• Title/Summary/Keyword: sanitary standard

Search Result 179, Processing Time 0.024 seconds

A Study on the Standard Weather Data for Seoul (서울지방의 표준기상데이터에 관한 연구)

  • Kim, Doo-Chun
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.14 no.2
    • /
    • pp.125-137
    • /
    • 1985
  • Standard weather data for Seoul has been developed for use in computer calculations for energy requirements, and the 8760 sequential hourly values for seven weather elements have been placed in magnetic tape and cards. Applying the method determining average month, developed by Japanese Society of Heating, Air-Conditioning and Sanitary Engineers, the standard year data have been selected from the monthly average values for three weather elements during the 10year period of 1971 through 1980. The followings are obtained. 1. The Test Reference Year, consisting of 12 months chosen from different calendar years, has been determined, and TRY tape which contains seven weather elements has been prepared. 2. The Typical Weather Year, which means a year close to the average value, is the year of 1978 during the above 10 year period. 3. During the period, Winter Season needs the maximum heating load is from Dec. 1976 to Mar. 1977 and Summer Season needs the maximum cool ins load is from Jun. to Sep, 1978.

  • PDF

Groundwater Contamination by Cation, Anion and Pesticides (지하수중 음이온, 양이온, 및 금속의 함량)

  • 김형석;정세영;최중명
    • Journal of environmental and Sanitary engineering
    • /
    • v.7 no.2
    • /
    • pp.111-128
    • /
    • 1992
  • According to the increase of population and industrialization, the quality of our drinking water are becoming worse by the contamination of resources, production of THM and other halogenated hydrocarbons during the purifying process, the problem of corroded water supplying pipeline, and the water reservoir tanks, Many people choose groundwater to drink instead of city tap water, but sometimes we get report about groundwater contamination by wastes, swage, septic tank, etc. It is reported that in U. S. over 20% of population are drinking groundwater, but U. S EPA reported the groundwater contamination by pesticides, herbicides, fungicides, fertilizer, and various chemical substances. Craun, et at announced the groundwater contamination by bacteria which are related with poor installation of septic tank. Johnson and Kross mentioned aboutmethemoglobinemia by NO3-N originated from human and animal feces, organic chemicals, and fertilizer, and as the results the infant mortality could be risen. Some scientist also reported the high concentration of metals in groundwaters and some cation and anions, and volatile organic compou nds. Authors investigated 80 groundwaters in urban, agricultural, and industrial area during last 3 month(June - August) to check any drinking water quality parameters are exceeding the standards. The results were as follow. 1, The average value of ammonia nitrate were within the standard, but 11.76% of urban area were exceeded the 10 rpm standard, in agricultural area 42.3175 were exceeded, and in industrial area 20.2% were exceeded the drinking water standard of 10 ppm. the highest concentration was 29.37 ppd in industrial area. 2. The mean value of metals is not exceeded the standard, but there were some groundwater whose Mn value was 0.424 ppm(standard is 0,3 ppm) in urban area, 0.737 rpm in agricultural area, and 5.188 ppm in industrial area. The highest Zn value was 1.221 ppm (standard is 1.0 ppm)was found in industrial area. 3. The percentage of contamination by general bacteria was 8.82% in urban area, 15.38% in agricultural area, and 15.00% in industrial area. Escherichia coil group was also contaminated by 35.29% in urban area, 30.76% in agricultural area, and 30.00% in industrial area. 4, The pH value was within the standard which means there was no influence by acid or alkali chemicals, nor acid rain Through the above results, all the groundwater should be tested to check the safety for drinking water and should make some alternative methods suitable for drink.

  • PDF

A Study on the Nucleus System of Standard Hospitals in U.K. (영국의 표준병원에서 뉴클리우스 시스템에 대한 연구)

  • Moon, Chang-Ho
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.3 no.4
    • /
    • pp.59-68
    • /
    • 1997
  • This study is intended to review the Nucleus System of standard hospitals in U.K. The research is focused on the theoretical background, contents of Nucleus System, and the operational problems through the survey of sample hospitals. The contents of research include the development history of standardization, outlines, aimes, advantages, the data of Nucleus system, and the study-visits of sample hospitals. The conclusion could be summarized as follows ; 1) The form of standard hospitals is compact and low-rise the major movements are horizontal. The standard plans of the functional dpartments are unified as cruciform with $15m{\times}15m$ module. 2) The Nulceus System has been developed. The hospitals have 3 stories maximum and courtyards for natural light & ventilation. 3) The advantages of Nucleus System includes reduction of design & construction period, the buildability due to the repetitive construction, and the running cost. And the disadvantages are mentioned as the lack of storage, staff accomodation, pantry, and sanitary facilities. 4) Sample hospitals provide human scale, possibilities of growth & change, and curing environment from art decoration & artificial lake. 5) In case of Korean situation, even the minimum standardization such as hospital design guidelines should be developed in near future.

  • PDF

A Survey on the Envlronmcntal Sanitary Status of Water Supply System in Rural Area (농촌급수시설에 관한 환경위생확적 조사연구)

  • 박국환;김성자
    • Journal of Environmental Health Sciences
    • /
    • v.5 no.1
    • /
    • pp.76-85
    • /
    • 1978
  • This survey was undertaken for the period seven month beginning January 15, 1977 and ending July 31, 1977 to detect the general sanitary status of the villages and the villagers and, at the same time, analyse quality of water sources with emphasis on a total of 1,256 households dividing into three different groups: such as, 280 households were selected as random samples from the area of the sophisticated piped water supply system, 122 households from the area of the simplified water supply system and finally 854 households from the area of nonpi-ped water supply system. The following results were concluded after quality of water sources had been analysed and conditions of the environmental sanitation had been reviewed: 1. 11.2% of the respondents from the area of the sophisticated piped water supply system responded that quantity of drinking water lacked to meet their demand while 30.6% of the villagers from the area of nonpi-ped water supply system responded quantity of drinking water didn't meet their demand. 2. 30.8% of the.respondents from the area of the sophisticated water supply system responded that contaminating source located within 15 meters from the water source while 54.4% of the respondents from the non-piped water supply system claimed the same. 3. It was found that water from all sampling areas were positive in coliform group with exception of Moonsan which is one of the sophisticated piped water supply system groups and the number of general bacteria exceeded the government standard criteria of water quality in the area of the nonpi-ped water supply system. 4. In relation with time requirement to draw water in the area of non-piped water supply system, 76 respondents claimed it requires less than 15 minutes to draw water, 15.0% claimed 15 to 30 minutes and 9.0% claimed more than 30 minutes. 5. In relation with knowledge on sanitation of drinking water, 30.8% of respondents from the area of the sophisticated piped water supply system and 41.8% of respondents from the area of nonpiped water supply system denied possible existence of germ in drinking water they drink, while 17.4% of the respondents from the area of the sophisticated water supply system and 50.2% of non-peped water supply system thought it safe to drink water without any treatment. 6. 60.0% of the respondents from the area of non-piped water supply system and many of them believed that their health status will be improved by installation of a sophisticated water supply system in their area. 7. The respondents from the areas of piped water supply sytem expressed greater concern over drinking water sanitation than those from the areas of non-piped water supply system and sanitary conditions were found the same. It was, therefore, proved that knowledge of environmnntal sanitation contributed a great deal to improve sanitary conditions of the villages and villagers and at the same time health education, especially environmental sanitation, will be played a important role to improve their sanitary conditions.

  • PDF

A Study on the Sanitary Condition of Kitchens in Food Court/Cafeterias - An Observation on Seasonal Variations (휴게음식점 주방의 환경위생상태에 관한 조사연구 - 계절별 변화를 중심으로 -)

  • Kim, Jong-Gyu;Park, Jeong-Yeong;Kim, Joong-Soon
    • Journal of Environmental Health Sciences
    • /
    • v.38 no.2
    • /
    • pp.118-127
    • /
    • 2012
  • Objectives: This study was undertaken to assess the sanitary conditions in the kitchens of food court/cafeterias and determine seasonal variations. Methods: We measured environmental factors (air temperature, relative humidity, illumination intensity, noise level), and dropping airborne microbes (bacteria and fungi) in the kitchens of eight food court/cafeterias in four seasons (January, April, July, and October). Air temperature and relative humidity were measured with in/out thermo-hygrometers at 1.2-1.5 m above floor level. Illuminance measurement was performed through the multiple point method of Korean Standards (KS). Noise level was measured by the standard methods for the examination of environmental pollution (noise and vibration) of Korea. The estimation of dropping airborne bacteria and fungi was performed through use of Koch's method. Results: The highest kitchen air temperature was in July, and the lowest in January. The average temperature surpassed $21^{\circ}C$ throughout the seasons, suggesting a higher temperature than required for the safe handling of food. Humidity in all the kitchens was measured in the range of 50-60%. Half of the kitchens showed illumination intensities below 300 Lux in April. It was found that the sound pressure level of noise in almost all of the kitchens was higher than 85 dB (A). The highest levels of dropping airborne bacteria and fungi were noted in July. The numbers of airborne bacteria were higher than those of fungi. The levels of dropping airborne bacteria and fungi were affected by air temperature, relative humidity, season, and place. Conclusions: This study indicates that the kitchen environments were unqualified to supply safe food. The hygiene level of the kitchens should be improved.

Comparing School Lunch Program Served at Dining Room with Program at Classroom for Sanitation and Contentment at One Middle School (중학교 학교급식의 식당과 교실 배식의 급식만족도와 위생상태 비교)

  • Song, Hyun-Jung;Moon, Hyun-Kyung
    • Korean Journal of Community Nutrition
    • /
    • v.15 no.3
    • /
    • pp.369-378
    • /
    • 2010
  • School lunch programs at middle schools have increased in quantity. However, the quality of them is in fact not enough to reach the satisfactory standard, especially in the aspect of environment of school meals. It is true that there seems to be little attention to the environment. In this study, degree of satisfaction about school lunch program was surveyed for students in one middle school. Focus of survey was sanitary condition about the dining room and classroom where they have lunch. First, in order to investigate the degree of satisfaction about their dining place, questionnaire was sent out to the students at one middle school in Seoul. Questionnaire was made with reference to previous research. Second, for the study on environmental sanitation, dropping bacteria (general bacteria) is measured in three parts of dining place (entrance, serving table, dining table). Petriplate film was exposed to the responsible places for 15 minutes and then cultivated at the temperature of $32^{\circ}C$ for 48 hours before counting the number of bacteria formed. For the statistical analysis, SPSS 12.0 was used. The results of the study show that students had more satisfaction in dining room service than in classroom service. Important factors for the meal program such as "taste of food", "amount of food per student", "state of keeping warm", "appearance of food", "diversity of menu", and "kindliness of feeding staff" had more points in dining room than in classroom. For the environmental and sanitary aspect, the result of dropping bacteria (general bacteria) in dining room and classroom showed that table (5.00) and fooddistribution corner (8.67) of dining room were cleaner than those of classroom (P < 0.05). Making a good environment for school feeding will have a positive effect on the improvement of satisfaction and sanitation of school feeding. There should be expansion of dining room service for the students.

'Survey on Bacteriological Contamination of Moving Tavern in Seoul Area' ('노상주점의 위생상태에 관한 미생물학적 조사')

  • Yu Byong Tai
    • Journal of environmental and Sanitary engineering
    • /
    • v.1 no.1 s.1
    • /
    • pp.59-67
    • /
    • 1986
  • This sanitary survey was carried out to investigate the bacteriological contamination of cooking utensils and foods of moving tavern in eight sample sites of Seoul area. The results of survey were as follows: 1. The counts by means of total bacteria in cooking utensils and food samples by standard plate count method were as follow: $5.6\times10^5$ per gm in dishcloth, $3.1\times10^6$ per ml in dishwater. In food samples, $5.4\times10^5$ per gm in meat was higher than other samples. 2. The average counts total coliform and fecal coliform in samples by MPN method were as follow: $3.4\times10^4$ MPN per 100ml, and $1.3\times10^2$ MPN per 100ml in chopping board, $6.1\times10^4$MPN per gm and $1.0\times10^2$ MPN per gm in dishcloth, $1.8\times10^5$ MPN per 100ml and $6.1\times10^2$ MPN per 100ml in dishwater. In food samples, $3.1\times10^4$MPN per gm and $2.0\times10^2$ MPN per gm in meat was higher than other samples. 3. The counts by means of Pseudomonas in samples by MPN method were as follow: $2.8\times10^3$ MPN per 100ml in chopping board, $4.7\times10^3$ MPN per gm in dishcloth $5.6\times10^3$ MPN per 100ml in dishwater. In food samples, $2.4\times10^3$ MPN per gm in shellfish was higher than other samples. 4. Isolation cases of Food poisoning organisms from samples were as follow: Staphylococci was detected 9 cases $(17.6\%)$ in chopping board, 7 cases $(13.6\%)$ in dishcloth. In food samples, 9 cases $(25.7\%)$ in meat, 1 case $(4\%)$ in fish samples. Salmonella was detected 2 cases $(3.9\%)$ in dishwater, 1 case in meat samples.

  • PDF

Analysis of Pathogenic Microorganism's Contamination and Heavy Metals on Kimchi Cabbage by Cultivation Methods in Korea (재배농법에 따른 국내산 배추의 위해미생물 및 중금속 오염평가)

  • Oh, Soh-Young;Nam, Ki-Woong;Yoon, Deok-Hoon
    • Journal of Food Hygiene and Safety
    • /
    • v.32 no.6
    • /
    • pp.500-506
    • /
    • 2017
  • Kimchi cabbage is one of the four major vegetable crops in Korea. The total annual production of kimchi cabbage, the main material of kimchi, was 20,559 tons in 2015. Kimchi cabbage is one of the majer crops produced by farmers which accounts for about 80% of the total leaf vegetable production in Korea. As the consumption of environmental-friendly agricultural products increases, food safety is one of the major public health concerns. We analyzed the biological hazards of kimchi cabbage produced by two types of cultivation methos such as organic farming and conventional farming using various culture media and microscopy. A total of 432 samples were analysed for presence of sanitary indicator microorganisms (aerobic plate count, coliform count, yeast & mold) and food-borne pathogens (Staphylococcus aureus, environmental Listeria, Bacillus cereus). The population of sanitary indicating microorganisms and food borne pathogens was under 5 Log CFU/g in all tested samples. The results of total microorganism numbers of leaf surface showed a positive correlation to those of soil samples. Additionally, we examined chemical factors such as pesticide residues and heavy metals in soil samples. All tested samples did not shown contamination levels higher than the standard limit.

A Study of Ozone Occurrence Amount by Copy Machine Use in School and Around of School (학교 내.외 복사기 사용에 따른 오존 발생량 연구)

  • Noh Sun-Jin;Jung Kyung-Sick;Seo Seung-Pyo;Son Bu-Soon;Lee Jong-Wha;Lee Che-Won
    • Journal of environmental and Sanitary engineering
    • /
    • v.21 no.1 s.59
    • /
    • pp.58-65
    • /
    • 2006
  • This study is measured in at ozone concentrated places in school and outside of school where places that use copy machine and the others do not use one. Library copy room, Search room, Y-Copy, J-copy, R-shop are the places using copy machines and Search room, K-apt, J-billiard hall are the opposite. The measurement was held three times a day-the morning, the afternoon and the evening-once for each at indoor and outdoor. 8 places were lower than domestic ozone concentration standard(0.06ppm). The indoor ozone concentration average was the highest in Search room of school and was the lowest in Library restroom. The outdoor ozone concentration average was the highest in J-billiard hall.

The Improvement of the Sanitary Production and Distribution Practices for Packaged Meals (Kim Pab) Marketed in Convenience Stores Using Hazard Analysis Critical Control Point (HACCP) system (편의점 판매용 김밥 도시락 생산 및 유통과정의 품질개선을 위한 연구)

  • 곽동경;김성희;박신정;조유선;최은희
    • Journal of Food Hygiene and Safety
    • /
    • v.11 no.3
    • /
    • pp.177-187
    • /
    • 1996
  • Time-temperature relationship and microbiological quality were assessed and critical control points were identified through hazard analysis during the phases of production in two different packaged meals (Dosirak) manufacturing establishments (A, B:Kim Pab). Microbiological tests on foods, equipments and utensils were done according to standard procedures and included total plate count, coliforms and fecal coliforms. The results of the study are summarized as follows : time-temperature control management was needed because time-temperature abuse more than 8 hours at dangerous temperature zone (5-6$0^{\circ}C$) was observed from pre-preperation to distribution phase; Poor sanitary practices of employees were observed in hand washing and using disposable gloves; Microbiological analysis results of equirpments and utensils showed possible cross-contamination risks when foods were contacted with them; Kim Pab needed thorough quality control because it included various mixed ingredients of cooked and uncooked and had many apportunities of cross-contamination either by equipments or hands through whole production processes.

  • PDF