• Title/Summary/Keyword: rpm

Search Result 3,991, Processing Time 0.036 seconds

MICROHARDNESS AND SURFACE ROUGHNESS OF SEALANT AND FLOWABLE COMPOSITE RESINS (치면열구전색제와 유동성 복합 레진의 미세 경도 및 표면 조도의 비교)

  • Yang, Kyu-Ho;Choi, Nam-Ki;Kim, Seon-Mi;Choi, Ji-Eun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.36 no.3
    • /
    • pp.440-447
    • /
    • 2009
  • This study was performed to compare the wear resistance of sealant and flowable resins for analyzing the effect of flowable resin as a sealant in preventive resin restorations. Specimens were made and Vicker's hardness number and surface roughness were measured. SEM observations of the polished and abraded surfaces were established. Kruskal-Wallis rank test and Mann-Whitney U test at the significant level of ${\alpha}$=0.05 were used. The following results were obtained: 1. The microhardness was decreased among groups in following order: Z350 (3M ESPE, U.S.A), Estelite (Tokuyama Dental, Japan) and Ultraseal (Ultradent, U.S.A). There were significant differences in all groups (p<0.0001). 2. The surface roughness was decreased among groups in following order: Ultraseal XT plus, Palfique Estelite LV and Filtek Z350 flowable. However, there is no statistically significant differences in roughness among Estellite, Z350 and Ultraseal at the significance level of ${\alpha}$=0.05, with p=0.116 3. SEM observation of the unworn and worn surfaces revealed the qualitative differences in the wear appearance among groups. The results in this study indicate that flowable resin is better than sealant in aspect of physical properties.

  • PDF

Development of an Solid Separation System for Pig Slurry (돈 슬러리용 고형물 분리시스템 개발)

  • 김민균;김태일;최동윤;백광수;박진기;양창범;탁태영
    • Journal of Animal Environmental Science
    • /
    • v.8 no.1
    • /
    • pp.9-16
    • /
    • 2002
  • This study was conducted to develope the new solid separating system which can be efficiently and economically removed the solid parts in high pollutants concentration of pig slurry. The pollutants concentration, BOD$_{5}$ , COD and SS of the slurry used in this study was 15,990($\pm$2,389)mg/l, 20,004($\pm$5,512)mg/l and 26,486($\pm$5,935)mg/l, respectively. After removal of solid part in slurry, the pollutants concentration, BOD$_{5}$, COD and SS was change into 5,617($\pm$690)mg/l, 5,553($\pm$633)mg/land 1,456($\pm$341)mg/l, respectively in the Fixed biological membrane tank. The reduction of the pollutants concentration of suspend liquid through membrane will be allowed to greatly improve the water purification by an Activated sludge method. This separating system consisted of a temporary storage, a circulating tank and a Fixed Biological membrane tank. A temporary storage which has a draining system of screw type and an aeration device played a tremendous role in draining the solid by filled an aeration of 0.3 l/min. A Fixed Biological membrane tank of which a styrofoam filled in a 2/3 volume as a Biological media was fixed by a stainless steel net (pore size : 0.5mm) to separate the liquid layer of influx in them. The separating system efficiency factors were the speed of screw motor, cycle number of slurries in a circulating tank and moisture contents of solid effluent through the screw path. Although the pollutants concentration was very variable in temporary storage, the final concentration of $BOD_5$ and SS, except COD of the suspended liquid in a Fixed biological membrane were not different regardless of cycle number of a circulating tank. Moisture contents of effluent from temporary storage was 73% under the speed 1 ppm of screw motor and 62% under the 1/4rpm of it.

  • PDF

ELISA of paragonimiasis in cat by crude and purified antigens of Paragonimus westermani (폐흡충(肺吸蟲)의 조(粗)항원과 정제(精製)항원에 의한 폐흡충(肺吸蟲)감염 고양이혈청의 면역효소반응(免疫酵素反應))

  • Lee, Ok-Ran;Chang, Jae-Kyung
    • Parasites, Hosts and Diseases
    • /
    • v.24 no.2
    • /
    • pp.187-193
    • /
    • 1986
  • Enzyme-linked immunosorbent assay(ELISA) using crude and affinity-purified antigens of adult worms of Paragonimus westermani was performed for infected cat sera with different worm burden, from preinfection to 18th week after infection. Crude antigen was used with supernatant of homogenated worms by freezing-thawing method, and the supernate was centrifuged for 1 hour at 10,000 rpm at $4^{\circ}C$. Affinity-purified antigen(antibody-bound antigen) was prepared from fractions(bound and unbound) of crude antigen by affinity chromatography on CNBr-activated sepharose 4B, and IgG as a ligand was prepared from paragonimiasis cat serum(6 months infected) obtained by ammonium sulfate ($40%{\sim}45%$ saturated) precipitation method. By SDS-PAGE, crude antigen showed 22 polypeptide fractions while purified antigen showed 4 fractions: 36, 400, 34, 700, 27, 600 and 11, 500 in molecular weights. All cats were divided into five groups($G_1-G_5$) by different worm burdens. The mean of recovered worms(${\pm}SD$) and the number of cats in each group are as follows: $G_1$, 2 worms(0) and 4 cats; $G_2$, 4.75 (${\pm}0.66$) and eight; $G_3$, 10.75(${\pm}1.92$) and four; $G_4$, 23.20(${\pm}3.43$) and five; $G_5$, 48(${\pm}12.63$) and five cats. The results were summarized as follows: 1. The antibody levels(OD value) increased by worm burden in $G_1$ to $G_4$ generally. However, individual antibody levels were not exactly related with worm burden in all groups, especially there was a wide difference in $G_4$ and $G_5$. These results suggested that the worm burden in $G_4$ (about $20{\sim}30$ worms) is enough to produce antibody maximum in cats of $2{\sim}3kg$ weight. 2. The antibody levels increased significantly(p<0.05) compared to control sera at the 3rd week in $G_1$ and $G_2$, at the 2nd week in $G_3$, and at the 1st week in $G_4$ and $G_5$. Especially in the 4th week, OD value increased more in $G_1$(p<0.01) and in $G_2$ to $G_5$(p<0.001). In the pattern of antibody levels by ELISA in each group, OD in $G_1$ increased to the 18th week continuously, in $G_2$ OD was maintained same after the 16th week, but in $G_3$ it decreased after the 16th week, and it was maintained same in $G_4$ and $G_5$ after the 14th week. 3. The antibody levels by ELISA with the affinity-purified antigen were higher than those with crude antigen in all groups generally. Especially, the difference of OD values between two antigens was larger from the 4th to the 10th week. In $G_1$ and $G_2$ OD with purified antigen was higher than that with crude one to the 18th week. It was also higher in $G_3$ than that with crude antigen to the 16th week and OD of $G_4$ and $G_5$ were higher before the 14th week than that with crude antigen, however became lower at the 16th week. Consequently, the antibody level in ELISA with affinity-purified antigen was more sensitive at the early weeks after infection and in light infection groups than that with crude antigen.

  • PDF

Physicochemical Characteristics of the Sorghum(Sorghum bicolor L. Moench) Powder following Low Temperature-Microparticulation (저온초미분쇄에 따른 수수가루의 이화학적 특성)

  • Kim, Hyun-Young;Seo, Hye-In;Ko, Jee-Yeon;Kim, Jung-In;Lee, Jae-Saeng;Song, Seuk-Bo;Jung, Tae-Wook;Kim, Ki-Young;Kwak, Do-Yeon;Oh, In-Seok;Jeong, Heon-Sang;Woo, Koan-Sik
    • The Korean Journal of Food And Nutrition
    • /
    • v.25 no.3
    • /
    • pp.656-663
    • /
    • 2012
  • Two sorghum(Sorghum bicolor L. Moench cv. Hwanggeumchal-susu and Miryang 3) samples were milled using different milling methods, and their physicochemical properties were tested. Particle size was classified into five groups such as pin mill and low temperature-microparticulation(LTM; 10,000, 20,000, 30,000, and 40,000 rpm). The water absorption index (WAI), water solubility index(WSI), and a rapid Visco analyzer(RVA) were used to examine particle size distribution and color differences. Particle size of sorghum flour prepared using LTM was lower than that prepared using a pin mill. Particle size was further reduced by successive dry milling of the LTM flour. Lightness of colored pigments increased when particle size decreased. The WAI of Miryang 3 pin milling(M1) flour was the lowest after LTM, and WSI was higher in the order of M2, M3, M4, and M5. LTM sorghum flour had significantly higher pasting viscosity, as determined using a rapid Visco analyzer. LTM Miryang 3 sorghum flour(M2~M5) flour showed lower breakdown viscosity and higher final viscosity compared to those of M1 flour, resulting in an increased setback value.

Soluble Interleukin-2 Receptor(sIL-2R) Levels in Patients Tuberculous Pleurisy VS Nontuberculous Pleurisy (결핵성 늑막삼출과 비결핵성 늑막삼출에서의 가용성 Interleukin-2 수용체의 농도)

  • Lim, Hyun-Oak;Ham, Jong-Yeol;Shim, Dae-Seok;Hwang, Young-Sil
    • Tuberculosis and Respiratory Diseases
    • /
    • v.41 no.2
    • /
    • pp.135-143
    • /
    • 1994
  • Background: The cell mediated immunity has an important role in the pathogenesis of tuberculosis. sIL-2R has been known as a sensitive marker of T lymphocyte activation Elevated serum levels of sIL-2R have been found in patients with lymphoproliferative disorders, organ transplantation, autoimmune diseases, and various granulomatous diseases. Elevated levels of sIL-2R have been also found in the serum and pleural fluid of the patients with tuberculosis. To evaluate the diagnostic value of sIL-2R in the differentiation of tuberculous pleurisy and nontuberculous pleurisy. We measured the level of sIL-2R in the sera and pleural fluids of 12 patients with tuberculous pleurisy and 32 patients with nontuberculous pleurisy. Method: Samples of pleural fluid and serum were centrifuged at 2500 rpm for 10 min to remove cell pellets. Soluble IL-2R was measured with a sandwitch enzyme immunoassay using the Cellfree(r) Interleukin-2 Receptor Test kit(T-cell science,Inc. Cambridge, MA). Results: The results obtained were as follows: 1) The sIL-2R level in pleural fluid of the patients with tuberculous pleurisy was higher than that of patients with nontuberculous pleurisy(P<0.005). 2) When the sIL-2R level above 5,000 u/ml in pleural fluid was used as the cut-off value to diagnose tuberculous pleurisy, it had a sensitivity of 84.6% and a specificity of 90.9%. 3) The sIL-2R level in the sera of the patients with tuberculous pleurisy was higher than that of patients with bacterial pleural effusions and normal control group(P<0.05) and there was no difference of levels compared with malignant pleural effusions and transudative pleural effusions(P>0.05). 4) In patients with tuberculous pleurisy, the mean concentration of sIL-2R in pleural fluid was higher than that in serum(P<0.005). Conclusion: These findings suggest that the measurement of elevated levels of pleural fluid sIL-2R in tuberculous pleurisy may be useful in the differential diagnosis between patients with tuberculous pleurisy and nontuberculous pleurisy.

  • PDF

Fully Automated Liquid Culture System Compared with Lowenstein-Jensen Solid Medium for Rapid Recovery of Mycobacteria in Sputums (완전 자동화된 액체배양법과 기존의 고체배양법을 이용한 객담 내 mycobacterium의 신속검출에 대한 비교)

  • Park, Seung-Kyu;Kim, Seung-Chul;Kim, Deuk-Mi;Lee, Chang-Woon;Kim, Young;Cho, Sang-Nae
    • Tuberculosis and Respiratory Diseases
    • /
    • v.53 no.6
    • /
    • pp.635-643
    • /
    • 2002
  • Background : The Aim of this study was to compare the recovery of mycobacteria from sputum samples of pulmonary tuberculosis patients using the MB/BacT rapid culture system(Organon Teknika, USA) with that obtained using Lowenstein-Jensen solid medium. Methods : The two culture systems were compared using sputum samples of 99 pulmonary tuberculosis patients. Culture media were incubated at $35-37^{\circ}C$ for six weeks in the MB/BacT system and for 12 weeks in Lowenstein-Jensen solid medium. Solid media were examined macroscopically once a week, and the MB/BacT system positive vials were unloaded from the machine as soon as possible after positive signal from the connected computer was detected Confirmation of growth for mycobacteria was done by Ziehl-Neelson stained smears. Isolates were identified to differentiate Mycobacterium tuberculosis from mycobacterium other than tuberculosis(MOTT) by phenotypic and molecular methods. Results : Of the sputum samples of the 99 patients, 58 samples were smear positive and 41 in negative smear. Mycobacteria were recovered from 67(67.7%) samples by using both culture systems. The yield with MB/BacT was higher than that with Lowenstein-Jensen [67(67.7%) vs. 52(52.5%), p<0.001]. Moreover, 15(15.2%) samples were positive only in the MB/BacT, whereas none of samples was positive only in Lowenstein-Jensen. In smear-positive and smear-negative samples, the recovery rate with MB/BacT was also higher than that with Lowenstein-Jensen [sputum-positive; 56/58(96.6%) vs. 46/58(79.3%), p=0.005, sputum-negative; 6/41(14.6%) vs. 5/41(12.2%), p<0.001]. The mean times to detection of Mycobacteria were 13.3 and 27.2 days with MB/BacT and Lowenstein-Jensen respectively(p<0.001). Conclusion : This results indicate that the the MB/BacT is more efficient and faster than Lowenstein-Jensen for the recovery of mycobacteria.

Experimental Research on the Power Improvement by Increasing Intake pressure in a 1.4 L Turbocharged CNG Port Injection Spark Ignition Engine (1.4L 급 터보 CNG 엔진에서 흡기압력 상승에 따른 출력 증대 효과에 관한 연구)

  • Lee, Jeong-Woo;Park, Cheol-Woong;Bae, Jong-Won;Kim, Chang-Gi;Lee, Sun-Youp;Kim, Yong-Rae
    • Journal of the Korean Institute of Gas
    • /
    • v.23 no.6
    • /
    • pp.90-96
    • /
    • 2019
  • Natural gas has been regarded as one of major alternative fuels, because of the increment of mining shale gas and supplying PNG(Pipeline Natural Gas) from Russia. Thus, it needs to broaden the usage of natural gas as the increasing its supplement. In this situation, application of natural gas on the transport area is a good suggestion to reduce exhaust emissions such as CO2(carbon dioxides) and soot from vehicles. For this reason, natural gas can be applied to SI(spark ignition) engines due to its anti-knocking and low auto-ignitibility characteristics. Recently, since turbocharged SI engine has been widely used, it needs to apply natural gas on the turbocharged SI engine. However, there is a major challenge for using natural gas on turbocharged SI engine, because it is hard to make natural gas direct injection in the cylinder, while gasoline is possible. As a result, there is a loss of fresh air when natural gas is injected by MPI (multi-point injection) method under the same intake pressure with gasoline-fueled condition. It brings the power reduction. Therefore, in this research, intake pressure was increased by controling the turbocharger system under natural gas-fueled condition to improve power output. The goal of improved power is the same level with that of gasoline-fueled condition under the maximum torque condition of each engine speed. As a result, the maximum power levels, which are the same with those of gasoline-fueled conditions, with improved brake thermal efficiency could be achieved for each engine speed (from 2,000 to 6,000 rpm) by increasing intake pressure 5-27 % compared to those of gasoline-fueled conditions.

COMPARISON OF SCREW-IN EFFECT FOR SEVERAL NICKEL-TITANIUM ROTARY INSTRUMENTS IN SIMULATED RESIN ROOT CANAL (모형 레진 근관에서 수종의 전동 니켈-티타늄 파일에 대한 screw-in effect 비교)

  • Ha, Jung-Hong;Jin, Myoung-Uk;Kim, Young-Kyung;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.4
    • /
    • pp.267-272
    • /
    • 2010
  • Screw-in effect is one of the unintended phenomena that occurs during the root canal preparation with nickel-titanium rotary files. The aim of this study was to compare the screw-in effect among various nickel-titanium rotary file systems. Six different nickel-titanium rotary instruments (ISO 20/.06 taper) were used: $K3^{TM}$ (SybronEndo, Glendora, CA, USA), $M_{two}$ (VDW GmbH, Munchen, Germany), NRT with safe-tip and with active tip (Mani Inc., Shioya-gun, Japan), ProFile$^{(R)}$ (Dentsply-Maillefer, Ballaigues, Switzerland) and ProTaper$^{(R)}$ (Dentsply-Maillefer, Ballaigues, Switzerland). For ProTaper$^{(R)}$, S2 was selected because it has size 20. Root canal instrumentations were done in sixty simulated single-curved resin root canals with a rotational speed of 300 rpm and single pecking motion. A special device was designed to measure the force of screw-in effect. A dynamometer of the device recorded the screw-in force during simulated canal preparation and the recorded data was stored in a computer with designed software (LCV-USE-VS, Lorenz Messtechnik GmbH, Alfdorf, Germany). The data were subjected to one-way ANOVA and Tukey's multiple range test for post-hoc test. P value of less than 0.05 was regarded significant. ProTaper$^{(R)}$ produced significantly more screw-in effects than any other instruments in the study (p < 0.001). $K3^{TM}$ produced significantly more screw-in effects than $M_{two}$, and ProFile$^{(R)}$ (p < 0.001). There was no significant difference among $M_{two}$, NRT, and ProFile$^{(R)}$ (p > 0.05), and between NRT with active tip and NRT with safe one neither (p > 0.05). From the result of the present study, it was concluded, therefore, that there seems significant differences of screw-in effect among the tested nickel-titanium rotary instruments. The radial lands and rake angle of nickel-titanium rotary instrument might be the cause of the difference.

The effects GeongshinhaeGihwan 1(GGT1) has on the hGHTg (human growth hormone transgenic) obese male rats' blood-antiobestic index (형질전환 비만모델 수컷 hGHTg rats에서 경신해지환(輕身解脂丸)이 혈중 항비만지표에 미치는 영향)

  • Jung, Yang-Sam;Tsung, Pei-Chin;Choi, Seung-Bae;Kim, Gyeong -Cheol;Shin, Soon-Shik
    • Herbal Formula Science
    • /
    • v.13 no.2
    • /
    • pp.1-16
    • /
    • 2005
  • Objectives: To find out the effects GGTl, an antiobestic drug widely used in clinics, has on the blood-antiobestic index and the toxicity index using the data from the hGHTg obese male rats. We looked closely into both of the two indices because GGTl antiobestic effect can happen not only by pharmacological action, but also by its toxicity. Also, we verified the difference in effect between GGTl and reductil (sibutramine), which has been approved by the FDA of the United States. Methods: After performing the experiments for 8 weeks on the hGHTg obese male rats divided into three groups: the control group, the GGTl group, and the reductil (RD) group, we anesthetized the rats with Diethyl ether and took a 3ml blood sample from the heart. Then, after coagulating the blood in room temperature by using the plasma separator, we centrifuged it for 25 minutes in 3,000rpm using the high-speed refrigerated centrifuge. We kept the separated plasma in a deep freezer at $-80^{\circ}C$, and repeatedly measured the antiobestic index and the toxicity index twice using the hematology biochemistry analyzer. Also, in order to judge the indirect toxicity index, we separated liver from kidney and observed them. Results: When we looked at the results of the analysis of covariance on the measuring elements related to the antiobestic index (TC, HDL, LDL, TG, and GLU), there was no significant difference among the groups in all measuring elements. Also, the results of the analysis of covariance on the two roups (RD group and GGTl group) showed that the p-values had no significant difference under the level of significance 0.05. When we looked at the result of the analysis of covariance on the measuring elements related to the toxicity index (GOT, GPT, GGT, CREA, UA, ALB, and TP), we could see that the p-values in GPT, ALB, and TP have a significant difference among the groups. Also, the results of the analysis of covariance about the measuring elements related to the toxicity index on both groups, RD group and GGTl group, showed no significant difference in the p-values of all of the measuring elements in the two groups, RD and GGTl group. Conclusions: In conclusion, through this experiment, the safety of GGTl has been approved, and although the verification on its medical effect has not been clearly approved, when we consider the fact that it belongs to the same group as reductil, an antiobestic drug approved by the FDA of the United States, we could indirectly verify that GGTl has an antiobestic effect. We believe that when doing a sample design for a future experiment, it needs to be performed on a greater sample size based on the power analysis that needs to be performed primarily in experiments, and a more accurate verification is needed through more systematic experiment plans.

  • PDF

Improvement of the Fishing Gear and Fishing Method of the East-Sea Trawl Fishery (동해구 트롤 어구어법의 개량)

  • 권병국;이주희;이춘우;김형석;김용식;안영일;김정문
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.37 no.2
    • /
    • pp.106-116
    • /
    • 2001
  • A serious of studies on the fishing gear and system of the East Sea trawl fishery was carried out to improve the fishing efficiency and the working conditions. As the first step of these studies, the fishing gear and system of the traditional East Sea trawl were checked in order to solve the some problems, such as the poor sheering efficiency of net mouth, the inconvenient fishing system of the side trawl and etc. And then the fishing system was reorganized from the side trawl into the stern trawl by setting up the net drum system on the stern deck, and introduction of two types of new designed nets, one for mainly the midwater trawl and the other for the bottom trawl. The results of the field experiment on the modified system and nets can be summarized as follows : 1. the modified system was well worked and could save the man-labour by about 80%. 2. The sheering efficiency of the improved net, A type was improved to 20 m height and 30 m width in the net mouth, and that of B type net, to 10 m height and 33 m width, compared with 1.5 m height and 15 m width in the traditional net. 3. Catch efficiency of pink shrimp in A or B type net was better about 3 or 5 times than that of traditional net, and in B net, for herring and other bottom fishes is better about 2 times than that of the traditional net.

  • PDF