• Title/Summary/Keyword: scalloping effect

Search Result 4, Processing Time 0.022 seconds

SPACEBORNE TOPS SAR SYSTEM MODELING AND PERFORMANCE ANALYSIS (TOPS 위성 SAR 모드 시스템 구현 및 성능 평가 연구)

  • Kang, Seo-Li;Song, Jeong-Hwan;Kim, Bum-Seung;Kim, Hyeon-Cheol;Lee, Woo-Kyung
    • Journal of Satellite, Information and Communications
    • /
    • v.9 no.2
    • /
    • pp.74-79
    • /
    • 2014
  • Conventional ScanSAR mode has been adopted in Envisat or Radarsat and played an important role to acquire wide swath SAR images for environmental surveillance. However, it suffers from the undesirable scalloping effect caused by non-homogeneity of antenna pattern while the image resolution is sacrificed. In recent years, TOPS mode has been suggested and put into use to overcome the disadvantages of the conventional scanning mode. Although TOPS mode is able to produce wide-swath SAR image in a short time interval, it demands highly complicated system design knowledge. In this paper, we present the operation principle of TOPS mode and a full SAR simulation is performed to generate TOPS SAR raw data. Azimuth antenna pattern is modified during TOPS mode operation and it is shown that the undesired scalloping effect is suppressed in the generated SAR image.

A Study on the Radiometric Correction of Sentinel-1 HV Data for Arctic Sea Ice Detection (북극해 해빙 탐지를 위한 Sentinel-1 HV자료의 방사보정 연구)

  • Kim, Yunjee;Kim, Duk-jin;Kwon, Ui-Jin;Kim, Hyun-Cheol
    • Korean Journal of Remote Sensing
    • /
    • v.34 no.6_2
    • /
    • pp.1273-1282
    • /
    • 2018
  • Recently, active research on the Arctic Ocean has been conducted due to the influence of global warming and new Arctic ship route. Although previous studies already calculated quantitative extent of sea ice using passive microwave radiometers, melting at the edge of sea ice and surface roughness were hardly considered due to low spatial resolution. Since Sentienl-1A/B data in Extended Wide (EW) mode are being distributed as free of charge and bulk data for Arctic sea can be generated during a short period, the entire Arctic sea ice data can be covered in high spatial resolution by mosaicking bulk data. However, Sentinel-1A/B data in EW mode, especially in HV polarization, needs significant radiometric correction for further classification. Thus, in this study, we developed algorithms that can correct thermal noise and scalloping effects, and confirmed that Arctic sea ice and open-water were well classified using the corrected dual-polarization SAR data.

Multifocal intraosseous calvarial hemangioma misdiagnosed as subgaleal lipoma

  • Kim, Joo-Hak;Ahn, Chang Hwan;Kim, Kyung-Hee;Oh, Sang-Ha
    • Archives of Craniofacial Surgery
    • /
    • v.20 no.3
    • /
    • pp.181-185
    • /
    • 2019
  • Intraosseous hemangioma is a rare, slow-growing, benign tumor of blood vessels. Primary hemangioma of the skull is a benign lesion that may appear as a palpable mass or accidentally detected during image evaluation. Simple radiography is the most commonly used technique to localize a lesion and computed tomography (CT) may help determine the effect of a lesion. We report a case of multifocal intraosseous calvarial hemangioma developed in the subgaleal plane of an elderly male patient. Ultrasonography examination revealed hyperechoic striated septae parallel to the skin and discontinuity of the focal cortex, however, the underlying bone cortex appeared relatively intact. No significant flow is observed on Doppler ultrasonography. Based on these evaluations, the mass was interpreted by a radiologist as a subgaleal lipoma. This case highlights the importance of additional CT examination in a patient presenting with a scalloping sign of the underlying calvarium. Clinicians also should be aware of the possibility of intraosseous calvarial hemangiomas in lesion. Furthermore, the proper choice of congenital vascular malformation term is still quite confusing with misconception present in the literature.

Dosimetric Characteristics on Penumbra Regions of the Multileaf Collimator as Compared with the Lead Alloy Block (다엽 콜리메이터(Multileaf Collimator)와 합금납 차폐물(Lead Alloy Block)의 반 그림자영역의 선량 분포상의 특성 비교)

  • Lee Sang Wook;Oh Young Tack;Kim Woo Cheol;Keum Ki Chang;Yoon Seong Ick;Kim Hyun Soo;Park Won;Chu Seong Sil;Kim Gwi Eon
    • Radiation Oncology Journal
    • /
    • v.13 no.4
    • /
    • pp.391-396
    • /
    • 1995
  • Purpose : The Conformal Radiation Therapy has bee widely used under favour of development of computer technologies. The delivery of a large number of static radiation fields are being necessary for the conformal irradiation. In this paper we investigate dosimetric characteristics on penumbra regions of a multileaf collimator(MLC), and compare to those of lead alloy block for the optimal use of the system in 3-D conformal radiotherapy. Materials and Methods : The measurement of penumbra by MLC or lead alloy block was performed with 6 or 10 MV X-rays. The film was positioned at a dmax depth and 10 cm depth, and its optical density was determined using a scanning videodensitometer. The effective penumbra, the distance from $80{\%}$ to $20{\%}$ isodose lines and $90{\%}$ to $10{\%}$ were analyzed as a function of the angle between the direction of leaf motion and the edge defined by leaves. Results : Increasing MLC angle ($0-75^{\circ}$) was observed with increasing the penumbra widths and the scalloping effect. There was no definite differences of penumbra width from $80{\%}$ to $20{\%}$ isodose lines, while being the small increase of penumbra width from $90{\%}$ to $10{\%}$ isodose line varing the depth and energy. The effective penumbra width of lead alloy block are agree resonably with those of MLC within 4.8mm. Conclusion : The comparative qualitative study of the penumbra between MLC and lead alloy block demonstrate the clinical acceptability and suitability of the multileaf collimator for 3-D conformal radiotherapy.

  • PDF