• Title/Summary/Keyword: sampling section

Search Result 132, Processing Time 0.023 seconds

Efficient Auto Measure Sampling Method for Semiconductor Line (반도체 라인의 효율적 계측을 위한 자동 계측 샘플링 방식에 관한 연구)

  • Kim, Tae-Yeob;Sun, Dong-Seok;Lee, Jee-Hyung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.12
    • /
    • pp.2505-2510
    • /
    • 2009
  • Semiconductor processes need measurement to confirm where there are problems in quality after progresses manufacturing process. This paper suggests equipment and automatic measure sampling method that control monitoring ratio according to change point occurrence availability of process that is not measure method by the existent simple ratio rate. This paper defines measure section as ailment section, metastable section and stability section by change point standard and create statistical model of each section and developed suitable measure rate model by section. As a result, we have accomplished maximum throughput and minimum sampling number that needs to maintain constant level of quality. Proposed method minimizes load of measure process by brings production quality sophistication and decrease of process badness and lowers measure rate in stable section making perception about problem occurrence quick heightening measure rate at change point occurrence.

Influence Analysis of Sampling Points on Accuracy of Storage Reliability Estimation for One-shot Systems (원샷 시스템의 저장 신뢰성 추정 정확성에 대한 샘플링 시점의 영향 분석)

  • Chung, Yong H.;Oh, Bong S.;Lee, Hong C.;Park, Hee N.;Jang, Joong S.;Park, Sang C.
    • Journal of Applied Reliability
    • /
    • v.16 no.1
    • /
    • pp.32-40
    • /
    • 2016
  • Purpose: The purpose of this study is to analyze the effect of sampling points on accuracy of storage reliability estimation for one-shot systems by assuming a weibull distribution as a storage reliability distribution. Also propose method for determining of sampling points for increase the accuracy of reliability estimation. Methods: Weibull distribution was divided into three sections for confirming the possible to estimate the parameters of the weibull distribution only some section's sample. Generate quantal response data for failure data. And performed parameter estimation with quantal response data. Results: If reduce sample point interval of 1 section, increase the accuracy of reliability estimation although sampling only section 1. Even reduce total number of sampling point, reducing sampling time interval of the 1 zone improve the accuracy of reliability estimation. Conclusion: Method to increase the accuracy of reliability estimation is increasing number of sampling and the sampling points. But apply this method to One-shot system is difficult because test cost of one-shot system is expensive. So propose method of accuracy of storage reliability estimation of one-shot system by adjustment of the sampling point. And by dividing the section it could reduce the total sampling point.

Effect of sampling volume on the breakthrough of charcoal tube during vinyl chloride monomer sampling (공기중 염화비닐단량체의 포집시 공기 포집량이 파과에 미치는 영향)

  • Yoon, Jon Jung;Lim, Nam Gu;Kim, Chi Nyun;Roh, Jaehoon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.11 no.3
    • /
    • pp.241-248
    • /
    • 2001
  • The main factors of breakthrough are known to sampling time, flow rate, concentration of the sample, temperature, humidity, and the physical characteristics of the solid sorbent tube. However, no study has been reported the effect of temperature and sampling volume on the breakthrough of acharcoal tube during vinyl chloride monomer (VCM) sampling. The objective of this study is to suggest the optimal sampling condition during VCM sampling based on National Institute for Occupational Safety and Health (NIOSH) method. To evaluate adequate sampling volume for VCM without breakthrough, volume of 1, 2, 3, 4, and 5 L each from VCM of 1, 5, 10, 15, and 20ppm at flow rate of 0.05 L/min were sampled in $22^{\circ}C$ and $40^{\circ}C$. At $22^{\circ}C$, in the case of 1, 5, 10, and 15ppm, VCM was adsorbed completely in first section of charcoal tube regardless of sampling volume. But in 20ppm, detection rates are 99.56% in first section and 0.44% in second section. At $40^{\circ}C$ of 1ppm, VCM was adsorbed completely in first section. In 10, 15, and 20ppm, detection rates of second, third, and forth sections were decreased significantly by reduction of sampling volume. In determination of breakthrough based on NIOSH method, no breakthrough was occurred in 20ppm at $22^{\circ}C$. At $40^{\circ}C$, breakthrough was occurred in 10, 15, and 20ppm when sampling volume was 5L. Although no breakthrough was occurred when sampling volume was 3L. Finally, in environment of temperature around $22^{\circ}C$, breakthrough may not occurred up to 20ppm during sampling for VCM. During sampling for VCM in environment of temperature around $40^{\circ}C$, no breakthrough occurred in 1-5ppm and 10-20ppm when sampling volume is 5L and 3L respectively. This result suggests that the sampling volume should be considered when VCM sampling under hot conditions (> $22^{\circ}C$) by the NIOSH method No. 1007.

  • PDF

Evaluation of the Charcoal Tube Sampling Method for Carbon Disulfide in Air (활성탄관법을 이용한 공기중 이황화탄소 농도 측정법에 관한 연구)

  • Lee, Na Roo;Paik, Nam Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.3 no.1
    • /
    • pp.22-36
    • /
    • 1993
  • This study was conducted to evaluate the charcoal tube sampling method for carbon disulfide in the air. Breakthrough was investigated according to flow rate, sampling time and air volume. Also the storage stability by storage method and time was investigated. The results are summarized as follows. 1. The samples stored at room temperature($28.2^{\circ}C$), refrigerator($3.8^{\circ}C$) and freezer($-15.6^{\circ}C$) were analyzed every week to five weeks. At one week storage at room temperature, 3.5% of $CS_2$ in the front section of the charcoal tube migrated into the back section and 57.7% at five weeks. The amount of $CS_2$ in the back section of the charcoal increased continuously by storage time. Migration of $CS_2$ was slow at refrigerator, and stopped occur at freezer. Recovery rate $CS_2$ was 52-82% at room temperature and 92-101% at refrigerator, based on the amount at freezer as a reference value. Thus loss was observed at room temperature. 2. When 6-48 L of fresh air were passed through tubes with spiked amounts of 0.379 and 0.759mg sample, the amounts of $CS_2$ in the back section of charcoal were 5.7-132.4 and 0-92% of the amount in the front section, respectively. The total recovery rates of$CS_2$ from 0.379 and 0.759mg spiked sample were 35.7-101.0% and 9l.3-100.1%, respectively. $CS_2$ loss was observed in 0.379mg spiked sample, but not in 0.759mg spiked sample. In the spiked samples, the amount of $CS_2$ in the back section of charcoal was not affected by flow rate when the air volume was controlled. The amount of $CS_2$ in the back section of charcoal increased over sampling time. And the faster the flow rate, the more the migration amount when the sampling time was the same. 3. A known concentration, 10 ppm of $CS_2$, was produced in a 200 L Tedlar bag. When the air volume was 24, 36, 48 L, breakthrough was 5.8, 16.9, 47.4%, respectively. The sampling flow rate of 0.05, 0.1, 0.2 Lpm did not change the breakthrough rate. Breakthrough increased over sampling time. And the faster the flow rate, the more the breakthrough, when the sampling time was the same.

  • PDF

McCARD/MIG stochastic sampling calculations for nuclear cross section sensitivity and uncertainty analysis

  • Ho Jin Park
    • Nuclear Engineering and Technology
    • /
    • v.54 no.11
    • /
    • pp.4272-4279
    • /
    • 2022
  • In this study, a cross section stochastic sampling (S.S.) capability is implemented into both the McCARD continuous energy Monte Carlo code and MIG multiple-correlated data sampling code. The ENDF/B-VII.1 covariance data based 30 group cross section sets and the SCALE6 covariance data based 44 group cross section sets are sampled by the MIG code. Through various uncertainty quantification (UQ) benchmark calculations, the McCARD/MIG results are verified to be consistent with the McCARD stand-alone sensitivity/uncertainty (S/U) results and the XSUSA S.S. results. UQ analyses for Three Mile Island Unit 1, Peach Bottom Unit 2, and Kozloduy-6 fuel pin problems are conducted to provide the uncertainties of keff and microscopic and macroscopic cross sections by the McCARD/MIG code system. Moreover, the SNU S/U formulations for uncertainty propagation in a MC depletion analysis are validated through a comparison with the McCARD/MIG S.S. results for the UAM Exercise I-1b burnup benchmark. It is therefore concluded that the SNU formulation based on the S/U method has the capability to accurately estimate the uncertainty propagation in a MC depletion analysis.

Establishment of DeCART/MIG stochastic sampling code system and Application to UAM and BEAVRS benchmarks

  • Ho Jin Park;Jin Young Cho
    • Nuclear Engineering and Technology
    • /
    • v.55 no.4
    • /
    • pp.1563-1570
    • /
    • 2023
  • In this study, a DeCART/MIG uncertainty quantification (UQ) analysis code system with a multicorrelated cross section stochastic sampling (S.S.) module was established and verified through the UAM (Uncertainty Analysis in Modeling) and the BEAVRS (Benchmark for Evaluation And Validation of Reactor Simulations) benchmark calculations. For the S.S. calculations, a sample of 500 DeCART multigroup cross section sets for two major actinides, i.e., 235U and 238U, were generated by the MIG code and covariance data from the ENDF/B-VII.1 evaluated nuclear data library. In the three pin problems (i.e. TMI-1, PB2, and Koz-6) from the UAM benchmark, the uncertainties in kinf by the DeCART/MIG S.S. calculations agreed very well with the sensitivity and uncertainty (S/U) perturbation results by DeCART/MUSAD and the S/U direct subtraction (S/U-DS) results by the DeCART/MIG. From these results, it was concluded that the multi-group cross section sampling module of the MIG code works correctly and accurately. In the BEAVRS whole benchmark problems, the uncertainties in the control rod bank worth, isothermal temperature coefficient, power distribution, and critical boron concentration due to cross section uncertainties were calculated by the DeCART/MIG code system. Overall, the uncertainties in these design parameters were less than the general design review criteria of a typical pressurized water reactor start-up case. This newly-developed DeCART/MIG UQ analysis code system by the S.S. method can be widely utilized as uncertainty analysis and margin estimation tools for developing and designing new advanced nuclear reactors.

Study on the simulation of contamination route and estimation of the pollution sources of DNOC using a numerical model (수치모형을 이용한 DNOC의 물질 거동 모의와 오염원 추정 연구)

  • Park, Kyeong-Deok;Kim, Il-Kyu
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.1
    • /
    • pp.29-37
    • /
    • 2017
  • To estimate pollution sources in the watershed with various industries, the simulation of contamination route and distribution of 2-methyl-4,6-dinitriophenol(DNOC) were performed with a numerical model Hydro Geo Sphere. This study was performed calculations of the load using the measured concentration and simulated flow rate. And, the river was divided by the sampling sites at the mainstream, and the contribution rate at downstream sampling sites was calculated for each section. The results showed the concentration of the downstream sampling sites were decided by the concentration of upstream sites, and the contribution rates of the tributaries were calculated below 10%. The results also showed that the impact of the potential sources in Section 1(Geumho1 ~ Geumho2) and Section 5(Geumho5 ~ Geumho6) was larger than in the other area. In Section1 and Section5, It seemed to require detailed investigation.

The Volume Measurement of Air Flowing through a Cross-section with PLC Using Trapezoidal Rule Method

  • Calik, Huseyin
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.4
    • /
    • pp.872-878
    • /
    • 2013
  • In industrial control systems, flow measurement is a very important issue. It is frequently needed to calculate how much total fluid or gas flows through a cross-section. Flow volume measurement tools use simple sampling or rectangle methods. Actually, flow volume measurement process is an integration process. For this reason, measurement systems using instantaneous sampling technique cause considerably high errors. In order to make more accurate flow measurement, numerical integration methods should be used. Literally, for numerical integration method, Rectangular, Trapezoidal, Simpson, Romberg and Gaussian Quadrature methods are suggested. Among these methods, trapezoidal rule method is quite easy to calculate and is notably more accurate and contains no restrictive conditions. Therefore, it is especially convenient for the portable flow volume measurement systems. In this study, the volume measurement of air which is flowing through a cross-section is achieved by using PLC ladder diagram. The measurements are done using two different approaches. Trapezoidal rule method is proposed to measure the flow sensor signal to minimize measurement errors due to the classical sampling method as a different approach. It is concluded that the trapezoidal rule method is more effective than the classical sampling.

A Sample Design for National Nutrition Servey (국민영양조사(國民營養調査)를 위한 표본설계(標本設計) 소고(小考))

  • Jun, Tae-Yoon;Chung, Kee-Hey
    • Journal of Nutrition and Health
    • /
    • v.17 no.3
    • /
    • pp.236-241
    • /
    • 1984
  • In order to make clear the relationship between sample design and sample survey in community, it was conducted research on sample design for National Nutrition Survey in 1983. In this paper it was tried to analize the data based on The Report of a Settled Population, 1981 conducted by National Bureau of Statistics Economic Planning Board. The sample was basically using stratified two-stage sampling with systematic sampling of Ban or Li as administrative unit. The population represents the whole nation excluding Jeju-do because of budget. The selection of sampling unit and sampling procedure was as follows. 1) Stratify the nation-wide area in 20 sections according to administrative districts. 2) Determine the sample size in each section according to equal proportional rate (1 / 8040) and to about 1,000 households in the sample. 3) Select the 25 sampling units by section according to households proportion. 4) Select the 10 households at random from each Ban or Li according to equal probability proportion as the final sampling unit. Using the procedure, it was sampled 1,000 households for National Nutrition Survey in 1983.

  • PDF

Which Endometrial Pathologies Need Intraoperative Frozen Sections?

  • Balik, Gulsah;Kagitci, Mehmet;Ustuner, Isik;Akpinar, Funda;Guven, Emine Seda Guvendag
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.10
    • /
    • pp.6121-6125
    • /
    • 2013
  • Background: Endometrial cancers are the most common gynecologic cancers. Endometrial sampling is a preferred procedure for diagnosis of the endometrial pathology. It is performed routinely in many clinics prior to surgery in order to exclude an endometrial malignancy. We aimed to investigate the accuracy of endometrial sampling in the diagnosis of endometrial pathologies and which findings need intra-operative frozen sections. Materials and Methods: Three hundred nine women applying to a university hospital and undergoing endometrial sampling and hysterectomy between 2010 and 2012 were included to this retrospective study. Data were retrieved from patient files and pathology archives. Results: There was 17 patients with malignancy but endometrial sampling could detect this in only 10 of them. The endometrial sampling sensitivity and specificity of detecting cancer were 58.8% and 100%, with negative and positive predictive values of 97.6%, and 100%, respectively. In 7 patients, the endometrial sampling failed to detect malignancy; 4 of these patients had a preoperative diagnosis of complex atypical endometrial hyperplasia and 2 patients had a post-menopausal endometrial polyps and 1 with simple endometrial hyperplasia. Conclusions: There is an increased risk of malignancy in post-menopausal women especially with endometrial polyps and complex atypia hyperplasia. Endometrial sampling is a good choice for the diagnosis of endometrial pathologies. However, the diagnosis should be confirmed by frozen section in patients with post-menopausal endometrial polyps and complex atypia hyperplasia.