• 제목/요약/키워드: sand permeability

Search Result 248, Processing Time 0.026 seconds

IP Characteristics of Sand and Silt for Investigating the Alluvium Aquifer (충적대수층 조사를 위한 모래와 점토의 유도분극 특성 고찰)

  • Choi, Sang-Hyuk;Kim, Hyoung-Soo;Kim, Ji-Soo
    • The Journal of Engineering Geology
    • /
    • v.18 no.4
    • /
    • pp.423-431
    • /
    • 2008
  • In general, water-saturated silt or clay alluvium is characterized with relatively low-resistivity. Thus we often encountered the problem that such a low-resistivity layer is misguided to be good aquifer of high-permeability and low-resistivity in the development of groundwater. This research was conducted with an emphasis on the identification of saturated silt or clay layer from the aquifer by performing the laboratory experiment of IP and resistivity methods on the various materials consisting of alluvium aquifer. Silt or clay layer is found to be characterized with the higher chargeability zone, compared to the sand layer. Regarding the mixture of sand and clay, the higher clay volume, the lower resistivity and the higher chargeability. Subsequently chargeability decreases.

Applicability of Recycled Soil Mixed with Bentonite-Polymer for Waste Landfill Liner (순환토사의 벤토나이트-폴리머 혼합비에 따른 매립지 차수재 적용성에 관한 연구)

  • Shin, Eun Chul;Lee, Hee Mun
    • Journal of the Korean Geosynthetics Society
    • /
    • v.18 no.4
    • /
    • pp.63-73
    • /
    • 2019
  • In this study, it was studied recycled soils with bentonite-polymer mixture in order to design economic landfill instead of clay liner. Recycled soil was used as SP, a sandy soil with 90.58% sand and 1.88% silt and clay. The recycled soils were mixed with 4%, 6%, and 8% bentonite by weight, and then compared with samples mixed with 2%, 3%, and 4% bentonite by weight in marine clay. Recycled soil satisfied the permeability criteria at 8%, and clay soil satisfied at 3%. In order to make a sample that satisfies the standard of the waste landfill, a permeability test was conducted by mixing 0.16%, 0.24%, and 0.28% of the polymer in a sample having 4% bentonite mixing ratio. The unconfined compression strength test was carried out at the same mixing ratio to confirm that the specification was satisfied. As the bentonite mixture ratio increased, the permeability coefficient and unconfined compression strength decreased. The strength in polymer mixing increased initially and then maintained a constant value. At 4% bentonite mixing ratio and 0.28% polymer mixing ratio, the coefficient of permeability was 1.0×10-7 cm/sec or less, and the unconfined compression strength was over 500 kPa. It was confirmed that it can be used as a mixed liner material of waste landfills.

Characteristics of the Smear Zone by Vertical Drain of Low Plasticity on Soft Ground (저소성 연약지반에서의 스미어 존 특성 평가)

  • Kang, Yun;Baek, Sungchul;Kim, Hongtaek
    • Journal of the Korean GEO-environmental Society
    • /
    • v.8 no.3
    • /
    • pp.27-33
    • /
    • 2007
  • The vertical drain method recently being used in Korea is one of the popular soft ground improvement methods, and it is divided into the sand drain method, the pack drain method, the paper drain method, and the PBD method according to the drainage. However, these methods generate the disturbed zone called the smear zone when the drainage is penetrated into the in-situ ground. The characteristics of the smear zone generated cause the problems that the coefficient of permeability decreases, and then the consolidation time in the design becomes longer than expected. Even though the coefficient of horizontal consolidation and the coefficient of permeability in the smear zone are very important design factors directly influencing the degree of consolidation, in the existing studies, these coefficients have been empirically derived by the coefficient of vertical consolidation and used for the design. However, in case that these coefficients derived by the coefficient of vertical consolidation are applied to the actual design, a loss of the duration of construction and a loss of economical efficiency can be happened because of the inaccuracy of the coefficient of horizontal consolidation and the coefficient of permeability. Hence, in this study, in order to understand such influence, the laboratory test was carried out so as to reasonably determine the coefficient of permeability and the coefficient of consolidation in diverse ground conditions. Then, the range of smear effect on clay and silt was estimated with monitoring data through the laboratory test.

  • PDF

The Characteristics of Hydrogeological Parameters of Unconsolidated Sediments in the Nakdong River Delta of Busan City, Korea

  • Khakimov, Elyorbek;Chung, Sang Yong;Senapathi, Venkatramanan;Elzain, Hussam Eldin;Son, JooHyeong
    • Journal of Soil and Groundwater Environment
    • /
    • v.22 no.3
    • /
    • pp.27-41
    • /
    • 2017
  • This study dealt with the characteristics and the interrelations of hydrogeological parameters such as hydraulic conductivity, dispersivity and effective porosity of unconsolidated sediments for providing the basic data necessary for the planning of the management and preservation of groundwater quality in the Nakdong River Delta of Busan City, Korea. Groundwater quality in this area has been deteriorated due to seawater intrusion, agricultural fertilizer and pesticide, industrial wastewater, and contaminated river water. The physical properties (grain size distribution, sediment type, sorting) and aquifer parameters (hydraulic conductivity, effective porosity, longitudinal dispersivity) were determined from grain size analysis, laboratory permeability test and column tracer test. Among 36 samples, there were 18 Sand (S), 7 Gravelly Sand (gS), 5 Silty Sand (zS), 5 Muddy Sand (mS), and 1 Sandy Silt (sZ). Hydraulic conductivity was determined through a falling head test, and ranged from $9.2{\times}10^{-5}$ to $2.9{\times}10^{-2}cm/sec$ (0.08 to 25.6 m/day). From breakthrough curves, dispersivity was calculated to be 0.35~3.92 cm. Also, effective porosity and average linear velocity were obtained through the column tracer test, and their values were 0.04~0.46 and 1.06E-04~6.49E-02 cm/sec, respectively. Statistical methods were used to understand the interrelations among aquifer parameters of hydraulic conductivity, effective porosity and dispersivity. The relation between dispersivity and hydraulic conductivity or effective porosity considered the sample length, because dispersivity was affected by experimental scale. The relations between dispersivity and hydraulic conductivity or effective porosity were all in inverse proportion for all long and short samples. The reason was because dispersivity was in inverse proportion to the groundwater velocity in case of steady hydrodynamic dispersion coefficient, and groundwater velocity was in proportion to the hydraulic conductivity or effective porosity. This study also elucidated that longitudinal dispersivity was dependent on the scale of column tracer test, and all hydrogeological parameters were low to high values due to the sand quantity of sediments. It is expected that the hydrogeological parameter data of sediments will be very useful for the planning of groundwater management and preservation in the Nakdong River Delta of Busan City, Korea.

Evaluation of Mechanical Characteristics and Concentration Target Layer Applicability of Silty Sand by Fines Content (실트질 모래의 세립분 함유율에 따른 역학적 특성 및 압밀 대상층 적용성 평가)

  • Jung-Meyon Kim;Min-Seo Kang;Jong-Joo Kim;Seung-Joo Lee;Young-Seok Kim;Chan-Young, Park;Yong-Seong, Kim
    • Journal of the Korean Geosynthetics Society
    • /
    • v.22 no.3
    • /
    • pp.37-46
    • /
    • 2023
  • In this paper, the physical properties, stress deformation and strength characteristics, density and permeability characteristics of silty sand (SM) by fines content were analyzed through indoor tests. also based on the results of the indoor tests, a compact analysis was performed according to the content of SM, and the applicability of SM ground to the compacted target layer was evaluated by comparing it with the measurement data of the actual problem site. As a result of indoor tests and compression analysis, SM changed its mechanical properties from sandy soil to viscous soil when the fine particle content was 35% or higher, and using field measurement data, SM was found to have a higher compression tendency than direct subsidence. Therefore, the mechanical characteristics of SM above Fc 35% are considered to be similar to that of viscous soil, which is different from the compression characteristics of the tendency of immediate subsidence to conventional sandy soil, so it is necessary to present the mechanical characteristics of SM through further research. The research findings highlight the importance of considering consolidation settlement in silty sand (SM) when evaluating soft soil conditions. These findings can aid in revising criteria for assessing weak ground conditions by providing essential engineering property data based on varying fines content in silty sand.

Effect of Fly Ash Application on the Saturated Hydraulic Conductivity of Soils with Different Soil Texture (석탄회(Fly ash) 처리가 토성(土性)이 다른 토양의 포화수리전도도(飽和水理傳導度)에 미치는 영향)

  • Kim, Jai-Joung;Hong, Soon-Dal
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.32 no.3
    • /
    • pp.279-284
    • /
    • 1999
  • Fly ash is the fine ash particles that are flying out of chimney of the thermoelectric power plant where coals are used as fuel. There are two kinds of fly ashes from anthracite and bituminous coal. By scanning electron microscope(SEM) morphological feature of fly ash was confirmed to the exact spherical particles with the diameter variation from the fine to the largest about $50{\mu}m$(mainly silty particle). Surface of anthracite ash particle was very smooth but that of bituminous was somewhat coarse. To find the utilization of fly ash for improving soil permeability, soils of 4 kinds of different texture, clay, clay loam, sandy clay loam and sand mere applied with 7 levels of fly ash: 0, 10, 20, 40, 60, 80, 100%(w/w) and their saturated hydraulic conductivity(Ks) were determined at each application by constant head method. In clay soil with low water permeability, Ks value was increased about 10 times from $10^{-8}$ to $10^{-7}m\;s^{-1}$ level with application of 10% fly ash and it was slightly increased with increasing fly ash application from 40 to 80%. In clay loam Ks value was about $10^{-7}m\;s^{-1}$ level and its value was not influenced by the fly ash application. In sandy clay loam with relatively high permeability, Ks value was decreased about 10 times from $10^{-5}$ to $10^{-6}m\;s^{-1}$ level with application of 10% fly ash and also decreased about 50 times from $10^{-5}$ to $5.0{\times}10^{-7}m\;s^{-1}$ with application of more than 20% fly ash. In sand with very high permeability, Ks value was decreased about 10 times from $10^{-4}$ to $10^{-5}m\;s^{-1}$ level with application of 10% fly ash and also decreased about 100 times from $10^{-4}$ to $10^{-6}m\;s^{-1}$ level with application of 20% fly ash and continuously decreased about 500 times from $10^{-4}$ to $5.0{\times}10^{-7}m\;s^{-1}$ level with application of more than 40% fly ash. In conclusion by fly ash application saturated hydraulic conductivity was increased in clay soil, on the contrary it was decreased in sandy soils. Fly ash may be used as a material for amelioration of soil permeability.

  • PDF

An Experimental Study on the Replacement Proportion of Recycled Aggregate Effecting in the Engineering Properties of Recycled Concrete (Part 1, Experimental Program and Fluidity Performance of Fresh Concrete (재생골재콘크리트의 공학적 특성에 미치는 재생골재 혼합조건의 영향에 관한 실험적 연구 (제 1보, 실험계획 및 아직 굳지 않은 유동화 특성을 중심으로 ))

  • 최진성;윤병수;임정수;심진만;남상일;김무한
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1993.04a
    • /
    • pp.16-21
    • /
    • 1993
  • The study of recycled aggregate concrete in which demolition waste is utilized to produce aggregate for new concrete, can contribute to the solution of two problems. The first is the shortage of aggregate from river, and the second is the waste disposal problem. In comparison with natural aggregate concrete, recycled aggregate concrete shows reductions in compressive strength, tensile strength , vending strength, shear strength and increases in drying shrinkage and creep. Recycled aggregate concrete may also be less durable due to increase in porosity and permeability. Therefore, the purpose of this study is to analyze the applicability of recycled concrete in the influence of a substitute ratio of recycled sand gravel.

  • PDF

Development of Geotube for Practical Use (지오튜브공법의 실용화방안에 관한 연구)

  • 신은철;오영인;이희재
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.03b
    • /
    • pp.504-511
    • /
    • 2000
  • Geotube is a tube made of permeable but soil-tight geotextile, hydraulically filled with soil include dredged sand and mud, which has been successfully applied in hydraulic and coastal engineering projects. This method is getting popular and used a lot in the advanced countries of the world because of economical, useful, and enable to store and isolate contaminated materials as obtained by harbor dredging. Laboratory and pilot scale in-situ tests were performed to determine the design methodology and construction procedures. From the results of laboratory and in-situ model tests, the retention ratio of solid particle is minimum 86% and minimum permeability and tensile strength of geotextile is ${\alpha}$${\times}$10$\^$-2/ and 20 t/m, respectively. Also, based on the environmental model test results, it can be concluded that this method does meet the Korean EPA standards.

  • PDF

Failure Predict of Standard Sand Model Slope using Compact Rainfall Simulation (소형 인공강우 장치에 의한 표준사 모형사면의 붕괴 예측)

  • Moon, Hyo Jong;Kim, Dae Hong;Jeong, Ji Su;Lee, Seung Ho
    • Journal of Korean Society of Disaster and Security
    • /
    • v.8 no.2
    • /
    • pp.21-26
    • /
    • 2015
  • This study analyzes the failure predict of model slope due to changes in ground condition followed by heavy rainfall with a simulated rainfall system. the movement of a slope from the rainfall penetrating the unsaturated soil is investigated with respect to various conditions of pore-water pressure, earth pressure and moisture content, considering rainfall duration and permeability.

초음파동전기세척 복합기법에 의한 오염부지 복원기술

  • 정하익;김상근;송봉준;강동우;이경국
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.04a
    • /
    • pp.183-185
    • /
    • 2004
  • In this study, the combined electrokinetic and ultrasonic remediation technique, ultrasonically enhanced electrokinetic technique, was studied for the removal of heavy metal and organic substance in contaminated soils. The electrokinetic technique has been applied to remove mainly the heavy metal and the ultrasonic technique has been to remove mainly organic substance in contaminated soil. The laboratory soil flushing tests combined electrokinetic and ultrasonic technique were conducted using specially designed and fabricated devices to determine the effect of these both techniques. A series of laboratory experiments involving the simple, electrokinetic, ultrasonic, and electrokinetic & ultrasonic flushing test were carried out. A soil admixed with sand and kaolin was used as a test specimen, and Pb and ethylene glycol were used as contaminants of heavy metal and organic substance. An increase in out flow, permeability and contaminant removal rate was observed in electrokinetic and ultrasonic flushing tests. Some practical implications of these results are discussed in terms of technical feasibility of in situ implementation of electrokinetic ultrasonic remediation technique.

  • PDF