• Title/Summary/Keyword: sampler model

Search Result 163, Processing Time 0.027 seconds

Characterization of Wintertime Atmospheric Aerosols in Seoul Using PIXE and Supplementary Analyzers

  • Ma, Chang-Jin;Mikio Kasahara;Hwang, Kyung-Chul;Yeo, Hyun-Gu;Park, Kum-Chan
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.16 no.E
    • /
    • pp.19-27
    • /
    • 2000
  • Particle Induced X-ray Emission (PIXE) and Elemental Analysis Syztem (EAS) were applied to the investiga-tion of the Characteristics and sources of wintertime atmospheric aerosols in Seoul. Atmospheric aerosols were collected by both fine and coarse fractions using a two-stage filter pack sampler from Kon-Kuk university during the winter season of 1999. PIXE was applied to the analysis of the middle and heavy elements with atomic numbers greater than 14(Si) and EAS was applied to the measurement of the light elements such as H, C and N. The fact that 64.2% of mass of fine particles in Seoul consists of the light elements (N, C , and H) suggests that the measurement of light elements is extremely important. The average mass concentration is Seoul was 38.6$\mu\textrm{g}$m(sup)-3. Elements such as Ca, Fe, Mg, and Ti appeared to have very low Fine/Coarse ratios(0.1∼0.4), whereas che-mical components related to anthropogenic sources such as Br, V, Pb, and Zn were observed to accumulate in the fine fraction. In the Asian Dust Storm(ADS) event, the concentation of soil components increased dramatically. Reconstruction of the fine mass concentrations estimated by a newly revised simple model was fairly in good agreement with the measured ones. Source identification was attempted using the enrichment factor and Pearsons coefficient of correlation. The typical elements derived from each source could be classified by this method.

  • PDF

Development of a Receptor Methodology for Quantitative Assessment of Ambient PM-10 Sources in Suwon Area (수원지역 대기 중 PM-10 오염원의 정량평가를 위한 수용방법론의 개발)

  • 김관수;황인조;김동술
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.17 no.2
    • /
    • pp.119-131
    • /
    • 2001
  • A total of 328 ambient PM-10 samples was collected by a PM-10 high volume air sampler during the periods of February 1997 to February 1999 from Kyung Hee University at Suwon Campus. The samples were analyzed for their bulk chemical compositions(Cu, Fe, Pb, Zn, Al, $Na^{+}$, $NH_{4}^{+}$, $K^{+}$, $Ca^{2+]$, $Mg^{2+}$, $Cl^{-}$, $NO_{3}^{-}$, and $SO_{4}^{2-}$ by both an atomic absorption spectrophotometer and an ion chromatograph. The purpose of this study was t develop a receptor methodology for quantitative assessment of PM-10 sources. The data obtained from this study were ex-tensively examined using the target transformation factor analysis(TTFA) and the chemical mass balance (CMB). When TTFA was initially applied seasonal basis. five sources(such as automobile-related, sulfate-related, incine-ration, soil and combustion-related) were identified both during winter and fall. Since the total number and the type of sources were resolved by TTFA for the four seasons, CMB was employed to cross-check the results of TTEA. The total of six source categories identified by TTEA was intensively investigated on the basis of source profiles acquired from various source libraries established both in Korea and abroad. The results of this study showed the applicability of two popular receptor models as a new methdology for quantitative assessment PM-10 sources in Korea. Seasonally segmented data sets with the combined application of TTFA and CMB yielded a physically reasonable source apportionment result and provided a mean to increase the number of potential sources. Furthermore, this study suggested the possibility of the CMB application to ambi-ent data from Korea after identifying potential sources through traditional factor analysis.

  • PDF

Source Identification of PM-10 in Suwon Using the Method of Positive Matrix Factorization (PMF 방법론을 이용한 수원지역 PM-10의 오염원 확인)

  • 황인조;김태오;김동술
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.17 no.2
    • /
    • pp.133-145
    • /
    • 2001
  • The receptor modeling is one of the statistical methods to achieve reasonable air pollution strategies. The pur-pose of this study was to survey the concentration variability oi inorganic elements and ionic species in the PM-10 particles, to qualitatively characterize emission sources by an advanced algorithm called positive matrix factoriza-tion(PMF) as a receptor model that can strictly provide results in every loading matrix. A total of 254 samples was collected by a PM-10 high volume air sampler from Mar. 1997 to Feb. 1998 in Kyung Hee University at Suwon Campus. Fourteen chemical species(Zn, Cu, Fe, Pb, Al, Mn, $Na^{+}$, NH$_4$+, $K^{+}$, $Mg^{2+}$, $Ca^{2+}$, $SO_4^{2-}$, $NO_{3}^{-}$, and $Cl^{-}$) were determined by AAS and IC methods. The study results showed that the average monthly concentration of PM-10 particles were 86.3$\mu\textrm{g}$/$\textrm{m}^3$ in March (maximum) and 28.5$\mu\textrm{g}$/$\textrm{m}^3$ in August(minimum), respectively. The concentrations of Na+, NH$_4$+, $K^{+}$ and $Cl^{-}$ in winter, $Mg^{2+}$, $Ca^{2+}$ and $NO_{3}^{-}$, in spring, and $SO_4^{2-}$ in summer showed the largest peak concentration for the respective season. Through and app-lication of a PMF program of Pm-10 concentration data of Suwon, 9 sources were qualitatively identified , such as incineration source, oil burning source, soil related source, open burning source automobile source, coal burning sources, secondary sulfate related source, and secondary nitrate related source.

  • PDF

A Study for Characteristics of PM10 in the Subway Passenger Cabins (지하철 전동차 객실에서의 PM10 오염특성 파악에 관한 연구)

  • Oh, Mi-Seok;Park, Duck-Shin;Park, Eun-Young
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.27 no.5
    • /
    • pp.523-533
    • /
    • 2011
  • This study had the aim of characteristics of $PM_{10}$ in subway cabins. $PM_{10}$ was measured by times of day (rush and non rush hours) and seasons with real time $PM_{10}$ sampler on the subway cabins of line 7. Filter samples were collected for evaluation of their elemental composition as well as identification of major sources of $PM_{10}$ using a receptor model, PMF. $PM_{10}$ concentration were the highest in the winter season both in the rush and non rush hours at 152.8 ${\mu}g/m^3$, 90.2 ${\mu}g/m^3$ respectively. The $PM_{10}$ concentrations in rush hour were 30% higher compared to non rush hours. Based on the chemical information, the composition rare of inorganic elements was 52.5%, anions were 10.2% and others were 37.3%. Fe was the most abundant element and significantly correlated (p.0.01) with Mn (r=0.97), Ti (r=0.91), Cr (r=0.88), Ni (r=0.89) and Cu (r=0.88). Characterized $PM_{10}$ sources by PMF in the cabin were soil and road dust related sources (27.2%), railroad related sources (47.5%), secondary nitrate sources (16.2%) and a Cl-factor mixed with a secondary sulfate source (9.1%).

Effects of Crustal Species on Characteristics of Aerosols: Simulation of Measurements at Kosan, Cheju Island, 1994 (토양 성분이 입자 특성에 미치는 영향: 제주도 고산에서의 1994년 측정결과 모사)

  • 김용표;문길주
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.12 no.3
    • /
    • pp.289-296
    • /
    • 1996
  • Effects of crustal species on the characteristics of ambient particles were studied by applying a gas-particle equilibrium model, SCAPE, to the measurements at Kosan, Cheju Island during the spring and summer, 1994. Two cases were simulated; the measured composition was used without any modification (case 1), and the metal ion concentrations originated from crust were subtracted from the measured particle composition (case 2). Total suspended particles (TSPs) were collected by an automatic high volume tape sampler during spring period and by high volume samplers during summer period. The fine particles, PM 2.5, and gaseous volatile species were collected using a filter pack smapler during summer period. The water soluble ion concentrations were analyzed from all the particle samples. According to the simulation results, the effect of crustal elements on the chemical composition of particles is negligible for both TSP particles and PM 2.5 particles. Acidity of particles measured at Kosan, however, is affected by the change of the concentrations of crustal species, stronger effects for TSP particles than for PM 2.5 particles during summer, and stronger effects during summer than spring for TSP particle. The average pH decrease due to the absence of crustal species was about 0.10 for PM 2.5 particle during summer and 1.51 and 0.85 for TSP particles during summer spring, respectively. Water contents of PM 2.5 particles for both cases are comparable to each other. Estimated water content of TSP particles for case 2 is higher than that for case 1 by about 4 $\sim 6 \mum/m^3$ because salts of metal ions are not hygroscopic.

  • PDF

A Parametric Image Enhancement Technique for Contrast-Enhanced Ultrasonography (조영증강 의료 초음파 진단에서 파라미터 영상의 개선 기법)

  • Kim, Ho Joon;Gwak, Seong Hoon
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.3 no.6
    • /
    • pp.231-236
    • /
    • 2014
  • The transit time of contrast agents and the parameters of time-intensity curves in ultrasonography are important factors to diagnose various diseases of a digestive organ. We have implemented an automatic parametric imaging method to overcome the difficulty of the diagnosis by naked eyes. However, the micro-bubble noise and the respiratory motions may degrade the reliability of the parameter images. In this paper, we introduce an optimization technique based on MRF(Markov Random Field) model to enhance the quality of the parameter images, and present an image tracking algorithm to compensate the image distortion by respiratory motions. A method to extract the respiration periods from the ultrasound image sequence has been developed. We have implemented the ROI(Region of Interest) tracking algorithm using the dynamic weights and a momentum factor based on these periods. An energy function is defined for the Gibbs sampler of the image enhancement method. Through the experiments using the data to diagnose liver lesions, we have shown that the proposed method improves the quality of the parametric images.

Infrared Spectral Signatures of Dust by Ground-based FT-IR and Space-borne AIRS (지상 및 위성 고분해 적외스펙트럼 센서에서 관측된 황사 특성)

  • Lee, Byung-Il;Sohn, Eun-Ha;Ou, Mi-Lim;Kim, Yoon-Jae
    • Atmosphere
    • /
    • v.19 no.4
    • /
    • pp.319-329
    • /
    • 2009
  • The intensive dust observation experiment has been performed at Korea Global Atmosphere Watch Center (KGAW) in Anmyeon, Korea during each spring season from 2007 to 2009. Downward and upward hyper-spectral spectrums over the dust condition were measured to understand the hyper-spectral properties of Asian dust using both ground-based Fourier Transform Infrared Spectroscopy (FT-IR) and space-borne AIRS/Aqua. To understand the impact of the Asian dust, a Line-by-Line radiative transfer model runs to calculate the high resolution infrared spectrum over the wave number range of $500-500cm^{-1}$. Furthermore, the radiosonde, a $PM_{10}$ Sampler, a Micro Pulse Lidar (MPL), and an Aerodynamic Particle Sizer (APS) are used to understand the vertical profile of temperature and humidity and the properties of Asian dust like concentration, altitude of dust layer, and size distribution. In this study, we found the Asian dust distributed from surface up to 3-4 km and volume concentration is increased at the size range between 2 and $8{\mu}m$ The observed dust spectrums are larger than the calculated clear sky spectrums by 15~60K for downward and lower by around 2~6K for upward in the wave number range of $800-1200cm^{-1}$. For the characteristics of the spectrum during the Asian dust, the downward spectrum is revealed a positive slope for $800-1000cm^{-1}$ region and negative slope over $1100-1200cm^{-1}$ region. In the upward spectrum, slopes are opposed to the downward one. It is inferred that the difference between measured and calculated spectrum is mostly due to the contribution of emission and/or absorption of the dust particles by the aerosol amount, size distribution, altitude, and composition.

Effect of Air-mass Back Trajectory on the Chemical Composition of Cloud/Fog Water at Daegwallyeong (기류의 유입경로가 대관령 지역 안개의 화학조성에 미치는 영향)

  • Kim Man-Goo;Lee Bo-Kyoung;Kim Hyun-Jin;Hong Young-Min
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.3
    • /
    • pp.343-355
    • /
    • 2005
  • Cloud/fog water was collected at Daegwallyeong, a typical clean environmental area, by using an active fog sampler during the foggy period in 2002, The pH ranged from 3,7 to 6,5 with a mean of 5,0, but the pH calculated from average concentrations of $H^+$ was 4.4. $SO_4^{2-},\;NO_3^-\;and\;NH_4^+$ were predominant ions with average concentrations of 473,3, 463,3 and $576,0\;{\mu}eq/L$, respectively, This showed that cloud/fog water was slightly acidified, but the concentrations of major pollutants were as high as those for polluted area, suggesting effect from long range transported pollutants, Samples were categorized into four groups (E, W, S, N) by applying 48-h back trajectory analysis using the Hybrid Single-Particle Largrangian Integrated Trajectory (HYSPLIT) model. Concentrations of seasalt $(Na^+\;and\;Cl^-)$ were the highest for group E, indicating large input of seasalts by air masses transported from the East Sea. The concentrations of $SO_4^{2-}$ were slightly higher in group W but the difference was not significant. However, the concentrations of $NO_3^-$ were significantly higher in group W than those in other three groups, The median values of cloud/fog water pH for group N and W were below 4,5, which is significantly lower than median values in group E and group S, This suggests that the acidifying pollutants were transported from the Asia continents and Seoul metropolitan area cause acidification of the cloud/fog water in Daegwallyeong.

A Preliminary Statistical Stduy of Polycyclic Aromatic Hydrocarbons and Inorganic Elements Data for Extimation Ambient PM-10 Sources -Near the Huge Young-Tong Construction Area during Feb. 1996 to June 1996- (대기 중 PM-10의 오염원 추정을 위한 다환방향족탄화수소와 무기원소자료의 예비통계분석 -1996년 2월~6월까지 대규모 영통건설지역 주변을 중심으로-)

  • 손정화;황인조;김동술
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.16 no.1
    • /
    • pp.11-22
    • /
    • 2000
  • Polycyclic aromatic hydrocarbons(PAHs) have known as potentially hazardous air pollutants(HAPs0 to human health because of its carcinogenic and mutagenic behaviors. The purpose of this study was to determine the level of 6 PAHs(Fluoranthene, Pyrene, Benzo[a]anthracene, Chrysene, Benzo[b]fluoranthene, and Benzo[a]pyrene) as well as 10 inorganic elements(Cr, Na, K, Zn, Pb, Fe, Cu, Ti, Al and Cd) in the ambient PM-10. The total of 115 samples had been collected from February, 1996 to June, 1996 on quartz fiber by a PM-10 high volume air sampler near the Yong-Tong Apartment complexes. A statistical analysis was performed for the PAHs and inorganic elements data set using a principal component analysis in order to identify qualitatively the potential sources of PM-10. A total of 6 principal components were separated by intensive data pretrement and transformation processes, such as soil, refuse incineration, oil burning, coal burning, field burning, vehicle emission sources. The results showed that PAHs were associated with various burning activities like refuse and field burning, coal burning, and oil burning emissions in the study area. These derived sources were well matched with the previously known source profiles in terms of compositonal order and level of measured species. The combination data set consisted of both organic and inorganic species might provide more powerful source signature and might increase the number of potentially derived sources than PAHs or inorganic data alone.

  • PDF

Development of AAS and Determination of metals in airborne particles (원자흡수분광광도계의 제작 및 분진 중 금속성분 분석 비교)

  • Choi, Bae-Jin;Bang, Myung-Sik;Yeo, In-Hyeong
    • Analytical Science and Technology
    • /
    • v.16 no.3
    • /
    • pp.226-231
    • /
    • 2003
  • We analyzed the concentrations of heavy metals associated airbone particles by using AAS made by both a domestic manufacturer and one of the foreign manufacturer. One model developed by a domestic manufacture showed excellent results in the selected wavelength with an excellent performance of a monochromator. It abandons a big drop except a fine drop to improve reproduction in atomizer, so that no remains should leave. Using the low pass filter we were able to reduce a noise of detection signal. The performance of our equipment was found to be highly compatible with that of a foreign company as we achieved the detection limit of about $0.015{\mu}g/L$ using a standard solution of Au. The PM samples had been collected from by main observation points in 7 areas of Seoul city from 2001 to the spring in 2002. with these PM sample we analyzed the concentrations of Pb, Cu, Mn, Cd, Ni, Fe, Cr, Co, Mg and Al.