• 제목/요약/키워드: runoff loading

검색결과 168건 처리시간 0.028초

농촌유역의 강우사상별 농업 비점원오염물질 유출특성 (Characteristics of Agricultural Non-point Source Pollutants by Rainfall Events in Rural Watersheds)

  • 김진호;한국헌;이종식
    • 한국물환경학회지
    • /
    • 제24권1호
    • /
    • pp.69-77
    • /
    • 2008
  • This study was conducted to know the characteristics of agricultural non-point source pollutants runoff by rainfall events at the upper catchment of Goseong reservoir in Gonjy city, Chungnam Province. For this study, the monitoring sites of the research catchment were set nineteen during the research period (between June 2005 and October 2006). Average runoff coefficient were observed 0.51 in 2005, 0.71 in 2006, respectively. The correlation coefficient (r) between the rainfall and peak-flow was investigated 0.787. By rainfall events, the water quality of the sites were shown like this : BOD 0.555~9.60 mg/L, T-N 0.01~13.50 mg/L, T-P 0.002~2.952 mg/L, and SS N.D~820.0 mg/L. The strong rainfall intensity was the most important factor of the soil erosion. The gabs of the arithmetic mean concentrations and the flow weighted mean concentrations were observed as the followings : BOD 0.0~29.2%, T-N 0.1~11.4%, T-P 0.4~95.2%, and SS 1.7~57.0% in 2005, and BOD 1.0~11.9%, T-N 0.7~7.3%, T-P 9.9~36.5%, and SS 6.6~36.5% in 2006, respectively. The BOD pollution load was 2,117 kg (36% of the total BOD loading of survey periods) while, T-N was 3,209.0 kg (27.9% of the total T-N loading of survey periods), T-P was 136.4 kg (37.4% of the total T-P loading of survey periods) and SS was 72,733.8 kg (51.8% of the total SS loading of survey periods) in the year 2005. In case of 2006, BOD load was 1,321.7, T-N was 2,845.8, T-P was 42.9, and SS was 16,275.8 kg, respectively.

강우시 비점오염원의 오염부하 특성 - 고구마 재배지를 대상으로 - (Loading Characteristics of Non-Point Source Pollutants by Rainfall - Case Study with Sweet Potato Plot -)

  • 강미아;조수현;최병우;윤영삼;이재관
    • 지질공학
    • /
    • 제19권3호
    • /
    • pp.365-371
    • /
    • 2009
  • 본 연구에서는 비점오염원의 효율적인 관리방안을 확립하기 위하여 단위재배지로부터의 오염물질 배출특성을 조사하였다. 무강우일수가 상대적으로 길었던 약 20%의 강우사상을 제외한 나머지 강우사상에 대해서는 강우량과 강우에 의한 유출수량의 상관성은 상관계수 0.92로 매우 높았으며, 유출수량이 유출계수에 미치는 영향인자로는 유출직전의 강우강도가 주요인자임을 알 수 있었다. 한편, 유출수로부터 발생하는 오염물질의 EMCs(유량가중평균농도)가 높은 강우사상의 결과로 무강우일수가 길었던 강우사상에서 무강우에 의해 건조된 토양의 영향에 기인한 것임을 알 수 있다. 유출수로부터 발생되는 TSS, BOD, COD, TN 및 TP 등의 부하량은 동일한 강우사상에서 유사한 경향을 나타내므로 부유물질을 제어함으로써 다른 오염물질의 제거도 가능할 것으로 추정된다. 따라서 강우량계급별 유출계수 만을 이용한 오염물질부하량은 많은 오차를 나타낼 것이며, 오염부하 예측시스템을 개발할 때에는 강우량, 무강우일수, 선행강우량 등을 인자로 고려한 재배지토양조건을 충분히 고려하여야 할 것이다.

청양-홍성간 도로에서의 초기강우에 의한 유출부하량 평가 및 기여율 산정 (Evaluation of Runoff Loads and Computing of Contribute ratio by First Flush Stormwater from Cheongyang-Hongseong Road)

  • 이춘원;강선홍;최이송;안태웅
    • 상하수도학회지
    • /
    • 제25권3호
    • /
    • pp.407-417
    • /
    • 2011
  • Nowadays, the high land use, mainly used for urbanization, is affecting runoff loads of non-point pollutants to increase. According to this fact, increasing runoff loads seems like to appear that it contributes to high ratio of pollution loads in the whole the pollution loads and that this non-point source is the main cause of water becoming worse quality. Especially, concentrated pollutants on the impermeable roads run off to the public water bodies. Also the coefficient of runoff from roads is high with a fast velocity of runoff, which ends up with consequence that a lot of pollutants runoff happens when it is raining. Therefore it is very important project to evaluate the quantity of pollutant loads. In this study, I computed the pollutant loadings depending on time and rainfall to analyze characteristics of runoff while first flush storm water and evaluated the runoff time while first flush storm water and rainfall based on the change in curves on the graph. I also computed contribution ratio to identify its impact on water quality of stream. I realized that the management and treatment of first flush storm water effluents is very important for the management of road's non-point source pollutants because runoff loads of non-point source pollution are over the 80% of whole loads of stream. Also according to the evaluation of runoff loads of first flush storm water for SS, run off time was shown under the 30 minute and rainfall was shown under the 5mm which is less than 20% of whole rainfall. These are under 5mm which is regarded amount of first flush storm water by the Ministry of Environment and it is judged to be because run off by rainfall is very fast on impermeable roads. Also, run off time and rainfall of BOD is higher than SS. Therefore I realized that the management of non-point source should be managed and done differently depending on each material. Finally, the contribution ratio of pollutants loads by rainfall-runoff was shown SS 12.7%, BOD 12.7%, COD 15.9%, T-N 4.9%, T-P 8.9%, however, the pollutants loads flowing into the steam was shown 4.4%. This represents that the concentration of non-point pollutants is relatively higher and we should find the methodical management and should be concerned about non-point source for improvement on water quality of streams.

여과형 비점오염 처리장치의 오염물질 제거특성 및 역세척 분석 (The Performance of Pollutant Removal Using Nonpoint Treatment Filtration Device and Analysis of the Filter Backwashing Effect)

  • 이준호;양승호;방기웅
    • 한국물환경학회지
    • /
    • 제31권5호
    • /
    • pp.523-532
    • /
    • 2015
  • Hydrocyclone is widely used in industry, for its simple design, high capacity, low maintenance and low operational cost. The objective of this study is to develop hydrocyclone coagulation and filtration system. The system is made of hydrocyclone ballasted coagulation with polyaluminium chloride silicate (PACS) and upflow filter to treat micro particles in urban storm runoff. Roadside sediment particles (< $200{\mu}m$) was mixed with tap water to make various turbid suspensions to simulate urban storm runoff. The filter cartridge was filled with polyethylene media system and ran 1hr per everyday and total operation time were 8.19hrs and backwashing everyday after end of operation. The operation condition of flowrate was $8.2{\sim}11.9m^3/day$ (mean $10.1m^3/day$) and surface overflow rate (SOR) based on filter surface area was $45.5{\sim}65.9m^3/m^2/day$ (mean $55.7m^3/m^2/day$). The range of PACS dosage concentration was 14.0~31.5 mg/L. As the results of operation, the range of removal efficiency of turbidity, SS were 81.0~95.8% (mean 89.5%) 81.8~99.0% (mean 91.4%), respectively. An increase of filtration basin retention time brought on increased of removal efficiency of turbidity and SS, and increase of SOR brought on decreased of removal efficiency. During the first flush in urban area, storm runoff have an high concentration of SS (200~600 mg/L) and the filtration bed becomes clogged and decreased of removal efficiency. Backwashing begins when the drainage pipe valve at the filtration tank bottom is completely open (backwashing stage 1). Backwashing stage 2 was using air bubbles and water jet washing the media for 5 mins and open the drainage valve. After backwashing stage 1, 2, 61.83~64.04%, 18.53~27.51% of SS loading was discharged from filtration tank, respectively. Discharged SS loading from effluent was 7.12~14.79% and the range of residual SS loading in fliter was 2.26~5.00%. The backwashing effects for turbidity, SS were 89.5%, 91.4%, respectively. The hydrocyclone coagulation and filtration with backwashing system, which came out to solve the problems of the costly exchange filter media, and low efficiency of removing micro particles of filter type nonpoint treatment devices, is considered as an alternative system.

강우유출수의 침투시 부하저감을 위한 경사관 침전장치의 효율평가 (Evaluation of Particle Removal Rate in Inclined-pipe Settling System for Stormwater Infiltration)

  • 김상래;김동근;문정수;한무영
    • 상하수도학회지
    • /
    • 제23권6호
    • /
    • pp.719-726
    • /
    • 2009
  • One of the alternative runoff management measures is on-site runoff mitigation, such as rainwater retention tank and infiltration facilities especially the latter that is possible to manage simultaneously runoff quality and quantity as a perspective of water-cycle. This study was conducted to develop a particle separator, inclined-pipe settling system, that could improve particle removal efficiency of road runoff as a pre-treatment device of stormwater infiltration. Solid particles larger than $100{\mu}m$ are separated by simple sedimentation; however, the significant amount of pollutants with a diameter less than $100{\mu}m$ remain in suspension. Without any treatment in that case of the runoff into infiltrate, groundwater would be deteriorated and also infiltration rate would be decreased by clogging. Therefore, we suggest optimal design parameters (inclined angle, pipe length, and surface loading rate) of inclined-pipe settling system which can be designed to effectively remove particles diameter smaller then $70{\mu}m$. Thus, the results showed TSS removal efficiency more than 80% with a particle diameter between $20{\mu}m$ and $70{\mu}m$, 100% above particle diameter $70{\mu}m$ for the inflow rate $0.018 m^3/m^2{\cdot}hr$ with pipe inclined at angle $15^{\circ}$.

철도지역의 비점오염원 유출특성 (Estimation of Runoff Characteristics of Nonpoint Pollutant Source in Railroad Area)

  • 이춘식;서규태;윤조희;권헌각;이재운;천세억
    • 한국환경과학회지
    • /
    • 제23권3호
    • /
    • pp.511-520
    • /
    • 2014
  • The MFFn(Mass first flush), EMCs(Event mean concentrations) and runoff loads were analyzed for various rainy events(monitoring data from 2011 to 2012) in transportation area(rail road in station). The pollutant EMCs by volume of stormwater runoff showed the BOD5 9.6 mg/L, COD 29.9 mg/L, SS 16.7 mg/L, T-N 3.271 mg/L, T-P 0.269 mg/L in the transportation areas(Railroad in station). The average pollutant loading by unit area of stormwater runoff showed the BOD5 $27.26kg/km^2$, COD $92.55kg/km^2$, SS $50.35kg/km^2$, T-N $10.13kg/km^2$ and T-P $10.13kg/km^2$ in the transportation areas. Estimated NCL-curve(Normalized cumulated-curve) was evaluated by comparison with observed MFFn. MFFn was estimated by varying n-value from 10% to 90% on the rainy events. The n-value increases, MFFn is closed to '1'. As time passed, the rainfall runoff was getting similar to ratio of pollutants accumulation. The result of a measure of the strength of the linear relationship between observed data and expected data under model was good.

주암호유역 산림기원 비점오염원물질과 주암호에 서식하는 조류번식간의 상관성 규명 (A study on the correlation between non-point source pollutants from the forest of Juam basin and algae bloom in the Juam lake.)

  • 김남종;신대윤
    • 환경위생공학
    • /
    • 제21권4호
    • /
    • pp.39-48
    • /
    • 2006
  • In Juam basin, the ratio of non-point pollution source among pollutant loading of basin was significantly high, since the utilization level of land was high. In addition, the most pollutants were not treated and flowed out. In this study, the correlation between non-point source pollutants from the forest area and increasing algae was investigated. 1. Chl-a concentration flowed out to runoff from forest area and stream water was low as $0.1{\sim}20.3{\mu}g/{\ell}$ and $0.1{\sim}9.3{\mu}g/{\ell}$, respectively, and chl-a concentration ($0.1{\sim}28.5{\mu}g/{\ell}$) of branch stream was higher $5{\sim}7$ times than that of runoff from forest area. 2. In correlation between runoff from forest area and Juam lake water, annual chl-a concentration of area front Juam dam was higher twice than forest area. 3. In runoff from forest area within Juam basin, flagellate, green, diatom and blue algae occupied $33.0{\sim}41.7%$, $22.2{\sim}30.8%$, $17.3{\sim}22.5%$ and $13.7{\sim}17.6%$, respectively. 4. In runoff from forest area, both green and diatom algae were maintained constantly irrespectively of season, and flagellate algae dominated since August. 5. In characteristics by forest tree types, four types algae were inhabited in mixed forest, and flagellate algae were higher in conifer and broadleaf forest than in other area. And green algae in herbaceous forest were higher than other area.

마령지구 필지 논으로부터 영농기 영양물질 수지와 유출부하량 (Nutrient Balance and Runoff Loading During Cropping Period from a Paddy Plot in Maryeong Irrigation District)

  • 최진규;구자웅;손재권;윤광식;조재영
    • 한국농공학회지
    • /
    • 제43권5호
    • /
    • pp.153-162
    • /
    • 2001
  • A study was carried out to investigate the water balance and losses of nutrients at a paddy plot located at the southern Korea. The observed amount of precipitation, irrigation, runoff, evapotranspiration and percolation for the experimental paddy plot during cropping period were 1,030, 566, 701, 551. and 310 mm for 1999 and 1.214, 413, 710, 682, and 234 mm for 2000 year, respectively. The measured input quantities of N and P into the paddy field during cropping period were 122 to 140 kg N $ha^-1$ and 29 to 30 kg $P_2O_5$ kg $ha^-1$ by chemical fertilizer, 20 to 28 kg N $ha^-1$ and 0.35 to 0.36 kg P $ha^-1$ by precipitation, and 26 to 35 kg N $ha^-1$ and 0.57 to 0.72 kg P$ha^-1$ by irrigation water. respectively. The output amounts of N and P from paddy field were measured as follows. They were 48 to 52 kg N $ha^-1$ and 1.1 to 1.6 kg P $ha^-1$by runoff water, and 9 to 12 kg N $ha^-1$ and 0.04 to 0.05 kg $ha^-1$ by percolation water. When the runoff losses of nutrients were compared to applied chemical fertilizer. it was found that 34.3 % to 42.6 % of nitrogen lost via runoff while runoff losses of phosphorus account for 3.8 % to 5.3 % of the total applied amount. When the ratio was calculated between nutrients losses by percolation water and the applied of chemical fertilizer, two year results showed 6.4 % to 9.8 % for the nitrogen and 0.1% to 0.2% phosphorus, respectively.

  • PDF

경안천 유역의 강우 시, 비 강우 시 난분해성 유기물질 유출 특성 (Runoff Characteristics of Refractory Organic Matters from Kyongan River Watershed during Rainfall Event and Dry Season)

  • 김태원;길경익
    • 한국물환경학회지
    • /
    • 제27권4호
    • /
    • pp.397-404
    • /
    • 2011
  • This research investigates the runoff characteristics of refractory organic matters from Kyongan river watershed. Samples were taken 27 times during dry season, 4 times during rain events and analyzed into flow rate, Dissolved Organic Carbon (DOC), Particulate Organic Carbon (POC), Refractory Dissolved Organic Carbon (R-DOC), Refractory Particulate Organic Carbon (R-POC). R-DOC during dry season was the lowest in winter and showed a rising tendency in spring and R-POC changes less than R-DOC. The mass loading of Refractory Total Organic Carbon (R-TOC) in summer takes approximately 80% of 1 year mass loading. During rainy season, EMC of R-DOC was similar to R-DOC in dry season. But maximum EMC of R-POC was 12 times higher than that of R-POC in dry season. Results of the survey show that enhanced management of R-DOC in dry season and R-POC in rainy season is needed.