block type as variable factors. In this study, 18 cases of office in central business district that have different condition are compared about their surface temperature, HIP(Heat Island Potential), and MRT(Mean Radiant Temperature). They are simulated with 3-dimension numerical simulation software named Hoyano-model. The output results contain visualized distribution chart and numerical data. The results of evaluation are as follows. (1)The surface temperature of the building becomes higher as building coverage ratio is higher but floor area ratio is lower. In same conditions, unified block type is maximum $3.2^{\circ}C$ higher than divided block type. (2)HIP shows different daily pattern as block type. During daytime, divided block type is much higher than unified block type but after sunset, it is changed. (3)MRT shows different distribution pattern as sunlight moves expecially at noon. (4)As the results of this study, cases that have high floor area ratio condition show lower surface temperature by tendency to stay low indoor temperature in office building and big rate of windows on building surface.

건물에너지사용특성이 신재생에너지시스템 최적화 비율에 미치는 영향분석 (Analysis of Effects of Building Energy Consumption Characteristics on the Optimization Ratio for New and Renewable Energy Systems)

  • 이용호;홍준호;김용경;조영흠;황정하
    • 한국태양에너지학회 논문집
    • /
    • 제34권5호
    • /
    • pp.117-126
    • /
    • 2014
  • This study developed a KRESS program designed to find the optimization ratio for new and renewable energy systems and analyze the effects of building energy consumption characteristics on the ratio. In spite of clear differences in predicted energy consumption and energy consumption by the loads among 18 facilities, the current formula for obligatory supply ratios applies a correction coefficient according to the building purposes based on energy consumption per each unit area in medical facilities and thus reflects no energy consumption characteristics according to the building purposes. The optimization ratio for new and renewable energy systems was the same for all facilities when the correction coefficients by the building purposes and new and renewable energy sources were all applied. When the correction coefficients were not applied, however, the optimization ratio varied according to building energy consumption characteristics. The findings raise a need to test the correction coefficients in order to select new and renewable energy systems that take into account energy consumption characteristics by the building purposes and loads and reflect economy, environmental performance, and technology.

운봉 향교 정밀 모니터링을 통한 목재 기둥 부재의 함수율 분포 특성 (Study on Moisture Contents Distribution of Wooden Post Member by Precise Monitoring in Un-Bong Confucian School)

  • 박천영;김광철
    • 한국가구학회지
    • /
    • 제24권1호
    • /
    • pp.104-112
    • /
    • 2013
  • Monitoring for moisture contents of wooden post member of Un-bong confucian school was performed in 6 months and analyzed to conserve scientifically the wooden culture building and open for common people. In inner post member of the building, variation of moisture contents was very small and upper part had relatively higher moisture contents. In outer post member, moisture contents were changed according to the weather conditions and was relatively high in bottom and upper part. Southern post has lower moisture content than eastern. These results were related to air ventilation in interior, depth of eaves and orientation of the building. In the design, construction and maintenance of wooden building, characteristics of wood should be considered like moisture contents.

  • PDF