• Title/Summary/Keyword: root point

Search Result 636, Processing Time 0.026 seconds

Morphometric Study of the Nerve Roots Around the Lateral Mass for Posterior Foraminotomy

  • Hwang, Jae-Chan;Bae, Hak-Geun;Cho, Sung-Won;Cho, Sung-Jin;Park, Hyung-Ki;Chang, Jae-Chil
    • Journal of Korean Neurosurgical Society
    • /
    • v.47 no.5
    • /
    • pp.358-364
    • /
    • 2010
  • Objective : Morphometric data on dorsal cervical anatomy were examined in an effort to protect the nerve root near the lateral mass during posterior foraminotomy. Methods : Using 25 adult formalin-fixed cadaveric cervical spines, measurements were taken at the lateral mass from C3 to C7 via a total laminectomy and a medial one-half facetectomy. The morphometric relationship between the nerve roots and structures of the lateral mass was investigated. Results from both genders were compared. Results : Following the total laminectomy, from C3 to C7, the mean of the vertical distance from the medial point of the facet (MPF) of the lateral mass to the axilla of the root origin was 3.2-4.7 mm. The whole length of the exposed root had a mean of 4.2-5.8 mm. Following a medial onehalf facetectomy, from C3 to C7, the mean of the vertical distance to the axilla of the root origin was 2.1-3.4 mm, based on the MPF. Mean vertical distances from the MPF to the medial point of the root that crossed the inferior margin of the intervertebral disc were 1.2-2.7 mm. The mean distance of the exposed root was 8.2-9.0 mm, and the mean angle between the dura and the nerve root was significantly different between males and females, at $53.4-68.4^{\circ}$. Conclusion : These data will aid in reducing root injuries during posterior cervical foraminotomy.

Biocompatibility of root-end filling materials: recent update

  • Saxena, Payal;Gupta, Saurabh Kumar;Newaskar, Vilas
    • Restorative Dentistry and Endodontics
    • /
    • v.38 no.3
    • /
    • pp.119-127
    • /
    • 2013
  • The purpose of a root-end filling is to establish a seal between the root canal space and the periradicular tissues. As root-end filling materials come into contact with periradicular tissues, knowledge of the tissue response is crucial. Almost every available dental restorative material has been suggested as the root-end material of choice at a certain point in the past. This literature review on root-end filling materials will evaluate and comparatively analyse the biocompatibility and tissue response to these products, with primary focus on newly introduced materials.

Design of a high-performance floating-point unit adopting a new divide/square root implementation (새로운 제산/제곱근기를 내장한 고성능 부동 소수점 유닛의 설계)

  • Lee, Tae-Young;Lee, Sung-Youn;Hong, In-Pyo;Lee, Yong-Surk
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.37 no.12
    • /
    • pp.79-90
    • /
    • 2000
  • In this paper, a high-performance floating point unit, which is suitable for high-performance superscalar microprocessors and supports IEEE 754 standard, is designed. Floating-point arithmetic unit (AU) supports all denormalized number processing through hardware, while eliminating the additional delay time due to the denormalized number processing by proposing the proposed gradual underflow prediction (GUP) scheme. Contrary to the existing fixed-radix implementations, floating-point divide/square root unit adopts a new architecture which determines variable length quotient bits per cycle. The new architecture is superior to the SRT implementations in terms of performance and design complexity. Moreover, sophisticated exception prediction scheme enables precise exception to be implemented with ease on various superscalar microprocessors, and removes the stall cycles in division. Designed floating-point AU and divide/square root unit are integrated with and instruction decoder, register file, memory model and multiplier to form a floating-point unit, and its function and performance is verified.

  • PDF

A Variable Latency Goldschmidt's Floating Point Number Square Root Computation (가변 시간 골드스미트 부동소수점 제곱근 계산기)

  • Kim, Sung-Gi;Song, Hong-Bok;Cho, Gyeong-Yeon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.9 no.1
    • /
    • pp.188-198
    • /
    • 2005
  • The Goldschmidt iterative algorithm for finding a floating point square root calculated it by performing a fixed number of multiplications. In this paper, a variable latency Goldschmidt's square root algorithm is proposed, that performs multiplications a variable number of times until the error becomes smaller than a given value. To find the square root of a floating point number F, the algorithm repeats the following operations: $R_i=\frac{3-e_r-X_i}{2},\;X_{i+1}=X_i{\times}R^2_i,\;Y_{i+1}=Y_i{\times}R_i,\;i{\in}\{{0,1,2,{\ldots},n-1} }}'$with the initial value is $'\;X_0=Y_0=T^2{\times}F,\;T=\frac{1}{\sqrt {F}}+e_t\;'$. The bits to the right of p fractional bits in intermediate multiplication results are truncated, and this truncation error is less than $'e_r=2^{-p}'$. The value of p is 28 for the single precision floating point, and 58 for the doubel precision floating point. Let $'X_i=1{\pm}e_i'$, there is $'\;X_{i+1}=1-e_{i+1},\;where\;'\;e_{i+1}<\frac{3e^2_i}{4}{\mp}\frac{e^3_i}{4}+4e_{r}'$. If '|X_i-1|<2^{\frac{-p+2}{2}}\;'$ is true, $'\;e_{i+1}<8e_r\;'$ is less than the smallest number which is representable by floating point number. So, $\sqrt{F}$ is approximate to $'\;\frac{Y_{i+1}}{T}\;'$. Since the number of multiplications performed by the proposed algorithm is dependent on the input values, the average number of multiplications per an operation is derived from many reciprocal square root tables ($T=\frac{1}{\sqrt{F}}+e_i$) with varying sizes. The superiority of this algorithm is proved by comparing this average number with the fixed number of multiplications of the conventional algorithm. Since the proposed algorithm only performs the multiplications until the error gets smaller than a given value, it can be used to improve the performance of a square root unit. Also, it can be used to construct optimized approximate reciprocal square root tables. The results of this paper can be applied to many areas that utilize floating point numbers, such as digital signal processing, computer graphics, multimedia, scientific computing, etc.

A Experimental Study on the Root Barrier Design of Joint of Panel Type Waterproofing Method by Considering the Growth Diagnosis of Root (식물뿌리의 생장특성을 고려한 패널형 방수공법의 조인트부 방근설계에 관한 실험적 연구)

  • Choi, Sung-Min;Choi, Soo Kyung;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2009.11a
    • /
    • pp.183-189
    • /
    • 2009
  • In this study, the growth diagnosis of root is analyzed through plant's auxanology point of view, and the inductive root barrier ability of panel type waterproofing method which is designed to deal with it, is confirmed positively through long term(2 years) mock-up test. Moreover, basic ideas for inductive root barrier design in joint is presented through this study. The experiment result for the root barrier of sealed A-type during 24 months, there were no damages found on the waterproofing layer. -urethane sealing material was used to apply for waterproofing of joint- for roots. As the result, it was confirmed that it is possible to maintain the root barrier of method through applying inductive root barrier design such as the installation of decreasing space of bearing power which considers the growth diagnosis of root, even if the root barrier was not secured.

  • PDF

A STUDY OF THE ROOT SURFACE AREA, ANATOMIC STRUCTURE AND LINEAR VARIATION OF THE ROOT SURFACE AREA OF THE MANDIBULAR SECOND MOLAR (하악 제2대구치 치근의 형태학적 구조 및 표면적에 관한 연구)

  • Chung, Hyung-Geun;Kwon, Young-Hyuk;Lee, Man-Sup
    • Journal of Periodontal and Implant Science
    • /
    • v.23 no.1
    • /
    • pp.159-169
    • /
    • 1993
  • The thirty six mandibular second molars, which were extracted because of hopeless tooth due to advanced periodontal disease, were measured the length of mesial and distal root and the distance from cementoenamel junction to root separation. The molars were cross-sectioned every 1.5 milimeter from cementoenamel junction to root apex perpendicular to long axis and each section was photographed, projected and measured with a calibrated Digital Curvi-Meter(Com Curvi-8. Japan). The root surface area (RSA), percentage of the RSA and the linear variation of the RSA were calibrated for each 1. 5 mm section. The results were as follows. 1. The mean length of the roots was 12. 98mm for mesial root, 11.84 mm for distal root. The mesial root was longer than distal root.(p<0.01) 2. The mean distance from the cementoenamel junction to the point at which the root separate from the root trunk was 3.82mm for the buccal furcation and 4.75mm for lingual furcation. The buccal root separation was coronal than the lingual root separation.(p<0.01) 3. The total root surface area was $317.78mm^2$. 4. The mean surface area of the root trunk was $150.06mm^2$ and averaged 42.54% of the total root surface area. 5. The mean root surface area was $88.79\;mm^2$ for the mesial root, $78.93mm^2$ for distal root, The mesial root surface area was wider than the distal root surface area.(p<0.05) 6. In comparision, the mean root trunk surface area of the mandibular 2nd molar was wider than that of mandibular 1st molar(p<0.01), but each root of 2nd molar was smaller than that of 1st molar(p<0.01).

  • PDF

Initial Point Optimization for Square Root Approximation based on Newton-Raphson Method (Newton-Raphson 방식의 제곱근 근사를 위한 초기값의 최적화)

  • Choi Chang-Soon;Lee Jin-Yong;Kim Young-Lok
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.43 no.3 s.345
    • /
    • pp.15-20
    • /
    • 2006
  • A Newton-Raphson Method for table driven algorithm is presented in this paper. We concentrate the approximation of square root by using Newton-Raphson method. We confirm that this method has advantages of accurate and fast processing with optimized initial point. Hence the selection of the fitted initial points used in approximation of Newton-Raphson algorithm is important issue. This paper proposes that log scale based on geometric wean is most profitable initial point. It shows that the proposed method givemore accurate results with faster processing speed.

A Case Study on the Vibration Characteristics of Tunnel Blasting in Igneous Rock (화성암반에서 터널발파 진동측정치의 분석에 관한 사례 연구)

  • 윤성현;안명석;이광열
    • Explosives and Blasting
    • /
    • v.21 no.1
    • /
    • pp.69-76
    • /
    • 2003
  • Test blasting has been performed with V-cut to investigate the characteristics. Blasting vibrations were measured at two directions, the proceed direction and side direction. Propagation characteristics were determined by regression analysis; square root scaled distance and cube root scaled distance with maximum charge per delay of the blast. Testing result, The cross point was 62m in the allowable vibration velocity of 3mm/sec and 46m In 5mm/sec. Also, vibration level with measuring point was highest and decayed fastest, adapting to cube root scaled distance, for the proceed direction on ground.

Feasibility of Ultrasound-Guided Lumbar and S1 Nerve Root Block: A Cadaver Study (초음파 유도하 요추 및 제1천추 신경근 차단술의 타당성 연구)

  • Kim, Jaewon;Park, Hye Jung;Lee, Won Ihl;Won, Sun Jae
    • Clinical Pain
    • /
    • v.18 no.2
    • /
    • pp.59-64
    • /
    • 2019
  • Objective: This study evaluated the feasibility of ultrasound-guided lumbar nerve root block (LNRB) and S1 nerve root block by identifying spread patterns via fluoroscopy in cadavers. Method: A total of 48 ultrasound-guided injections were performed in 4 fresh cadavers from L1 to S1 roots. The target point of LNRB was the midpoint between the lower border of the transverse process and the facet joint at each level. The target point of S1 nerve root block was the S1 foramen, which can be visualized between the median sacral crest and the posterior superior iliac spine, below the L5-S1 facet joint. The injection was performed via an in-plane approach under real-time axial view ultrasound guidance. Fluoroscopic validation was performed after the injection of 2 cc of contrast agent. Results: The needle placements were correct in all injections. Fluoroscopy confirmed an intra-foraminal contrast spreading pattern following 41 of the 48 injections (85.4%). The other 7 injections (14.6%) yielded typical neurograms, but also resulted in extra-foraminal patterns that occurred evenly in each nerve root, including S1. Conclusion: Ultrasound-guided injection may be an option for the delivery of injectate into the S1 nerve root, as well as lumbar nerve root area.

Development of WLAN AP based on IBM 405GP (IBM PowerPC 405GP를 이용한 Wireless LAN Access Point 개발에 관한 연구)

  • Kim Do-Gyu
    • The Journal of Information Technology
    • /
    • v.6 no.3
    • /
    • pp.65-73
    • /
    • 2003
  • The evaluation AP embedded Linux board is implemented. The board is made of IBM 405 GP processor, PPCBoot-1.2.1 boot loader, Linux-2.4.21 kernel and root file system. The evaluation board has two flash memories, boot flash and application flash of size 512Kbyte and 16Mbyte, respectively. And it supports IEEE 802.11a which provide the maximum throughput of 54Mbps in the 5.2GHz frequency band. MTD(Memory Technology Device) and JFFS2(Journalling Flash File System version 2) technologies are adopted to optimally package the system software, boot loader, kernel and root file system. And in order to optimize root file system, busybox package and tiny login are used. Linux kernel and root file system is combined together with mkimage utility.

  • PDF