• 제목/요약/키워드: scaled test

검색결과 699건 처리시간 0.027초

간이 잔향실의 음향성능 (Acoustic Performance of a Scaled Reverberation Chamber)

  • 강현주;김봉기;김재승
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계 학술대회논문집(수송기계편)
    • /
    • pp.101-104
    • /
    • 2005
  • This study presents experimental results from the performance test of a scaled reverberation chamber for measurement of sound insulation of panels. Experimental investigations were conducted in various parameters such as tunneling effect source locations, and maximum sound transmission loss. It is evident that the tunneling effect which means the variation with specimen location on the test frame gives rise to more than 3 dB deviation. One of the objective of this study that compares measured results between a real reverberation chamber and a simplified test apparatus, by using a specimen of a sandwich panel. It shows qualitatively resonable agreement from which one can find a potential to provide a design tool.

  • PDF

폭원의 축소율 산정과 축소모형 실험에의 적용 (Scale Factor of Explosives and Application on Scaled Model Test of Demolition Blasting)

  • 정도영;양형식
    • 화약ㆍ발파
    • /
    • 제22권4호
    • /
    • pp.1-6
    • /
    • 2004
  • 본 연구에서는 발파해체에 대한 축소모형실험의 폭원에 대한 차원과 축소율을 산정하고, 이로부터 축소모형실험의 적정 길이의 축소율을 고찰하였다. 그 결과 길이 축소비를 1/4로 할 때 축원의 축소율은 1/256로 모형실험과 실제 구조물에서 사용한 화약량의 비로 구한 축소율과 유사한 값을 보였다. 길이 축소율은 1/4 이상으로 하는 것이 바람직하다고 판단된다

축소모형실험을 통한 지하철 병설터널의 안정성평가 사례연구 (Case study for Stability Estimation of Subway Twin Tunnels Using Scaled Model Tests)

  • 김종우
    • 터널과지하공간
    • /
    • 제29권6호
    • /
    • pp.425-438
    • /
    • 2019
  • 본 연구에서는 일정한 방향의 층리가 발달한 퇴적암에 굴착된 지하철 병설터널을 모델링하여 축소모형 실험을 실시하였다. 연구대상 터널의 규격은 6.2 m×6.8 m이고 필러 폭은 4 m이다. 차원해석을 통해 현장암석에 적합한 모형재료를 선정하였고, 이를 사용하여 이방성 모형시험체를 제작하였으며 이축압축시험을 통해 터널의 파괴 및 변형거동을 알아보았다. 모형시험체에 하중을 증가시킴에 따라 필러의 중앙부에서 병설터널 사이를 가로지르는 최초의 균열이 발생하였고, 터널 천정부와 바닥부에서도 점차 파괴가 진행되었다. 필러부의 모든 균열은 기존의 층리면을 따라 발생하여 암반의 층리면이 필러 파괴의 주요 원인으로 나타났다. 또한, FLAC의 유비쿼터스 절리모델을 사용하여 실험 조건에 대한 수치해석을 실시함으로써 실험의 결과를 검증해 보았다. 여기서 얻어진 소성영역의 분포경향은 모형실험의 결과와 대체로 부합하여 실험의 신뢰성을 확인하였다.

소형탈선시뮬레이터 상에서의 1/5 축소대차의 안정성 해석 (A Running Stability Test of 1/5 Scaled Bogie using Small Scale Derailment Simulator)

  • 엄범규;이세용;이영엽;강부병;이희성
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.1905-1913
    • /
    • 2011
  • The dynamic characteristic of bogie that is driving system of railway vehicle is very important regarding decision of vehicle characteristics as running safety and comport. The dynamic characteristic test of bogie is tested on full size in place on field testing on track. But, the testing on the full size caused many problems. To overcome these problem by full size test, the Railway Safety Research Center in Seoul National University of Science & Technology developed 1/5 scale size of small scale derailment simulator and is currently testing running stability of 1/5 scaled bogie. Also To take effectively advantage of running stability test using small scale derailment simulator in actuality design and reliability estimation, it is necessary comparison and examination with field test and theoretical analysis result In this paper. to achieve running stability analysis of 1/5 scaled bogie on small scale derailment. the program using MATLAB that is fast compose and analysis the motion equation of Saemaul power bogie is developed. It is achieved analysis according to various specification (weight, size, suspension, etc..) and is evaluated corelation between test result and dynamic characteristic of actual railway vehicle.

  • PDF

진동대실험을 통한 축소 아치구조물의 고유진동주기 분석 (Natural Vibration Period of Small-scaled Arch Structure by Shaking Table Test)

  • 김기철;강주원
    • 한국공간구조학회논문집
    • /
    • 제15권4호
    • /
    • pp.107-114
    • /
    • 2015
  • Large spatial structures can not easily predict the dynamic behavior due to the lack of construction and design practices. The spatial structures are generally analyzed through the numerical simulation and experimental test in order to investigate the seismic response of large spatial structures. In the case of analysis for seismic response of large spatial structure, the many studies by the numerical analysis was carried out, researches by the shaking table test are very rare. In this study, a shaking table test of a small-scale arch structure was conducted and the dynamic characteristics of arch structure are analyzed. And the dynamic characteristics of arch structures are investigated according to the various column cross-section and length. It is found that the natural vibration periods of the small-scaled arch structure that have large column stiffness are very similar to the natural vibration period of the non-column arch structure. And in case of arch structure with large column stiffness, primary natural frequency period by numerical analysis is very similar to the primary natural frequency period of by shaking table test. These are because the dynamic characteristics of the roof structure are affected by the column stiffness of the spatial structure.

5×5 부분핵연료 집합체의 감쇠추정을 위한 실험적 연구 (Experimental Study on the Damping Estimation of the 5×5 Partial Fuel Assembly)

  • 이강희;윤경호;송기남
    • 한국소음진동공학회논문집
    • /
    • 제16권2호
    • /
    • pp.163-168
    • /
    • 2006
  • The PWR Nuclear Fuel assembly consists of more than 250 fuel rods that are supported by leaf springs in the cells of more than 10 Spacer Grids (SG) along the rod length. Since it is not easy to conduct mechanical tests on a full-scale model basis, the small-scaled rod bundle $(5\times5)$ which is called partial fuel assembly is generally used for various performance tests during the development stage. As one of the small-scaled tests, a flow test should be carried out in order to verify the performance of the spacer grid to obtain the Flow-Induced Vibration (FIV) characteristics of the scaled fuel assembly over the specified flow range. A vibration test should be also performed to obtain the modal parameters of the assembly prior to the flow test. In this study, we want to develop the estimation procedure of the damping ratio for the scaled test assembly. For the damping factor of the partial fuel assembly and the grid cage at the first vibration mode, as one of the vibration tests, a so-called pluck testing has been performed in air as a preliminary test prior to in-flow damping measurement test. Logarithmic decrement method is used for calculation of the damping ratio. Estimated damping ratio of the partial fuel assembly is about $0.7\%$ with reasonable error of $2\%$ for the previous results. Nonlinear behavior of the partial fuel assembly might be stem mainly from the rod-grid support configuration.

OMA testing by SLDV for FEM Updating

  • Milla, Brian-Mac;Mehdi Batel;Eddy Dascott;Ben Verbeeck
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.840-840
    • /
    • 2003
  • Operational Modal Analysis (OMA) is a technique for identification of modal parameters by measurement of only the system's response. On many lightweight structures, such as load-speaker cones and disk drive read/write heads, is impossible or impractical to measure the input forces. Another characteristic of lightweight structure is their sensitivity to mass loading from sensors. The Scanning Laser Doppler Vibrometry(SLDV) allows response measurements to be taken without mass loading. One disadvantage of OMA testing compared to tradition input output modal testing is the OMA mode shapes are un-scaled. This means that the mode shape obtained from an OMA test can not used for analytical structural modification studies. However, the un-scaled mode shapes from an OMA test can be used to update a Finite Element Model (FEM). The updated FEM can then be used to analytically predict the effect of structural modifications. This paper will present the results of an OMA test performed on a simple plate and motor in operating conditions. The un-scaled mode shapes from this test will be used to update a FEM model of the system. The updated FEM model will be then be used to predict the effect of attaching a mass to the plate. The shapes predicted by the FEM for the modified system will be compared to a second OMA test on the modified system

  • PDF

소형탈선시뮬레이터상에서의 1/5 축소대차 주행안정성 해석 (An Analysis of Running Stability of 1/5 Small Scaled Bogie on Small-Scaled Derailment Simulator)

  • 엄범규;강부병;이희성;송문석
    • 대한기계학회논문집A
    • /
    • 제36권11호
    • /
    • pp.1413-1420
    • /
    • 2012
  • 철도차량의 동적 거동 및 안정성 등을 예측하고 물리적인 특성을 이해하기 위하여 철도선진국인 영국, 프랑스, 일본 등에서는 축소모델 제작 및 시험하는 방법과 컴퓨터 시뮬레이션을 통하여 해석적으로 접근하는 방법이 사용되고 있다. 실물 규모의 동특성 시험은 대규모의 시험설비 구축에 따른 많은 비용과 시간의 소요, 그리고 시험 환경 설정의 어려움 등의 문제점이 발생하게 된다. 이러한 단점들을 극복하고자 상사법칙을 적용한 축소대차 모델을 이용하여 동적 시험 및 컴퓨터 시뮬레이션을 통한 해석적 연구를 수행하고 있다. 본 연구에서는 소형탈선시뮬레이터를 이용한 1/5 축소대차의 주행안정성 시험에서 신뢰성이 검증된 해석모델을 이용하여 주행안정성에 미치는 매개변수 중 주행속도, 차체 하중의 2가지 변수에 따른 1/5 축소대차의 주행안정성 해석을 수행하고, 그에 따른 동적특성을 검토하였다.

차세대 블레이드(NRSB-1M/2M)의 마하 스케일 성능시험 (The Mach-scale Performance Test of Next-Generation Blade(NRSB- 1M/2M))

  • 송근웅;김준호;김승호
    • 항공우주기술
    • /
    • 제5권2호
    • /
    • pp.27-36
    • /
    • 2006
  • 본 논문에서는 차세대 블레이드인 NRSB-lM과 NRSB-2M의 성능시험 절차 및 결과에 대해 기술하였다. 축소 블레이드 성능시험으로 공력 성능 시험과 소음 시험을 수행하였다. 공력 성능시험은 회전발란스를 이용하여 로터 추력 및 토오크를 측정하였고, 소음 측정시험은 마이크로폰을 이용하여 1.64D 위치에서 소음을 측정하였다. 측정된 성능 데이터는 무차원화하여 분석하였고, 두 블레이드 결과를 서로 비교하여 NRSB-2 블레이드가 더 좋은 블레이드 임을 확인하였다.

  • PDF

파괴인성의 축소모형실험 적용 연구 (Application of Fracture Toughness for Scaled Model Test)

  • 김종관
    • 터널과지하공간
    • /
    • 제30권1호
    • /
    • pp.87-97
    • /
    • 2020
  • 암석의 파괴인성은 발파, 굴착 등으로 인한 균열의 개시와 전파를 나타낼 수 있는 상수이다. 터널의 거동, 석회석 광산의 안정성 평가 등에 축소모형실험이 다양하게 적용되고 있다. 축소모형을 통해 발파로 인한 손상영역평가도 이뤄지고 있는데, 파괴 관련 인자에 대한 축소율 적용은 이뤄지지 않고 있다. 본 연구에서는 DCT(diametral compression test) 값과 유한요소법인 ATENA2D 수치해석 결과를 비교하여 암석의 파괴인성에 축소율을 적용할 수 있는지 확인하였다. 암석의 파괴인성에 이론적으로 계산된 축소율을 적용한 값과 DCT 시험결과 및 수치해석 결과가 각각 0.21~0.46, 0.40, 0.99MPa ${\sqrt{m}}$ 로 편차가 있으므로 암석의 파괴인성에 축소율을 적용 시에는 이 세 가지 값을 고려하여 적합한 축소율을 도출해야 하고, 축소모형 제작 시 축소율 적용 대상이 되는 길이, 시간, 질량과 함께 이로부터 산출되는 일축압축강도, 밀도 등의 주요 설계인자들의 축소율이 적용된 값을 함께 검토해야 할 것이다.