• 제목/요약/키워드: satellite tracking

검색결과 410건 처리시간 0.032초

APPLICABLE TRACKING DATA ARCS FOR NORAD TLE ORBIT DETERMINATION OF THE KOMPSAT-1 SATELLITE USING GPS NAVIGATION SOLUTIONS

  • Lee, Byoung-Sun
    • Journal of Astronomy and Space Sciences
    • /
    • 제22권3호
    • /
    • pp.243-248
    • /
    • 2005
  • NORAD Two Line Element (TLE) is very useful to simplify the ground station antenna pointing and mission operations. When a satellite operations facility has the capability to determine NORAD type TLE which is independent of NORAD, it is important to analyze the applicable tracking data arcs for obtaining the best possible orbit. The applicable tracking data arcs for NORAD independent TLE orbit determination of the KOMPSAT-1 using GPS navigation solutions was analyzed for the best possible orbit determination and propagation results. Data spans of the GPS navigation solutions from 1 day to 5 days were used for TLE orbit determination and the results were used as Initial orbit for SGP4 orbit propagation. The operational orbit determination results using KOMPSAT-1 Mission Analysis and Planning System(MAPS) were used as references for the comparisons. The best-matched orbit determination was obtained when 3 days of GPS navigation solutions were used. The resulting 4 days of orbit propagation results were within 2 km of the KOMPSAI-1 MAPS results.

GA를 이용한 최적 위성추적 안테나 제어 시스템의 설계 (A Design on Optimal Satellite-Tracking Antenna Control system Using GA)

  • 정호성;김동완;황현준;김정태;김금영;김영훈;조원래
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 B
    • /
    • pp.549-551
    • /
    • 1998
  • In this paper, we design the optimal satellite-tracking antenna $H_{\infty}$ control system using genetic algorithm(GA). To do this, we give gain and dynamics parameters to the weighting functions and apply GA with reference model to the optimal determination of weighting functions and design parameter ${\gamma}$ that are given by Glover-Doyle algorithm which can design $H_{\infty}$ controller in the state space. These weighting functions and design parameter ${\gamma}$ are simultaneously optimized in tile search domain guaranteeing the robust stability of closed-loop system. The effectiveness of this satellite-tracking antenna $H_{\infty}$ control system is verified by computer simulation.

  • PDF

위성 추적용 Monopulse L-Band Dipole Feed부의 제작 (Monopulse L-Band Dipole Feed For The Satellite Tracking)

  • 천병진;홍성용;이재현;나정웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1987년도 전기.전자공학 학술대회 논문집(I)
    • /
    • pp.82-85
    • /
    • 1987
  • Electromagnetic waves from the satellite may be utilized to direct the tracking antenna toward the satellite. We design and fabricate the feed appropriate to the monopulse tracking technique which derive angle-error information on the basis of a single pulse. The feed consists of five cavity-backed turnstile elements mounted on a common ground plane. The turnstile dipole are connected to a set of five quadrature hybrids which convert the dual linear polarization into dual circular polarization. The five feed outputs are then processed in the monopulse comparator which is constructed in microstrip for compactness.

  • PDF

다중경로 채널에서 정합필터를 이용한 코드 추적 루프최대 우도 알고리즘 (A Maximum Likelihood Method of Code Tracking Loop Using Matched Filter in Multi-path Channel)

  • 손승호;이상욱
    • 한국위성정보통신학회논문지
    • /
    • 제5권1호
    • /
    • pp.54-57
    • /
    • 2010
  • 위성 기반 측위 시스템은 위치 기반 기술의 핵심 기술로서, CDMA 시스템을 사용한다. CDMA 시스템에서 원활한 위치 측위를 하기 위해서는 확산 부호의 정확한 동기가 이루어져야 한다. 본 논문은 확산 부호의 동기 기법 가운데 부호 추적 기법에 초점을 맞춘다. 특히 다중 경로 환경에서 기존의 부호 추적 기법인 DLL 방법은 적합하지 않다. 본 논문은 수신 신호에서 다중 경로 신호를 축출하여 이를 부호 추적 기법에 사용하는 방법을 제안한다. Spirent simulator를 이용하여 제안 기법을 검증하고 성능 평가를 보인다.

도플러 효과를 이용한 단일 저궤도위성의 동물추적시스템 개발 (Animal Tracking System Using the Doppler Effect for Single LEO Satellite)

  • 이정남;장영근;이병훈;문병영
    • 한국항공우주학회지
    • /
    • 제34권11호
    • /
    • pp.61-69
    • /
    • 2006
  • 도플러 효과를 이용해서 동물의 위치를 추적하는 경우 동물에 장착된 단말기의 송신신호를 위성의 수신기에서 얼마나 많이, 정확하게 측정하느냐에 따라 위치 추적의 정밀도가 달라진다. ARGOS 위성시스템의 경우 다수의 위성을 운용하여 단말기의 송신신호를 비교적 많이 측정하며, 이러한 많은 측정 데이터를 이용해서 상당히 높은 위치추적 정밀도를 유지하고 있다. 하지만 단일 위성을 사용하는 동물추적시스템의 경우 위성이 단말기를 통과하는 짧은 시간동안 송신 신호를 많이 측정하기 힘들며, 이는 위치추적의 정밀도를 떨어뜨리는 가장 큰 원인이 된다. 따라서 본 논문에서는 단일 위성에서 도플러 천이 측정 데이터의 개수를 증가시키기 위해서 도플러 천이 변화율을 이용하여 수신 데이터를 추정하였으며, 추정된 데이터를 측정치로 사용하여 측정 데이터의 개수를 증가 시켰다. 결과적으로 도플러 천이 변화율을 이용하여 비교적 높은 위치추적 정밀도를 획득 할 수 있으며, 단일 위성을 사용하는 동물추적시스템에 적합한 방식임을 알 수 있다.

Space Surveillance Radar Observation Analysis: One-Year Tracking and Orbit Determination Results of KITSAT-1, "우리별 1호"

  • Choi, Jin;Jo, Jung Hyun;Choi, Eun-Jung;Yu, Jiwoong;Choi, Byung-Kyu;Kim, Myung-Jin;Yim, Hong-Suh;Roh, Dong-Goo;Kim, Sooyoung;Park, Jang-Hyun;Cho, Sungki
    • Journal of Astronomy and Space Sciences
    • /
    • 제37권2호
    • /
    • pp.105-115
    • /
    • 2020
  • The Korean Institute of Technology Satellite (KITSAT-1) is the first satellite developed by the Satellite Technology Research Center and the University of Surrey. KITSAT-1 is orbiting the Earth's orbit as space debris with a 1,320 km altitude after the planned mission. Due to its relatively small size and altitude, tracking the KITSAT-1 was a difficult task. In this research, we analyzed the tracking results of KITSAT-1 for one year using the Midland Space Radar (MSR) in Texas and the Poker Flat Incoherent Scatter Radar (PFISR) in Alaska operated by LeoLabs, Inc. The tracking results were analyzed on a weekly basis for MSR and PFISR. The observation was conducted by using both stations at an average frequency of 10 times per week. The overall corrected range measurements for MSR and PFISR by LeoLabs were under 50 m and 25 m, respectively. The ionospheric delay, the dominant error source, was confirmed with the International Reference of Ionosphere-16 model and Global Navigation Satellite System data. The weekly basis orbit determination results were compared with two-line element data. The comparison results were used to confirm the orbital consistency of the estimated orbits.

방위각 고정 기법을 이용한 개선된 Tracking Parameter File 생성 방법 (An Improved Tracking Parameter File Generation Method using Azimuth Fixing Method)

  • 전문진;김응현;임성빈
    • 항공우주기술
    • /
    • 제12권2호
    • /
    • pp.1-6
    • /
    • 2013
  • 저궤도 위성은 지상국과의 접속 중에 X-band 안테나를 이용해 촬영한 영상을 전송한다. X-band 안테나는 교신 시간 동안 TPF (tracking parameter file)에 따라 움직이며 지상국의 안테나를 지속적으로 지향한다. TPF 생성 소프트웨어는 위성의 궤도 및 자세 정보와 촬영 및 다운링크 임무 정보를 이용해 X-band 안테나가 지상국을 지향하도록 하는 Azimuth, Elevation 정보를 생성한다. 위성이 지상국 상공을 지나가는 경우 X-band 안테나 특성 상 방위각 속도가 급격하게 증가하며, 특정 각속도로 회전하는 경우 위성의 지터를 유발할 수 있다. 영상촬영과 다운링크를 동시에 수행하는 실시간 임무의 경우 지터에 의한 영상 열화를 방지하기 위해 Azimuth 각속도를 일정 수준 이하로 낮춰야 한다. 현재 사용하는 방법인 한 점의 가상 지상국을 지향하는 방법으로는 각속도를 낮추는데 한계가 있다. 이 논문에서는 방위각 고정 기법을 이용해 X-band 안테나의 Azimuth 각속도를 낮추는 방법을 제안한다. 시뮬레이션 결과는 제안된 방법을 이용해 방위각 속도가 현저하게 감소함을 나타낸다.

1.5m급 다목적형 레이저 추적 시스템 예비 성능 분석 (Preliminary Perfomances Anlaysis of 1.5-m Scale Multi-Purpose Laser Ranging System)

  • 손석현;임재성
    • 한국항공우주학회지
    • /
    • 제49권9호
    • /
    • pp.771-780
    • /
    • 2021
  • 우주물체 레이저 추적(DLR : space Debris Laser Ranging) 시스템은 인공위성까지의 거리를 측정하는 인공위성 레이저 추적(SLR : Satellite Laser Ranging) 시스템의 확장형이라고 할 수 있다. 레이저를 발사하여 수신하는 광자 왕복하는 시간을 측정하여 궤도 결정하는 시스템이다. 거리 정밀도는 mm급 단위로 측정 가능하고 현존하는 시스템 중 가장 정밀한 시스템이다. 현재 한국천문연구원은 인공위성 레이저 추적 시스템을 세종 및 거창에 구축하였고, 나로호 과학위성, 다목적 실용위성 5호의 정밀궤도를 검증하기 위해 SLR 데이터를 활용하였다. 최근 몇 년간 우주쓰레기의 추락 또는 충돌로 인해 자국의 위성이 위협받고 있고, 이는 안보적인 측면에서 자국 우주자산 보호, 국민의 안전을 보호하기 위해 우주물체 레이저 추적이 지대한 관심을 받고 있다. 본 논문에서는 인공위성 레이 추적, 우주물체 레이저 추적을 고려한 다목적형 레이저 추적 시스템의 시스템 설계를 위하여 1.5m 급 주경을 적용하였다. 그리고 주요 구성품의 성능(레이저 파장, 레이저 출력) 등을 고려하여 링크버짓 분석을 통해 시스템 예비 성능 분석을 수행하였다.

Performance Analysis of a Vector DLL Based GPS Receiver

  • Lim, Deok Won;Choi, Heon Ho;Lee, Sang Jeong;Heo, Moon Beom
    • Journal of Positioning, Navigation, and Timing
    • /
    • 제1권1호
    • /
    • pp.1-6
    • /
    • 2012
  • For a Global Positioning System (GPS) receiver, it is known that a Vector Delay Locked Loop (DLL) in which the code signals of each satellite are tracked in parallel by using navigation results shows better performance in the aspect of the tracking accuracy and the robustness than that of a Scalar DLL. However, the quantitative analysis and the logical grounds for that performance enhancement of the Vector DLL are not sufficient. This paper, therefore, proposes the structure of the GPS receiver with the Vector DLL and analyzes the performance of it. The tracking and the positioning accuracy of the Vector DLL are theoretically analyzed and confirmed by simulation results. From the simulation results, it can be seen that the tracking and positioning accuracy has been improved about 30% in case that the receiver is static and the positioning is conducted for every Pre-detection Integration Time (PIT) while C/N0 is 45 dB-Hz.

GPS L1/갈릴레오 E1 복합신호처리를 통한 위치정확도 향상 연구 (A Study on Enhanced Accuracy using GPS L1 and Galileo E1 Signal Combined Processing)

  • 신천식;이상욱;윤동원
    • 한국위성정보통신학회논문지
    • /
    • 제6권1호
    • /
    • pp.68-74
    • /
    • 2011
  • 본 논문은 GPS L1신호와 갈릴레오 E1 신호를 복합 신호처리를 통한 위치정확도 성능향상 연구결과를 제시하였다. GNSS 수신기에서의 신호획득 및 추적과정의 성능 향상시키기 위해 복수개의 누적기, 판별기 및 루프 필터 모듈을 적용하였고, 소프트웨어 측정 결과와 하드웨어 측정결과를 성능 비교하였다, 또한 추적과정에 대한 성능비교는 정확도와 민감도 측면에서만 다루었으며 갈릴레오 E1 신호처리를 위한 DLL(Delay Lock Loop) 판별기는 power early late 타입을 적용하여 성능을 검증하였다.