• Title/Summary/Keyword: sample selectivity

Search Result 97, Processing Time 0.025 seconds

The Analysis on the Effect of Familism on Suicide Ideation: Focusing on Difference between young Adults and Old Adults (자살생각에 대한 가족주의의 영향분석 -청·장년 집단과 노년 집단의 차이를 중심으로-)

  • Park, Joon-Shik;Kim, Young Bum
    • Journal of Digital Convergence
    • /
    • v.12 no.7
    • /
    • pp.419-430
    • /
    • 2014
  • The main object of the study is to investigate factors affecting the suicide ideation. According to the socioemotional selectivity theory, because of limitation of life time, the family relationship is more important for elderly than young or middle aged group. Based on this theory authors hypothesizes that the familism may show negative relationship with suicide ideation only in elderly group. The data for the study comes from the survey titled understanding on the successful aging of Korean people conducted in 2008. The sample size of the survey is 1,000 and the survey was conducted by the face to face interview with the standardized questionnaire. According to the analysis, familism shows negative relationship with suicide ideation only in elderly group, not in young or middle adult group.

The Impact of Divorce on Tenure Choice for Women in Korea (자가점유로 분석한 이혼여성의 주거안정성)

  • Hwang, Jae-Hee;Lee, Seong-Woo
    • Journal of the Korean housing association
    • /
    • v.23 no.1
    • /
    • pp.55-66
    • /
    • 2012
  • Present study investigates on the impact of resources and characteristics of the tenure choice for divorced women in Korea. The authors utilize the micro data from the Korea Census (2% sample) provided by the National Statistical Office. The authors apply the bivariate probit model to eliminate selection bias that could incur due to sample selectivity, from a chain of marital disruption and tenure choices. This study starts with a descriptive explanation of homeownership after divorce from 1985 to 2005. It concluded that divorce results in a substantial attrition of homeownership. The authors found that out for many women, divorce initiates a process of downward mobility on the housing ladder. The probability to own housing is much lower for divorced women than for women who are not divorced. The present study concludes by suggesting some policy implications for divorced women who have limited access to housing stability. The authors also suggest some future studies that can compensate the empirical limitations of the present study.

Separation of Radiostrontium from Environmental Sample Using Strontim Selective Chromatographic Resin$(Sr.\;Spec^{TM})$ (스트론튬 선택적이온교환수지$(Sr.\;Spec^{TM})$를 이용한 환경시료중의 방사성 스트론튬의 분리)

  • Hong, Kwang-Hee;Lee, Chang-Woo;Choi, Yong-Ho;Lee, Myung-Ho
    • Journal of Radiation Protection and Research
    • /
    • v.20 no.1
    • /
    • pp.1-7
    • /
    • 1995
  • Strontium selective chromatographic material $(Sr-Spec^{TM})$ was investigated for separation of radiostrontium from environmental soil and water sample. This chromatographic material has great capacity of binding of strontium ion in nitric acid media, and has selectivity to permit the separation of stontium from bulk amount of calcium. But the extraction of strontium was reduced by the other interfering ions such as K and Ba. So, in order to apply this material to the soil sample, prior removal treatment of K and Ba was needed. But the Sr-Spec material could provides simple and effective methods for the separation and removal of radiostrontium from liquid sample.

  • PDF

Development of a Method for Detecting Iodide and Chloride Ions in Infant Formula using an Ion Selectivity Electrode (이온선택성 전극법을 이용한 조제분유중의 염소 및 요오드 이온함량 분석방법 연구)

  • Ko, Jin-Hyouk;Kwak, Byung-Man;Ahn, Jang-Hyuk;Jeon, Tae-Hong
    • Food Science of Animal Resources
    • /
    • v.28 no.3
    • /
    • pp.301-305
    • /
    • 2008
  • This study was carried out to develop an accurate and rapid analysis method to measure the contents of iodide and chloride in infant formula using an ion selectivity electrode. The infant formula SRM 1846 (Standard Reference Material 1846, NIST, USA) was used as a CRM (Certified reference material). Samples were dissolved in water with 3% acetic acid and filtered through filter paper and adjusted to pH 7.0 with 0.1N NaOH. At pH 7.0, the iodide content of the CRM was $1.04{\pm}0.03\;mg/kg$ compared to the specification of $1.11{\pm}0.1\;mg/kg$ of CRM, and the recovery was $93.7{\pm}2.7%$. The chloride content was $5114.3{\pm}240\;mg/kg$ compared to the specification of $4,920{\pm}300mg/kg$ of CRM, and the recovery was $103.9{\pm}4.9%$. Ion selectivity electrodes could be successful1y used to determine the concentration of iodide and chloride ions in infant formula by a simple and rapid pretreatment of sample matrixes.

Peltier Heating-Assisted Low Temperature Plasma Ionization for Ambient Mass Spectrometry

  • Lee, Hyoung Jun;Oh, Ji-Seon;Heo, Sung Woo;Moon, Jeong Hee;Kim, Jeong-hoon;Park, Sung Goo;Park, Byoung Chul;Kweon, Gi Ryang;Yim, Yong-Hyeon
    • Mass Spectrometry Letters
    • /
    • v.6 no.3
    • /
    • pp.71-74
    • /
    • 2015
  • Low temperature plasma (LTP) ionization mass spectrometry (MS) is one of the widely used ambient analysis methods which allows soft-ionization and rapid analysis of samples in ambient condition with minimal or no sample preparation. One of the major advantages of LTP MS is selective analysis of low-molecular weight, volatile and low- to medium-polarity analytes in a sample. On the contrary, the selectivity for particular class of compound also implies its limitation in general analysis. One of the critical factors limiting LTP ionization efficiency is poor desorption of analytes with low volatility. In this study, a home-built LTP ionization source with Peltier heating sample stage was constructed to enhance desorption and ionization efficiencies of analytes in a sample and its performance was evaluated using standard mixture containing fatty acid ethyl esters (FAEEs). It was also used to reproduce the previous bacterial identification experiment using pattern-recognition for FAEEs. Our result indicates, however, that the bacterial differentiation from FAEE pattern recognition using LTP ionization MS still has many limitations.

Adsorption Characteristics of Pb(II), Cu(II), Cr(III), and Zn(II) Ions by Domestic Loess Minerals (국내산 황토를 이용한 수용액중의 Pb(II), Cu(II), Cr(III) 및 Zn(II) 이온의 흡착 특성)

  • 정의덕;김호성;원미숙;윤장희;박경원;백우현
    • Journal of Environmental Science International
    • /
    • v.8 no.4
    • /
    • pp.497-502
    • /
    • 1999
  • Removal of Pb(Ⅱ), Cu(Ⅱ), Cr(Ⅲ), and Zn(Ⅱ) ions from aqueous solutions using the adsorption process on domestic loess minerals has been investigated. Variations of contact time, pH, adsorption isotherms and selectivity of coexisting ions and leachate were experimental parameters. YDI, YPT and KRT samples diluted in 1% aquous solution which was adjusted pH 10.8, 8.0 and 6.50, respectively. The result of XRD measurement, Quartz was mainly observed in all samples. In the case of KRT sample, Kaolinite, Feldspar, Chlorite consisting of clay minerals shows almost same pattern with YPT samples. Different properties showed from the YDI sample containing Iillite, remarkably. For all the metals, maximum adsorption was observed at 30min∼60min. Adsorption of metal ions on loess minerals were reached an equilibrium by shaking the solution for about 30min. Removal efficiency of Pb(Ⅱ) ion for KRT, YPT and YDI were 84.7%, 92% and 100%, respectively. The Cu(Ⅱ) and Zn(Ⅱ) adsorptivity on KRT showed the low in various pH solution However, those on YPT and YDI were high than 90% except for the pH 2 solution. The orders of adsorptivities for domestic loess minerals showed as following : YPT>KRT>YDI. The adsorption isotherms of Cu(Ⅱ) and Zn(Ⅱ) ions on clay minerals were fitted to a Freundlich's. Freundlich constants(1/n) of KRT and YPT domestic loess minerals were 0.63, 0.97 and 0.36, 0.25, respectively.

  • PDF

A Study on Purchasing Agricultural Products of Re-visitors In Traditional Market Using Double Hurdle Model (더블허들 모형을 이용한 전통시장 재방문객의 농산물 구입결정 요인에 관한 연구)

  • Yi, Hyangmi
    • Journal of Korean Society of Rural Planning
    • /
    • v.21 no.2
    • /
    • pp.137-147
    • /
    • 2015
  • In this study, consumers who have experience of visiting Jeongsun Arirang Market has been selected as samples to understand the characteristics of agricultural products purchase. For this, double hurdle model was used in order to resolve sample selection problem and obtain consistent estimator. The key points are the following. First, as the age increases(up to 59.8 years), chances of purchasing the products at traditional market increase as income increases. Second, when the residence area is outside of Gangwon-province, the purchase amount of the products increased compared to those from visitors within the Gangwon province. Also, visitors who use public transportations purchase less products compared to those who use their own car. Third, probability of agricultural products increase as the visitors consider positive effect the product purchase leads to the local farmers. Fourth, if the visitors consider the quality of the agricultural products, probability of purchasing agricultural product at the site increases. However, if the visitors consider the freshness of the agricultural products, the purchase amount rather drops. Fifth, the probability of purchase increases as visitors consider the brand of traditional market.

Development of Analytical Techniques for Human Serum and Urine by Using Glow Discharge (글로우 방전을 이용한 혈청과 뇨의 분석기술 개발)

  • Lee, Sang Chun;Choi, Kyung-Soo;Son, Eun-Ho;Sim, Young-Jin
    • Analytical Science and Technology
    • /
    • v.11 no.3
    • /
    • pp.167-173
    • /
    • 1998
  • An electrothermal vaporization-hollow cathode glow discharge-atomic emission spectrometer(ETV-HCGD-AES) has been developed for detecting heavy metals in human serum and urine samples. Fisrt of all, we designed a glow discharge cell for atomic emission spectrometry and its analytical performance was studied with the standard reference materials(SRMs) purchased from the NIST. Practically, the ETV-HCGD-AES demonstrated better instrumental sensitivity and selectivity for detecting Hg and Pb in the SRMs, serum and urine, than ICP-OES since the ETV-HCGD-AES was not required the complicate sample digestion procedure, which improved sample transportation efficiency.

  • PDF

Column regeneration for Partisil/Partisphere ion-exchange columns (Partisil/Partisphere 이온 교환 컬럼 재생 가이드)

  • Mark Fever;Gemma Howse
    • FOCUS: LIFE SCIENCE
    • /
    • no.1
    • /
    • pp.5.1-5.3
    • /
    • 2024
  • The document discusses the regeneration of Partisil/Partisphere ion-exchange columns in chromatography. It mentions that column efficiency can diminish with use due to the accumulation of sample and/or mobile phase impurities at the head of the column. This can lead to a change in back pressure, lower column efficiency, and sometimes a change in selectivity. The document outlines a procedure that may restore column performance. The document also provides everyday practices to enhance the lifetime of a column. These include using only high-purity HPLC solvents and buffers, using freshly prepared mobile phases and buffers, filtering mobile phases to remove particulates, using appropriate sample clean-up procedures, using a guard column or pre-column filter, and working within the pressure and flow rate limitations of the column. For the regeneration of Partisil/Partisphere SAX, SCX, WAX, and WCX columns, the document suggests passing 20 column volumes of various mobile phases through the column. These include a buffer wash, distilled water, an acid wash, a chelating wash, a methanol wash, and a buffer for separation. The document emphasizes that not all of these wash steps are required for every column clean-up and that some chromatographers require only a combination of certain steps.

  • PDF

Comparative Evaluation of Selective Media for Isolation of Bifidobacterium Species in Human Fecal Sample (인체 분변에서 Bifidobacterium species의 선택적 분리를 위한 배지 비교)

  • Saeyoun Shin;Sejong Oh
    • Journal of Dairy Science and Biotechnology
    • /
    • v.42 no.1
    • /
    • pp.9-17
    • /
    • 2024
  • This study aimed to evaluate the appropriateness of MRS-C (0.05% L-cystein; pH 5) and BHI-CM (0.05% L-cystein, 0.5% mucin) agars for the selective isolation of bifidobacteria in fecal samples compared to blood-liver-NPNL (BL-NPNL) agar. Over 200 isolated colonies were characterized morphologically and biochemically. Genomic DNA was extracted from pure cultures of the isolated strains, followed by PCR amplification of the 16S rRNA gene. Bifidobacterium longum and B. animalis were selectively isolated from MRS-C agar and Lactobacillus acidophilus and Enterococcus avium were also isolated. B. longum, B. faecale, and B. animalis were isolated from feces on BHI-CM agar; however, different Bacteroides strains (including Bac. fragilis, Bac. kiribbi, Bac. ovatus, Bac. koreensis, and Bac. salyersiae) were also detected. BL-NPNL agar successfully isolated B. longum and Bacillus, while other Bifidobacterium and Bacteroides species could not grow owing to the presence of antibiotics in the medium. The use of antibiotics in a medium can enhance the selectivity; however, antibiotics may inhibit the growth of certain bacteria in a sample. Hence, adjusting pH or adding non-antibiotic nutrients to the medium is more advantageous, than relying on antibiotics.