• Title/Summary/Keyword: sample selectivity

Search Result 97, Processing Time 0.029 seconds

용존 산소 측정용 초소형 Clark-type 센서에 대한 연구 (A Study on the Microfabricated Clark-type Sensor for Measuring Dissolved Oxygen)

  • 박정일;장종현;최명기;이동영;김영미;박정호
    • 전기학회논문지
    • /
    • 제56권8호
    • /
    • pp.1450-1454
    • /
    • 2007
  • This paper presents a microfabricated Clark-type sensor which exactly can measure dissolved oxygen in the cell containing solution. We designed, fabricated, and characterized a microfabircated Clark-type oxygen sensor for measuring dissolved oxygen. The microfabricated oxygen sensor consists of 3-electrodes on a glass substrate, a FEP (Fluorinated ethylene propylene) oxygen-permeable membrane, and PDMS (Polydimethylsiloxane) reservoir for storing sample solution. Thin-film Ag/AgCl was employed as a reference electrode and its durability was verified by obtaining a stable open circuit potential for 2 hours against a commercial Ag/AgCl electrode and a stable cyclic voltammetry curve. Selectivity, response time, and linearity of the fabricated oxygen sensor were also verified well by cyclic voltammetry and amperometry depending. The fabricated oxygen sensor showed a 90% response time of 40sec and an excellent linearity with a correlation coefficient of 0.994.

Model of Simultaneous Travel time and Activity Duration for worker with Transportation Panel Data

  • Kim Soon-Gwan
    • 대한교통학회:학술대회논문집
    • /
    • 대한교통학회 1998년도 Proceedings The 4th International Transport Symposium
    • /
    • pp.160-167
    • /
    • 1998
  • Recent world-wide interest in activity-based travel behavior modeling has generated an entirely new perspective on how the profession views the travel demand process. This paper seeks to further promote the case of activity-based travel behavior models by providing some empirical evidence of relationship between travel time and activity duration decision for worker with transportation panel data. The travel time from home to work and from work to home, without activity involvement, is estimated by the Ordinary Least Squares (OLS) method. And, the travel time to and from the selected activity and the activity duration are modeled simultaneously by the Three Stage Least Squares (3SLS) method due to the endogenous relationship between travel time and activity duration. Two kinds of models, OLS and 3SLS, include selectivity bias corrections in a discrete/continuous framework, because of the inter-relationship between the choice of activity type/travel mode (discrete) and the travel time/activity duration (continuous). Estimation is undertaken using a sample of over 1300 household two-day trip diaries collected from the same travelers in the Seattle area in 1989. The behavioral consequences of these models provide interesting and provocative findings that should be of value to transportation policy formulation and analysis.

  • PDF

Simultaneous Determination of Statins in Human Urine by Dilute-and-Shoot-Liquid Chromatography-Mass Spectrometry

  • Jang, Haejong;Mai, Xuan-Lan;Lee, Gunhee;Ahn, Jae Hyoung;Rhee, Jongsook;Truong, Quoc-Ky;Vinh, Dinh;Hong, Jongki;Kim, Kyeong Ho
    • Mass Spectrometry Letters
    • /
    • 제9권4호
    • /
    • pp.95-99
    • /
    • 2018
  • An innovative, simple, and rapid assay method based on liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) was developed and validated for the simultaneous determination of eight statin drugs in human urine. A simple sample clean-up procedure using the "dilute and shoot" (DAS) approach enabled a fast and reliable analysis. The influence of the dilution factor was investigated to ensure detectability and reduce the matrix effect. Chromatographic separation was performed on a Phenomenex Kinetex C18 column ($50{\times}3.0mm$ i.d., $2.6{\mu}m$) using an elution gradient of mobile phase A composed of 0.1% acetic acid, and mobile phase B composed of acetonitrile, at a flow rate of 0.35 mL/min. Quantitation was performed on a triple quadrupole mass spectrometer operated in multiple reaction monitoring (MRM) mode using electrospray ionization in positive ion mode. The total chromatographic run time was 15 min. The method was validated for selectivity, sensitivity, recovery, linearity, accuracy, precision, and stability. The present method was successfully applied to the analysis of Rosuvastatin in urine samples after oral administration to healthy human subjects.

수소 동위원소 분리를 위한 77 K 극저온 파과 곡선 측정 시스템 제작 (Investigation of Cryogenic Breakthrough Curve Measurement System at 77 K for Hydrogen Isotopologue Separation)

  • 김수환;오현철
    • 한국재료학회지
    • /
    • 제32권1호
    • /
    • pp.36-43
    • /
    • 2022
  • Breakthrough analysis has widely been explored for the dynamic separation of gaseous mixtures in porous materials. In general, breakthrough experiments measure the components of a flowing gas when a gaseous mixture is injected into a column filled with an adsorbent material. In this paper, we report on the design and fabrication of a breakthrough curve measurement device to study the dynamic adsorptive separation of hydrogen isotopologues in porous materials. Using the designed system, an experiment was conducted involving a 1:1 mixture of hydrogen and deuterium passed through a column filled with zeolite 13X (1 g). At room temperature, both hydrogen and deuterium were adsorbed in negligible amounts; however, at a temperature of 77 K, deuterium was preferentially adsorbed over hydrogen. The selectivity was different from that in the existing literature due to the different sample shapes, measurement methods, and column structures, but was at a similar level to that of cryogenic distillation (1.5).

Direct Detection of Water-dissolved Ammonia Using Paper-based Analytical Devices

  • Yeong Beom Cho;Duc Cuong Nguyen;Si Hiep Hua;Yong Shin Kim
    • 센서학회지
    • /
    • 제32권2호
    • /
    • pp.67-74
    • /
    • 2023
  • A microfluidic paper-based analytical device (µPAD) is proposed for the selective detection of ammonia in water by using the modified Berthelot reagent and a fluidic channel consisting of hollow paper. The modified Berthelot reagents were uniformly dispersed in cyclohexane and then immobilized in a detection zone of the µPAD. The loading position of the reagents and the type of a sample flow channel were optimized to achieve a sensitive ammonia detection within a short analytical time. The NH3 µPAD exhibits a linear colorimetric response to the concentration of ammonia dissolved in water in the range of 1-100 mg L-1, and its limit-of-detection is 1.75 mg L-1. In addition, the colorimetric response was not influenced by the addition of 100 mg L-1 nitrogen containing compounds (sodium nitrate, sodium nitrite, uric acid, hydroxylamine, butylamine, diethylamine) or inorganic salts (NaCl, Na2HPO4), presenting the enough selectivity in the detection of water-dissolved ammonia against possible interferents.

HILIC 분석법 개발을 위한 지능형 솔루션 (Hydrophilic Interaction Liquid Chromatography)

  • Matt James;Colin Pipe;Mark Fever;Jen Field;Seungho Chae
    • FOCUS: LIFE SCIENCE
    • /
    • 제1호
    • /
    • pp.6.1-6.9
    • /
    • 2024
  • The document is a white paper on Hydrophilic Interaction Liquid Chromatography (HILIC) analysis method development. HILIC is a type of chromatography that uses an organic/aqueous mobile phase and a polar stationary phase. In HILIC, water is a strong solvent, and unlike in Reversed Phase Liquid Chromatography (RPLC), increasing the proportion of water in the mobile phase reduces the retention time of the analyte. The paper discusses when to consider HILIC analysis methods, the advantages of HILIC, and the challenges often encountered due to the lack of understanding of HILIC mechanisms compared to RPLC. It also provides a systematic flowchart for intelligent solutions for HILIC analysis method development, which includes a three-step approach for chromatography analysis method development. The first step involves gathering as much information as possible about the analyte (e.g., pKa, log P, log D). The second step involves analyzing the sample under different pH conditions using three HILIC columns in either isocratic or gradient mode to identify the suitable column/pH combination for the analyte. The third step involves optimizing the separation by investigating other parameters such as temperature and ionic strength, and assessing the robustness of the method. The paper emphasizes that the selection of the appropriate stationary/mobile phase combination, based on the differences between the HILIC stationary phases and the mobile phase pH, can provide high selectivity in the analysis. This step-by-step approach can help users develop an efficient analysis method.

  • PDF

프로판 탈수소 반응에 미치는 금속산화물과 혼합된 Pt-Sn/Al2O3 촉매의 영향 (Effect of Pt-Sn/Al2O3 catalysts mixed with metal oxides for propane dehydrogenation)

  • 정재원;고형림
    • 한국응용과학기술학회지
    • /
    • 제33권2호
    • /
    • pp.401-410
    • /
    • 2016
  • 금속 산화물과 혼합한 $Pt-Sn/Al_2O_3$ 촉매의 프로판 탈수소 반응 성능의 향상 가능성에 대해서 연구하였다. 금속 산화물로서 $Cu-Mn/{\gamma}-Al_2O_3$, $Ni-Mn/{\gamma}-Al_2O_3$, $Cu/{\alpha}-Al_2O_3$를 제조하여 $Pt-Sn/Al_2O_3$ 촉매와 혼합하고, 프로판 탈수소 반응 성능을 측정하였다. 이 결과들을 불활성 물질인 glass bead를 혼합한 $Pt-Sn/Al_2O_3$ 촉매를 기준샘플로 삼아 비교하였다. 촉매와 금속산화물을 환원처리하지 않고 반응 실험한 경우, $576.5^{\circ}C$에서 기준샘플의 전환율 8% 대비, $Cu-Mn/{\gamma}-Al_2O_3$를 혼합한 $Pt-Sn/Al_2O_3$ 촉매가 14.9%의 높은 전환율과 96.8%의 선택도를 보였다. 촉매와 금속산화물을 환원 처리하여 반응활성을 측정한 경우, $Cu/{\alpha}-Al_2O_3$$Pt-Sn/Al_2O_3$의 혼합촉매가 기준샘플대비 초기에 높은 수율을 보였다. 그러나, 촉매를 환원 처리한 경우 전반적으로 전환율 상승이 크지 않았고, 이것으로 $Cu-Mn/{\gamma}-Al_2O_3$의 격자산소가 탈수소반응의 전환율 증가 영향을 주었음을 알 수 있었다.

DTO 반응에서 촉매수명과 경질 올레핀 선택도에 미치는 SAPO-34의 산 처리 효과 (Effects of Acid Treatment of SAPO-34 on the Catalytic Lifetime and Light Olefin Selectivity during DTO Reaction)

  • 최기환;이동희;김효섭;박주식;김영호
    • 공업화학
    • /
    • 제26권2호
    • /
    • pp.217-223
    • /
    • 2015
  • DTO (dimethyl ether to olefin) 반응에서 촉매 성능을 향상하기 위하여 염산에 의한 SAPO-34 시료의 산 처리 영향을 연구했다. 먼저 TEAOH (tetraethylammonium hydroxide)와 DEA (diethylamine)를 구조유도제로 사용하여 정육면체 형태를 갖는 균일한 크기의 SAPO-34 시료를 수열 합성했다. 제조된 촉매는 염산의 농도 및 처리 시간을 변수로 하여 개조되었다. 그 결과, 우수하게 개조된 시료는 외부 표면의 침식과 함께 총 비표면적 및 마이크로 세공부피가 증가하였으며, 산점량이 다소 감소하는 것으로 나타났다. 특히, 개조된 SAPO-0.2 M (3 h) 시료 상에서의 DTO 반응에서 촉매 수명과 경질 올레핀 선택성은 모체 SAPO-34 시료와 비교하여 크게 향상되었다. 이것은 코크 형성에 의한 비활성화가 주로 결정 외부 표면의 기공 입구에서 상대적으로 빠르게 진행된다는 것을 의미한다. 따라서 산 처리는 SAPO-34 촉매의 외부 표면을 개조함으로써 촉매의 성능을 향상할 수 있는 단순한 방법임을 확인했다.

지불거부응답의 판별 (Detecting Protest Responses)

  • 오형나
    • KDI Journal of Economic Policy
    • /
    • 제34권1호
    • /
    • pp.135-168
    • /
    • 2012
  • 조건부가치측정법(contingent valuation method)은 비시장재의 경제적 가치를 추정하는 방법의 하나로, 공공사업의 경제적 편익을 계산하는 데 이용되어 왔다. 지불거부응답(protest responses)은 본인의 선호와 상관없이 설문과정에서 공공사업에 대해 단 1원도 지불할 의사가 없다고 응답하는 행동으로, 전체 CVM 응답의 25% 정도를 차지한다. 본 연구는 평가 대상이 된 공공재의 가치 추정에 있어 지불거부응답 행동에 의한 편의(bias)를 최소화하기 위해, 자신의 선호에 의해 지불의사액이 '0'이라고 답한 응답으로부터 지불거부응답을 판별해 내는 문항(protest response filtering items)과 그 미시적 근거를 제시한다. 이를 위해 본 논문은 선호에 기반한 지불의사액을 '잠재적 지불의사액(implicit willingness-to-pay)'이라고 정의함으로써 설문과정에서 선호체계 이외에 다양한 요인이 작용하여 결정된 '구술된 지불의사액(stated willingness-to-pay)'과 구분하였다. 한편, 한국개발연구원(KDI)에서 주관한 20여 건의 CVM 데이터를 이용한 실증분석 결과에 의하면, 지불거부응답은 무작위가 아닌 응답자의 사회 경제적 특징에 의해 체계적으로 발생한다. 이는 지불거부응답을 공공재의 경제적 가치 추정에서 제외시킬 때 선택편의(selectivity bias)가 발생할 수 있음을 의미한다.

  • PDF

이산화탄소 압력순환흡착을 위한 칼슘 이온교환 Y 제올라이트의 작업용량과 선택계수 향상 (Enhancement of the Working Capacity and Selectivity Factor of Calcium-Exchanged Y Zeolites for Carbon Dioxide Pressure Swing Adsorption)

  • 김문현
    • 청정기술
    • /
    • 제24권1호
    • /
    • pp.41-49
    • /
    • 2018
  • $25^{\circ}C$에서 $CO_2$ 흡착을 위한 작업용량과 $CO_2/CO$ 선택계수를 현저하게 향상시키기 위하여 서로 다른 전하와 이온반경을 갖는 $Na^+$, $N^+$, $Ca^{2+}$$Cu^{2+}$로 이온교환된 Y 제올라이트들이 연구되었다. 매우 소량인 0.012% $Ca^{2+}$로 이온교환된 NaY는 7회의 반복적인 $CO_2$ 흡착/탈착 싸이클 동안에도 완전히 가역적이었으므로 기존에 보고된 것들과는 달리 표면에 카보네이트는 생성되지 않는 것으로 생각된다. 4 bar 이상에서 2.00% CaY, 1.60% CuY와 1.87% LiY 모두 NaY와 매우 유사한 $CO_2$ 흡착성능을 보였다할지라도 그보다 낮은 압력에서는 이들의 흡착능은 감소하였고 그 정도는 금속이온들의 종류에 의존하였다. 0.5 ~ 2.5 bar에서 $CO_2$ 흡착성능은 NaY > 1.60% CuY > 2.00% CaY > 1.87% LiY의 순으로 나타났는데, 이들 모두 동일한 faujasite 골격과 약 2.6의 Si/Al 비율을 가지므로 골격, 골격조성, 유효세공크기와 채널구조에 있어서 차이는 없기 때문에 약한 루이스산의 특성을 갖는 $CO_2$의 구별되는 흡착거동은 이온교환에 따른 국부염기도와 흡착 포텐셜 에너지의 변화 때문일 것이다. $CO_2$ 흡착과는 다른 경향성이 CO 흡착에서 나타났고 이는 보다 약한 사극자 상호작용 때문이다. 0.012 ~ 5.23% Ca 함량을 갖는 Y 제올라이트에 $CO_2$와 CO 흡착 시 Ca 함량에 따른 현저한 의존성이 존재하였는데 0.05% 이하에서 $CO_2$ 흡착능은 증가한 반면에 그 이상에서는 감소하였다. 이러한 경향에도 불구하고 Ca 함량의 증가와 함께 작업용량과 $CO_2/CO$ 선택계수는 현저히 증가하였고, 5.23% CaY의 경우 작업용량은 $2.37mmol\;g^{-1}$, 선택계수는 4.37이었는데 본 연구에서 얻어진 작업용량은 문헌에 보고된 벤치마크와 유사한 수준이었다.