• 제목/요약/키워드: sampled-measurements

검색결과 123건 처리시간 0.024초

20대 여성의 얼굴유형 분류 및 형태적 특성 연구 (A Study on Women's Face Types Classification and Shape Differences)

  • 송미영;박옥련
    • 패션비즈니스
    • /
    • 제8권1호
    • /
    • pp.76-90
    • /
    • 2004
  • The purpose of this study was to classify women's face types and to analyze the measurement of face types. For study, 180 adult women(aged between 20 and 29) in Pusan and Ulsan area was sampled to be measured for facial types. Data were analyzed by Frequencies, Means, Duncan's Multiple Range Test, Distinction analysis. The major results were as followed. Women's face types were classified by 6 types and there were round shape(29.4%), oblong shape(18.9%), inverted triangle shape(16.1%), square shape(13.9%), egg shape(11.7%), diamond shape(10.0%) in the subject. Phyiognomic facial height was 182.38mm, the upper face length was 59.82mm, the middle face length 60.82mm, the lower face length 61.76mm, and the index of face length to face breadth was 1.35. The face width was 134.90mm, interocular distance 34.75mm, the nose width 33.93mm, and mouth width was 43.87mm. And also, differences from those measurements like forehead breadth, face length/bizygion breadth, forehead slopper, bigonion breadth, bignathion breadth, bignathion slopper.

시간에 따라 변하는 고속철 부하의 고조파 측정, 평가 및 시뮬레이션에 관한 연구 (A Study on the Time-varying Harmonics Measurement, Assessment and Simulation of the High Speed Electric Train Loads)

  • 김경철;진성은;이일무;왕용필;곽노홍;전영수;박상호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.78-80
    • /
    • 2006
  • High speed electric trains have nonlinear loads including converters and inverters for the control synchronous motors. Harmonic field measurements have shown that the harmonic contents of a waveform varies with time. Direct application of the harmonic assessment to the snapshot measurements would result in ambiguous conclusions depending on which instant is sampled. A cumulative probabilistic approach is the most commonly used method to solve time varying harmonics. This paper provides an in depth analysis on harmonics field measurement of the high speed electric train loads, harmonics assessment by the international harmonic standards IEC 61000-3-6 and IEEE Std. 519-1992, and harmonics simulation using EDSA program for the case study.

  • PDF

Muscle activity in relation to the changes in peripheral nerve conduction velocity in stroke patients: Focus on the dynamic neural mobilization technique

  • Kang, Jeong IL;Moon, Young Jun;Jeong, Dae Keun;Choi, Hyun;Park, Joon Su;Choi, Hyun Ho
    • 국제물리치료학회지
    • /
    • 제9권2호
    • /
    • pp.1447-1454
    • /
    • 2018
  • The objective of this study was to investigate the dynamic neural mobilization program on the changes in muscle activity and nerve conduction velocity (NVC) in stroke patients. The participants were sampled and randomly divided into experimental group I (n=12) who underwent arm neural mobilization and experimental group II (n=13) who underwent arm dynamic neural mobilization. As the pretest, peripheral NVC of the radial, median, and ulnar nerves were measured using the Viking Quest; the biceps brachii, brachioradialis, flexor carpi radialis, and extensor carpi radialis activities were measured with sEMG. Each intervention program consisted of 10 trials per set and three sets per session. The intervention programs were performed once daily for four weeks (four days/week). Posttest measurements were taken equally as the pretest measurements. Significant differences in peripheral NVC in all sections of the radial and median nerves and wristbelow elbow and below elbow-above elbow areas of the ulnar nerve, as well as in muscle activity of all muscles except the biceps brachii. These findings indicate that dynamic neural mobilization was effective in increasing peripheral NVC and altering the muscle activity.

간호학생을 위한 메타버스기반 활력징후측정과 피하주사 핵심간호술 콘텐츠 개발 및 효과 검증 (The development and effects of metaverse-based core nursing skill contents of vital signs measurements and subcutaneous injections for nursing students)

  • 안민권
    • 한국간호교육학회지
    • /
    • 제28권4호
    • /
    • pp.378-388
    • /
    • 2022
  • Purpose: The purpose of this study was to evaluate the effects of Metaverse-based core nursing skill contents (CNSC) developed for undergraduate nursing students. Methods: A nonequivalent control group was sampled with a non-synchronized design. Seventy-two participants (experimental group 34, control group 38) were recruited from May to June 2022 in Gwangju metropolitan city. The CNSC consisted of scenarios of vital sign measurements, and subcutaneous injections (including blood sugar tests). The data were analyzed using SPSS version 25 for Windows. Results: At the completion of the CNSC, statistically differences were found between groups in knowledge of core nursing skills (t=6.20, p<.001), confidence in core nursing skills performance (t=5.71, p<.001), and clinical competency (t=3.32, p=.001). Conclusion: These results indicate that the CNSC developed for undergraduate nursing students is effective in improving knowledge of core nursing skills, confidence in core nursing skills performance, and clinical competency for nursing students.

Split beam 어군탐지기에 의한 어류의 유영행동 조사연구 -유영속도의 측정- (Fish Tracking with a Split Beam Echo Sounder -Measurements of Swimming Speeds-)

  • 이대재
    • 수산해양기술연구
    • /
    • 제35권3호
    • /
    • pp.301-311
    • /
    • 1999
  • The investigation to evaluate the possible effects of fish behaviour on acoustic target strength was carried out during the 1997 and 1998 hydroacoustic-demersal trawl surveys in the southern waters of Korea.The swimming speed and the target strength of individual, acoustically resolved fished swimming through the sound beam were measured using the split-beam tracking method on board R/V Kaya.The results obtained can be summarized as follows:1. The alongship and athwartship angles between -3dB poionts of a hull mounted 38 kHz split beam tranducer used in these surveys was >$3.76^{\circ}\;and\;6.74^{\circ}$ respectively, and the equal energy contour obtained from the measured beam pattern showed approximately the circular pattern. 2. The swimming speed measured off the south coast of Sorido in 23 January 1997 ranged 0.10 to 0.80 m/s with the average swimming spped of 0.36 m/s, and the target strength ranged -64.8 to -31.7 dB with the average target strength of -52.7 dB. The most dominant species sampled in this survey area were Japanese scaled sardine, Sardinella zunasi and Konoshiro gizzard shad, Konosirus punctatus, respectively.3. The swimming speed measured off the east coast of Kojedo in 24 March 1997 ranged 0.10 to 1.10 m/s with the average swimming speed of 0.40 m/s, and the target strength ranged -64.8 to -51.5 dB with the average target strength of -59.2 dB. The most dominant species sampled in this survey area were Swordtip squid, Photololigo edulis, Konoshiro gizzard shad and Japanese flying squid, Toddarodes pacificus, respectively and the swimming activity of these species seems to be controlled at speeds between 0.20 and 0.60 m/s. 4. The swimming speed measured the south coast of Kojedo in 25 March 1997 ranged 0.10 to 1.40 m/s with the average swimming speed of 0.51 m/s and the target strength ranged -64.3 to -47.7 dB with the average target strength of -55.1 dB. The most dominant species sampled in this survey area were Swordtip squid, Blotchy sillage, Sillago maculata and japanese scaled sardine, respectively and the swimming activity of these species seems to be controlled at speeds between 0.20 and 0.70 m/s.5. The swimming speed measured during morning twilight in the southeastern water of Cheju Island in 11 July 1998 ranged 0.20 to 1.0 m/s with the average swimming speed of 0.53 m/s, and the target strength ranged -65.0 to -47.0 dB with the average target strength of -57.1 dB. The most dominant species sampled in this survey area were Swordtip squid, Black scraper, Thamnaconus modesutus and japanese flying squid, respectively and the tile angle ranged$ +28^{\circ}\;to\;+2^{\circ}$ with the average tilt angle of -8.1$^{\circ}$ showing the downward migration.

  • PDF

Skin Thickness of the Anterior, Anteromedial, and Anterolateral Thigh: A Cadaveric Study for Split-Skin Graft Donor Sites

  • Chan, Jeffrey C.Y.;Ward, John;Quondamatteo, Fabio;Dockery, Peter;Kelly, John L.
    • Archives of Plastic Surgery
    • /
    • 제41권6호
    • /
    • pp.673-678
    • /
    • 2014
  • Background The depth of graft harvest and the residual dermis available for reepithelization primarily influence the healing of split-skin graft donor sites. When the thigh region is chosen, the authors hypothesize based on thickness measurements that the anterolateral region is the optimal donor site. Methods Full-thickness skin specimens were sampled from the anteromedial, anterior, and anterolateral regions of human cadavers. Skin specimens were cut perpendicularly with a custom-made precision apparatus to avoid the overestimation of thickness measurements. The combined epidermal and dermal thicknesses (overall skin thickness) were measured using a digital calliper. The specimens were histologically stained to visualize their basement membrane, and microscopy images were captured. Since the epidermal thickness varies across the specimen, a stereological method was used to eliminate observer bias. Results Epidermal thickness represented 2.5% to 9.9% of the overall skin thickness. There was a significant difference in epidermal thickness from one region to another (P<0.05). The anterolateral thigh region had the most consistent and highest mean epidermal thickness ($60{\pm}3.2{\mu}m$). We observed that overall skin thickness increased laterally from the anteromedial region to the anterior and anterolateral regions of the thigh. The overall skin thickness measured $1,032{\pm}435{\mu}m$ in the anteromedial region compared to $1,220{\pm}257{\mu}m$ in the anterolateral region. Conclusions Based on skin thickness measurements, the anterolateral thigh had the thickest epidermal and dermal layers. We suggest that the anterolateral thigh region is the optimal donor site for split-skin graft harvests from the thigh.

Precision Orbit Determination of the SAC-C Satellite Using the GPS Dual Frequency Measurement

  • Yoon, Jae-Cheol;Im, Jeong-Heum;Moon, Hong-Youl;Lee, Sang-Ryool;Lee, Byoung-Sun
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 2003년도 한국우주과학회보 제12권2호
    • /
    • pp.48-48
    • /
    • 2003
  • A precision orbit determination (POD) system of low Earth orbiter using the GPS dual frequency measurements has been developed. It is an option of KOMPSAT-2 POD process system. In this research, the orbit determination using the real dual frequency carrier phase measurements of the SAC-C satellite was conducted to verify KOMPSAT-2 POD system reliability. The SAC-C satellite is an international cooperative mission between NASA, the Argentine Commission on Space Activities (CONAE), Centre National d'Etudes Spatiales (CNES or the French Space Agency), Instituto Nacional De Pesquisas Espaciais (Brazilian Space Agency), Danish Space Research Institute, and Agenzia Spaziale Italiana (Italian Space Agency). The SAC-C was launched at November 21, 2000. The altitude of SAC-C is 702 km and it carries a TurboRogue III GPS and four high gain antennas developed by the JPL. The receiver is able to generate the dual frequency code and carrier phase data. Double-differenced carrier phase measurements were formed using 25 IGS stations. The data were sampled at 30 seconds interval. Fully dynamic approach was adopted for POD. The POD results were compared with those of JPL using GOA n software. The comparison verifies that deci-meter level 3D position accuracy of low Earth orbiting satellite could be achieved. The POD system has been developed successfully.

  • PDF

중국과 한국 20대 여성의 체간부 신체치수와 체형 비교 분석 (A Comparative Analysis of Torso Measurements and Types of the Chinese and Korean Women in their 20's)

  • 장희경;손희순
    • 패션비즈니스
    • /
    • 제13권2호
    • /
    • pp.17-29
    • /
    • 2009
  • Due to rapid economic growth and accelerated urbanization, numerous cities in China have been turning into huge consumption markets almost simultaneously, and thus, the Chinese apparel markets being globalized are most vigorous in the world, attracting attention from the world apparel industries. If the Korean apparel businesses should develop the products befitting the conditions of the Chinese apparel markets and reflecting her consumers' fashion trends and needs, their apparels would be satisfactory enough to Chinese consumers, being competitive in the Chinese markets. In this sense, today's Chinese apparel markets may well provide the Korean apparel businesses with both crisis and opportunity. As one of the methods to enhance Chinese consumers' satisfaction with the Korean apparels, the Korean apparel businesses should consider seriously about the apparel fitting or a factor determining apparel silhouettes and sense of wearing. Since Chinese consumers differ widely in terms of body types and measurements depending on regions due to the vast territory, differentiation of the apparel fitting is more important than any other single factor, and thus, correct information about apparel fitting may well be directly related with manufacturing of excellent apparels. The purpose of this study is to comparatively analyze the upper body measurements and types of the Chinese and Korean women in their 20's to provide the Korean apparel business engaged in Chinese markets with some basic data about apparel fitting conducive to their development of effective apparel commodities. For this purpose, Chinese women in their 20's living in China's two major cities leading China's women's apparel markets were sampled.

Serial venous lactate measurement following gastrointestinal surgery in horses

  • Smanik, Lauren E.;Moser, Darla K.;Rothers, Kris P.;Hackett, Eileen S.
    • Journal of Veterinary Science
    • /
    • 제23권5호
    • /
    • pp.66.1-66.8
    • /
    • 2022
  • Background: Prospective clinical study of blood lactate concentration in horses undergoing colic surgery is needed to determine utility in outcome prediction. Objectives: To evaluate venous lactate measurements in horses following colic surgery, including immediately after anesthetic recovery and daily throughout hospitalization, as well as to determine if lactate concentrations were significantly higher in horses that developed postoperative complications or did not survive to hospital discharge. Methods: Horses > 1 year of age undergoing surgery for colic and recovered from general anesthesia were sampled. A portable lactate meter was used to measure venous samples collected immediately following anesthetic recovery and daily throughout hospitalization. Complications arising during hospitalization and survival to hospital discharge were recorded. Results: Fifty one horses were enrolled, ranging in age from 2 to 29 years. Lactate concentration immediately following anesthetic recovery was higher in horses that developed complications during hospitalization (p = 0.046). The odds of developing complications postoperatively were doubled for horses with a venous lactate concentration > 5 mmol/L. Lactate measurements in non-survivors were significantly higher compared to survivors by 96 h postoperatively (p < 0.006). Conclusions: Higher venous lactate concentrations in the postoperative colic period were associated with an increased risk of complications and death. Results suggest horses with higher venous lactate measurements in recovery are more likely to have postoperative complications, with the odds of developing complications doubled for horses with a venous lactate > 5 mmol/L. Evaluation of venous lactate could provide information on prognosis in the postoperative period for horses with surgical colic.

750kW급 풍력발전기의 부하 모니터링 시스템에 관한 연구 (A Study on the Mechanical loads Monitoring System of a 750kW Wind Turbine)

  • 남윤수;장후영;윤태준
    • 산업기술연구
    • /
    • 제28권A호
    • /
    • pp.63-69
    • /
    • 2008
  • The exact load measurements for the mechanical parts of wind turbine are important step both for evaluation of specific wind turbine design and for a certification process. A wind turbine monitoring system is essential equipment for mechanical load analysis of a wind turbine. This monitoring system is based on IEC 61400-13 and strain gage are used to measure a mechanical load of wind turbine. Also this system monitors signals from a meteorological mast. The measured signals which are sampled at 200 Hz are automatically saved on a data file in the unit of ten minutes. A detail explanation for the developed wind turbine monitoring system is presented in this study.

  • PDF