• Title/Summary/Keyword: scanning probe microscopy

검색결과 273건 처리시간 0.03초

원자힘현미경을 이용한 탄화규소 미세 패터닝의 Scanning Kelvin Probe Microscopy 분석 (Scanning Kelvin Probe Microscope analysis of Nano-scale Patterning formed by Atomic Force Microscopy in Silicon Carbide)

  • 조영득;방욱;김상철;김남균;구상모
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 추계학술대회 논문집
    • /
    • pp.32-32
    • /
    • 2009
  • Silicon carbide (SiC) is a wide-bandgap semiconductor that has materials properties necessary for the high-power, high-frequency, high-temperature, and radiation-hard condition applications, where silicon devices cannot perform. SiC is also the only compound semiconductor material. on which a silicon oxide layer can be thermally grown, and therefore may fabrication processes used in Si-based technology can be adapted to SiC. So far, atomic force microscopy (AFM) has been extensively used to study the surface charges, dielectric constants and electrical potential distribution as well as topography in silicon-based device structures, whereas it has rarely been applied to SiC-based structures. In this work, we investigated that the local oxide growth on SiC under various conditions and demonstrated that an increased (up to ~100 nN) tip loading force (LF) on highly-doped SiC can lead a direct oxide growth (up to few tens of nm) on 4H-SiC. In addition, the surface potential and topography distributions of nano-scale patterned structures on SiC were measured at a nanometer-scale resolution using a scanning kelvin probe force microscopy (SKPM) with a non-contact mode AFM. The measured results were calibrated using a Pt-coated tip. It is assumed that the atomically resolved surface potential difference does not originate from the intrinsic work function of the materials but reflects the local electron density on the surface. It was found that the work function of the nano-scale patterned on SiC was higher than that of original SiC surface. The results confirm the concept of the work function and the barrier heights of oxide structures/SiC structures.

  • PDF

Scanning Kelvin Probe Microscopy를 이용한 SiC 소자의 분석 (Scanning Kelvin Probe Microscopy analysis of silicon carbide device structures)

  • 조영득;하재근;고중혁;방욱;김상철;김남균;구상모
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 하계학술대회 논문집 Vol.9
    • /
    • pp.132-132
    • /
    • 2008
  • Silicon carbide (SiC) is an attractive material for high-power, high-temperature, and high-frequency applications. So far, atomic force microscopy (AFM) has been extensively used to study the surface charges, dielectric constants and electrical potential distribution as well as topography in silicon-based device structures, whereas it has rarely been applied to SiC-based structures. In this work, the surface potential and topography distributions SiC with different doping levels were measured at a nanometer-scale resolution using a scanning kelvin probe force microscopy (SKPM) with a non-contact mode AFM. The measured results were calibrated using a Pt-coated tip and a metal defined electrical contacts of Au onto SiC. It is assumed that the atomically resolved surface potential difference does not originate from the intrinsic work function of the materials but reflects the local electron density on the surface. It was found that the work function of the Au deposited on SiC surface was higher than that of original SiC surface. The dependence of the surface potential on the doping levels in SiC, as well as the variation of surface potential with respect to the schottky barrier height has been investigated. The results confirm the concept of the work function and the barrier heights of metal/SiC structures.

  • PDF

Two-dimensional Surface Structures of Arenthiols Studied by STM

  • 권기영
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제42회 동계 정기 학술대회 초록집
    • /
    • pp.89-89
    • /
    • 2012
  • Arrangement of individual atoms and molecules with atomic precision and understanding the resulting properties at the molecular level are ultimate goals of chemistry, biology, and materials science. For the past three decades, scanning probe microscopy has made strides towards these goals through the direct observation of individual atoms and molecules, enabling the discovery of new and unexpected phenomena. This talk will discuss the origin of forces governing motion of small organic molecules and their extended self-assembly into two-dimensional surface structures by direct observation of individual molecules using scanning tunneling microscopy (STM).

  • PDF

The Electrical Characterization of Magnetic Tunneling Junction Cells Using Conductive Atomic Force Microscopy with an External Magnetic Field Generator

  • Heo, Jin-Hee
    • Transactions on Electrical and Electronic Materials
    • /
    • 제11권6호
    • /
    • pp.271-274
    • /
    • 2010
  • We examined the tunneling current behaviors of magnetic tunneling junction (MTJ) cells utilizing conductive atomic force microscopy (AFM) interfaced with an external magnetic field generator. By introducing current through coils, a magnetic field was generated and then controlled by a current feedback circuit. This enabled the characterization of the tunneling current under various magnetic fields. The current-voltage (I-V) property was measured using a contact mode AFM with a metal coated conducting cantilever at a specific magnetic field intensity. The obtained magnetoresistance (MR) ratios of the MTJ cells were about 21% with no variation seen from the different sized MTJ cells; the value of resistance $\times$ area (RA) were 8.5 K-12.5 K $({\Omega}{\mu}m^2)$. Since scanning probe microscopy (SPM) performs an I-V behavior analysis of ultra small size without an extra electrode, we believe that this novel characterization method utilizing an SPM will give a great benefit in characterizing MTJ cells. This novel method gives us the possibility to measure the electrical properties of ultra small MTJ cells, namely below $0.1\;{\mu}m\;{\times}\;0.1\;{\mu}m$.

Ferroelectricity of Bi-doped ZnO Films Probed by Scanning Probe Microscopy

  • Ben, Chu Van;Lee, Ju-Won;Kim, Jung-Hoon;Yang, Woo-Chul
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제42회 동계 정기 학술대회 초록집
    • /
    • pp.323-323
    • /
    • 2012
  • We present ferroelectricity of Bi-doped ZnO film probed by piezoresponse force microscopy (PFM), which is one of the Scanning Probe Microscopy techniques. Perovskite ferroelectrics are limited to integration of devices into semiconductor microcircuitry due to hard adjusting their lattice structure to the semiconductor materials. Transition metal doped ZnO film is one of the candidate materials for replacing the perovskite ferroelectrics. In this study, ferroelectric characteristics of the Bi-doped ZnO grown by pulsed laser deposition were probed by PFM. The polarization switching and patterning of the ZnO films were performed by applying DC bias voltage between the AFM tips and the films with varying voltages and polarity. The PFM contrast before and after patterning showed clearly polarization switching for a specific concentration of Bi atoms. In addition, the patterned regions with nanoscale show clearly the local piezoresponse hysteresis loop. The spontaneous polarization of the ZnO film is estimated from the local piezoresponse based on the comparison with LiNbO3 single crystals.

  • PDF

Selective detection of AC transport current distributions in GdBCO coated conductors using low temperature scanning Hall probe microscopy

  • Kim, Chan;Kim, Mu Young;Park, Hee Yeon;Ri, Hyeong-Ceoul
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제19권1호
    • /
    • pp.26-29
    • /
    • 2017
  • We studied the distribution of the current density and its magnetic-field dependence in GdBCO coated conductors with AC bias currents using low temperature scanning Hall probe microscopy. We selectively measured magnetic field profiles from AC signal obtained by Lock-in technique and calculated current distributions by inversion calculation. In order to confirm the AC measurement results, we applied DC current corresponding to RMS value of AC current and compared distribution of AC and DC transport current. We carried out the same measurements at various external DC magnetic fields, and investigated field dependence of AC current distribution. We notice that the AC current distribution unaffected by external magnetic fields and preserved their own path on the contrary to DC current.

주사형(走査型) 전자현미경(電子顯微鏡)의 응용분야(應用分野) (Applications of the Scanning Electron Microscope)

  • 김용락
    • Applied Microscopy
    • /
    • 제2권1호
    • /
    • pp.39-46
    • /
    • 1972
  • There are many kinds of microscopes suitable for general studies; optical microscopes(OM), conventional transmission electron microscopes (TEM), and scanning electron microscopes(SEM). The optical microscopes and the conventional transmission electron microscopes are very familiar. The images of these microscopes are directly formed on an image plane with one or more image forming lenses. On the other hand, the image of the scanning electron microscope is formed on a fluorescent screen of a cathode ray tube using a scanning system similar to television technique. In this paper, the features and some applications of the scanning electron microscope will be discussed briefly. The recently available scanning electron microscope, combining a resolution of about $200{\AA}$ with great depth of field, is favorable when compared to the replica technique. It avoids the problem of specimen damage and the introduction of artifacts. In addition, it permits the examination of many samples that can not be replicated, and provides a broader range of information. The scanning electron microscope has found application in diverse fields of study including biology, chemistry, materials science, semiconductor technology, and many others. In scanning electron microscopy, the secondary electron method. the backscattererd electron method, and the electromotive force method are most widely used, and the transmitted electron method will become more useful. Change-over of magnification can be easily done by controlling the scanning width of the electron probe. It is possible. to continuously vary the magnification over the range from 100 times to 1.00,000 times without readjustment of focusing. Conclusion: With the development of a scanning. electron microscope, it is now possible to observe almost all-information produced through interactions between substances and electrons in the form of image. When the probe is properly focused on the specimen, changing magnification of specimen orientation does not require any change in focus. This is quite different from the conventional transmission electron microscope. It is worthwhile to note that the typical probe currents of $10^{-10}$ to $10^{-12}\;{\AA}$ are for below the $10^{-5}$ to $10^{-7}\;{\AA}$ of a conventional. transmission microscope. This reduces specimen contamination and specimen damage due to heatings. Outstanding features of the scanning electron microscope include the 'stereoscopic observation of a bulky or fiber specimen in high resolution' and 'observation of potential distribution and electromotive force in semiconductor devices'.

  • PDF

Scanning Probe Microscopy for Biological Samples

  • Kim, Jong-Min;Chang, Sang-Mok;Muramatsu, Hiroshi
    • 한국생명과학회:학술대회논문집
    • /
    • 한국생명과학회 2005년도 국제학술심포지움 The 44th Annual Meeting of Korean Society for Life Science
    • /
    • pp.41-46
    • /
    • 2005
  • PDF