• Title/Summary/Keyword: sand bed uniformity

Search Result 4, Processing Time 0.02 seconds

Assessment of portable traveling pluviator to prepare reconstituted sand specimens

  • Dave, Trudeep N.;Dasaka, S.M.
    • Geomechanics and Engineering
    • /
    • v.4 no.2
    • /
    • pp.79-90
    • /
    • 2012
  • Air pluviation method is widely adopted for preparation of large, uniform and repeatable sand beds of desired densities for laboratory studies to simulate in-situ conditions and obtain test results which are highly reliable. This paper presents details of a portable traveling pluviator recently developed for model sand bed preparation. The pluviator essentially consisted of a hopper, orifice plates for varying deposition intensity, combination of flexible and rigid tubes for smooth travel of material, and a set of diffuser sieves to obtain uniformity of pluviated sand bed. It was observed that sand beds of lower relative density can be achieved by controlling height of fall, whereas, denser sand beds could be obtained by controlling deposition intensity. Uniformity of pluviated sand beds was evaluated using cone penetration test and at lower relative densities minor variation in density was observed with depth. With increase in relative density of sand bed higher repeatability of uniform pluviation was achieved.

A column study of effect of filter media on the performance of sand filter

  • Kim, Tae-hoon;Oh, Heekyong;Eom, Jungyeol;Park, ChulHwi
    • Membrane and Water Treatment
    • /
    • v.11 no.4
    • /
    • pp.247-255
    • /
    • 2020
  • Sand filter is a key unit process for particle removal in water purification treatments. Its long-standing use is due to on-site customized retrofit. Proper selection of filter media is one of the retrofit approaches to improve filter performance. This study described a series of controlled laboratory column tests and examined the effects of media property on filtration and backwash. When sand media of 0.51 mm in effective size was replaced by sand of 0.60 mm, the filter run increased up to 5 times in the given bed depth. The change of media property required an increase of backwash rate by 0.05 m/min to satisfy the requirement of bed expansion, more than 20%. When the anthracite was changed with lower effective size and uniformity coefficient, correlation with sand in the filter bed could be satisfied within the permissible error between media and bulk characteristics. Besides, this selection resulted in a well-stratified configuration of media layers after bed expansion. The column study showed that the correlation of property between the dual media had a significant effect on the filter productivity and backwash interval.

Hydraulic Assessment about Correlation of Fluvial Movement and River Bed Form on the Narrow Pass of Channel (하천 협소부에서 하상 이동성과 형태와의 상관성에 관한 하도수리학적 평가)

  • Choi, Ho-Kyun;Kim, Won-Il;Lee, Sam-Hee;Ahn, Won-Sik
    • Journal of Korea Water Resources Association
    • /
    • v.42 no.2
    • /
    • pp.141-148
    • /
    • 2009
  • Each river in each country has peculiar channel characteristics at every section. Korea consists of mountains at the rate of 70%. Due to this, the sections that display unique channel form are scattered. One of the typical features is the narrow pass of channel section that presents in the process of the generation of alluvial channel and deformation channel. Around as this narrow pass of channel, it often comes to be regular flood disaster section. Regardless of this situation, investigations and plans that reflect channel characteristics at the narrow pass of channel have been wholly wanting until now. In accordance with this, we have investigated and analysed hydraulic significance and channel form of the narrow pass of channel in Seonsan in this study. The study has found real minute classification of sediment phenomenon at river bed of low flow channel on investigation section which is sand-bed river, but it was vaguely difficult to conclude that classification of sediment arises from explicit natural force. We were able to assume that the phenomenon comes from gentle bed slope, supply of river bed materials which is nearly uniformity. However, classification of sediment would come from collecting an aggregate rather than natural force. And we found that compound cross section conversion has been developing dramatically with channel form of movable bed section referring to movement which was active before at drainage district of the narrow pass of channel. With this, we could find the phenomenon that river width of low flow channel diminished largely. This kind of situation implies that it may cause compound section weighting, flood dimension decreasing, revetment at low flow channel or the local scour at bottom of levee when extraordinary flood occurs.

Study on Electrical Resistivity Pattern of Soil Moisture Content with Model Experiments (토양의 함수율에 따른 전기비저항 반응 모형 실험 연구)

  • Ji, Yoonsoo;Oh, Seokhoon;Lee, Heui Soon
    • Geophysics and Geophysical Exploration
    • /
    • v.16 no.2
    • /
    • pp.79-90
    • /
    • 2013
  • Geophysical investigation in non-destructive testing is economically less expensive than boring testing and providing geotechnical information over wide-area. But, it provides only limited geotechnical information, which is hardly used to the design. Accordingly, we performed electrical resistivity experiments on large scale of soil model to analyze the correlation between electrical resistivity response and soil water contents. The soils used in the experiments were the Jumunjin standard sand and weathered granite soil. Each soil particle size distribution and coefficient of uniformity of experimental material obtained in the experiments were maintained in a state of the homogeneous. The specifications of the model used in this study is $160{\times}100{\times}50$(cm) of acrylic, and each soil was maintained at the height 30 cm. The water content were measured using the 5TE sensors (water contents sensors) which is installed 7 ~ 8 cm apart vertically by plugging to floor. The results of the resistivity behavior pattern for Jumunjin standard sand was found to be sensitive to the water content, while the weathered granite soil was showing lower resistivity over the time, and there was no significant change in behavior pattern observed. So, it results that the Jumunjin standard sand's particle current conduction was better than the weathered granite soil's particle through contact with the distilled water. This lab test was also compared with the result of a test bed site composed of similar weathered soil. It was confirmed that these experiments were underlying research of non-destructive investigation techniques to improve the accuracy to estimate the geotechnical parameter.