• 제목/요약/키워드: scanner

검색결과 2,048건 처리시간 0.031초

Effects of inter-implant distance on the accuracy of intraoral scanner: An in vitro study

  • Thanasrisuebwong, Prakan;Kulchotirat, Tharathip;Anunmana, Chuchai
    • The Journal of Advanced Prosthodontics
    • /
    • 제13권2호
    • /
    • pp.107-116
    • /
    • 2021
  • PURPOSE. Several studies focused on the accuracy of intra-oral scanners in implant dentistry, but the data of inter-implant distances were not widely mentioned. Therefore, this study aimed to evaluate the effect of distance between two implants on the surface distortion of scanned models generated by intra-oral scanners. MATERIALS AND METHODS. Three models with the distances between two fixed scan bodies of 7, 14, and 21 mm were fabricated and scanned with a highly precise D900L dental laboratory scanner as reference models. Fifteen scans were performed with TRIOS3 and CEREC Omnicam intra-oral scanners. Trueness, precision, and angle deviation of the test models were analyzed (α=.05). RESULTS. There was a significant difference among inter-implant distances in both intraoral scanners (P<.001). The error of trueness and precision increased with the increasing inter-implant length, while the angle deviation did not show the same trend. A significant difference in the angle deviation was found among the inter-implant distance. The greatest angle deviation was reported in the 14-mm group of both scanners (P<.05). In contrast, the lowest angle deviation in the 21-mm group of the TR scanner and the 7-mm of the CR scanner was reported (P<.001). CONCLUSION. The inter-implant distance affected the accuracy of intra-oral scanner. The error of trueness and precision increased along with the increasing distance between two implants. However, the distortions were not clinically significant. Regarding angle deviation, the clinically significant angle deviation may be possible when using intra-oral scanners in the partially edentulous arch.

Effect of the volumetric dimensions of a complete arch on the accuracy of scanners

  • Kim, Min-Kyu;Son, KeunBaDa;Yu, Beom-Young;Lee, Kyu-Bok
    • The Journal of Advanced Prosthodontics
    • /
    • 제12권6호
    • /
    • pp.361-368
    • /
    • 2020
  • PURPOSE. The present study aimed to evaluate the accuracy of a desktop scanner and intraoral scanners based on the volumetric dimensions of a complete arch. MATERIALS AND METHODS. Seven reference models were fabricated based on the volumetric dimensions of complete arch (70%, 80%, 90%, 100%, 110%, 120%, and 130%). The reference models were digitized using an industrial scanner (Solutionix C500; MEDIT) for the fabrication of a computer-aided design (CAD) reference model (CRM). The reference models were digitized using three intraoral scanners (CS3600, Trios3, and i500) and one desktop scanner (E1) to fabricate a CAD test model (CTM). CRM and CTM were then superimposed using inspection software, and 3D analysis was conducted. For statistical analysis, one-way analysis of variance was used to verify the difference in accuracy based on the volumetric dimensions of the complete arch and the accuracy based on the scanners, and the differences among the groups were analyzed using the Tukey HSD test as a post-hoc test (α=.05). RESULTS. The three different scanners showed a significant difference in accuracy based on the volumetric dimensions of the complete arch (P<.05), but the desktop scanner did not show a significant difference in accuracy based on the volumetric dimensions of the complete arch (P=.808). CONCLUSION. The accuracy of the intraoral scanners was dependent on the volumetric dimensions of the complete arch, but the volumetric dimensions of the complete arch had no effect on the accuracy of the desktop scanner. Additionally, depending on the type of intraoral scanners, the accuracy differed according to the volumetric dimensions of the complete arch.

PET/CT 장치의 감마선 검출과정 (Gamma Ray Detection Processing in PET/CT scanner)

  • 박성옥;안성민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제29권3호
    • /
    • pp.125-132
    • /
    • 2006
  • SPECT camera와 PET scanner 그리고 PET/CT 장치는 감마선을 검출하여 얻어진 자료(data)를 정보화 한다. 특히 PET/CT 장치는 PET영상에서 나타나는 해부학적 불선예함을 CT로 보완하여 선예한 해부학적 구조의 영상 묘출능력이 뛰어나 양질의 진단정보를 제공하고 있게 되었다. 신속 정확한 자료의 획득과 정보화를 위하여 우선적으로 검출기(detector)에서의 효율적인 감마선검출은 매우 예민하고 중요한 역할 중의 하나이다. 섬광체(scintillator)의 개발과 함께 data 처리를 위한 software의 발전은 영상재구성처리시간의 단축은 물론 영상의 질적인 향상을 초래하였다. PET scanner에서는 SPECT camera의 $100{\sim}200\;keV$와는 달리 511 keV의 고에너지 감마선을 검출한다. 섬광체 GSO, LSO는 PET scanner의 섬광체로 비교적 많이 이용되고 있다. 고에너지 감마선에너지를 빛으로 전환하여 여러 단계를 거쳐 정보화하는 과정은 결과적으로 고화질의 영상을 비롯한 정확하고 신속한 진단정보획득에 목적을 두고 있다. 화질의 질적향상은 획득한 정보량에 대한 영상의 재구성 방법과 기술에 따라 영향을 받는다. 본 연구는 PET/CT 장치에서 특히 PET부분에서 섬광체(scintillator)의 특성과 감마선의 검출과정에서부터 영상 재구성단계까지 문헌적 고찰을 통하여 요약 설명하였다.

  • PDF

표면파를 이용한 자동 초음파탐상검사 주사장치의 위치제어 기술 (Position Control Technique of Ultrasonic Scanner for an Automated Ultrasonic Testing Using Surface Wave)

  • 이종포;박철훈;엄병국
    • 비파괴검사학회지
    • /
    • 제23권1호
    • /
    • pp.30-37
    • /
    • 2003
  • 수동 초음파검사를 자동검사로 대체하기 위해서는 탐촉자의 위치정보를 정확하게 제어할 수 있는 주사장치가 필수적이다. 위치정보를 알기 위하여 기존의 모터제어 주사장치에서는 엔코더를 사용하고 있으며 엔코더는 여러 가지 측면에서 많은 장점을 가지고 있으나 주사 중에 미끄러짐(slip)이 발생하면 엔코더 위치정보의 정확도에 많은 오차가 포함되게 된다. 따라서, 미끄러짐이 있는 경우의 위치정보는 무의미하게 되며, 자동초음파검사의 신뢰도는 큰 문제가 된다. 그러므로 미끄러짐을 피해야 하나 현재는 이를 완전히 해결하는 방법은 없는 상태이다. 본 논문에서는 이와 같은 문제점을 해결하고 엔코더를 대체할 수 있는 새로운 개념의 초음파검사 자동 주사장치의 위치 제어기술을 제안하고 이 방법이 실제 사용 가능함을 확인하였다 즉, 주사하고자 하는 직선 영역에 송신용 표면파 탐촉자를 부착하고 주사장치에 부착된 수신용 탐촉자에서 표면파를 수신하여 현재의 주사장치의 위치를 계산하고 이를 바탕으로 주사하고자 하는 거리만큼의 주사장치의 이동을 제어할 수 있다.

3D Laser Scanner를 이용한 대규모 불연속면의 굴곡도 측정 연구 (A study on Waviness of Large Discontinuity using 3D Laser Scanner)

  • 김용;이수곤;김치환
    • 지질공학
    • /
    • 제27권2호
    • /
    • pp.119-124
    • /
    • 2017
  • 대규모 불연속면의 굴곡도는 암반의 안정성을 판단하는 중요한 요소 중 하나이다. 그러나, 주로 실시하는 불연속면의 굴곡도 측정시험은 대형암반의 작은 코어를 채취하여 채취한 작은 코어의 굴곡도에 계수를 사용하여 대형 암반의 굴곡도를 환산하고 있다. 이러한 점을 보완하고자 3D Laser Scanner를 사용하여 대규모 불연속면의 굴곡도를 직접 측정하는 방안에 대해 연구를 수행하였다. 본 연구에서는 3D Laser Scanner를 이용하여 실제 X,Y,Z의 좌표를 가지는 3D 모델을 구축하였고, CAD 프로그램을 사용하여 대규모 불연속면의 굴곡도를 산정한 데이터와 현장에서 Disc-Clinometer로 측정한 Data 결과를 비교 분석 하였다. 그 결과 Mean Dip과 Mean I 측정결과 모두 $1^{\circ}$ 이내로서 측정 장비의 기계오차 $1{\sim}2^{\circ}$ 사이에 속 하기 때문에 3D Laser Scanner를 이용한 데이터 취득 및 분석은 기존의 조사법을 보완할 수 있는 효율적이고 신뢰성 있는 조사법이라고 분석되었다.