• Title/Summary/Keyword: saturation zone

Search Result 108, Processing Time 0.044 seconds

The Formation of Transient Saturation Zone and the Subsurface flow on the Steep Hillslope by Rains (降雨에 의한 急斜面의 일시적인 飽和帶形成과 중간류 流出)

  • An, Jung-Gi
    • Journal of Korea Water Resources Association
    • /
    • v.31 no.2
    • /
    • pp.167-176
    • /
    • 1998
  • On steep hillslopes, saturation zone formations and subsurface flows were monitored through the observation systems of observation wells, tensiometers and trenches. By the 103 mm rain which had fallen on the hillslope with dry soil moisture, the saturation zone began to be formed at the top of hillslope during the rain and developed to be formed within a few hours after the end of rain on all hillslope. Subsurface water outflowed mainly from the soil profile of 0-40 cm depth, but did not outflow from the one of 40-80 cm depth. This saturation zone seemed to be formed by partially saturation of soil. This resulted for two reasons. Firstly, the saturation zone was formed by a smaller amount of rain than that required. Secondly the soil at a certain depth below the water table was unsaturated. Saturation zones formed by pre-rains responded rapidly to rains and subsurface water outflowed mainly from the soil profile of 40-80 cm depth simultaneously with the rising of the water level. The rates of subsurface discharge from the soil profile of 40-80 cm depth to the precipitation were related to the antecedent precipitation although the maximum water levels of saturation zone formed by four rains were similar.

  • PDF

Analysis of a Crack in Ferroelectric Ceramics Subjected to Electric Fields (전기장을 받는 강유전체 세라믹내의 균열 해석)

  • 범현규;김인옥
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.6
    • /
    • pp.138-144
    • /
    • 2003
  • A crack in a ferroelectric ceramic subjected to an electric field is analyzed. The boundary of the electrical saturation zone is estimated based on the finite-width saturation zone model, which is analogous to a finite-width Dugdale zone model for mode III. It is shown that the shape and size of the switching zone depends strongly on the boundary of the electrical saturation zone and the ratio of the coercive electric field to the yield electric field. The crack tip stress intensity factor under small scale conditions is evaluated by employing the model of electric nonlinear domain switching. It is found that fracture toughness of the ferroelectric material may be increased or decreased depending on the material property of electrical nonlinearity.

A Comparison between the Internal Saturation Temperature of Working Fluid and the Surface Temperature of Adiabatic Zone of Two-Phase Closed Thermosyphons with Various Helical Grooves (평관형 및 나선 그루브형 열사이폰 내부 작동유체의 포화온도와 단열부의 표면온도에 관한 연구)

  • Han, K.I.;Cho, D.H.;Park, J.U.;Lee, S.J.
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1243-1249
    • /
    • 2004
  • This study is focused on the comparison between the internal saturation temperature of the working fluid and the surface temperature of adiabatic zone of two-phase closed thermosyphons with various helical grooves. Distilled water, methanol and ethanol have been used as the working fluid. In the present work, a copper tube of the length of 1200mm and 14.28mm of inside diameter is used as the container of the thermosyphon. Each of the evaporator and the condenser section has a length of 550mm, while the remaining part of the thermosyphon tube is adiabatic section. A experimental study was carried out for analyzing the performances of having 50, 60, 70, 80, 90 helical grooves. A plain thermosyphon having the same inner and outer diameter as the grooved thermosyphons is also tested for the comparison. The results show that the numbers of grooves and the type of working fluids are very important factors for the operation of thermosyphons. A good agreement between the internal saturation temperature of working fluid and the surface temperature of adiabatic zone of two-phase closed thermosyphons with various helical grooves is obtained.

  • PDF

Assessing Distribution of Degree of Saturation for Track Transition Zone Using Soil Water Characteristic Curve (접속부 궤도 성토재료의 함수특성곡선을 이용한 포화도 분포 산정)

  • Choi, Chanyong;Lee, Jungmin;Kwon, Hyeok Min;Oh, Jeongho
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.35 no.2
    • /
    • pp.515-524
    • /
    • 2015
  • The number of occurrence of differential settlement and track irregularity at track transition zone recently comes to increase, which leads to frequent maintenance activities that have an impact on train operation. Such track transition zone damages are attributed to the change of mechanical properties of fill materials due to environmental factors such as rainfall and freeze, and thaw. Consequently, this study attempts to establish the soil water characteristic curve (SWCC) of fill materials, and conduct seepage analysis to assess the distribution of degree of saturation (DOS) for track transition zone in case of rainfall. The SWCC of fill materials was successfully obtained using filter paper test method. The results of seepage analysis revealed that rainfall intensity, the slope of backfill, backfill condition (fill or cut), and SWCC are significantly influential in controlling the distribution of DOS.

Analysis of Saturation and Ground Water Level at Embankment by TDR Sensor (TDR센서를 이용한 제방의 포화도 및 지하수위 해석)

  • Kim, Ki-Young;Han, Heui-Soo;Lee, Jae-Ho;Park, Min-Cheol
    • Journal of the Korean Geotechnical Society
    • /
    • v.27 no.2
    • /
    • pp.63-72
    • /
    • 2011
  • The measured ground water behavior by TDR (time domain reflectometer) sensors were analyzed by the data filtering technique such as moving average method and Fourier transform, and the ground water level and unsaturated zone were tried to be determined numerically. At first, the variation of TDR data according to the saturation degree was measured by lab test, which is translated as a function of saturation degree. Then, changes of ground water level and lateral seepage in field conditions were simulated using acrylic pipe, and the measured data were analyzed to make calibration curve. Furthermore, TDR sensors were installed into the in-situ embankment to insure the field application. The saturation degree, unsaturated and dried zones were determined from the measured data.

Reference Model Feedback Control and Stability Evaluation for Control System with Hard Non-linearities (견비선형을 갖는 제어시스템에 대한 기준모델 피드백제어 및 안정성평가)

  • Jung, Yu-Chul;Lee, Gun-Bok
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.15 no.5
    • /
    • pp.72-78
    • /
    • 2006
  • The paper proposes reference model error feedback control scheme for motion control system with hard non-linear components as like saturation and dead-zone in plant input part. Additionally, the plant has the system uncertainty effected by plant model parameter deviation and disturbance. The control algorithm uses the reference model to apply additional feedback loop with the error between reference model output and actual output effected by disturbance and non-linear components. And the stability evaluation based on Popov stability and controller design method are formulated to be performed. The effectiveness of the proposed scheme is examined by simulations. The results are proven by reasonable performances following reference model responses with good disturbance rejection performance without over-tuning of controller.

Removal of Non-volatile Contaminant from Aquifer using Surfactant-enhanced Ozone Sparging (오존과 계면활성제를 이용한 대수층 내 비휘발성 물질 제거)

  • Yang, Su-Kyeong;Shin, Seung-Yeop;Kim, Heon-Ki
    • Journal of Soil and Groundwater Environment
    • /
    • v.15 no.6
    • /
    • pp.37-45
    • /
    • 2010
  • Surfactant-enhanced ozone sparging (SEOS), an advanced version of SEAS (surfactant-enhance air sparging) was introduced in this study for the first time for removal of non-volatile contaminant from aquifer. The advantages of implementing SEAS, enhanced air saturation and expanded zone of sparging influence, are combined with the oxidative potential of ozone gas. Experiments conducted in this study were tow fold; 1-dimensional column experiments for the changes in the gas saturation and contaminant removal during sparging, and 2-dimensional box model experiment for the changes in the size of zone of influence and contaminant removal. An anionic surfactant (SDBS, sodium dodecylbenzene sulfonate) was used to control surface tension of water. Fluorescein sodium salt was used as a representative of watersoluble contaminants, for its fluorescence which is easy to detect when it disappears due to oxidative degradation. Three different gases (air, high-concentration ozone gas, and low-concentration ozone gas) were used for the sparging of 1-D column experiment, while two gases (air and low-concentration ozone gas) were used for 2-D box model experiment. When SEOS was performed for the column and box model, the air saturation and the zone of influence were improved significantly compared to air sparging without surface tension suppression, resulted in effective removal of the contaminant. Based on the experiments observations conducted in this study, SEOS was found to maintain the advantages of SEAS with further capability of oxidative degradation of non-volatile contaminants.

An Analysis on the Residual Stress of Subsurface Zone due to Rolling Contact (회전접촉에 의해 발생하는 Subsurface Zone의 잔류응력에 관한 해석)

  • Gang, Gye-Myeong;Kim, Seon-Jin
    • Korean Journal of Materials Research
    • /
    • v.3 no.1
    • /
    • pp.58-64
    • /
    • 1993
  • The degree of work hardening in the subsurface zones varied with the experimental conditions under the rolling contact fatigue wear test of high carbon Cr-Ti alloy steel was evaluated by the distribution of residual stresses. Surface residual stresses before the test did not affect the wear property. Surface residual stresses after the test decreased by the increase of contact stress and running. velocity. but the maximum compressive residual stress and its depth of saturation in the subsurface zone increased. The relationship between these experimental results and the distribution of the theoritical shear stress was also discussed.

  • PDF

Borehole radar monitoring of infiltration processes in a vadose zone

  • Jang, Han-Nu-Ree;Park, Mi-Kyung;Kuroda, Seiichiro;Kim, Hee-Joon
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.313-316
    • /
    • 2007
  • Ground-penetrating radar (GPR) is an effectiveness tool for imaging spatial distribution of hydrogeologic parameters. An artificial groundwater recharge test has been conducted in Nagaoka City in Japan, and time-lapse crosshole GPR data were collected to monitor infiltration processes in a vadose zone. Since radiowave velocities in a vadose zone are largely controlled by variations in water content, the increase in traveltimes is interpreted as an increase in saturation in the test zone. We use a finite-difference time-domain method in two-dimensional cylindrical coordinates to simulate field results. Numerical modeling successfully reproduces the major feature of velocity changes in the filtration process.

  • PDF

Investigation of the Geoelectrical Response at the Hydrocarbon-impacted Zone (유류 오염대의 전기적 물성 특성 연구)

  • Kim, Chang-Ryol;Ko, Kyung-Seok;Kim, Jung-Ho
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.225-230
    • /
    • 2007
  • A physical model experiment with GPR and 3-D resisitivity survey were conducted to investigate the geoelectrical response of hydrocarbon-impacted zone, so called smeared zone, on the geophysical data. The results from the experiment show that GPR signals were enhanced when LNAPL was present as a residual saturation in the water saturated system (${\varepsilon}_r$ = 21) due to less attenuation of the electromagnetic energy through the medium, compared to when the medium was saturated with only water (${\varepsilon}_r$ = 21). 3-D resistivity data obtained from the former gas station site demonstrate that the highly contaminated zones could be imaged with low resistivities attributed to the biodegradation of petroleum hydrocarbons at the aged, hydrocarbon-impacted sites. The study results also show that the geophysical methods, as a non-invasive sounding technique, can be a very useful tool for mapping hydrocarbon-contaminated zones.

  • PDF