• Title/Summary/Keyword: scan time

Search Result 1,248, Processing Time 0.025 seconds

Usefulness of the Salivagram for the Diagnosis of Brain Lesions in Patients with Aspiration Pneumonia (뇌병변 환자에서 흡인성 폐렴 진단을 위한 Salivagram의 유용성)

  • Oh, Shin Hyun;Choi, Yung Sook;Ro, Dong Wook;Nam-Koong, Hyuk;Kim, Jae Sam;Leee, Chang Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.1
    • /
    • pp.48-52
    • /
    • 2013
  • Purpose: Bed, living a long time is required in adult patients with brain lesions such as stroke, traumatic brain injury, and Parkinson's disease, causing pneumonia and respiratory diseases may be due to aspiration of food or saliva. In patients with recurrent pneumonia or pulmonary symptoms, there is a need to determine the possibility of pulmonary aspiration due to aspiration of saliva. Materials and Methods: Saliva due to aspiration pneumonia diagnosis in patients with brain lesions request for inspection to the Department of Nuclear Medicine, 10 patients (male 6, female 4) were included in this study. Patients were fasted before the test, $^{99m}Tc_{O4}$ 185 MBq (5 mCi) of less than 1 mL of solution was administered in the oral cavity. Administration and 20 minutes of dynamic imaging acquisition, and immediately after that the static images were acquired. Delayed scan after 2-4 hours if necessary. Results: Positivity rate of all 10 patients was 60%. In 4 patients showed positive reactions after the administration of oral cavity in a 20-minute dynamic imaging were able to confirm whether the aspiration. In the remaining 2 patients, four hours of additional delay tests were able to confirm whether the aspiration. Conclusion: Does not require changes in patient posture compared to the other checks that can be diagnosed with aspiration pneumonia. A simple test and takes less time. Therefore be useful in providing information for the diagnosis and treatment modality.

  • PDF

Quantitative Comparisons in $^{18}F$-FDG PET Images: PET/MR VS PET/CT ($^{18}F$-FDG PET 영상의 정량적 비교: PET/MR VS PET/CT)

  • Lee, Moo Seok;Im, Young Hyun;Kim, Jae Hwan;Choe, Gyu O
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.68-80
    • /
    • 2012
  • Purpose : More recently, combined PET/MR scanners have been developed in which the MR data can be used for both anatometabolic image formation and attenuation correction of the PET data. For quantitative PET information, correction of tissue photon attenuation is mandatory. The attenuation map is obtained from the CT scan in the PET/CT. In the case of PET/MR, the attenuation map can be calculated from the MR image. The purpose of this study was to assess the quantitative differences between MR-based and CT-based attenuation corrected PET images. Materials and Methods : Using the uniform cylinder phantom of distilled water which has 199.8 MBq of $^{18}F$-FDG put into the phantom, we studied the effect of MR-based and CT-based attenuation corrected PET images, of the PET-CT using time of flight (TOF) and non-TOF iterative reconstruction. The images were acquired from 60 minutes at 15-minute intervals. Region of interests were drawn over 70% from the center of the image, and the Scanners' analysis software tools calculated both maximum and mean SUV. These data were analyzed by one way-anova test and Bland-Altman analysis. MR images are segmented into three classes(not including bone), and each class is assigned to each region based on the expected average attenuation of each region. For clinical diagnostic purpose, PET/MR and PET/CT images were acquired in 23 patients (Ingenuity TF PET/MR, Gemini TF64). PET/CT scans were performed approximately 33.8 minutes after the beginnig of the PET/MR scans. Region of interests were drawn over 9 regions of interest(lung, liver, spleen, bone), and the Scanners' analysis software tools calculated both maximum and mean SUV. The SUVs from 9 regions of interest in MR-based PET images and in CT-based PET images were compared. These data were analyzed by paired t test and Bland-Altman analysis. Results : In phantom study, MR-based attenuation corrected PET images generally showed slightly lower -0.36~-0.15 SUVs than CT-based attenuation corrected PET images (p<0.05). In clinical study, MR-based attenuation corrected PET images generally showed slightly lower SUVs than CT-based attenuation corrected PET images (excepting left middle lung and transverse Lumbar) (p<0.05). And percent differences were -8.01.79% lower for the PET/MR images than for the PET/CT images. (excepting lung) Based on the Bland-Altman method, the agreement between the two methods was considered good. Conclusion : PET/MR confirms generally lower SUVs than PET/CT. But, there were no difference in the clinical interpretations made by the quantitative comparisons with both type of attenuation map.

  • PDF

Production and Assessing Usefulness of the Moving Phantom for Respiration Gated Radiotherapy (호흡동조 방사선치료용 팬텀의 제작 및 유용성 평가)

  • Lee, Yang-Hoon;Lee, Jae-Hee;Yoo, Suk-Hyun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.2
    • /
    • pp.135-144
    • /
    • 2010
  • Purpose: The purpose of this study is that through production of phantom for respiration gated radiotherapy, assessing appropriacy of exposure dose for the therapy using RPM (Real-time Position Management). Materials and Methods: We located measurement object on the phantom for respiration gated radiotherapy made of 2 linear actuator, acrylic panel, stanchion, iron plate ets. to drive (up, down, front, back). Using 4D CT scan, we analyzed patient's respiration and reproduced the movement by computer. On the phantom, we located a 2D-Array (PTW) and an White water phantom (4.5 cm) and used DMLC (interval 2 cm) in the field size $10{\times}10\;cm$, then exposed 21EX X-ray 100 MU, in the case of phantom was (1) static (2) moving (3) gated using RPM respectively gantry $0^{\circ}$ and $90^{\circ}$ We measured with a 0.125 CC ionization chamber (PTW) on the phantom (7.5 cm) in the same condition. Results: Ionization chamber: There were within 0.3% of error with gating respiration and approximately 2% of error without gating in the same condition. 2D-Array: Gantry $90^{\circ}$, field size $10{\times}10\;cm$, using DMLC. There were within 3% of error with gating respiration and approximately 16% of error without gating. Conclusion: The phantom for respiration gated radiotherapy makes plans considering patient's movement, quantitative analysis of exposure dose and proper assessment therapy for IMRT patients using RPM possible.

  • PDF

The Measurement of $^{99m}Tc-DTPA$ Pulmonary Clearance in Normals, Asymptomatic Smokers and Diabetic Patients (정상 성인, 무증상 흡연자, 당뇨병 환자에서 $^{99m}Tc-DTPA$ 폐제거율의 측정)

  • Kim, In-Ju;Kim, Seong-Jang;Kim, Yong-Ki;Kim, Yun-Seong;Lee, Min-Ki;Park, Soon-Kew
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.3
    • /
    • pp.266-275
    • /
    • 1998
  • Purpose: We measured pulmonary epithelial permeability by $^{99m}Tc-DTPA$ radioaerosol clearance in patients with diabetes and correlated with the presence of microangiopathy to understand the pathophysiology of pulmonary microangiopathy and evaluate $^{99m}Tc-DTPA$ radioaerosol clearance as a diagnostic test to assess pulmonary microangiopathy. Materials and Methods: We performed $^{99m}Tc-DTPA$ radioaerosol scan in 10 normal subjects, 10 asymptomatic smokers, 20 diabetic patients without history of smoking (10 with microangiopathy, 10 without microangiopathy). $^{99m}Tc-DTPA$ clearance half-time ($T_{1/2}$) was calculated, then compared with the result of chest radiography and pulmonary function test. Results: Chest radiography and pulmonary function test were normal in all subjects. There were no significant difference of clinical or laboratory characteristics between these groups except age. The diabetic patients with microangiopathy were significantly older (p<0.05). The $T_{1/2}$ of normal subjects and asymptomatic smokers were significantly different ($65.2{\pm}23.7min$ vs $39.6{\pm}9.8min$, p<0.05). For diabetic patients with microangiopathy, the $T_{1/2}$ was $90.5{\pm}46.5min$ and significantly delayed when compared with those of normals and asymptomatic smokers (p<0.05). However, the $T_{1/2}$ of diabetic patients without microangiopathy, $70.0{\pm}12.7min$, was not significantly different from those of normals or asymptomatic smokers (p>0.05). No significant correlation was found between the $T_{1/2}$ and spirometric parameters including DLco, FVC, $FEV_1,\;FEV_1/FVC$ (%) and $FEF_{25-75%}$ in all subjects, and between the $T_{1/2}$ and duration of diabetes ;in diabetic patients. Conclusion: Eventhough the influence of age can't be excluded, delayed $^{99m}Tc-DTPA$ clearance half-time ($T_{1/2}$) in diabetic patients with microangiopathy indicates decreased pulmonary capillary permeability as one of the pathophysiologic results of pulmonary microangiopaththy. Further studies are needed in larger number of age matched control and diabetic patients to evaluate the diagnostic efficacy.

  • PDF

Assessment and Comparison of SUVs of Three Different PET/CT Scanners (장비에 따른 SUV의 차이와 이에 관한 고찰)

  • Kim, Tae-Yeob;Lim, Jung-Jin;Lee, Hong-Jae;Kim, Hyun-Joo;Kim, Joong-Hyun;Lee, Jae-Sung
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.34-38
    • /
    • 2011
  • Purpose: The SUV is a widely used semi-quantitative index in PET for the estimation of radio-tracer accumulation in VOI. In this study, SUVs from three different PET/CT scanners were assessed, and differences between SUVs were evaluated. Materials and Methods: The PET/CT scanners which were assessed in this study were GEMINI, GEMINI TF 64 (Philips) and Biograph True Point True V 40 (Siemens). The NEMA PET phantom (Data Spectrum Corp., USA) was used to evaluate SUVs. The NEMA PET phantom has6.8 kg weight and three hot inserts. Two different activity distributions for the background and inserts were tested. The activity ratio were 3.7:3.7:7.4:11.1 MBq (1:1:2:3) and 1.85:7.4:9.25:11.1MBq (1:4:5:6) for each of background, insert 1, insert 2 and insert 3. Acquisition time was 2 minutes per bed position and NEMA PET phantom could be covered by two bed positions for all PET/CT scanners. The SUVs from each PET/CT scanner were compared with calculated true value. Results: For both activity ratios, all scanners showed similar results. The differences between each scanner were insignificant. Each scanner showed 91.2%, 85.9% and 87.2% of true SUV for GEMINI, GEMINI TF 64, Biograph True Point TrueV, respectively. Conclusion: For all scanners, SUVs were slightly lower than true value. However, the difference between scanners was insignificant. The SUVs from these scanners would be clinically meaningful if their consistent underestimation is kept in mind.

  • PDF

Interstitial Vaginal Needle Implantation in Gynecological Tumors : Design and Construction of Applicator (부인과암에서 조직내 삽입 방사선치료 - Applicator의 고안 및 제작-)

  • Kang, Seung-Hee;Chun, Mi-Son;Kang, Hae-Jin;Jung, Chil;Son, Jeong-Hyae
    • Radiation Oncology Journal
    • /
    • v.16 no.2
    • /
    • pp.167-175
    • /
    • 1998
  • Purpose : It is not a simple task to achieve the ideal isodose curve with a standard vaginal applicator or sing1e plane needle impant in the paravaginal tissue when primary or recurrent gynecological neoplasms(cervical cancers, vaginal cancers and vulvar cancers) are treated as a boost following external beam radiotherapy. The authors introduce the development and construction of a simple, inexpensive, customized applicator for volume implant to maximize the radiation dose to the tumor while minimizing the dose to the rectum and the bladder. Materials and Methods : Nine patients underwent Ir-192 transperineal interstitial implantation for either recurrent(5 cases) or primary(3 cases) cervical cancers or primary vaginal cancer(1 case) between August 1994 and February 1998 at Ajou university hospital. First 3 cases were performed with a sing1e plane implant guided by digital palpation. Because of inadequate isodose coverage in the tumor volume in first 3 cases, we designed and constructed interstitial vaginal applicator for volume implant to improve tumor dose distribution and homogeneity while sparing the surrounding normal tissue. Our applicators consist of vaginal obturator and perineal template that made of the clear acrylamide and dental mold material$(Provil^{(R)})$. The applicators were customized individually according to the tumor size and its location Both HDR and LDR irradiation were given with these applicators accomodating 6 Fr needles(Microselectron Nucletron). The pretreatment planning prior to actual implant was performed whenever possible. Results : Needles can be inserted easily and evenly into the tumor volume through the holes of templates, requiring less efforts and time for the implant procedure. Our applicators made of materials available from commercial vendors. These have an advantage that require easy procedure, and spend relatively short time to construct. Also it was possible to fabricate applicators to individualize according to the tumor size and its location and to achieve the ideal isodose coverage. We found an accurate needle arrangement and ideal dose distribution through the CT scan that was obtained in 3 cases after needle implant. Three patients with primary cervical and vaginal cancers were controlled locally at final follow up. But all recurrent cases failed to do so. Conclusion : The authors introduce inexpensive, simple interstitial vaginal templates which were self-designed and constructed using materials available from commercial vendors such as acrylanide and dental mold material $(Provil^{(R)})$.

  • PDF

Acute Cerebral Infarction in a Rabbit Model: Perfusion and Diffusion MR Imaging (가토의 급성 뇌경색에서 관류 및 확산강조 자기공명영상)

  • Heo Suk-Hee;Yim Nam-Yeol;Jeong Gwang-Woo;Yoon Woong;Kim Yun-Hyeon;Jeong Young-Yeon;Chung Tae-Woong;Kim Jeong;Park Jin-Gyoon;Kang Heoung-Keun;Seo Jeong-Jin
    • Investigative Magnetic Resonance Imaging
    • /
    • v.7 no.2
    • /
    • pp.116-123
    • /
    • 2003
  • Purpose : The present study was undertaken to evaluate the usefulness of cerebral diffusion (DWI) and perfusion MR imaging (PWI) in rabbit models with hyperacute cerebral ischemic infarction. Materials and Methods : Experimental cerebral infarction were induced by direct injection of mixture of Histoacryl glue, lipiodol, and tungsten powder into the internal cerebral artery of 6 New-Zealand white rabbits, and they underwent conventional T1 and T2 weighted MR imaging, DWI, and PWI within 1 hour after the occlusion of internal cerebral artery. The PWI scan for each rabbit was obtained at the level of lateral ventricle and 1cm cranial to the basal ganglia. By postprocessing using special imaging software, perfusion images including cerebral blood volume (CBV), cerebral blood flow (CBF), and mean transit time (MTT) maps were obtained. The detection of infarcted lesion were evaluated on both perfusion maps and DWI. MTT difference time were measured in the perfusion defect lesion and symmetric contralateral normal cerebral hemisphere. Results : In all rabbits, there was no abnormal signal intensity on T2WI. But on DWI, abnormal high signal intensity, suggesting cerebral infarction, were detected in all rabbits. PWI (rCBV, CBF and MTT map) also showed perfusion defect in all rabbits. In four rabbits, the calculated square of perfusion defect in MTT map is larger than that of CBF map and in two rabbits, the calculated size of perfusion defect in MTT map and CBF map is same. Any rabbits do not show larger perfusion defect on CBF map than MTT map. In comparison between CBF map and DWI, 3 rabbits show larger square of lesion on CBF map than on DWI. The others shows same square of lesion on both technique. The size of lesion shown in 6 MTT map were larger than DWI. In three cases, the size of lesion shown in CBF map is equal to DWI. But these were smaller than MTT map. The calculated square of lesion in CBF map, equal to that of DWI and smaller than MTT map was three. And in one case, the calculated square of perfusion defect in MTT map was largest, and that of DWI was smallest. Conclusion : DWI and PWI may be useful in diagnosing hyperacute cerebral ischemic infarction and in e-valuating the cerebral hemodynamics in the rabbits.

  • PDF

Locally Advanced, Unresectable Pancreatic Cancer Treated by Stereotactic Radiation Therapy (국소적으로 진행된, 절제 불가능한 췌장암에서 정위 방사선 치료)

  • Choi Chul-Won;Kim Mi-Sook;Cho Chul-Koo;Yoo Seong-Yul;Yang Kwang-Mo;Yoo Hyung-Jun;Lee Dong-Han;Ji Young-Hoon;Han Chul-Ju;Kim Jin;Kim Young-Han
    • Radiation Oncology Journal
    • /
    • v.24 no.1
    • /
    • pp.11-20
    • /
    • 2006
  • Puroose: In order to find out whether stereotactic radiation therapy (RT) using CyberKnife (CK) could improve survival rate and lower acute toxicity compared to conventional RT. Materials and Methods: From April 2003 through April 2004, 19 patients with Eastern Cooperative Oncology Group (ECOG) performance status ${\leq}3$ and locally advanced pancreas cancer without distant metastasis, evaluated by CT or PET/CT, were included. We administered stereotactic RT consisting of either 33 Gy, 36 Gy or 39 Gy in 3 fractions to 6, 4 and 9 patients, respectively, in an effort to increase the radiation dose step by step, and analyzed the survival rate and gastrointestinal toxicities by the acute radiation morbidity criteria of Radiation Therapeutic Oncology Group (RTOG). Prognostic factors of age, sex, ECOG performance score, chemotherapy, bypass surgery, radiation dose, CA 19-9, planning target volume (PTV), and adjacent organ and vessel invasion on CT scan were evaluated by Log Rank test. Results: The median survival time was 11 months with 1-year survival rate of 36.8%. During follow-up period (range $3{\sim}20$ months, median 10 months), no significant gastrointestinal acute toxicity (RTOG grade 3) was observed. In univariate analysis, age, sex, ECOG performance score, chemotherapy, bypass surgery, radiation dose, CA 19-9 level, and adjacent organ and vessel invasion did not show any significant changes of survival rate, however, patients with PTV (80 cc showed more favorable survival rate than those with PTV>80 cc (p-value<0.05). In multivariate analysis, age younger than 65 years and PTV>80 cc showed better survival rate. Conclusion: In terms of survival, the efficacy of stereotactic radiation therapy using CK was found to be superior or similar to other recent studies achieved with conventional RT with intensive chemotherapy, high dose conformal RT, intraoperative RT (IORT), or intensity modulated RT (IMRT). Furthermore, severe toxicity was not observed. Short treatment time in relation to the short life expectancy gave patients more convenience and, finally, quality of life would be increased. Consequently, this could be regarded as an effective novel treatment modality for locally advanced, unresectable pancreas cancer. PTV would be a helpful prognostic factor for CK.

Biodistribution of $^{99m}Tc$-Lactosylated Serum Albumin in Mice with Diethylnitrosamine or Thiacetamide Induced Liver Injury (Diethylnitrosamine 및 Thioacetamide 유발 간손상 생쥐에서의 $^{99m}Tc$-Lactosylated Serum Albumin의 체내 분포상)

  • Whang, Jae-Seok;Ahn, Byeong-Cheol;Sung, Young-Ok;Seo, Ji-Hyoung;Bae, Jin-Ho;Jeong, Shin-Young;Yoo, Jung-Soo;Jeong, Jae-Min;Lee, Jae-Tae;Lee, Kyu-Bo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.3
    • /
    • pp.200-208
    • /
    • 2005
  • Purpose: Tc-99m labeled diethylenetriaminepentaacctic acid (DTPA)-coupled galactosylated human serum albumin (GSA) is a currently used imaging agent for asialoglycoprotein receptor (ASGPR) of the liver, but, it has several shortcomings. Recently a new ASGPR imaging agent, $^{99m}Tc$-lactosylated human serum albumin (LSA), with simple labeling procedure, high labeling efficiency, high stability was developed. In order to assess the feasibility of the $^{99m}Tc$-LSA as a ASGPR imaging radiopharmaceuticals, we performed biodistribution study of the tracer in liver injured mice model and the results were compared with histolgic data. Materals and Methods: To induce hepatic damage in ICR mice, diethylnitrosamine (DEN) ($60mg/kg/week{\times}5time$, low dose or $180mg/kg/week{\times}2times$, high dose) and thioacetamide (TAA) ($50mg/kg{\times}1time$) were administrated intraperitoneally. Degree of liver damage was evaluated by tissue hematoxilin-eosin stain, and expression of asialoglycoprotein receptor (ASGPR) was assessed by immunohistochemistry using ASGPR antibody. $^{99m}Tc$-LSA was intravenously administrated via tail vein in DEN or TAA treated mice, and biodistribution study of the tracer was also performed. Results: DEN treated mice showed ballooning of hepatocyte and inflammatory cell infiltration in low dose group and severe hapatocyte necrosis in high dose group, and low dose group showed higher ASGPR staining than control mice in immunohistochemical staining. TAA treated mice showed severe hepatic necrosis. $^{99m}Tc$-LSA Biodistribution study showed that mice with hepatic necrosis induced by high dose DEN or TAA revealed higher blood activity and lower liver activity than control mice, due to slow clearance of the tracer by the liver. The degree of liver uptake was inversely correlated with the degree of histologic liver damage. But low dose DEN treated mice with mild hepatic injury showed normal blood clearance and hepatic activity, partly due to overexpression of ASGPR in mice with mild degree hepatic injury. Conclusion: Liver uptake of $^{99m}Tc$-LSA was inversely correlated with degree of histologic hepatic injury in DEN and TAA treated mice. These results support that $^{99m}Tc$-LSA can be used to evaluate the liver status in liver disease patients.

Comparison of mDixon, T2 TSE, and T2 SPIR Images in Magnetic Resonance Imaging of Lumbar Sagittal Plane (요추 시상면 자기공명 영상검사에서 mDixon과 T2 TSE, T2 SPIR 영상의 비교 연구)

  • Jung, Da-Bin;Lee, Hae-Kag;Heo, Yeong-Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.6
    • /
    • pp.927-933
    • /
    • 2021
  • The purpose of this study was to compare and analyze the differences in scan time, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) in the third lumbar vertebral region including the back fat, spinal cord, and cerebrospinal fluid using the mDixon, T2 TSE, and T2 spectral pre-saturation with inversion-recovery (SPIR) techniques. With the factors affecting the SNR fixed, the lumbar sagittal plane images of 30 adults were compared on mDixon, T2 TSE, and T2 SPIR imaging tests. The test times for mDixon, T2 TSE, and T2 SPIR were 115 seconds, 60 seconds, and 60 seconds, respectively. The mDixon T2 images showed higher SNR than the T2 TSE images at the third lumbar vertebral region (p<0.05), lower SNR in the back fat and cerebrospinal fluid (p<0.05) areas, and comparable SNR in the spinal cord (p>0.05). The CNR between the third lumbar vertebral area and back fat was higher in the mDixon T2 images, and the CNR of the cerebrospinal fluid and spinal cord images was higher in the T2 TSE images (p<0.05). The mDixon T2 FS images CNR was lower for the 3rd lumbar vertebral body region and back fat than the T2 SPIR images, and higher for the spinal cord and cerebrospinal fluid images (p<0.05). The CNR between the third lumbar body and back fat areas was higher in the mDixon T2 FS images (p<0.05), and there was no difference in the CNR in the images of the cerebrospinal fluid and the spinal cord (p>0.05). It is difficult to determine whether the mDixon technique is superior to the conventional T2 TSE and T2 SPIR techniques in terms of test time, SNR, and CNR. This study was confined to patients with simple lower back pain and was limited by controlled experimental conditions. Studies using clinically applied protocols are warranted in the future.