• 제목/요약/키워드: saw-cut

검색결과 105건 처리시간 0.029초

상아질의 경도, 위치 및 잔존 상아질 후경이 상아질에 대한 부위별 미세 전단결합강도에 미치는 영향 (REGIONAL MICRO-SHEAR BOND STRENGTH TO DENTIN:EFFECTS OF DENTINAL HARDNESS, POSITION, AND REMAINING DENTIN THICKNESS)

  • 황선성;임미경;이용근
    • Restorative Dentistry and Endodontics
    • /
    • 제23권1호
    • /
    • pp.401-412
    • /
    • 1998
  • The aim of this study was to measure the regional micro-shear bond strength of dentin bonding agents to dentin, and to investigate the relationship between the micro-shear bond strength and two dentinal characteristics ; Vickers hardness and remaining dentin thickness. Twenty-four freshly extracted, noncarious human molars were selected for this study. The materials tested in this study consisted of two commercially available dentin bonding agents (MAC-BOND, ONE-STEP) and two restorative light-cured composite resins (AELITEFIL, Z100). The occlusal or side surface of tooth crown was sectioned to expose dentin, and the exposed surface was finally polished with # 600 sandpaper. Four groups of application methods were used combining the filling materials and the dentin bonding agents. The composite resin-attached tooth specimens were embeded in a cold cure acrylic resin, and were cut with a low speed diamond saw to the dimension of 1mm $\times$ 1mm. Nine specimens were obtained from each tooth. The cut specimens were divided into three groups depending on the position of the dentin bonding surface. The micro-shear bond strength, remaining dentin thickness, and dentinal hardness were measured. Experimental results were then statistically analyzed with ANOVA. t-test, Scheffe test, and regression analysis. From this experiment, the following results were obtained : 1. In the case of occlusal surface bonding, the pooled micro-shear bond strength of ONST-AELIT group (16.62 MPa) was significantly higher than that of MACB-AELIT group (9.91 MPa) (p<0.05). However, there was no significant difference in the micro-shear bond strength depending on the dentin position (p>0.05). 2. In the case of side surface bonding of crown, the pooled micro-shear bond strength of four different bonding groups was not significantly different among each other (p>0.05). However, in three of the test groups (ONST-AELIT, MACB-Z100, ONST-Z100), the micro-shear bond strength to the lower 1/3(III) position was significantly lower than that to middle 1/3(II) position of surface (p<0.05). 3. In the ONST-AELIT bonding group, the pooled micro-shear bond strength to the occlusal surface was significantly lower than that to the side surface of crown (p<0.05). 4. There was no significant correlation between the micro-shear bond strength and dentin hardness / remaining dentin thickness (p>0.05).

  • PDF

주기전단 하중하의 암석 절리의 역학적 거동에 관한 실험적 연구 (A Experimental Study for the Mechanical Behavior of Rock Joints under Cyclic Shear Loading)

  • 이희석;박연준;유광호;이희근
    • 터널과지하공간
    • /
    • 제9권4호
    • /
    • pp.350-363
    • /
    • 1999
  • 주기전단하중 하의 암석 절리에 대한 역학적 거동을 규명하기 위해 정밀 주기전단시험 장치를 설계·제작하였다. 실험실에서 황등화강암과 여산대리석 인공 절리 시료로 펑면절리와 거친 절리에 대해 일련의 주기전단시험을 실시하였다. 시료에 대한 레이저 변위계를 이용한 3차원 거칠기 측정을통해 절리의 거칠기 특성을규명하였다. 주기전단시험 결과를 통해 주기전단 과정의 단계별 거동 특성과하중과제하시의 거동 차이, 전단거동의 이방성 등을고찰하였다. 거친 절리면의 역학적 거동 특성은 주로 2차 거칠기의 영향과 암석 재료의 높은 강도에 영향을 받았다. 주기전단시 거친 절리에 대한 돌출부 손상이 지수적인 거칢각 손상 법칙을 따름을 실험적으로 검증하였으며, 수직응력파 거칠기 종류, 하중 단계에 따라 돌출부들의 손상 기구가 다름을 확인하였다.

  • PDF

Mergers and Acquisitions as Vital Instruments of Corporate Strategy: Current and Historical Perspective

  • Sheikh, M. Jibran;Ahmed, Mah-a-Mobeen;Arshad, Qudsia;Shakeel, Wajid
    • The Journal of Asian Finance, Economics and Business
    • /
    • 제2권1호
    • /
    • pp.15-21
    • /
    • 2015
  • In this paper our main focus is to provide insight into the history of M&A's for this purpose we have analysed the different waves of M&A. We have analysed these waves in context of available literature and fact and figures. During the study we realised that almost all of the waves of M&A's ended because of financial crises, although impact and severity of that crises may differ. We analysed the impact of current crises on M&A in global context and in order to establish how companies have and in post crises era i.e. after crises of 2007 onwards how the companies have changed their corporate strategies to accommodate M&A's. We have also analysed which factors fuelled M&A's in past and were these factors present in post crises era M&A activities. By first quarter of 2011 the many firms saw new growth opportunities in M&A activities seemed to rebound as large companies used M&A's as part of their corporate strategy but this was cut short by events like US debt ceiling, down grade of USA's credit ratings along with fears about Eurozone's financial health and their impact on future prospects of M&A's would they continue to prosper or would they be weighed down by these events.

연속철근콘크리트 포장의 횡방향 철근 설계방법 및 시공관련 이슈 검토 (Construction Issues and Design Procedure for Transverse Steel in Continuously Reinforced Concrete Pavement (CRCP))

  • 최판길;원문철
    • 한국도로학회논문집
    • /
    • 제16권4호
    • /
    • pp.1-9
    • /
    • 2014
  • PURPOSES: The objective of this study is to evaluate construction issues and design for transverse steel in continuously reinforced concrete pavement(CRCP). METHODS : The first continuously reinforced concrete pavement(CRCP) design procedure appeared in the 1972 edition of the "AASHTO Interim Guide for Design of Pavement Structures", which was published in 1981 with Chapter 3 "Guide for the Design of Rigid Pavement" revised. A theory that was accepted at that time for the analysis of steel stress in concrete pavement, called subgrade drag theory(SGDT), was utilized for the design of reinforcement of CRCP - tie bar design and transverse steel design - in the aforementioned AASHTO Interim Guide. However SGDT has severe limitations due to simple assumptions made in the development of the theory. As a result, any design procedures for reinforcement utilizing SGDT may have intrinsic flaws and limitations. In this paper, CRCP design procedure for transverse steel was introduced and the limitations of assumptions for SGDT were evaluated based on various field testing. RESULTS: Various field tests were conducted to evaluate whether the assumptions of SGDT are reasonable or not. Test results show that 1) temperature variations exist along the concrete slab depth, 2) very little stress in transverse steel, and 3) warping and curling in concrete slab from the field test results. As a result, it is clearly revealed out that the assumptions of SGDT are not valid, and transverse steel and tie bar designs should be based on more reasonable theories. CONCLUSIONS : Since longitudinal joint is provided at 4.1-m spacing in Korea, as long as joint saw-cut is made in accordance with specification requirements, the probability of full-depth longitudinal cracking is extremely small. Hence, for transverse steel, the design should be based on the premise that its function is to keep the longitudinal steel at the correct locations. If longitudinal steel can be placed at the correct locations within tolerance limits, transverse steel is no longer needed.

타액에 의한 오염이 상아질 접착제의 미세전단결합강도에 미치는 영향 (EFFECT OF SALIVARY CONTAMINATION OF TEETH ON MICROTENSILE BOND STRENGTH OF VAR10US DENTIN BONDING SYSTEMS.)

  • 최경규;류길주
    • Restorative Dentistry and Endodontics
    • /
    • 제28권3호
    • /
    • pp.203-208
    • /
    • 2003
  • The purpose of this study was to evaluate the effect of salivary contamination of teeth on bonding efficacy of self-priming and self-etching DBSs. The materials used were Single Bond(SB, self-priming system, 3M), Unifil Bond(UB, self-etching system, GC), and Scotchbond Multi-Purpose Plus(SM, 3M) as control. Forty five human molars randomly allocated to three groups as dentin bonding systems tested and embedded in epoxy resin. Then the specimens were wet-ground to expose flat buccal enamel surface or flat occlusal dentin surface and cut bucco-lingually to form two halves with slow speed diamond saw. One of them was used under non-contamination, other under contamination with saliva. The bonding procedure was according to the manufacturer's directions and resin composite(Z-100, 3M Dental Products, St. Paul, MN) was built-up on the bonded surface 5mm high. The specimens were ground carefully at the enamel-composite interface with fine finishing round diamond bur to create an hour-glass shape yielding bonded surface areas of $1.5{\pm}0.1\textrm{mm}^2$. The specimens were bonded to the modified microtensile testing apparatus with cyanoacrylate, attached to the universal testing machine and stressed in tension at a CHS of 1mm/min. The tensile force at failure was recorded and converted to a tensile stress(MPa). Mean values and standard deviations of the bond strength are listed in table. One-way ANOVA was used to determine significant difference at the 95% level. The bond strength of SBMP and SB were not affected by salivary contamination, but that of UB was significantly affected by salivary contamination. These results indicate that DBSs with total etch technique seems less likely affected by salivary contamination in bonding procedure.

라미네이트 도재와 복합레진 시멘트의 결합강도에 관한 연구 (A STUDY ON THE VOND STRENGTH OF PORCELAIN LAMINATE AND COMPOSITE RESIN CEMENTS)

  • 김성일;임호남;박남수
    • 대한치과보철학회지
    • /
    • 제29권1호
    • /
    • pp.91-109
    • /
    • 1991
  • The purpose of this study were to comfirm the effects of the thickness and kinds of porcelain, etchants, illumination time, elapsed time for the measurement, and chemical cure component to the bond strength of porcelain laminate and composite resin cement, and to compare the effects between the light cured resin and the dual cured resins. The etched porcelain surface, the sectioned surface crossing porcelain and resin after bonding, and the debonded surfaces were observed by the SEM. One product of laminate porcelain powder, one light cured resin and two dual cured resins were selected. Each resin cements are lightened through the thin porcelain disc which was cut from cylindrical porcelain specimen by the diamond saw, and by the light through the porcelain disc they were bonded. Changes of thickness and kinds of porcelain, etchants, illumination time, and the elapsed time for the measurement were considered as variables for the bond strength. And the bond strength of porcelain and dual cured resins under the conditions of autopolymerization or the removal of chemical cure component were measured and compared. Bond strength were measured by shear stress. The etched surface, the cross-sectioned surface, and the debonded surface of porcelain or resin were observed by SEM. On the summary of this study, the following conclusions can be stated; 1. Bond strength of light cured resin was decreased inversely by the thickened porcelain laminate and showed the lowest value to the masking dentin porcelain among 4 kinds of porcelain powder. 2. Bond strength of autopolymerization of dual cured resin without illumination in dark chamber were from 75% to 98% to the data of dual cured resin with illumination. 3. Bond strength of dual cured resin used without chemical cured components were same to them of light cured resin. 4. Cross-sectioned surface treated by silane did not show the gap between the porcelain and resin. 5. Illumination over 80 seconds did not make the significant increase of bond strength on all kinds of resin.

  • PDF

상아세관의 주행방향에 따른 상아질 접착제의 침투양상에 대한 공초점레이저주사현미경 연구 (EFFECT OF DENTINAL TUBULES ORIENTATION ON PENETRATION PATTERN OF DENTIN ADHESIVES USING CONFOCAL LASER SCANNING MICROSCOPY)

  • 김동준;황윤찬;김선호;오원만;황인남
    • Restorative Dentistry and Endodontics
    • /
    • 제28권5호
    • /
    • pp.392-401
    • /
    • 2003
  • The purpose of this study was to evaluate the penetration pattern of dentin adhesives according to the orientation of dentinal tubules with confocal laser scanning microscopy. Specimens having perpendicular. parallel and oblique surface to dentinal tubules were fabricated. The primer of dentin adhesives (ALL $BOND^{\circledR}{\;}2,{\;}CLEARFIL^{TM}$ SE BOND and PQ1) was mixed with fluorescent material. rhodamine B isothio-cyanate (Aldrich Cherm. CO., Milw., USA), It was applied to the specimens according to the instructions of manufactures. The specimens were covered with composite resin (Estelite, shade A2) and then cut to a thickness of 500$\mu\textrm{m}$ with low speed saw (Isomet^{TM}, Buehler. USA). The adhesive pattern of dentin adhesives were observed by fluorescence image using confocal laser scanning microscopy. The results were as follows. 1. For the groups with tubules perpendicular to bonded surface. funnel shape of resin tag was observed in all specimen. However. resin tags were more prominent in phosphoric acid etching system (ALL $BOND^{\circledR}$ 2 and PQ1) than self etching system ($CLEARFIL^{TM}$ SE BOND). 2. For the groups with tubules parallel to bonded surface. rhodamine-labeled primer penetrated into peritubular dentin parallel to the orientation of dentinal tubules. But rhodamine-labeled primer of PQ1 diffused more radially into surrounding intertubular dentin than other dentin adhesive systems. 3. For the groups with tubules oblique to bonded surface. resin tags appeared irregular and discontinuous. But they penetrated deeper into dentinal tubules than other groups.

대추나무 미친병에 관한 연구 3 (Withes Broom of Jujube Tree, Zizyphus jujube Mill, Var. inermis Rehd.(Part.3))

  • 김종진
    • 미생물학회지
    • /
    • 제3권1호
    • /
    • pp.1-6
    • /
    • 1965
  • Over a period of 1962-64, a transmission-experiment of witchess' broom of jujube tree by stem-grafting was conducted. When stem-grafting of sound scions upon diseased roots or diseased scions upon sound roots were carried out, disease transmission of high rate was witnessed; 99% in the former and, in the latter, 62% of the stocks which saw union by callussing and had new shoots. Even when the diseased scions by stem-grafting or the diseased buds by budding upon sound stock died away, the transmission rate was 21% in stem-grafting and 14% in budding which seems to show that, when tissues of diseased plants and stocks are kept contacted over a certain period, the disease transmission occurs. And when the recovered scions taken from once diseased tree were grafted upon diseased roots, the transmission rate was 100 % and therefore it is presumed that the immunity could not be acquired even under the assumption of complete recovery from the disease. In stem-grafting of the diseased scions upon sound roots, 98% of the scions which were stored in the cellar, overwintered and grafted in spring was diseased, whereas the disease rate of the scions which were cut and grafted in spring was only 33%. It was particularly noteworthy that 90% of the scions in the former case and only 3% in the latter case were diseased as of June 18th approximately 2 months after the actual grafting and then the latter advanced to 33% with the passage of time. It appears that the pathogen in branches and shoots of the diseased trees standing outdoors become inactivated or diminished during winter. Through its symptom, pathological change in tissue, and easy transmission of the disease via stem-grafting, it seems certain that the pathogen of the witches broom disease in jujube tree is a virus.

  • PDF

강섬유를 보강한 자기충전 콘크리트의 휨 성능 평가를 위한 실험 연구 (An Experimental Study to Evaluate the Flexural Performance of Steel Fiber-Reinforced Self-Compacting Concrete)

  • 박연동
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제13권6호통권58호
    • /
    • pp.166-175
    • /
    • 2009
  • 강섬유보강 자기충전 콘크리트의 휨 성능을 평가하기 위하여 실험을 중심으로 한 연구를 수행하였다. 보 시험체를 만들기 위하여 3종류의 강섬유보강 콘크리트로 7개의 슬래브를 제작하였으며, 일정 기간 양생 후 다이아몬드 날이 달린 절단기로 슬래브를 절단하여 1개의 슬래브 당 5개의 보 시험체를 획득하였다. 각 보 시험체의 하중-처짐 곡선은 변위조절방식을 사용하여 구하였다. 실험 결과, 자기충전 콘크리트는 휨강도 및 연성, 인성지수 등 휨 성능을 평가하는 모든 부분에서 일반 콘크리트보다 양호한 성능을 보여주었다. 결과적으로 다짐이 필요없는 강섬유보강 자기충전 콘크리트는 강섬유보강 콘크리트의 가장 큰 단점인 시공성 저하 문제를 획기적으로 개선할 뿐만 아니라 역학적 성질도 양호하여 향후 토목 건축 분야에서 폭넓게 활용될 수 있을 것으로 생각된다.

Pre-Hospital and In-Hospital Management of an Abdominal Impalement Injury Caused by a Tree Branch

  • Ahn, So Ra;Lee, Joo Hyun;Kim, Keun Young;Park, Chan Yong
    • Journal of Trauma and Injury
    • /
    • 제34권4호
    • /
    • pp.288-293
    • /
    • 2021
  • In South Korea, most patients who visit trauma centers with abdominal injuries have blunt trauma, and penetrating injuries are relatively rare. In extremely rare cases, some patients are admitted with a long object penetrating their abdomen, and these injuries are referred to as abdominal impalement injuries. Most cases of impalement injuries lead to fatal bleeding, and patients often die at the scene of the accident. However, patients who survive until reaching the hospital can have a good prognosis with optimal treatment. A 68-year-old female patient was admitted to the trauma center with a 4-cm-thick tree branch impaling her abdomen. The patient was transported by a medical helicopter and had stable vital signs at admission. The branch sticking out of the abdomen was quite long; thus, we carefully cut the branch with an electric saw to perform computed tomography (CT). CT revealed no signs of major blood vessel injury, but intestinal perforation was observed. During laparotomy, the tree branch was removed after confirming that there were no vascular injuries, and enterostomy was performed because of extensive intestinal injury. After treating other injuries, the patient was discharged without any complications except colostomy. Abdominal impalement injuries are treated using various approaches depending on the injury mechanism and injured region. However, the most important consideration is that the impaled object should not be removed during transportation and resuscitation. Instead, it should only be removed after checking for injuries to blood vessels during laparotomy in an environment where injury control is possible.