• Title/Summary/Keyword: rooftops green

Search Result 14, Processing Time 0.017 seconds

A Study on the Application of Small Wind Power System in Apartment Housing (공동주택에서의 소형풍력발전시스템 적용에 관한 연구)

  • Park, Jin-Chul;Kyung, Nam-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.23 no.2
    • /
    • pp.21-34
    • /
    • 2003
  • This study aims to present the applicability of wind turbine generator system to urban buildings for the utilization of clean renewable energy. The results are as follows; According to the wind resource analysis, it has been found that small sized wind power system can be viable for buildings application due to the amplification of wind velocity around buildings or building clusters, in spite of low mean velocity of 2-3m/s in Seoul and Kyunggi urban areas. But planners must perform micrositing analysis around building so that wind turbine can be located at high velocity zones. The system must be designed to avoid obstacles preventing prevailing wind in buildings. It should be recognized that wind speeds are changing depending on the height and length from buildings. The wind power system can be used as a symbol of landmark which shows a sustainable architecture from the scenary Itself A case study for apartment building in urban showed that wind power systems can be applicable in two kinds of place, rooftops and ground levels. Especially, the wind power systems must be carefully positioned so that wind resources do not decrease when it is installed at ground levels. and according to life cycle cost analysis, adaption of new small win4 power systems to buildings were proved to produce a profit if it is considered the expense of environment improvement and the wind speed increasing according to rise of building height. This research will ultimately achieve green architecture that preserves nature and at the same time provides pleasant environment to humans, and will play a great role in establishing the environment-preserving sustainable architecture of the 21th century.

Long-term Relative Humidity Changes on High Temperature Days of Major Cities in Korea for the Recent 37 Years (최근 37년간 우리나라 주요도시의 고온일을 대상으로 한 상대습도의 경년변화)

  • Park, Myung-Hee;Lee, Joon-Soo;Suh, Young-Sang;Han, In-Seng;Hae, Hyun-Gun;Kim, Hae-Dong
    • Journal of Environmental Science International
    • /
    • v.22 no.12
    • /
    • pp.1671-1681
    • /
    • 2013
  • The study selected 10 regions among major Korean cities. Then the study classified the yearly change of relative humidity of those regions for 37 years based on 1996 (from 1974 to 2011) aimed at high temperature days, and examined them by stage regarding daily maximum temperature. For large cities and small cities, in general relative humidity had been likely to increase at high temperatures of $30^{\circ}C$ or over before 1996, whereas it has decreased since 1996. For suburban areas, relative humidity had been prone to diminish before 1996, whereas it has been likely to either increase since 1996 or rarely some of the cities have not shown any change. The increasing tendency of relative humidity before 1996 in large cities and small cities is believed to be because of an increase of the latent heat of vaporization by the supply of steam from cooling towers established in downtown areas. Meanwhile, the decreasing tendency from 1996 is concluded to be caused by the change from counter-current circular cooling towers, which produce a great quantity of steam including arsenic acid, to cross-flow cooling towers, which produce hardly any steam containing arsenic acid. This change was in accordance with the modification and pursuit of an urban planning law that ordered cooling towers that had been installed on rooftops be installed in the basement of buildings in consideration of a "Green network creation" project by the Ministry of Environment, urban beautification, concerns since 1996 over building collapses, and according to an argument that steam containing arsenic acid could be harmful to human health owing to chemicals contained in the water in the cooling tower in summer.

Application of Hemeroby for Environmental Assessment with Environmental Planning - Focused on the Case“LG Village”- (Hemeroby를 이용한 자연환경평가 및 환경계획 - LG 빌리지의 사례를 중심으로 -)

  • 김혜주;조수경
    • Korean Journal of Environment and Ecology
    • /
    • v.12 no.3
    • /
    • pp.253-258
    • /
    • 1998
  • It is common in foreign countries to make a compensative plan for environmental destruction which is caused by development action even in where development is permitted. But, in Korea, environmental plan was regarded as just meeting the legal standard of green area in site development. This study focused on the case of university project, LG village plan, is to evaluate the environment of the site using Hemeroby and suggested restoration plan in compensation for the destructive. The site was a huge development area of apartment located in Suwon. First of all, we evaluated the site using Hemeroby and compared this with LG village plan. Then, we made a compensative plan for the environmental destruction which was not compensated in LG village plan. The results were as follows; $\beta$-/$\alpha$-euhemeroby of the Site was 80.1% before the development and, after the development, $\beta$-/$\alpha$-euhemeroby of the site dropped to 43.7% and meta-hemeroby increased from 56.3% to 17%. Therefore, we could accept the buildings of LG village development plan and suggested a compensative plan with which we could raise $\beta$-/$\alpha$-euhemeroby like restoring the river, greening parking-lots and rooftops, revegetating cut slope.

  • PDF

The Characteristics of Retention and Evapotranspiration in the Extensive Greening Module of Sloped and Flat Rooftops (저토심 경사지붕과 평지붕 녹화모듈의 저류 및 증발산 특성)

  • Ryu, Nam-Hyong;Lee, Chun-Seok
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.41 no.6
    • /
    • pp.107-116
    • /
    • 2013
  • This study was undertaken to investigate the characteristics of retention and evapotranspiration in the extensive greening module of sloped and flat rooftops for stormwater management and urban heat island mitigation. A series of 100mm depth's weighing lysimeters planted with Sedum kamtschaticum. were constructed on a 50% slope facing four orientations(north, east, south and west) and a flat rooftop. Thereafter the retention and evapotranspiration from the greening module and the surface temperature of nongreening and greening rooftop were recorded beginning in September 2012 for a period of 1 year. The characteristics of retention and evapotranspiration in the greening module were as follows. The water storage of the sloped and flat greening modules increased to 8.7~28.4mm and 10.6~31.8mm after rainfall except in the winter season, in which it decreased to 3.3mm and 3.9mm in the longer dry period. The maximum stormwater retention of the sloped and flat greening modules was 22.2mm and 23.1mm except in the winter season. Fitted stormwater retention function was [Stormwater Retention Ratio(%)=-18.42 ln(Precipitation)+107.9, $R^2$=0.80] for sloped greening modules, and that was [Stormwater Retention Ratio(%)=-22.64 ln(X)+130.8, $R^2$=0.81] for flat greening modules. The daily evapotranspiration(mm/day) from the greening modules after rainfall decreased rapidly with a power function type in summer, and with a log function type in spring and autumn. The daily evapotranspiration(mm/day) from the greening modules after rainfall was greater in summer > spring > autumn > winter by season. This may be due to the differences in water storage, solar radiation and air temperature. The daily evapotranspiration from the greening modules decreased rapidly from 2~7mm/day to less than 1mm/day for 3~5 days after rainfall, and that decreased slowly after 3~5 days. This indicates that Sedum kamtschaticum used water rapidly when it was available and conserved water when it was not. The albedo of the concrete rooftop and greening rooftop was 0.151 and 0.137 in summer, and 0.165 and 0.165 in winter respectively. The albedo of the concrete rooftop and greening rooftop was similar. The effect of the daily mean and highest surface temperature decrease by greening during the summer season showed $1.6{\sim}13.8^{\circ}C$(mean $9.7^{\circ}C$) and $6.2{\sim}17.6^{\circ}C$(mean $11.2^{\circ}C$). The difference of the daily mean and highest surface temperature between the greening rooftop and concrete rooftop during the winter season were small, measuring $-2.4{\sim}1.3^{\circ}C$(mean $-0.4^{\circ}C$) and $-4.2{\sim}2.6^{\circ}C$(mean $0.0^{\circ}C$). The difference in the highest daily surface temperature between the greening rooftop and concrete rooftop during the summer season increased with an evapotranspiration rate increase by a linear function type. The fitted function of the highest daily surface temperature decrease was [Temperature Decrease($^{\circ}C$)=$1.4361{\times}$(Evapotranspiration rate(mm/day))+8.83, $R^2$=0.59]. The decrease of the surface temperature by greening in the longer dry period was due to sun protection by the sedum canopy. The results of this study indicate that the extensive rooftop greening will assist in managing stormwater runoff and urban heat island through retention and evapotranspiration. Sedum kamtschaticum would be the ideal plant for a non-irrigated extensive green roof. The shading effects of Sedum kamtschaticum would be important as well as the evapotranspiration effects of that for the long-term mitigation effects of an urban heat island.