• Title/Summary/Keyword: safety tests

Search Result 2,751, Processing Time 0.027 seconds

Performance Tests of a High Capacity Buffer Coupling System using a Hydraulic Device (유압 장치를 이용한 철도 연결기용 고용량 충격완충기의 성능시험)

  • Kim, Namwook;Park, Yeong-il
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.1
    • /
    • pp.33-40
    • /
    • 2016
  • Coupling systems under train's collision should take the impact by absorbing the impact energy caused from the collision, so the systems are very important parts for the safety of the trains. However, it is not easy to evaluate the performance of the system because it requires a huge testing facility, which is able to control the impact and to handle many safety issues. In this paper, test results are provided, which are obtained from collision tests of a single train having a coupling system in the front, and the results are analyzed in order to understand the characteristics and the dynamic behaviors of energy absorbing materials in the coupling system, such as a hydraulic buffer, and two rubber buffers. The results show that the force of each component could be empirically described by the compression displacement and velocity. The analyzed results will be applied to simulation models, and advanced studies wouuld be available if the simulation models are well validated with the test results.

A Comparative Study on the Herbal Prescription and the Herbal Substance of Atractylodis Rhizoma Alba by HPLC analysis (한약제제 백출(白朮)과 한약재 백출에 대한 HPLC 분석 비교연구)

  • Cho, Hyun Joo;Jeon, Yoon Jae;Kim, Nam-Gil;Choi, Hyug-Yong
    • Herbal Formula Science
    • /
    • v.24 no.2
    • /
    • pp.71-79
    • /
    • 2016
  • Objectives : To verify the equivalence between Atractylodis Rhizoma Alba herbal prescription(HP-ARA) and Atractylodis Rhizoma Alba herbal sub stance(HS-ARA). Methods : Safety tests by microbial regulation and heavy metal analysis (total heavy metal, Pb, As) and a stability test by long term shelf test for HP-ARA according to notification of the Ministry of Food and Drug Safety were carried out. Then, multi component profile of HP-ARA and HS -ARA were analyzed by HPLC. Results : The safety and stability of HP-ARA confirmed by several tests. Correlation coefficient of equivalence of HP-ARA and ARA-HS showed 0.992. Conclusion : Based on this result of equivalence between HP-ARA and HS-ARA, HP-ARA can substitute HS-ARA used to make herbal medicines (herbal decoction, pills and powder).

A Study on the Fire Safety of a Hybrid Composite Train Carbody (하이브리드 복합재 철도차량 차체의 화재 안전성 평가연구)

  • Kim, Jung-Seok;Lee, Duk-Hee; Jung, Woo-Sun;Cho, Sea-Hyun
    • Composites Research
    • /
    • v.21 no.4
    • /
    • pp.1-6
    • /
    • 2008
  • This paper explains fire safety tests of a hybrid composite train carbody with carbon/epoxy sandwich bodyshell and stainless steel underframe. In this study, a large scale mock-up was used to evaluate the fire safety of the composite train carbody. The test was conducted to the bare composite carbody mock-up without interior facilities and the fully equipped one. Tile fire propagation and temperature distribution of the carbon/epoxy bodyshell and the glass phenol interior panels was evaluated under the real fire accident scenario. The test scenario was based on the DaeGu subway fire accident. From the tests, both the surface temperature of the interiors and the composite bodyshell wore lower than tile ignition temperature. In addition, the fire spread along the surface of the interiors and bodyshell was not occurred.

A Software Update Technique for Aircraft Missiles based on MIL-STD-1760 (MIL-STD-1760 기반 항공기용 유도탄 소프트웨어 업데이트 기법)

  • Lee, Seungyoun;Kim, Sungkwon;Lee, Hyunah;Cho, Dongsik
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.21 no.5
    • /
    • pp.649-657
    • /
    • 2018
  • It is essential that weapons which are mounted on aircraft need to prove its reliability and safety during its developments. A guided missile should have high reliability and safety throughout various tests which are including ground tests, captive flight tests, detailed technical tests and operational tests. In these various tests, it is vital that software of each component in the guided missile should be easily updated in order to correct algorithms or errors. In this paper, we propose a software update technique based on MDTP(mass data transfer protocol) which are defined in MIL-STD-1760. The proposed techniques have the following advantages: First, software of each unit in a weapon can be updated through a test equipment without disassemble a guided missile. Second, development periods for a software update can be reduced by reusing MDTP. Third, we can easily maintenance of the software because it is based on standard. We proved its efficiency and validity through experiments. Therefore, the proposed technique should be effectively utilized for software update of a weapon mounted on an aircraft during development processes.

Structural Model Test for Strength Performance Evaluation of Fairlead Chain Stopper Installed on MW Class Floating Type Offshore Wind Turbine (메가와트급 부유식 해상풍력발전기용 페어리드 체인 스토퍼의 강도 성능평가를 위한 구조 모형 시험)

  • Chang-Yong Song
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.3
    • /
    • pp.421-431
    • /
    • 2023
  • Recently, the destructive power of typhoons is continuously increasing due to the influence of global warming. In a situation where the installation of floating wind turbines is increasing around the world, concerns about the huge loss and collapse of floating offshore wind turbines due to strong typhoons are deepening. Regarding to the safe operation of the floating offshore wind turbine, the development of a new type of disconnectable mooring system is required. A new fairlead chain stopper considered in this study is devised to more easily attach or detach the floating offshore wind turbine with mooring lines comparing to other disconnectable mooring apparatuses. In order to investigate the structural safety of the initial design of fairlead chain stopper that can be applied to MW-class floating type offshore wind turbine, scale-down structural models were produced using a 3-D printer and structural tests were performed on the models. For the structural tests of the scale-down models, tensile specimens of acrylonitrile butadiene styrene material that was used in the 3-D printing were prepared, and the material properties were evaluated by performing the tensile tests. The finite element analysis of fairlead chain stopper was performed by applying the material properties obtained from the tensile tests and the same load and boundary conditions as in the scale-down model structural tests. Through the finite element analysis, the structural weak parts on the fairlead chain stopper were reviewed. The structural model tests were performed considering the main load conditions of fairlead chain stopper, and the test results were compared to the finite element analysis. Through the results of this study, it was possible to experimentally verify the structural safety of the initial design of fairlead chain stopper. It is also judged that the study results can be usefully used to improve the structural strength of fairlead chain stopper in a detailed design stage.

A Study of Biocompatibility of Acupuncture's Metal Materials - Focused on Biological Character (2) - (침 금속재료에 대한 생체적합성 연구 - 생물학적 특성을 중심으로(2) -)

  • Jung In-Tae;Kang Jung-Won;Baek Yong-Hyeon;Lee Sang-Hoon;Lee Jae-Dong;Choi Do-Young
    • The Journal of Korean Medicine
    • /
    • v.26 no.2 s.62
    • /
    • pp.166-175
    • /
    • 2005
  • Objecitve: To present criteria for acupuncture standardization, which will improve the quality of acupuncture and secure safety, through studies of the biocompatibility of acupuncture needles. Methods: Acupuncture needles distributed in Korea were studied. Acute poisonous tests and pyrogenicity materials tests were executed to study the biocompatibility of acupuncture needles. Results & Conclusions: All 3 brands of acupuncture needles commonly distributed in Korea were found suitable for medical use, through acute poisonous tests and pyrogenicity materials tests. However, the medical instrument standards of the Korea Food and Drug Administration for acupuncture lack criteria concerning acute poisonous tests and pyrogenicity materials tests. The criteria for these tests should be standardized in order to secure the biocompatibility of acupuncture needles.

  • PDF

Inspections on the Food Safety of Pheasant and Mallard as a Meat Resource (식육자원(食肉資源)으로서의 꿩과 청둥오리 고기의 안전성(安全性) 검사(檢査))

  • Lee, Hun Jun;Oh, Hong Rock
    • Korean Journal of Agricultural Science
    • /
    • v.21 no.1
    • /
    • pp.28-36
    • /
    • 1994
  • Studies on the food-safety of pheasant and mallard, which belong to wild fowl as new meat resources. were carried out. The results were summarized as follows : 1. Food poisoning bacteria including Salmonella spp, was not detected from the inspections of small intestine, cecum, and rectum. 2. Parasite inspection tests on blood, feces, digestive organ, and thoracic organs were negative. 3. Antibiotic residues from the carcass muscle by simplified disk methods were not detected. 4. Seven different pesticide residue tests, such as DDT and BHT, on the muscle and liver were negative. 5. Four different kinds of toxic heavy metals such as Cd were much lower than the permissible concentration. Studies on the food safety tests and inspections from the pheasant and mallard were revealed that from taking this new food resources, the toxicities would be very low for the human health by the direct influences.

  • PDF

Do Various Respirator Models Fit the Workers in the Norwegian Smelting Industry?

  • Foereland, Solveig;Robertsen, Oeystein;Hegseth, Marit Noest
    • Safety and Health at Work
    • /
    • v.10 no.3
    • /
    • pp.370-376
    • /
    • 2019
  • Background: Respirator fit testing is a method to assess if the respirator provides an adequate face seal for the worker. Methods: Workers from four Norwegian smelters were invited to participate in the study, and 701 respirator fit tests were performed on 127 workers. Fourteen respirator models were included: one FFABE1P3 and 11 FFP3 respirator models produced in one size and two silicone half masks with P3 filters available in three sizes. The workers performed a quantitative fit test according to Health and Safety Executive 282/28 with 5-6 different respirator models, and they rated the respirators based on comfort. Predictors of overall fit factors were explored. Results: The pass rate for all fit tests was 62%, 56% for women, and 63% for men. The silicone respirators had the highest percentage of passed tests (92-100%). The pass rate for the FFP3 models varied from 19-89%, whereas the FFABE1P3 respirator had a pass rate of 36%. Five workers did not pass with any respirators, and 14 passed with all the respirators tested. Only 63% passed the test with the respirator they normally used. The mean comfort score on the scale from 1 to 5 was 3.2. The respirator model was the strongest predictor of the overall fit factor. The other predictors (age, sex, and comfort score) did not improve the fit of the model. Conclusion: There were large differences in how well the different respirator models fitted the Norwegian smelter workers. The results can be useful when choosing which respirators to include in respirator fit testing programs in similar populations.

Design models for predicting the resistance of headed studs in profiled sheeting

  • Vigneri, Valentino;Hicks, Stephen J.;Taras, Andreas;Odenbreit, Christoph
    • Steel and Composite Structures
    • /
    • v.42 no.5
    • /
    • pp.633-647
    • /
    • 2022
  • This paper presents the results from reliability analyses of the current Eurocode 4 (EN 1994-1-1) and AISC 360-16 design models for predicting the resistance of headed stud shear connectors within profiled steel sheeting, when the ribs are oriented transverse to the supporting beam. For comparison purposes, the performance of the alternative "Luxembourg" and "Stuttgart" model were also considered. From an initial database of 611 push-out tests, 269 cases were included in the study, which ensured that the results were valid over a wide range of geometrical and material properties. It was found that the current EN 1994-1-1 design rules deliver a corrected partial safety factor γM* of around 2.0, which is significantly higher than the target value 1.25. Moreover, 179 tests fell within the domain of the concrete-related failure design equation. Notwithstanding this, the EN 1994-1-1 equations provide satisfactory results for re-entrant profiled sheeting. The AISC 360-16 design equation for steel failure covers 263 of the tests in the database and delivers 𝛾M*≈2.0. Conversely, whilst the alternative "Stuttgart" model provides an improvement over the current codes, only a corrected partial safety factor of 𝛾M*=1.47 is achieved. Finally, the alternative "Luxembourg" design model was found to deliver the required target value, with a corrected partial safety factor 𝛾M* between 1.21 and 1.28. Given the fact that the Luxembourg design model is the only model that achieved the target values required by EN 1990, it is recommended as a potential candidate for inclusion within the second generation of Eurocodes.

Thermal and Vibration Analysis of TR Module Structural Model for Environmental Test Evaluation (환경시험 평가를 위한 TR 모듈 구조모델의 열/진동 해석)

  • Dong-Seok Kang;Jong-Pil Kim;Yuri Lee;Sung-Woo Park;Jin-Ho Roh
    • Journal of Aerospace System Engineering
    • /
    • v.18 no.4
    • /
    • pp.96-101
    • /
    • 2024
  • The Synthetic Aperture Radar (SAR) is equipped with a Transmitter/Receiver (TR) module, which serves as the signal transmission and reception unit for acquiring image data. The TR module generates significant heat during signal generation and amplification, potentially degrading performance or causing mission failure. Furthermore, launch and operational environments may result in structural damage to the components. Thus, assessing the thermal and structural safety of the TR module through thermal and vibration tests is essential to guarantee its safety. Safety assessments can be verified through environmental tests prescribed in MIL-STD-883. This paper explores the thermal and structural safety characteristics of the TR module by simulating test environments using finite element analysis prior to conducting environmental tests.