• Title/Summary/Keyword: sample selectivity

Search Result 99, Processing Time 0.027 seconds

Unbiasedness or Statistical Efficiency: Comparison between One-stage Tobit of MLE and Two-step Tobit of OLS

  • Park, Sun-Young
    • International Journal of Human Ecology
    • /
    • v.4 no.2
    • /
    • pp.77-87
    • /
    • 2003
  • This paper tried to construct statistical and econometric models on the basis of economic theory in order to discuss the issue of statistical efficiency and unbiasedness including the sample selection bias correcting problem. Comparative analytical tool were one stage Tobit of Maximum Likelihood estimation and Heckman's two-step Tobit of Ordinary Least Squares. The results showed that the adequacy of model for the analysis on demand and choice, we believe that there is no big difference in explanatory variables between the first selection model and the second linear probability model. Since the Lambda, the self- selectivity correction factor, in the Type II Tobit is not statistically significant, there is no self-selectivity in the Type II Tobit model, indicating that Type I Tobit model would give us better explanation in the demand for and choice which is less complicated statistical method rather than type II model.

Localized formation of porous silicon usin gdoping concentration selectivity (도핑농도의 선택도를 이용한 국부적 다공질 실리콘의 형성)

  • 이주혁;김성진;이성필;이철진;최복길;박천만;심관수
    • Proceedings of the IEEK Conference
    • /
    • 1998.06a
    • /
    • pp.465-468
    • /
    • 1998
  • For porous silicon layer to be used as active layer in various devices, it is necessary to be formed locally along with a designed pattern on the wafer. However, there is still no suitable masking layer to withstand against the high concentration of HF for a time of some minutes up to some hours during the anodic process effectively. In this work, we investigated the property of selectivity between p$^{+}$ and n layers to form localized porous silicon even without a mask by the difference of the anodic I-V characteristics on the doping level and doping type. The width of the pattern made in the sample was 2mm, and the formed porous silicon layer was observed by SEM to see the morphology on the cross section below the surface. As the results, it was found that the selectivity was reasonable for the pattern size over 100.mu.m.m.

  • PDF

Phonological Characteristics of Early Vocabulary in Young Children with Cleft Palate (구개열 아동의 초기 어휘에 나타난 음운 특성 연구)

  • Ha, Seunghee
    • Phonetics and Speech Sciences
    • /
    • v.6 no.2
    • /
    • pp.65-71
    • /
    • 2014
  • The purpose of this study was to investigate whether young children with cleft palate differ from those of noncleft typically developing children in terms of expressive vocabulary size, phonological characteristics and lexical selectivity. A total of 12 children with cleft palate and 12 noncleft children who were matched by age and gender participated in the study. The groups were compared by size of expressive vocabulary reported on Korean version of MacArthur-Bates Communicative Development Inventories and the number of different words, consonant inventory, the percentage of words beginning with obstruents and vowels, nasal, and glottal sounds, and the percentage of words which do not include obstruents in a language sample. Also, correlation analysis were performed to examine the relationship between measures on size of expressive vocabulary and phonological characteristics. The results showed that expressive vocabulary size and consonant inventory for children with cleft palate produced significantly smaller than those for noncleft children. Children with cleft palate produced significantly more words beginning with vowel or which do not include obstruents, and fewer words beginning with obstruents than noncleft children. The two groups showed different results on significant correlations between measures on size of expressive vocabulary and phonological characteristics indicating that children with cleft palate show different lexical selectivity from their noncleft peers. The results suggest that children with cleft palate aged 18-30 months demonstrate a slower rate of lexical and phonological development compared with their noncleft peers and they develop lexical selectivity reflecting cleft palate speech. The results will have a clinical implication on speech-language intervention for young children with cleft palates.

Analysis of Agrochemical Residues in Tobacco Using QuEChERS Method by GC-MS/MS

  • Lee, Jeong-Min;Jang, Gi-Chul;Hwang, Keon-Joong
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.29 no.2
    • /
    • pp.132-139
    • /
    • 2007
  • This study was performed to apply the more rapid and accurate sample preparation, and the high selectivity and sensitivity of the analyte detection by gas chromatography-triple quadrupole mass spectrometry (GC-MS/MS). QuEChERS (quick, easy, cheap, effective, rugged and safe) method was validated for 49 agrochemicals in the CORESTA Agrochemical Advisory Committee guide and amenable to GC-MS/MS determination. In QuEChERS method, the effects of sorbents (PSA, $C_{18}$ and GCB) and matrix of the analytes in tobacco types (flue-cured, burley and oriental) were investigated. MS/MS acquisition provided high specificity and selectivity for agrochemicals and low limit of quantification. QuEChERS by using PSA alone and the matrix-matched standards gave good recoveries and RSD values in three types of tobaccos. QuEChERS method was no needed to be complex clean-up procedure and would be used as the fast and easy method for agrochemical residue analysis in tobacco.

Full validation of high-throughput bioanalytical method for the new drug in plasma by LC-MS/MS and its applicability to toxicokinetic analysis

  • Han, Sang-Beom
    • Proceedings of the Korean Society of Toxicology Conference
    • /
    • 2006.11a
    • /
    • pp.65-74
    • /
    • 2006
  • Modem drug discovery requires rapid pharmacokinetic evaluation of chemically diverse compounds for early candidate selection. This demands the development of analytical methods that offer high-throughput of samples. Naturally, liquid chromatography / tandem mass spectrometry (LC-MS/MS) is choice of the analytical method because of its superior sensitivity and selectivity. As a result of the short analysis time(typically 3-5min) by LC-MS/MS, sample preparation has become the rate- determining step in the whole analytical cycle. Consequently tremendous efforts are being made to speed up and automate this step. In a typical automated 96-well SPE(solid-phase extraction) procedure, plasma samples are transferred to the 96-well SPE plate, internal standard and aqueous buffer solutions are added and then vacuum is applied using the robotic liquid handling system. It takes only 20-90 min to process 96 samples by automated SPE and the analyst is physically occupied for only approximately 10 min. Recently, the ultra-high flow rate liquid chromatography (turbulent-flow chromatography)has sparked a huge interest for rapid and direct quantitation of drugs in plasma. There is no sample preparation except for sample aliquotting, internal standard addition and centrifugation. This type of analysis is achieved by using a small diameter column with a large particle size(30-5O ${\mu}$m) and a high flow rate, typically between 3-5 ml/min. Silica-based monolithic HPLC columns contain a novel chromatographic support in which the traditional particulate packing has been replaced with a single, continuous network (monolith) of pcrous silica. The main advantage of such a network is decreased backpressure due to macropores (2 ${\mu}$m) throughout the network. This allows high flow rates, and hence fast analyses that are unattainable with traditional particulate columns. The reduction of particle diameter in HPLC results in increased column efficiency. use of small particles (<2 urn), however, requires p.essu.es beyond the traditional 6,000 psi of conventional pumping devices. Instrumental development in recent years has resulted in pumping devices capable of handling the requirements of columns packed with small particles. The staggered parallel HPLC system consists of four fully independent binary HPLC pumps, a modified auto sampler, and a series of switching and selector valves all controlled by a single computer program. The system improves sample throughput without sacrificing chromatographic separation or data quality. Sample throughput can be increased nearly four-fold without requiring significant changes in current analytical procedures. The process of Bioanalytical Method Validation is required by the FDA to assess and verify the performance of a chronlatographic method prior to its application in sample analysis. The validation should address the selectivity, linearity, accuracy, precision and stability of the method. This presentation will provide all overview of the work required to accomplish a full validation and show how a chromatographic method is suitable for toxirokinetic sample analysis. A liquid chromatography/tandem mass spectrometry (LC-MS/MS) method developed to quantitate drug levels in dog plasma will be used as an example of tile process.

  • PDF

Sample Preparation and Nucleic Acid-based Technologies for the Detection of Foodborne Pathogens (식중독균의 검출을 위한 시료전처리 및 핵산기반의 분석기술)

  • Lim, Min-Cheol;Kim, Young-Rok
    • Food Engineering Progress
    • /
    • v.21 no.3
    • /
    • pp.191-200
    • /
    • 2017
  • There have been great efforts to develop a rapid and sensitive detection method to monitor the presence of pathogenic bacteria in food. While a number of methods have been reported for bacterial detection with a detection limit to a single digit, most of them are suitable only for the bacteria in pure culture or buffered solution. On the other hand, foods are composed of highly complicated matrices containing carbohydrate, fat, protein, fibers, and many other components whose composition varies from one food to the other. Furthermore, many components in food interfere with the downstream detection process, which significantly affect the sensitivity and selectivity of the detection. Therefore, isolating and concentrating the target pathogenic bacteria from food matrices are of importance to enhance the detection power of the system. The present review provides an introduction to the representative sample preparation strategies to isolate target pathogenic bacteria from food sample. We further describe the nucleic acid-based detection methods, such as PCR, real-time PCR, NASBA, RCA, LCR, and LAMP. Nucleic acid-based methods are by far the most sensitive and effective for the detection of a low number of target pathogens whose performance is greatly improved by combining with the sample preparation methods.

Selective separation of Strontium in the solution containing Calcium by Supported Liquid Membrane (함침형 액막을 이용한 Calcium 함유 용액으로부터 Strontium의 선택적 분리)

  • Choi, Young-Woo;Moon, Seung-Hyeon;Lee, Chang-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.24 no.1
    • /
    • pp.9-15
    • /
    • 1999
  • In order to separate $Sr^{2+}$ selectively from environmental sample solutions containing $Ca^{2+}$, supported liquid membranes(SLM) were prepared and their characteristics of separation were investigated. The contents of carriers, DC18C6 and DNNS, in SLM affected the permeabilities of metal ions and selectivities of $Sr^{2+}$. The selectivity of $Sr^{2+}$ reached to 93.3% in a SLM with 0.1 M DC18C6 and 25 mM DNNS. When the ratio of $Sr^{2+}$ to $Ca^{2+}$ concentration in the feed solution was in the range of 1/25 to 1/50, the selectivity of $Sr^{2+}$ was greater than 90 %. Therefore, it is considered that the SLM prepared in this study is capable of treating environmental sea-water samples for strontium measurement.

  • PDF

Hybrid Estimation Method for Selecting Heterogeneous Image Databases on the Web (웹상의 이질적 이미지 데이터베이스를 선택하기 위한 복합 추정 방법)

  • 김덕환;이석룡;정진완
    • Journal of KIISE:Databases
    • /
    • v.30 no.5
    • /
    • pp.464-475
    • /
    • 2003
  • few sample objects and compressed histogram information of image databases. The histogram information is used to estimate the selectivity of spherical range queries and a small number of sample objects is used to compensate the selectivity error due to the difference of the similarity measures between meta server and local image databases. An extensive experiment on a large number of image data demonstrates that our proposed method performs well in the distributed heterogeneous environment.

TEM Specimen Preparation Method of Gibbsite Powder for Quantitative Structure Analysis (정량 구조 분석을 위한 Gibbsite 분말의 TEM 시편 준비법)

  • Kim, Young-Min;Jeung, Jong-Man;Lee, Su-Jeong;Kim, Youn-Joong
    • Applied Microscopy
    • /
    • v.32 no.4
    • /
    • pp.311-317
    • /
    • 2002
  • There is great requirement on the TEM specimen preparation method with particle size selectivity as a prerequisite for the quantitative structure analysis on the materials such as gibbsite powder, which generally forms a large agglomerate and shows a variation of transition process depending on their sizes. In this experiment, we made an attempt to give a methodology for the TEM specimen preparation of powder with the size selectivity. After mixing 1 wt% gibbsite powder with ethanol solvent, gibbsite suspension was prepared by application of ball-milling and ultrasonification with addition of 0.25 vol% dispersion agent, Darvan C, which was diluted into distilled water by the ratio 1:19. Appling the static sedimentation method to gibbsite suspension after estimation of the sedimentation time by the measurement of accumulative concentration variation, we acquired TEM specimens with well-dispersed and size selected gibbsite particles in nm scale. Overall picture of each sample was taken by SEM and morphology of each dispersed particle was imaged by TEM. Raw and processed gibbsite powders were also examined by XRD to investigate whether they were suffered from phase change during the process or not.

Cyclicality of Inter-Industry Wage Gaps and Segmented Labor Market Hypotheses (산업간 임금격차의 경기변동상 변화 패턴과 분단노동시장 가설)

  • Shin, Donggyun
    • Journal of Labour Economics
    • /
    • v.26 no.3
    • /
    • pp.77-114
    • /
    • 2003
  • Analyses of the special data sets constructed from the National Longitudinal Survey of Youth and the Panel Study of Income Dynamics reveal that, compared with an annual wage measure, survey week wages are significantly counter-cyclically biased due to selecting workers with strong labor market attachment. We also find that survey week wages are more counter-cyclically biased in high-wage industries than in low-wage industries, that is, inter-industry gaps of survey week wages are counter-cyclically biased. Unlike existing longitudinal studies, the current study concludes that real wages are much more procyclical in high-wage industries than in low-wage industries, which is attributed to our adoption of annual wages that is less subject to the selectivity bias. Our finding is consistent with the empirical regularity that real wages are much more procyclical for men than for women, as men are overrepresented in industries with greater real wage procyclicalities. Overall, current results do not support the predictions of segmented labor market theories for the cyclicality of real wages.

  • PDF