• Title/Summary/Keyword: sample injection method

Search Result 168, Processing Time 0.029 seconds

A study on the flatness of automotive torque-angle sensors (자동차 토크앵글센서(TAS)의 평면 정밀도에 관한 연구)

  • Yoon, Sean-Jhin;Cho, Yong-Moo
    • Design & Manufacturing
    • /
    • v.12 no.2
    • /
    • pp.11-15
    • /
    • 2018
  • In this study, we proposed three analysis methods to calculate the flatness of torque-angle sensors (TAS). We introduced two statistical and one geometrical methods in evaluating the precision of the flat plane in the axis direction for TAS. To verified the results, we fabricated TAS and a reference sample using a injection molding machine, mold, polyester as a raw material. We measured ($x_i$, $y_i$) position using 3D contact automated system and applied three analysis methods developed for TAS and a reference sample to see the feasibility. While each analysis method has its own pros and cons, the analysis using the shortest optimal distance was the most precise technique for the flatness evaluation of TAS components.

Determination of eugenol in Eugenia caryophyllata by high-performance Liquid chromatography with photodiode array detection and method validation (HPLC-PDA를 이용한 정향(Eugenia caryophyllata) 중의 eugenol 분석법 확립 및 검증)

  • Yun, Hyeong-Jun;Yun, So-Mi;Lee, Myoung-Heon;Son, Seong-Wan
    • Korean Journal of Veterinary Research
    • /
    • v.48 no.1
    • /
    • pp.9-16
    • /
    • 2008
  • A method for the quantification of eugenol in the medicinal herb Clove was developed and validated. For preparation of sample solutions clove was dried at $60^{\circ}C$ for 2h and ground by mixer and extracted with 95% ethanol for shaking extraction. The elutes were analyzed by HPLC system included a reversed phase column, a isocratic mobile phase of 60% methanol and PDA detector set at 280 nm. Calibration graphs were linear with very good correlation coefficients ($r^2>0.9999$) from $0.0125~1{\mu}g/ml$. The limit of detection per sample injection ($20{\mu}l$) was $0.81ng/{\mu}l$ and limit of quantification was $2.47ng/{\mu}l$. The method showed good intra-day precision (%RSD 0.08 ~ 0.27%) and inter-day precision (%RSD 0.32 ~ 1.19%).

Effect on Fear of Injection Procedures and Radiation Risk Recognition on Patients Characteristics Undergo Spinal Nerve Block (척추 신경 차단술 환자 특성이 주사시술의 공포감과 방사선의 위험 인식에 미치는 영향)

  • Cha, Jin-Young;Seoung, Youl-Hun
    • Journal of radiological science and technology
    • /
    • v.45 no.2
    • /
    • pp.171-177
    • /
    • 2022
  • The purpose of this study was to investigate the effect of the characteristics of patients who underwent spinal nerve block on the fear of injection and the risk of radiation. Subjects were 137 patients (67 males, 70 females) who visited the Department of Anesthesiology and Pain Medicine in Cheongju. The method was conducted as a research study using a total of 28 questionnaires consisting of patient characteristics, experience characteristics of nerve block surgery, nerve block fear scale, and radiation risk perception scale. The reliability of the questionnaire response was secured with a Cronbach's alpha coefficient of 0.6 or higher. For statistical analysis, correlation was tested by descriptive statistics, frequency analysis, independent sample T-test, and Pearson and Spearman correlation coefficients by measurement scale and factor. As a result, the fear scale of nerve block was significantly higher in women than in men (p<0.05). The fear scale of nerve block injection was significantly higher in the first-visit patients than in the second-visited patients (p<0.05). However, there was no significant difference among all variables in radiation risk perception. In conclusion, patients undergoing spinal nerve block were more aware of the fear of injection than the risk of radiation exposure during the procedure.

A Study on Quantitative Method of Piperine in Pure Ground Black Pepper (후추중의 Piperine 정량법에 관한 연구)

  • 고종명
    • Journal of Food Hygiene and Safety
    • /
    • v.10 no.3
    • /
    • pp.169-174
    • /
    • 1995
  • Piperine, component of pure ground black pepper, has strong stimulative and hot. Analytical method for piperine was developed by high performance liquid chromatography. Analytical conditions are as follows, mobile phase is 70% methanol, detector UV 343 nm (0.05 AuFs), column is Novapak 5 C18 (15 cm $\times$ 4.6mm), flow rate is 1.0ml/min, chart speed is 0.25 cm/min and injection volume is 20 ul. Analytical results are as follows that relative standard deviation is 1.15%, calibration curve is y=170473.1x-7848.5 (R2=0.999) that shows good linearity. Standard solution of piperine is stable up to 10 hr and content of piperine in pureground black pepper is 4.97$\pm$0.86% Retention time of piperine in HPLC method is about 7 min. Therefore, the developed HPLC method including simple pretreatment of sample will be contribute to quality mangement.

  • PDF

Determination of Ammonia-N in Environmental Water by Air-segmented FIA

  • Feng, Yong-Lai;Tian, Li-Ching;Wang, Wei;Wu, Qiao-Znen
    • Analytical Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.787-792
    • /
    • 1995
  • A method for determination of ammonia-N in environmental water by air-segmented flow injection analysis using the colour reaction of phenol and sodium hypochlorite with ammonia was described in this paper. When the reaction temperature is $70^{\circ}C$ and the reaction residence time is 5 minutes, a sample frequency of $60-90h^{-1}$ can be achieved. The detection limit and relative deviation are $0.05mg.ml^{-1}$ and 4%, respectively. The recovery of this method is 96 - 110%, and the determination results of the method are greatly agreement with standard colorimetric method.

  • PDF

Effect of Coexisting Ions on Electrokinetic Injection in Capillary Electrophoresis Analysis (모세관 전기영동 분석에서 계면 동전기 주입에 미치는 공존 이온의 영향)

  • Lee, Kwang-Woo;Jeon, Ji-Young;Lee, Kwang-Pill
    • Analytical Science and Technology
    • /
    • v.9 no.1
    • /
    • pp.35-42
    • /
    • 1996
  • A rapid analytical method based on capillary electrophoresis is described for the determination of trace anions in high-purity chemicals which is used to prevent corrosion demage in nuclear power plants. Separations are carried out at 20kV using trimethylsilane-coated fused-silica capillary ($70cm{\times}50$ or $75{\mu}m$ i.d.) with the electrolyte of 5mM Chromate(pH=8). Detection was achieved using on-column indirect photometry at 254nm. The simultaneous analysis of inorganic anions, chloride, nitrate, sulfate, azide and phosphate was performed using methods of hydrodynamic(>1ppm) and / or electrokinetic(<1ppm) injection. The results of studies on the coexisting anions on analyte ions shows that peak responses of analyte in hydrodynamic injection is constant without effect of coexisting anions, but those of analysis in electrokinetic injection is strongly dependant upon the kind of coexisting anions and its ionic mobility. The analyte enrichment rate, hence peak response, is positive relationship with the resistance of the sample solution. Thus, appropriate measures, such as standard addition or internal standard technique, must be used to account for differences in conductance of standard and sample solutions.

  • PDF

Effects of Ojeoksan extracted by varied extraction method in HA-induced model of blood stasis (煎湯方法의 變化에 의한 五積散 물추출액이 Hydrocortisone acetate로 유발한 瘀血病態에 미치는 효과)

  • Seo, Bu-Il;Kim, Mi-Ryeo;Park, Ji-Ha;Ji, Seon-Yeong
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.14 no.1
    • /
    • pp.182-189
    • /
    • 2001
  • This study was performed to compare the effect of Ojeoksan which have extracted by varied extractor(press extractor : PE, pressless extractor : PLE, short acting extractor : SE) on model of blood stasis in rats, Except for the normal group, hydrocortisone acetate(HA;25mg/kg in ethanol. IM) to induce experimental blood stasis model for 1 weeks and each extract of Ojeaksan was administrated after 1hr following HA injection for 1week. We measured the hematocrit, the platelet count, the prothrombin time, levels of fibrinogen in rats' blood, The sample Ⅰ(Ojeoksan extracted by PE) group showed significant decrease of hematocrit. prothrombin time and significant increase of the platelet count, levels of fibrinogen in comparison with those of the control group, The sample Ⅱ(Ojeaksan) extracted by PLE) group showed significant decrease of hematocrit and significant increase of levels of fibrinogen in comparison with those of the control group. Administration of the sample Ⅲ(Ojeaksan extracted by SE) group showed significant decrease of hematocrit and significant increase of the platelet count, levels of fibrinogen in comparison with those of the control group.

  • PDF

Experimental Study for Removing Artificial Patinas of Bronze Sculpture by Nd:YAG Laser Cleaning System (청동 조형물의 인공 파티나 제거를 위한 Nd:YAG 레이저 적용 실험 연구)

  • Park, Chang-Su;Cho, Nam-Chul
    • Journal of the Korean institute of surface engineering
    • /
    • v.46 no.5
    • /
    • pp.197-207
    • /
    • 2013
  • In the midst of increasing importance of modern cultural assets, especially, most modern bronze objects are exposed to outdoor environment, and as the objects are corroded steadily due to environmental factors the objects lost their original colors on the surface. We performed artificial patinas on the bronze sample per each color of red, black and green and checked cuprite and tenorite which are detected from actual bronze corrosion by analyzing the components. In addition, we applied the existing corrosion removal methods of grinder and sand blaster on a similar sample of bronze mirror per injection pressure and performed comparative analysis on the result with Nd:YAG laser. As a result of Nd:YAG laser cleaning artificial patina from bronze samples, all of the patinas were removed by laser wavelength 1064 nm better than 532 nm. Upon applying to a similar sample of bronze mirror, the artificial patina could be selectively removed from substrates without surface damage when Nd:YAG laser was conducted other than the existing removal method, and so it showed the possibility of application.

Speciation Analysis of Arsenic Species in Surface Water (수중의 비소 종 분리 분석)

  • Jeong, Gwan-Jo;Kim, Dok-Chan
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.6
    • /
    • pp.621-627
    • /
    • 2008
  • In this study, a technique of speciation and determination of the trace inorganic arsenic(As(III) and As(V)) in water sample using HPLC-DRC-ICP-MS has been developed. Isocratic mobile phase of 10 mM ammonium nitrate and 10 mM ammonium phosphate monobasic was used and methanol(5 v/v%) was used as flushing solvent. Selection of the best flow rate of reaction gas, O$_2$, and optimization of the parameters such as pH and flow rate of mobile phase, and injection volume of sample for the separation and detection of arsenic species were carried out. The oxygen flow rate of 0.5 mL/min, pH of 9.4 and flow rate of 1.5 mL/min of mobile phase, and injection volume of sample of 100 $\mu$L were found to be the best parameters for the speciation and determination of arsenic species. The analytical features of the method were detection limit 0.10 and 0.08 $\mu$g/L, precision(RSD) 4.3% and 3.6%, and recovery 95.2% and 96.4% for As(III) and As(V), respectively. Analysis time was 4 minutes per sample. Linear calibration graphs with r$^2$ = 0.998 were obtained for both As(III) and As(V). Speciation analysis of arsenic species in the raw water samples collected from the tributary streams to Han River and main stream of Paldnag were performed by the proposed method. The concentrations of As(III) ranged from 0.10 to 0.22 $\mu$g/L and As(V) concentrations ranged from 0.44 to 1.19 $\mu$g/L, and 93.5% of total arsenic was found to be As(V).

Development of an Auto Dilution Unit of Substrate Solutionfor a Flow Injection Type Biosensor (흐름주입식 바이오센서용 기질용액 자동희석 장치 개발)

  • Song, D.B.;Jung, H.S.;Jung, D.H.;Kim, S.T.
    • Journal of Biosystems Engineering
    • /
    • v.31 no.5 s.118
    • /
    • pp.443-448
    • /
    • 2006
  • For development of an on-line monitoring unit of fermentation process, an auto dilution unit based on traditional chemical and biological analytical method was developed and the performance was evaluated. The dilution unit was constructed with two syringe pumps and flow direction change valves and fully automated. Total delivery volume of two pumps using distilled water was measured to confirm the operating stability And diluted concentrations of three substrate solutions (glucose, lactic acid, ethanol) were compared with a standard method with a high performance liquid chromatograph (glucose, lactic acid) and gas chromatograph (ethanol). Relative error values of total delivery volume of the pumps were below 3% and standard deviation values were 0.003 (n=5). Relative error values of diluted concentration of the dilution unit measurements were below 2% with 1/10 of dilution ratio and 70, $80{\mu}{\ell}$ of sample volume conditions for glucose and lactic acid, 1/30 of dilution ratio and $70{\mu}{\ell}$ of sample volume conditions for ethanol, respectively. In case of the ethanol, cause of the evaporative characteristics, the relative error values showed over 5% whole experimental conditions.