• Title/Summary/Keyword: runoff reduction

Search Result 339, Processing Time 0.033 seconds

Reduction of Suspended Solids in First Flush from a Building Rooftop using Various Media (여과재를 활용한 건물옥상유출 초기빗물의 부유물질 저감)

  • Kim, Seongbeom;Lee, Wontae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.4
    • /
    • pp.214-219
    • /
    • 2017
  • We analyzed the water quality of first flush and rainfall runoff from a building rooftop, and investigated the removal of suspended solids (SS) in first flush using various media to develop a first flush filtration system. Particle size distribution exhibited most of particles in first flush from the rooftop ranged from 10 to 30 ${\mu}m$. SS concentrations maxed in 10~20 min and decreased afterwards. Dissolved organics and inorganic materials in runoff also showed highest levels in first flush (10 min). Filtration tests using anthracite (AC), polyurethane (PU), polypropylene (PP) showed about 50% of SS removal during the first 10 min operation, but the removal rates dramatically decreased after 20 min of filtration. Based upon the results from rinse and run cycle tests, only AC could achieve nice cycles without distinct decease of SS removal. SS removal rates increased with higher depth of media bed and lower flowrate. The system achieved over 50% of SS removal with a media depth of 30 cm and flowrate < 12 L/min.

Analysis of Non-point Pollution Source Removal Efficiencies according to Rainfall Characteristics in Low Impact Development Facilities with Vegetation (식생이 적용된 비점오염 저감시설의 강우 특성에 따른 효율 분석)

  • Ku, Soo-Hwan;Im, Jiyeol;Oa, Seong-Wook;Gil, Kyungik
    • Journal of Korean Society on Water Environment
    • /
    • v.33 no.3
    • /
    • pp.247-255
    • /
    • 2017
  • This research was conducted to analyze removal efficiencies of non-point pollution source (NPS) in low impact development (LID) facilities with vegetation. In this research, removal efficiencies of NPS were calculated using rainfall monitoring data for 5 years in grassed swale (GS) and vegetative filter strip (VFS). TSS was greater than other pollutants, and it ranged 11.9 ~ 351.7 mg/L in GS and 12.8 ~ 350.7 mg/L in VFS. Outflow EMCs were reduced than inflow EMCs, overall removal efficiencies of NPS were 67 ~ 86% in GS and 63 ~ 91% in VFS. 50 % reduction efficiency of rainfall runoff was observed between inflow and outflow in each LID facility. TSS removal efficiency in GS and VFS was correlated with rainfall characteristics. The rainfall for TSS removal efficiency over 50% was determined about 31 mm, 34 mm and average rainfall intensity was 3.0 mm/hr, 3.9 mm/hr in GS and VFS. Therefore, GS and VFS were regarded effective LID facilities as removal of pollutants and rainfall runoff. Also, this research result can be used as an important data for management of NPS.

Analysis of runoff reduction and storage capacity in permeable pavement parking lot (투수성 주차장에서의 강우 유출저감 및 저류용량 분석)

  • Jung, Yongjun;Min, Kyungsok
    • Journal of Wetlands Research
    • /
    • v.19 no.3
    • /
    • pp.296-302
    • /
    • 2017
  • Generally, a parking lot is constructed using asphalt or concrete. Such materials are impermeable, which means that a parking lot will directly release pollutants to any nearby water system during a rainfall event. An increased quantity of nonpoint source pollutants harms the ecohydrological system and causes further environmental damage leading to dysfunctional water circulation systems. Therefore, there is an urgent need for the design and application of Low Impact Development (LID) systems that allow more effective prevention of water circulation problems and management of nonpoint source pollution. This study aims to support such efforts by analyzing a permeable paver parking lot constructed using one of the LID techniques and comparing it to a conventional one in terms of the concentration of pollutants, nonpoint source pollution load and runoff rainfall lag effects during a rainfall event; it could serve as a reference for the construction of permeable paver parking lots in the future.

Determination of EMC and MFFn Rainfall Runoff in Songcheon, Doam Lake Watershed (도암호 유역 송천에서의 강우유출수 분석을 통한 EMC와 초기세척비율 (MFFn) 산정)

  • Kwon, Hyeokjoon;Kim, Jonggun;Lim, Kyoungjae;Kim, Dongjin;Hong, Eunmi
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.62 no.4
    • /
    • pp.13-22
    • /
    • 2020
  • The Doam Lake watershed has a significant impact on the downstream water system due to nutrients and sediment outflow during rainfall caused by steep slopes, soil losses, and fertilization. These non-point sources are unclear in the discharge area and are affected by land use patterns, soil characteristics, and topographical features of the watershed. Therefore, this study conducted rainfall monitoring from July to October 2019 in Songcheon upstream of the Doam Lake watershed, one of the non-point pollution source management areas. Then, after analyzing rainfall runoff, Event Mean Concentration (EMC) and Mass First Flush ratio (MFFn) were calculated to compare and analyze the characteristics of rainfall and the non-point pollutant discharge. As a result of the analysis, it showed various non-point pollutant emission characteristics for each rainfall event. In addition, the concentration of EMC and the MFFn were affected by the average rainfall intensity and the maximum rainfall intensity, and were not significantly affected by the number of antecedent drying days. In the future, it is expected that effective non-point source reduction measures and management measures according to rainfall intensity through continuous monitoring and analysis will be needed.

Assessment of Seasonal Variations in the Treatment Efficiency of Constructed Wetlands

  • Reyes, Nash Jett DG.;Geronimo, Franz Kevin F.;Choi, Hyeseon;Jeon, Minsu;Kim, Lee-Hyung
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.231-231
    • /
    • 2020
  • Unlike conventional treatment technologies, the performance of nature-based facilities were susceptible to seasonal changes and climatological variabilities. This study evaluated the effects of seasonal variables on the treatment performance of constructed wetlands (CWs). Two CWs treating runoff and discharge from agricultural and livestock areas were monitored to determine the efficiency of the systems in reducing particulates, organics, and nutrients in the influent. For all four seasons, the mean effluent suspended solids concentration in the agricultural CW (ACW) increased by -2% to -39%. The occurrence of algal blooms in the system during summer and fall seasons resulted to the greatest increase in the amount of suspended materials in the overlying water. unlike ACW, the livestock CW (LCW) performed efficiently throughout the year, with mean suspended solids removal amounting to 61% to 68%. Algal blooms were still present in LCW seasonally; however, the constant inflow in the system limited the proliferation of phytoplankton through continuous flushing. The total nitrogen (TN) and total phosphorus (TP) removal efficiencies in ACW were higher during the summer (21% to 25%) and fall (8% to 21%) seasons since phytoplankton utilize nitrogen and phosphorus during the early stages of phytoplankton blooms. In the case of LCW, the most efficient reduction in TN (24%) and TP (54%) concentrations were also noted in summer, which can be attributed to the favorable environmental conditions for microbial activities. The mean removal of organics in ACW was lowest during summer season (-52% to 35%), wherein the onset of algal decay triggered a relative increase in organic matter and stimulate bacterial growth. The removal of organics in LCW was highest (54 % to 55%) during the fall and winter seasons since low water temperatures may limit the persistence of various algal species. Variations in environmental conditions due to seasonal changes can greatly affect the performance of CW systems. This study effectively established the contributory factors affecting the feasibility of utilizing CW systems for treating agricultural and livestock discharges and runoff.

  • PDF

Evaluation on the suspended solids and heavy metals removal mechanisms in bioretention systems

  • Geronimo, Franz Kevin F.;Maniquiz-Redillas, Marla C.;Hong, Jungsun;Kim, Lee-Hyung
    • Membrane and Water Treatment
    • /
    • v.10 no.1
    • /
    • pp.91-97
    • /
    • 2019
  • Application of bioretention systems in Korea is highly considered due to its minimal space requirements, appropriateness as small landscape areas and good pollutant removal and peak hydraulic flow reduction efficiency. In this study, the efficiency of two lab-scale bioretention types having different physical properties, media configuration and planted with different shrubs and perennials was investigated in reducing heavy metal pollutants in stormwater runoff. Type A bioretention systems were planted with shrubs whereas type B were planted with perennials. Chrysanthemum zawadskii var. latilobum (A-CL) and Aquilegia flabellata var. pumila (A-AP) respectively were planted in each type A bioretention reactors while Rhododendron indicum linnaeus (B-RL) and Spiraea japonica (B-SJ), respectively were planted in each type B bioretention reactors. Results revealed that the four lab-scale bioretention reactors significantly reduced the influent total suspended load by about 89 to 94% (p<0.01). Type B-RL and B-SJ reactors reduced soluble Cr, Cu, Zn, and Pb by 28 to 45% that were 15 to 35% greater than the soluble metal reduction of type A-CL and A-AP reactors, respectively. Among the pollutants, total Cr attained the greatest discharged fraction of 0.52-0.81. Excluding the effect of soil media, total Pb attained the greatest retention fraction in the bioretention systems amounting to 0.15-0.34. Considering the least discharge fraction of heavy metal in the bioretention system, it was observed that the bioretention systems achieved effectual reduction in terms of total Cu, Zn and Pb. These findings were associated with the poor adsorption capacity of the soil used in each bioretention system. The results of this study may be used for estimating the maintenance requirements of bioretention systems.

Experimental Evaluation of Particulate-matter Filtration Performance of a Bottom Ash-Silica Sand Mixture (석탄 저회-규사 필터의 입자상물질 여과 성능 실험적 평가)

  • Lee, Dong-Hyun;Lee, Hong-Kyoung;Lee, Yun-Jae;An, Jaehun
    • Journal of the Korean Geotechnical Society
    • /
    • v.38 no.6
    • /
    • pp.41-47
    • /
    • 2022
  • Permeable pavement technology allows the penetration of rainfall into the roadbed, thereby reducing surface runoff and enhancing water quality. The water quality can be improved by adding a filter layer to the permeable pavement. This study analyzes the permeability performance and particulate-matter removal efficiency of a bottom ash-silica sand filter. The performances of five filters with bottom ash and silica sand as the basic materials were evaluated on particulate matter sized 60 ㎛ or smaller. The pure silica sand sample and pure bottom ash sample delivered an average removal efficiency of around 70%. The removal efficiency of the mixed sample was approximately 90%, exceeding the recommended reduction rate (80%) at non-point pollution reduction facilities. In future work, the filter performance should be further verified on permeable pavement.

A Determination Method of a Rainwater Retention-Pumping System Combination for Runoff Control from Building Roof Area (지붕면 유출제어를 위한 빗물의 저장-펌프 시스템 조합 결정방안)

  • Kim, Young-Jin;Han, Moo-Young
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.495-499
    • /
    • 2008
  • This study developed a determination method for a rainwater retention-pumping combination system for roof runoff control. The outflow and stored water volume in the rainwater system was simulated using a water balance equation. Its result is presented in the TPP (Tank capcity-Peak outflow-Pumping rate) curves for rainfall return periods. In a case study on reduction of the peak flow rate of 100-year return period to 5-year in Seoul, The range of pumping rate for $100m^2$ roof area is determined as $0{\sim}25{\ell}$/min. Additionally, retention volume of $8.5{\sim}10m^3$ can be combined with the pumping rate range. That is to say an effective combination of a retention-pumping system capacity can be determined from a system of $8.5m^3$ tank with $25{\ell}$/min to $10m^3$ tank without pump. Using the TPP curves, engineers can determine the effective combination range of retention & pumping system capacity. Furthermore, that can be helpful to decide a detail system capacity for field condition.

  • PDF

A Study on Urban Inundation Prediction Using Urban Runoff Model and Flood Inundation Model (도시유출모형과 홍수범람모형을 연계한 내수침수 적용성 평가)

  • Tak, Yong Hun;Kim, Jae Dong;Kim, Young Do;Kang, Boosik
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.36 no.3
    • /
    • pp.395-406
    • /
    • 2016
  • Population and development are concentrated by urbanization. Consequently, the usage of underground area and the riverside area have been increased. By increasing impermeable layer, the urban basin drainage is depending on level of sewer. Flood damage is occurred by shortage of sewer capacity and poor interior drainage at river stage. Many of researches about flood stress the unavailability of connection at the river stage with the internal inundation organically. In this study, flood calculated considering rainfall and combined inland-river. Also, using urban runoff model analyze the overflow of sewer. By using results of SWMM model, using flood inundation analysis model analyzed internal drainage efficiency of drainage system. Applying SWMM model, which results to flood inundation analysis model, analyzes internal drainage efficiency of drainage system under localized heavy rain in a basin of the city. The results of SWMM model show the smoothness of internal drainage can be impossible to achieve because of the influence of the river level and sewer overflow appearing. The main manholes were selected as the manhole of a lot of overflow volume. Overflow reduction scenarios were selected for expansion of sewer conduit and instruction retention pond. Overflow volume reduces to 45% and 33~64% by retention pond instruction and sewer conduit expansion. In addition, the results of simulating of flood inundation analysis model show the flood occurrence by road runoff moving along the road slope. Flooded area reduces to 19.6%, 60.5% in sewer conduit expansion scenarios.

Reduction of Pollutant Concentrations in Urban Stormwater Runoff by Settling (침강에 의한 도시 강우 유출수 오염물질 저감 특성 분석)

  • Seo, Dongil;Kim, Jaeyoung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.4
    • /
    • pp.210-218
    • /
    • 2016
  • The pollutant removal efficiencies of stormwater runoff by settling were analyzed using field samples collected in 4 different raining events in a test bed installed in the Gwanpyung-Cheon stream in Daejeon. A 1.8 m high with 30 cm diameter cylindrical settling device was used for the settling test by measuring concentration of TSS, TP and TN for time and height. The pollutants removal rate was relatively high in the first 4 hours while 24 hours seem to be necessary to reach steady state in pollutant concentrations. However, there were no considerable differences in concentrations for height at a given time. This indicates most of particulate pollutant in the test seems to show independent settling with no interference to each other. Much part of particle sizes were distributed in the range of $10{\sim}100{\mu}m$. Average particulate fractions of TP and TN were estimated as 52.4% and 23.5%, respectively. This results explain why TN is difficult to remove by simple settling. This study indicates that a simple settling can provide effective method to remove significant amount of TSS and TP effectively and this can be used to protect urban river water quality.