• 제목/요약/키워드: roof systems

검색결과 214건 처리시간 0.025초

Effects of Experimental Drought on Soil Bacterial Community in a Larix Kaempferi Stand

  • Kim, Beomjeong;Choi, Byoungkoo
    • Journal of Forest and Environmental Science
    • /
    • 제34권3호
    • /
    • pp.258-261
    • /
    • 2018
  • Drought alters soil microorganisms; however, it is still not clear how soil microbes respond to severe drought conditions. In this study, the responses of soil bacterial community to experimental drought in a coniferous stand were examined. Six $6m{\times}6m$ plots with three replicates of control and drought treatments were delimited. PCR amplification and Illumina sequencing were conducted for cluster analysis of soil bacterial community and species richness and species diversity was analyzed. Along the 393 days of simulated drought from July 2016 to October 2017, soil bacterial species diversity slightly increased whereas species richness decreased in both control and roof plots. Moreover, soil bacterial species richness more decreased in roof plots than in controls. Combining these results, soil bacterial activity might have been altered by simulated drought.

지진하중을 받는 대공간 구조물의 동적 거동 특성에 관한 연구 (A Study on the Characteristics of dynamic Behaviors for the Spatial Structures under Seismic Load)

  • 김민식;이상주;이동우;한상을
    • 한국공간구조학회:학술대회논문집
    • /
    • 한국공간구조학회 2005년도 춘계학술발표회 및 정기총회 2권1호(통권2호)
    • /
    • pp.227-235
    • /
    • 2005
  • The earthquake-resistant structural systems have to ensure the sufficient stiffness and ductility for the stability. For those purposes, recently, the performance design concept to increase the degree of absorbed energy level of structures has been proposed. One practical way of the performance design in the spatial structures is to apply the isolation system to boundary parts of roof system and sub-structure to obtain the target performance. So, it is necessary to examine the characteristics of dynamic behavior of spatial structures governed by higher modes rather than lower modes different from the cases of high rise buildings. The objectives of this paper are to develop the equivalent model to simplify the analytical processes and to investigate the dynamic behavior of roof system according to the mass and the stiffness of sub-structures as a fundamental study of performance design for the spatial structures.

  • PDF

Study on Coupled Resonance Frequencies and Acoustic Responses in a 3-D Acoustic Cavity with the Air-gap for Safer Driving Condition

  • Kang, Sang-Wook
    • International Journal of Safety
    • /
    • 제5권1호
    • /
    • pp.17-23
    • /
    • 2006
  • An investigation was carried out to determine the effect of the thickness of the air-gap installed between the roof metal sheet and the headliner on booming noise in passenger cars. In addition, a way of offering quieter driving condition to drivers and passengers was studied. It was found that a very thin air-gap corresponding to approximately 3/100 of the height of the passenger compartment causes noticeable change in the coupled resonance frequencies and acoustic responses. Furthermore, a guideline is proposed for determining an optimal air-gap thickness during design stage of the air-gap beneath the roof metal sheet for reducing booming noise.

PV모듈의 지붕 적용 유형 분류 및 특성 분석 (An analysis of Classification and Characteristics of PV Modules Applied into Building Roof)

  • 문종혁;김진희;김용재;김준태
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.251-258
    • /
    • 2009
  • Building-Integrated Photovoltaics (BIPV) is a photovoltaic (PV) technology which can be incorporated into the roofs walls of both commercial and domestic buildings to provide a source of electricity. BIPV systems can operate as a multi-functional building components, which generates electricity and serves as part of building envelope. It can be regarded as a new architectural elements, adding to the building's aesthetics. Applying PV modules on roof has an advantage over wall applications as they seem to receive more solar radiation on PV modules. There are various types of PV applications on building roofs: attached, on-top and integrated. This paper describes the classification and characteristics of PV applications on roofs.

  • PDF

CFD 검증을 위한 풍동 및 PIV를 이용한 자연환기식 온실 내부 공기유동 분석 (Analysis on Internal Airflow of a Naturally Ventilated Greenhouse using Wind Tunnel and PIV for CFD Validation)

  • 하정수;이인복;권경석;하태환
    • 생물환경조절학회지
    • /
    • 제23권4호
    • /
    • pp.391-400
    • /
    • 2014
  • The number of large scale greenhouses has recently been increasing to cope with mass consumption of agricultural product. Korean government announced a new development plan for constructing greenhouse complex in reclaimed lands for the purpose of improvement in exports and activation of domestic market of agricultural product. Wind environment in the reclaimed land is totally different from that of inland area, and it can give a strong influence on ventilation performance of naturally ventilated greenhouse facilities. In this study, internal airflow analysis of naturally ventilated greenhouse built on a reclaimed land was conducted using wind tunnel and PIV for validation research. Later, the PIV measured results will be used to improve the accuracy of 3 dimensional CFD simulation in the future. Wind profile at a reclaimed land was produced using ESDU program and it was applied to the wind tunnel. The calculated error was only 5% and 0.96 of correlation coefficient, implying that the computed profiles were designed properly. From the measured results, when external wind speed changed from $1m{\cdot}s^{-1}$ to $1.5m{\cdot}s^{-1}$, air velocities inside the greenhouse which PIV measured were also increased proportionately in case of both side vent open and side-roof vent open. Considering reduced ratio of air velocity inside the greenhouse, it was measured a minimum of 40% in case of side vent and 30% in case of side-roof vent compared with external wind speed from each vent type. From the quantitative and qualitative PIV analysis, the PIV measured results indicated that there were well ventilated and stagnant areas in the greenhouse according to external wind condition as well as ventilation design.

풍동을 이용한 간척지 내 양지붕형 온실의 지붕 경사에 따른 풍압계수 평가 (Estimation of Wind Pressure Coefficients on Even-Span Greenhouse Built in Reclaimed Land according to Roof Slop using Wind Tunnel)

  • 김락우;김동우;류기철;권경석;이인복
    • 생물환경조절학회지
    • /
    • 제23권4호
    • /
    • pp.269-280
    • /
    • 2014
  • To cope with increasing of vegetables and flowers consumptions, horticulture facilities have been modernized. Korea government recently announced construction plan of new greenhouse complex at reclaimed land. However wind characteristics of reclaimed land is totally different from those of inland, wind pressure on greenhouse built in reclaimed land should be carefully evaluated to secure structural safety on the greenhouse. In this study, as a first step, wind pressure coefficient and local wind pressure coefficient on even-span greenhouse were measured using wind tunnel test. ESDU was adopted to realize wind characteristics of reclaimed land such as wind and turbulence profiles. From the wind tunnel test, when wind direction was 0 degree, it was concluded that KBC2009 standard underestimated scale of wind pressure coefficients at roof area of greenhouse whereas NEN-EN2002 standard underestimated those at every surface of greenhouse. When wind direction was 90 degree, both standards did not well reflect the characteristics of wind pressure distribution. From the analysis of local wind pressure coefficients according to wind direction conditions, design of covering, glazing bar of greenhouse where large effects of the local wind pressure were estimated should be well established. Wind pressure coefficients and local wind pressure coefficients according to parts of the greenhouse were finally suggested and these results could be practically used for suggesting new design standards of greenhouse.

Building Integrated Vegetation Systems into the New Sainsbury's Building Based on BIM

  • Lee, Dong-Kyu
    • 한국BIM학회 논문집
    • /
    • 제4권2호
    • /
    • pp.25-32
    • /
    • 2014
  • Today, there is a growing need of environment-friendly buildings, so-called 'green', facilities, and energy saving buildings to decrease environmental pollutants released into cities by construction activities. Green-Building Information Modeling (Green-BIM) is a purpose-built solution which supports to forecast energy consumption of 3-D model of a building by augmenting its primary 3-D measurements (width, height and depth) with many more dimensions (e.g. time, costs, social impacts and environmental consequences) throughout a series of sequential phases in the lifecycle of a building. The current study was carried out in order to integrate vegetation systems (particularly green roof and green wall systems) and investigate thermal performance of the new Sainsbury's building which will be built on Melton road, Leicester, United Kingdom. Within this scope, a 3-D building model of the news Sainsbury's building was first developed in $Autodesk^{(R)}$ $Revit^{(R)}$ and this model was then simulated in $Autodesk^{(R)}$ $Ecotect^{(R)}$once weather data of the construction site was obtained from $Autodesk^{(R)}$ Green Building $Studio^{(R)}$. This study primarily analyzed data from (1) solar radiation, (2) heat gains and losses, and (3) heating and cooling loads simulation to evaluate thermal performance of the building integrated with vegetation system or conventionally available envelops. The results showed that building integrated vegetation system can potentially reduce internal solar gains on the building rooftops by creating a 'bioshade'. Heat gains and losses through roofs and walls were markedly diminished by offering greater insulation on the building. Annual energy loads for heating and cooling were significantly reduced by vegetation more significantly through the green roof system in comparison to green wall system.

지상형 탄약고의 내부온도 감소 방안 연구 (A Study on the Deduction of Internal Temperature of the Ground Magazine)

  • 박형주;최명진;양재경
    • 산업경영시스템학회지
    • /
    • 제36권3호
    • /
    • pp.142-149
    • /
    • 2013
  • Among ammunitions which are stored in a war field, the lifespan of propelling gunpowder is affected by storage environment such as storage temperature, humidity, and exposure to sunlight. These are because Nitrocellulose (NC) which is the main component of propelling gunpowder can be naturally disassembled to unstable substances similar with other nitric acid ester. We can't prevent it fundamentally from being disassembled, but to restrain induction of automatic disassembly by decomposition product, a decomposition product ($NO_2$, $NO_3$, and $HNO_3$) and tranquillizer DPA (Diphenylamine), having high reactivity, are added into a propellant. For this, it will decrease the velocity of tranquillizer which can also affect the velocity of producing the decomposition product of NC, storage temperature or humidity of propelling gunpowder is higher, drop of tranquillizer content is much faster. Therefore, to extend storage lifespan of propelling gunpowder, it is really important to control storage temperature or humidity inside the magazine. Hereupon, according to the manufacture of small scale model magazine and the result of performing experiments and measuring variation of inside temperature (storage temperature), using roof types that have a steel slate structure of magazine among ground magazines, this research shows the differences in details.

교육시설의 신재생에너지 시스템 적용성 평가 방법론에 관한 연구 (Study on the feasibility test of Renewable Energy Systems for Schools)

  • 박은미;장지현;남현진;배민호;박효순;김재민
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 춘계학술대회 논문집
    • /
    • pp.99-102
    • /
    • 2008
  • In terms of operation profiles and building characteristics, Schools, as public facilities, are one of the most suitable buildings for small scale Renewable energy systems since they have its energy demand on daytime mostly and large open area, roof surface available for the installation of Renewable energy systems such as solar collectors or Photovoltaic pannels. This paper presents a methodology of the feasibility test for Renewable energy systems to be intalled at schools. The methodology is based on the analysis of the demand/supply profiles dynamic matching. a case study is also presented to test the applicability of the proposed assessment methodology.

  • PDF

국내에 도입된 Sedum album L.의 생육 특성 및 저토심 옥상 녹화 시스템에 관한 연구 (Studies on Growth Characteristics and Shallow Green-Roof Systems of Sedum album L. Introduced in Korea)

  • 김인혜;허무룡;허근영
    • 한국조경학회지
    • /
    • 제33권5호통권112호
    • /
    • pp.69-82
    • /
    • 2005
  • These studies were carried out (1) to investigate the growth characteristics of Sedum album L. in the field, (2) to propose a suitable shallow peen roof system for this plant, and (3) to evaluate plant growth in the proposed system over the long term. The growth characteristics, such as morphological properties, growth habit, shade tolerance, and flowering, were surveyed. In experimental shallow green-roof systems, the effects of drainage type, substrate type, and soil depth on plant growth were investigated. Then drought tolerance was investigated. After planting Sedum album L. in the proposed system survival rate, cover, and resistance to insects, heal and cold were evaluated for about 2 years. The results of these studies are summarized below. 1. In the field, the aboveground part of Sedum album L. did not die back during the winter. Plant height was 4$\sim$7 cm. Roots were distributed to a depth of 5$\sim$7 cm. Sedum album L. is a compact ground-cover plant that spreads vigorously. Shading condition of less than $30\%$ of full sunlight didn't cause any trouble, but shading conditions above $87\%$ made the shape of the shoots and leaves abnormal. The plant bloomed from June to August and had a rather large compound umbel of white, star-shaped flowers. 2. Two systems, a drainage-blend-10 cm soil depth and a reservoir$\cdot$drainage-blend-15 cm soil depth, performed best in terms of cover, fresh weight, and dry weight. The first has an advantage for green roofs because it is lighter than the latter. 3. In drainage-blend-10 m soil depth and modified reservoir · drainage-blend-10 cm soil depth system no plants died for about 4 months after stopping the irrigation. The visual quality of the latter system was above 5 for 4 months and that of the former was under 5 after 2 months. In the field, however, the drought tolerance of Sedum album L. grown in the former would be enough to withstand the dry season. Considering the urban ecosystem and the importance of healthy growth the modified reservoir $\cdot$ drainage-blend-10 cm soil depth system was finally recommended. This system was composed of a 4 cm thick drainage layer and drain outlets placed at a height of 2.5 cm. 4. In the proposed system, the survival rate was $100\%$, and there was no injury induced by insects and heat. The leaf density decreased a little in winter. Cover increased throughout the year. Sedum album L. was planted with a cover of 72$cm^{2}$ on 3 April 2003; on 16 June 2003 and 15 June 2004, cover was $132.66\pm$5.87 $cm^{2}$(1.8 times) and $886.98\pm$63.51 $cm^{2}$(12.3 times), respectively.