• Title/Summary/Keyword: sandwich method

Search Result 504, Processing Time 0.023 seconds

Diagnostic Value of Serum Cytokeratin 8, 18 and 19 in Lung Cancer (폐암에서 혈중 Cytokeratin 8, 18, 19의 진단적 가치)

  • Choi, Chang Min;Kim, Woo Jin;Oh, Jin Young;Kang, Young Ae;Yoo, Chul Gyu;Lee, Choon Taek;Kim, Young Whan;Han, Sung Koo;Shim, Young-Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.55 no.4
    • /
    • pp.388-394
    • /
    • 2003
  • Background : Monoclonal antibodies directed against well-known epitopes on cytokeratin (CK) 8, 18 and 19 (Monototal) have been used in the development of a new diagnostic tool for lung cancer. In the mid-1990s, CK 19 fragments (Cyfra 21-1) became popular and widely used for such diagnosis. This is the first study specifically designed to compare these two markers. Method : The serum levels of CK 8, 18 and 19 were measured using two-site monoclonal/polyclonal immunoradiometric assay kit in 57 healthy adults and 289 patients who were admitted to Seoul National University Hospital from May to September, 2002. The lung cancer group comprised 129 primary lung cancer patients; 116 with non-small cell lung cancer(NSCLC) and 13 with small cell lung cancer (SCLC). The control group comprised 160 non-malignant pulmonary lung disease patients and 57 healthy adults. A total of 166 twin Monototal and Cyfra 21-1 serum assays were obtained; 76 with lung cancer, 70 with non-malignant pulmonary lung disease and 20 healthy adults. Results : The mean serum value of Monototal was $412.47{\pm}455.45U/L$ in NSCLC, $237.08{\pm}145.15U/L$ in SCLC, $126.54{\pm}95.72U/L$ in non-malignant pulmonary lung disease, and $63.68{\pm}31.66U/L$ in healthy adults. The serum values of the lung cancer groups were significantly higher than those of the control group (p<0.01). Using a cut off value of 188U/L, sensitivity and specificity was 66.4% and 81.9% in NSCLC, and 43.8% and 81.9% in SCLC, respectively. The serum levels of CK 8, 18 and 19 were higher in advanced NSCLC than in early stage disease. Conclusion : The serum levels of CK 8, 18 and 19 may be useful in the diagnosis of NSCLC.

The Utility of Measurement of Plasma N-terminal Pro-brain Natriuretic Peptide in Diagnosis of Pulmonary Hypertension (폐동맥고혈압 진단에 있어 N-terminal Pro-brain Natriuretic Peptide 측정의 유용성)

  • Hahn, Chang Hoon;Kang, Seok Min;Moon, Jin Wook;Cho, Jae Hee;Hwang, Sang Yon;Lee, Jung Min;Park, Moo Suk;Chung, Jae Ho;Kim, Young Sam;Kim, Se Kyu;Chang, Joon;Shim, Won Heum;Kim, Sung Kyu
    • Tuberculosis and Respiratory Diseases
    • /
    • v.56 no.1
    • /
    • pp.67-76
    • /
    • 2004
  • Background : Pulmonary hypertension is a poor prognostic factor in patients with chronic respiratory disease. However, diagnosing pulmonary hypertension is a difficult procedure which often requires an invasive test. Thus new alternative biochemical markers would be useful in clinical field and are in search. We sought to assess the role of plasma N-terminal pro-brain natriuretic peptide(NT-proBNP) in patients with pulmonary hypertension. Method : We measured plasma NT-proBNP level in twenty nine patients suspected for pulmonary hypertension. Pulmonary hypertension was defined as being right ventricular systolic pressure more than 35 mm Hg estimated by Doppler echocardiography. Plasma NT-proBNP level was measured by electrochemiluminescence sandwich immunoassay. Results : The log-transformed values for plasma NT-proBNP levels showed a linear correlation (correlation coefficiency: 0.783, p-value <0.001) with right ventricular systolic pressure. Plasma NT-proBNP levels closely correlated with right ventricular systolic pressure, right ventricular hypertrophy, interventricular septal flattening and right ventricular dilatation. Conclusion : Our results suggest that the measurement of plasma NT-proBNP level is an useful marker of the presence of pulmonary hypertension.

A Study on Facilities Damage Characteristics Caused by Forest Fire in Goseong-Gun (고성산불로 인한 시설물피해특성 연구)

  • Yeom, Chanho;Lee, Si-young;Park, Houngsek;Kwon, Chungeun
    • Journal of the Society of Disaster Information
    • /
    • v.15 no.4
    • /
    • pp.469-478
    • /
    • 2019
  • Purpose: In this studies we examine the facilities damage characteristics caused by forest fire. Therefore, we surveyed damaged facilities from forest fire which was occurred on Goseong-Gun on march 28 in 2019.(damaged areas was 40ha) The types of facilities uses were house, public facility, warehouse and so on. 17 facilities were destroyed. The purpose of this study was to for establishing a disaster safety village in rural areas where damage from a similar type of disaster occurs repeatedly by conducting the consciousness survey targeting at experts and disaster safety officials in a local government. Method: We surveyed meteorological factors(temperature, wind speed, wind direction, humidity) per a minute for analyzing weather condition on Goseong-Gun when forest fire was occurred, spread and extinguished. And we surveyed forest fire risk factors(a slope degree, a slope direction, a geographical feature, a distance between forest and facility, main species, the existence of crown fire ignition, the direction of facility, the main material of building) around 10 damaged facilities. Finally, we analyzed damage pattern of facilities using meteorological factor and forest fire reisk fator Result: The weather condition of Kanseonng AWS (No.517) was high temperature, arid and strong wind, when the forest fire was occurred and spread. An average wind speed was 4.1m/s and the maximum wind speed was 11.6m/s. The main direction of wind was W(225~315°). Damaged facilities were located on the steep slope area and on the mountaintop. The forest density around facilities was high and main species was korean red pine. The crown fire was occurred in the forest around damaged facilities. The average distance was 13.5m from forest to facilities. When the main matarial of building was made by fire resistance materials (for example, rainforced concrete), the damage was slightly. on the other hand, when by flammable material (for example, a Sandwich Panel), the facilities were totally destroyed Conclusion: The results of this research which were the thinning around house, making a safety distance, the improvement of main material of building and etc, will be helpful for establishing a counter measure for a forest fire prevention of facilities in wild land urban interface

Diagnostic Usefulness of Serum Level of Cyfra 21-1, SCC Antigen and CEA in Lung Cancer (폐암에서 혈중 Cyfra 21-1, SCC 항원 및 CEA의 진단적 유용성)

  • Kim, Kyoung-Ah;Lee, Me-Hwa;Koh, Youn-Suck;Kim, Seon-Hee;Lim, Chae-Man;Lee, Sang-Do;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong;Moon, Dae-Hyuk
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.6
    • /
    • pp.846-854
    • /
    • 1995
  • Background: Cytokeratin 19 is a subunit of cytokeratin intermediate filament expressed in simple epithelia such as respiratory epithelial cells and their malignant counterparts. An immunoradiometric assay is available to detect a fragment of the cytokeratin, referred to as Cyfra 21-1 in the serum. This study was conducted to evaluate the clinical utility of this new marker in the diagnosis of lung cancer compared with established markers of squamous cell carcinoma antigen (SCC Ag) and carcino-embryonic antigen(CEA). In addition, we compared the diagnostic sensitivity and specificity of Cyfra 21-1 with those of SCC Ag in squamous cell carcinoma of the lung. We also measured the level of Cyfra 21-1 in the different stages of squamous cell carcinoma of the lung. Method: We measured Cyfra 21-1(ELSA-CYFRA 21-1), SCC Ag(ABBOTT SCC RIABEAD) and CEA(ELSA2-CEA) in 79 patients with primary lung cancer and in 78 persons as a comparison group including 32 patients with pulmonary tuberculosis, 23 patients with benign lung disease and 23 cases with healthy individual. Cyfra 21-1 is measured by a solid-phase immunoradiometric assay(CIS Bio International, France) based on the two-site sandwich method. SCC Ag is measured by a radioimmunoassay(Abbott Laboratories, USA). CEA is measured by a immunoradiometric assay(CIS Bio International, France). All data were expressed as the mean$\pm$standard deviation. Results: 1) The mean value of Cyfra 21-1 was $18.38{\pm}3.65\;ng/mL$ in the lung cancer and $1.l6{\pm}0.53\;ng/mL$ in the comparison group(p<0.0001). SCC Ag was $3.53{\pm}6.06\;ng/mL$ in the lung cancer and $1.19{\pm}0.5\;ng/mL$ in the comparison group(p<0.01). CEA was $35.03{\pm}13.9\;ng/mL$ in the lung cancer and $2.89{\pm}1.01\;ng/mL$ in the comparison group(p<0.0001). 2) Cyfra 21-1 level in squamous cell carcinoma($31.52{\pm}40.13\;ng/mL$) was higher than that in adenocarcinoma($2.41{\pm}1.34\;ng/mL$)(p<0.0001) and small cell carcinoma($2.15{\pm}2.05\;ng/mL$)(p=0.007). SCC Ag level in squamous cell carcinoma($5.1{\pm}7.68\;ng/mL$) was higher than that in adenocarcinoma($1.36{\pm}0.69\;ng/mL$)(p=0.009) and small cell carcinoma($1.1{\pm}0.24\;ng/mL$) (p=0.024). 3) The level of Cyfra 21-1 was not correlated with the progression of stage in squamous cell carcinoma of the lung. 4) Using the cut-off value of 3.3ng/mL, the diagnostic sensitivity of Cyfra 21-1 was 83% in squamous cell carcinoma, 22% in adenocarcinoma and 17% in small cell carcinoma. The sensitivity of SCC Ag and CEA were 39% and 20%, respectively in squamous cell carcinoma, 11% and 39% in adenocarcinoma, and 0% and 33% in small cell carcinoma. 5) Comparison of the receiver operating characteristics curves(ROC curve) for Cyfra 21-1, SCC Ag and CEA revealed that Cyfra 21-1 showed highest diagnostic sensitivity among them in the diagnosis of lung cancer. Conclusion: Cyfra 21-1 is thought to be a better tumor marker for the diagnosis of lung cancer than SCC Ag and CEA, especially in squamous cell carcinoma of the lung.

  • PDF