• 제목/요약/키워드: room strain

검색결과 418건 처리시간 0.025초

Mn 첨가량 변화에 따른 Tb/Mn이 첨가된 화학양론조성 LiNbO3 단결정의 광학적 특성 (Optical Properties of Stoichiometric Tb/Mn Co-doped LiNbO3 Single Crystals Dependent on Mn Concentration)

  • 이성문;신동익;김근영;백승욱;윤대호
    • 한국세라믹학회지
    • /
    • 제41권1호
    • /
    • pp.92-95
    • /
    • 2004
  • Micro-Pulling Down (${\mu}$-PD) 법을 이용하여 $MnO_2$$Tb_4O_7$를 첨가하여 crack. 열 strain 등의 결함이 없는 화학양론조성의 $LiNbO_3$ 단결정을 c-축으로 직경 1.0mm, 길이 25-30mm의 크기로 성장시켰다. Electron Probe Micro Analysis (EPMA)를 이용하여 결정 내에 $MnO_2$$Tb_4O_7$이 균일하게 분포되어 있음을 확인하였다. 또한 Fourier Transform-Infrared Spectrophotometer (FT-IR)을 사용하여 OH 흡수밴드를 관찰하였고, 성장된 결정의 $MnO_2$$Tb_4O_7$ 첨가에 따른 형광특성의 변화를 측정하였다.

효소면역법에 의한 닭 전염성 후두기관염 바이러스 항체 측정에 관한 연구 (Detection of Antibody to Infectious Laryngotracheitis Virus by Enzyme Linked Immunosorbent Assay)

  • 임숙경;위성하;최정옥;고홍남
    • 한국동물위생학회지
    • /
    • 제15권1호
    • /
    • pp.32-45
    • /
    • 1992
  • In order to establish and enzyme-linked immunosorbent assay to ILTV, field virus strain of ILTV was propagated in chorioallantoic membrane of the embryonated eggs. purified and used as antigen. The antisera selected from the field samples and immunized chickens based on serum neutralization test were used as the standard positive and negative sera in all tests. It was found that optimal antigen concentration was $2{\mu}g$ of protein per well and a 1 : 100 dilution of standard serum showed low background optical density with negative serum and high P/N values of positive sera. A 1 : 500 dilution of the rabbit anti-chicken IgG peroxidase conjugate produced a high P/N values and thirty minutes was chosen as suitable time to read the optical density of the enzyme substrate reaction and optical density was consistent during the 16 hours after stopper was treated. When coated antigen was kept on microplate for varying time up to 16 hours at $4^{\circ}C$ or $37^{\circ}C,$ no significant difference was observed between the treatment. The coated antigen could be kept without change of antigenicity for at least one month at $-70^{\circ}C,\; -20^{\circ}C,\; 4^{\circ}C$ and room temperature. When blocking buffer contanining bovine serum albumin was mixed directly with conjugate and serum at 10% level induced higher P/N values compared to blocking antigen coated microplate with the same blocking buffer. The coefficience of correlation between ELISA and SN test was 0.577. When antibody response of chickens, vaccinated with ILTV, was examined by ELISA and SN test, antibody rising and decay pattern between the two test was similar until 11 weeks of age. However 12 weeks onward antibody titer checked on by SN test was slightly lower than that tested by ELISA.

  • PDF

설계하중 사전재하 및 잔존강도 시험방법에 따른 고강도콘크리트의 고온특성평가 -제 1보, 강도특성을 중심으로- (Evaluation For Mechanical Properties of High strength Concrete by Stressed Test and Tressed Residual Strength Test)

  • 이태규;김영선;이의배;박찬규;김규용;김무한
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 춘계 학술발표회 제20권1호
    • /
    • pp.869-872
    • /
    • 2008
  • 최근, 고온가열을 받은 콘크리트의 압축강도, 탄성계수 및 최대하중에서의 변형에 대한 체계적인 연구가 실험적으로 접근되고 있다. 본 연구는 40, 60, 80MPa급 고강도콘크리트의 재료역학적 특성에 있어서 $20{\sim}700^{\circ}C$ 범위로 상승되는 온도의 영향을 연구하는데 그 목적이 있다. 본 연구에서 제안한 시험법은 설계하중 사전재하 및 잔존강도 시험방법으로서 극한강도의 25%하중을 사전재하한 후 시험체의 가열을 하중을 유지한 상태에서 목표온도까지 가열하였고 재하는 고온상태 및 상온에서 24시간 냉각상태에서 시험체가 파괴될 때까지 재하를 실시했다. 시험결과 콘크리트 강도가 증가할수록 상온의 수준과 비교하여 고온에서의 상대적인 압축강도와 탄성계수는 감소하는 것으로 나타났으며 실험결과를 바탕으로 온도의 수준에 따른 압축강도와 탄성 계수의 상관 관계식을 도출하였다.

  • PDF

항균성물질이 함유된 세라믹 LDPE필름의 항균효과 및 식품의 저장성 (Antimicrobial Activity and Food Storage of LDPE Ceramic Film Containing Antimicrobial Agents)

  • 김현수;성림식;유대식
    • KSBB Journal
    • /
    • 제15권6호
    • /
    • pp.600-604
    • /
    • 2000
  • 다양한 식품의 미생물에의한 변패를 억제하고 저장성을 높 일수 있는 포장필름을 개발하기위하여, 미생물이 생산하는 천연 항균성 물질을 홉착시킨 합성 세라믹올 첨가하여 세라 믹 LDPE 필륨을 제조하였다. 천연 항균제로는 methanol자화 방선균 MO-16 및 MO-17균이 생산한 항세균제와 새로이 분 리한 방선균 No. 31이 생산한 항진균제를 사용하였다. 방선 균 No. 31이 생산한 항진균성 불질은 배양 4일째 항균효과가 우수하였으며, $121^{\circ}C$에서 15분간 열처리시에도 항균력이 유 지되는 내열성이 확인되었다. 제조한 세라믹 LDPE 필름의 미생불 생육 억제효과를 검토한 결과 조분쇄한 돈육의 경우 포장하여 실온 및 $4^{\circ}C$에서 보존시 시판필름에 비해 미생물 생육 억제효과가 우수하였다. 고제배지에 제조필름을 첨가하 여 E. coli에 대한 항균효과를 검토한 결과 첨가량에 따라 항 균효과가 우수한 것이 입증되었다 제조펼름으로 포장한 6종 류의 식품에 대한 저장성을 검토한 결과 시판필름에 비해 저 장성이 우수한 것이 확인되었으며 특히 양송이에 대한 저장 효과가 우수하였다.

  • PDF

$La_{2/3}Sr_{1/3}MnO_3SiO_2/Si(100)$ 박막의 저-자장 터널형 자기저항변화의 두께 의존성 (Thickness Dependence of Low-Field Tunnel-Type Magnetoresistance in$La_{2/3}Sr_{1/3}MnO_3SiO_2/Si(100)$ Thin Films)

  • 심인보;안성용;김철성
    • 한국자기학회지
    • /
    • 제11권3호
    • /
    • pp.97-103
    • /
    • 2001
  • Water-based 졸겔 증착법을 이용하여 디결정체 La$_{2}$3/Sr$_{1}$3/MnO$_3$(LSMO) 박막을 2000$\AA$ 두께의 열 산화층을 갖는 Si(100) 기판상에 제조하여 상온에서 LSMO박막의 두께변화 따른 저 자장영역(120 Oe)에서의 터널형 자기저항 변화를 연구하였다. XRD 회절분석 결과 단일상의 페롭스카이트 결정구조임을 알 수 있었으며 RBS 스펙트럼 분석결과 박막의 조성비 La:Sr:Mn:O는 0.67:0.33:1.0:3.0임을 알 수 있었다. LSMO 박막의 자성특성 측정결과 두께 증가에 따라 포화자화는 750$\AA$까지 급격한 증가현상을 보이다 150$\AA$을 기점으로 점차 감소하는 경향을 나타내고 있으며, 보자력은 800 $\AA$ 까지 급격한 증가를 보이다 일정해지는 경향을 볼 수 있었다. 저 자장영역에서의 터널형 자기저항 변화비는 약 1500 $\AA$의 두께 영역에서 최대값을 나타냄을 알 수 있었다. 이러한 저 자장 영역에서 LSMO 박막의 터널형 자기저항 변화비의 두께 의존성은 LSMO 박막과 Si 기판의 계면에 존재하는 상호확산 현상에 의한 dead layer의 존재 및 LSMO 박막의 열처리시 발생되는 열 격자 변형 효과로 설명하였다.

  • PDF

흰쥐의 적출한 위(胃)에서 산증(酸症)과 Prostaglandin $E_1$이 위산(胃酸) 분비에 미치는 영향 (Effect of Acidosis and Prostaglandin $E_1$ upon Acid Secretion in Isolated Whole Stomach in Rat)

  • 김철;김정진;박형진
    • The Korean Journal of Physiology
    • /
    • 제14권2호
    • /
    • pp.17-20
    • /
    • 1980
  • This study was undertaken to investigate the effect of the acidosis on the gastric acid secretion in the isolated whole stomach of the rat and the effect of prostaglandin $E_1$ on the gastric acid secretion influenced by the acidosis. Twenty-two male albino rats(Sprague-Dawley strain) were used. The isolated whole stomach from each rat was introduced into the Kreb's solution which was continuously gassed with $95%O_2-5%CO_2$ for 1 hour, after irrigation of the lumen with cold physiological saline$(4^{\circ}C)$. Thereafter, each stomach was irrigated again with 5% dextrose solution (pH 7.4, $37^{\circ}C$), and filled with the dextrose solution. All the stomachs with the dextrose solution were divided into 4 groups according to the Kreb's solutions in which each stomach was incubated for 30 min: 1) control group, in the pH 7.4 solution, 2) $PGE_1$ group, in the pH 7.4 solution containing $5\;{\mu}g/ml$ of $PGE_1$, 3) acid group, in the pH 7.0 solution, and 4) $acid+PGE_1$ group, in the pH 7.0 solution containing $5\;{\mu}g/ml$ of $PGE_1$. After incubatory period, the contents of each stomach were collected and centrifuged(1,500 rpm, room temperature) for 15 min. The acid output in the supernatant was determined with 0.012 N NaOH by means of autotitrator(Dosimat, Metrohm Herisau Co.) at pH 7.4. Results obtained were as follows: 1) The acid output of the acid group increased significantly in comparison with the control value. 2) The acid output of the $acid+PGE_1$ group decreased significantly in comparison with the acid group. It is inferred from the above results that the acidosis facilitates the gastric acid secretion and $PGE_1$ inhibits the gastric acid secretion induced by the acidosis.

  • PDF

Establishment of CTE Measurement Procedure for PPLP at 77 K for HTS Power Cables using Double Extensometers

  • Dedicatoria, Marlon J.;Dizon, John Ryan C.;Shin, Hyung-Seop;Sim, Ki-Duk
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제14권4호
    • /
    • pp.24-27
    • /
    • 2012
  • The measurement of the coefficient of thermal expansion (CTE) of polypropylene laminated paper (PPLP) as electric insulating material is important for its practical superconducting device application. The thermal strain induced to HTS tapes and its insulating material during cooling from room temperature might largely affect the critical current ($I_c$) of HTS tapes. In this study, the thermal contraction of PPLP material was measured during cooling from 300 K to 77 K using double extensometers. Initially, the CTE of a brass tape was measured and it was compared with a reference data. It was found that the measured thermal expansion data of the brass material approaches that of the reference one. Based on the results, it was then confirmed that the measurement technique could be applied to thin and flexible samples. Therefore, the same measurement procedure was applied to PPLP material using double extensometers. As a result, the linear CTE of the PPLP at 77 K has been measured to be ${\sim}15.3{\times}10^{-6}/K$. Also, it was found that the thermal contraction characteristics of PPLP was dominated by polypropylene on the cross direction (higher thermal contraction) while it was dominated by Kraft paper on the machine direction (lower thermal contraction). Overall, this measurement procedure could be adopted for the determination of CTE of flexible materials such as PPLP.

$Al_{18}B_4O_{33}$휘스커 강화 금속기 복합재료의 파괴인성에 관한 연구 (A Study on Fracture Toughness of Metal Matrix Composites Reinforced with $Al_{18}B_4O_{33}$)

  • 박성호;최용범;박원조;허선철;윤한기
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2002년도 추계학술대회 논문집
    • /
    • pp.335-340
    • /
    • 2002
  • In recent years, the study of metal matrix composite has increased specially, aluminum alloy, research and development are briskly progress to find new metal matrix composite. this study is following the this purpose; This study is used metal matrix composite that was produced by matrix, AC4CH. and reinforcement $A_{18}B_4O_{33}$ metal matrix composite to add $Al_2O_3,\;TiO_2$ for strengthen of binding together among the Whisker. Each Metal matrix composite is produced using the squeeze casting method. Fracture tounghness test was in accordance with the provisions of ASTM E399; Specimen was produced half-size CT specimen W=25mm, B=12.5mm, Cross head speed 0.05mm/min in room temperature. The plane strain fracture toughness $K_{IC}$ is $8.7MPa-m^{0.5}$ for $Al_{18}B_4O_{33}$/AC4CH., $9.28MPa-m^{0.5}$ for $Al_{18}B_4O_{33}$/AC4CH added $TiO_2$. and $Al_2O_3$ but AC4CH alloy was violated the critical stipulated by ASTM standard for a valid measurement of $K_{IC}$. In case of, it was performed $I_{IC}$ test instead of $K_{IC}$ based on ASTM E 1820

  • PDF

ABOw/AC4CH의 바인더 종류에 따른 파괴인성 및 미끄럼마모 특성 (Fracture Toughness and Slinding Wear Properties of ABOw/AC4CH by Binder Additives)

  • 박원조;정재욱;최용범;이광영
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2002년도 추계학술대회 논문집
    • /
    • pp.373-378
    • /
    • 2002
  • Metal matrix composites have a great interest in recent years because high specific strength, high specific stiffness characteristics, and application ranges of the composites are extend to variety industry. In this paper, an investigation was performed on the plane strain fracture toughness and slinding wear properties of AC4CH alloy(Al-Si-Mg line) reinforced with 20wt% aluminum borate whisker expect one, which contained a inorganic binder($TiO_2$). the binder led to the formation of strengthen the whisker each other. The test of fracture toughness was using CT(half size) specimen of thickness 12.5mm, width 25mm. and test of slinding wear of using tribo a pin-on-disk machine and lubricant is used without paraffine 8.2CST at room temperature. As results, Fracture toughness $K_{IC}$ is $8.7MPa-m^{05}$ for ABOw/AC4CH, $9.28MPa-m^{05}$ for ABOw/AC4CH added $TiO_2$. but AC4CH alloy was violated the critical stipulated by ASTM standard for valid measurement of $K_{IC}$. In case of, it was performed $J_{IC}$ test instead of $K_{IC}$ based on ASTM E 1820.

  • PDF

주기적인 반복 열하중이 패키징된 FBG 센서 신호 특성에 미치는 영향 (Effects of Cyclic Thermal Load on the Signal Characteristics of FBG Sensors Packaged with Epoxy Adhesives)

  • 김헌영;강동훈
    • 대한기계학회논문집A
    • /
    • 제41권4호
    • /
    • pp.313-319
    • /
    • 2017
  • 광섬유 센서는 전자기 간섭에 독립적이고 원거리 계측이 가능하여 다양한 분야에 적용되고 있다. 특히, 광섬유 브래그 격자(FBG) 센서는 다중화, 절대측정이 가능하여 구조 건전성 모니터링(SHM)을 위해 널리 사용되고 있다. 일반적으로, FBG 센서는 에폭시와 같은 접착제를 이용하여 구조물에 직접 부착 및 모듈 제작을 통해 적용한다. 하지만, 에폭시로 부착된 FBG 센서 기반의 장시간 모니터링 과정에서 신호 변화가 발생하여 보정이 요구된다. 이는 계절적 요인으로써 장시간 온도 변화 환경에 노출되어 센서의 접착구조 변형에 의한 결과이며, 센서 접착제의 열경화 과정에 대한 규명이 필요하다. 본 연구에서는, 패키징 방식 4가지 경우의 FBG 센서 시편을 제작하고, 반복 열하중 시험을 수행하였다. 시험 결과, 상온경화 과정에서 미소한 잔류 압축 변형률이 발생하였고, 반복 열하중 초기단계에서 수백 ${\mu}{\varepsilon}$의 압축 변형률이 인가되어 유지되었다. 이를 통해 FBG를 이용한 장시간 SHM을 위해서는 FBG 센서의 신호에 대한 안정화 과정이 필요함을 확인하였다.