• Title/Summary/Keyword: risk of radiation exposure

Search Result 217, Processing Time 0.022 seconds

Evaluation of Radiation Exposure to Nurse on Nuclear Medicine Examination by Use Radioisotope (방사성 동위원소를 이용한 핵의학과 검사에서 병동 간호사의 방사선 피폭선량 평가)

  • Jeong, Jae Hoon;Lee, Chung Wun;You, Yeon Wook;Seo, Yeong Deok;Choi, Ho Yong;Kim, Yun Cheol;Kim, Yong Geun;Won, Woo Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.1
    • /
    • pp.44-49
    • /
    • 2017
  • Purpose Radiation exposure management has been strictly regulated for the radiation workers, but there are only a few studies on potential risk of radiation exposure to non-radiation workers, especially nurses in a general ward. The present study aimed to estimate the exact total exposure of the nurse in a general ward by close contact with the patient undergoing nuclear medicine examinations. Materials and Methods Radiation exposure rate was determined by using thermoluminescent dosimeter (TLD) and optical simulated luminescence (OSL) in 14 nurses in a general ward from October 2015 to June 2016. External radiation rate was measured immediately after injection and examination at skin surface, and 50 cm and 1 m distance from 50 patients (PET/CT 20 pts; Bone scan 20 pts; Myocardial SPECT 10 pts). After measurement, effective half-life, and total radiation exposure expected in nurses were calculated. Then, expected total exposure was compared with total exposures actually measured in nurses by TLD and OSL. Results Mean and maximum amount of radiation exposure of 14 nurses in a general ward were 0.01 and 0.02 mSv, respectively in each measuring period. External radiation rate after injection at skin surface, 0.5 m and 1 m distance from patients was as following; $376.0{\pm}25.2$, $88.1{\pm}8.2$ and $29.0{\pm}5.8{\mu}Sv/hr$, respectively in PET/CT; $206.7{\pm}56.6$, $23.1{\pm}4.4$ and $10.1{\pm}1.4{\mu}Sv/hr$, respectively in bone scan; $22.5{\pm}2.6$, $2.4{\pm}0.7$ and $0.9{\pm}0.2{\mu}Sv/hr$, respectively in myocardial SPECT. After examination, external radiation rate at skin surface, 0.5 m and 1 m distance from patients was decreased as following; $165.3{\pm}22.1$, $38.7{\pm}5.9$ and $12.4{\pm}2.5{\mu}Sv/hr$, respectively in PET/CT; $32.1{\pm}8.7$, $6.2{\pm}1.1$, $2.8{\pm}0.6$, respectively in bone scan; $14.0{\pm}1.2$, $2.1{\pm}0.3$, $0.8{\pm}0.2{\mu}Sv/hr$, respectively in myocardial SPECT. Based upon the results, an effective half-life was calculated, and at 30 minutes after examination the time to reach normal dose limit in 'Nuclear Safety Act' was calculated conservatively without considering a half-life. In oder of distance (at skin surface, 0.5 m and 1 m distance from patients), it was 7.9, 34.1 and 106.8 hr, respectively in PET/CT; 40.4, 199.5 and 451.1 hr, respectively in bone scan, 62.5, 519.3 and 1313.6 hr, respectively in myocardial SPECT. Conclusion Radiation exposure rate may differ slightly depending on the work process and the environment in a general ward. Exposure rate was measured at step in the general examination procedure and it made our results more reliable. Our results clearly showed that total amount of radiation exposure caused by residual radioactive isotope in the patient body was neglectable, even comparing with the natural radiation exposure. In conclusion, nurses in a general ward were much less exposed than the normal dose limit, and the effects of exposure by contacting patients undergoing nuclear medicine examination was ignorable.

  • PDF

Study of Radiation Safety Management of Veterinary Hospital in Korea (동물병원 방사선 안전관리체계에 대한 연구)

  • Chae, Soo-young;Choi, Ho-jung;Lee, Young-won
    • Journal of Veterinary Clinics
    • /
    • v.37 no.1
    • /
    • pp.15-22
    • /
    • 2020
  • This study investigated the effectiveness of radiation safety rules in animal hospital and the awareness and behavior of veterinary radiation workers. With the questionnaires, the data was collected from randomly selected veterinarians in animal hospitals and animal medical imaging centers. Collected data were about radiation device, shielding device, regulations, safety management, education, knowledge, behavior and awareness. Frequency, correlation and multiple regression analysis were performed. The medical devices related with radiation in animal hospital were X-ray (59%), CT (15%), fluoroscopy (12%), mobile X-ray (12%) and others (2%). The number of people using radiation shielding device is high. The answers were low on knowing radiation related regulation and receiving radiation protection education. The group with higher knowledge and awareness shows positive correlation with safety behavior. The increase of use of the radiation related medical devices in veterinary hospital causes the increase of radiation exposure risk. This study suggests that radiation safety management system and policies need to be developed to protect radiation workers and give them correct information and consciousness.

A Study on the Radiation Dose Managements in the Nuclear Medicine Department (핵의학과에서 방사선 피폭관리 실태에 대한 조사 연구)

  • Lim, Chang-Seon;Kim, Se-Heon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.7
    • /
    • pp.1760-1765
    • /
    • 2009
  • After administration of a radiopharmaceutical, the patient remains radioactive for hours or even days, representing a source of potential radiation exposure. Thus, including the personnel who are occupationally exposed to ionizing radiation, radiation exposure must be managed for members of the public, in particular for people accompanying patients. In this study we investigated radiation exposure dose management in the nuclear medicine departments at seven general hospitals. Two of them had no radiation safety considerations for patient transporters, sanitation workers and the like. And they all were careless of radioprotection for people accompanying patients. The average dose rate to people accompanying patients from radioactive patients just before a bone scan was 25.60 ${\mu}$Sv h-1. This is higher than 20 ${\mu}$Sv $h^{-1}$which is the annual public dose limit for temporary use. Therefore radiation dose measurement and risk assessment of patient transporters, sanitation workers and the like should be performed. And the nuclear medicine technologist should provide advices on the radiation safety to patient transporters, sanitation workers, people accompanying patients and so on. To ensure the radiation safety for people accompanying patients, it is required to restrict the patient's access to his relatives, friends and other patients or isolate patients.

Radiological Risk Assessment for the Public Under the Loss of Medium and Large Sources Using Bayesian Methodology (베이지안 기법에 의거한 중대형 방사선원의 분실 시 일반인에 대한 방사선 위험도의 평가)

  • Kim, Joo-Yeon;Jang, Han-Ki;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.30 no.2
    • /
    • pp.91-97
    • /
    • 2005
  • Bayesian methodology is appropriated for use in PRA because subjective knowledges as well as objective data are applied to assessment. In this study, radiological risk based on Bayesian methodology is assessed for the loss of source in field radiography. The exposure scenario for the lost source presented in U.S. NRC is reconstructed by considering the domestic situation and Bayes theorem is applied to updating of failure probabilities of safety functions. In case of updating of failure probabilities, it shows that 5 % Bayes credible intervals using Jeffreys prior distribution are lower than ones using vague prior distribution. It is noted that Jeffreys prior distribution is appropriated in risk assessment for systems having very low failure probabilities. And, it shows that the mean of the expected annual dose for the public based on Bayesian methodology is higher than the dose based on classical methodology because the means of the updated probabilities are higher than classical probabilities. The database for radiological risk assessment are sparse in domestic. It summarizes that Bayesian methodology can be applied as an useful alternative lot risk assessment and the study on risk assessment will be contributed to risk-informed regulation in the field of radiation safety.

Evaluation of Tungsten Blended Filament Shields Made by 3D Printer in Radiography (일반촬영분야에서의 3D 프린터로 제작한 텅스텐 혼합 필라멘트 차폐체의 성능평가)

  • Yoon, Joon;Yoon, Myenog-Seong
    • Journal of radiological science and technology
    • /
    • v.44 no.6
    • /
    • pp.615-621
    • /
    • 2021
  • In the medical field, radiation provides information for the diagnosis and treatment of diseases. As the use of radiation increases and the risk of exposure increases, interest in radiation protection is also rapidly increasing. Lead shielding material is mainly used, which has a risk of lead poisoning and absorption into the body. Tungsten mixed filament shielding sheets were fabricated with a size of 70 × 70 mm and a thickness of 1, 2, and 4 mm by using a 3D printer. In the general shooting experiment, the thickness of the shielding sheet is 1 ~ 5mm, the tube voltage is 60, 80, 100, 120 kVp and the tube current is 20, 40 mAs. In general photography, Tungsten showed better shielding rate compared to Brass, Copper, and Lead protective tools under all irradiation conditions, and in particular, Tungsten 5 mm showed 100% shielding rate. The 3D-printed tungsten mixed filament shielding is expected to be used as a new shield that can replace the existing lead protection tools as it shows a better shielding rate than the existing lead protection tools in Radiography.

Radionuclide-Specific Exposure Pathway Analysis of Kori Unit 1 Containment Building Surface

  • Byon, Jihyang;Park, Sangjune;Ahn, Seokyoung
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.18 no.3
    • /
    • pp.347-354
    • /
    • 2020
  • Site characterization for decommissioning Kori Unit 1 is ongoing in South Korea after 40 years of successful operation. Kori Unit 1's containment building is assumed to be mostly radioactively contaminated, and therefore radiation exposure management and detailed contamination investigation are required for decommissioning and dismantling it safely. In this study, site-specific Derived Concentration Guideline Levels (DCGLs) were derived using the residual radioactivity risk evaluation tool, RESRAD-BUILD code. A conceptual model of containment building for Kori Unit 1 was set up and limited occupational worker building inspection scenario was applied. Depending on the source location, the maximum contribution source and exposure pathway of each radionuclide were analyzed. The contribution of radionuclides to dose and exposure pathways, by source location, is expected to serve as basic data in the assessment criteria of survey areas and classification of impact areas during further decommissioning and decontamination of sites.

Differentiated Thyroid Carcinoma Risk Factors in French Polynesia

  • Xhaard, Constance;Ren, Yan;Clero, Enora;Maillard, Stephane;Brindel, Pauline;Rachedi, Frederique;Boissin, Jean-Louis;Sebbag, Joseph;Shan, Larrys;Bost-Bezeaud, Frederique;Petitdidier, Patrick;Drozdovitch, Vladimir;Doyon, Francoise;Rubino, Carole;de Vathaire, Florent
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.6
    • /
    • pp.2675-2680
    • /
    • 2014
  • Background: To investigate differentiated thyroid cancer risk factors in natives of French Polynesia is of interest because of the very high incidence of this cancer in the archipelago. Materials and Methods: To assess the role of various potential risk factors of thyroid cancer in the natives of French Polynesia we performed a case-control study. The study included almost all the French Polynesians diagnosed with differentiated thyroid carcinoma between 1981 and 2003 (n=229) and 373 French Polynesian control individuals from the general population without cancer. Results: Thyroid radiation dose received from nuclear fallout before the age of 15, a personal history of neck or/and head medical irradiation, obesity, tallness, large number of children, an artificial menopause, a familial history of thyroid cancer, a low dietary iodine intake, and having a spring as the main source of drinking water were found to be significant risk factors. No roles of smoking habits, alcohol consumption, iodine containing drugs, and exposure to pesticides were evidenced. Conclusions: Except for smoking, differentiated thyroid carcinoma risk factors in natives of French Polynesia are similar to those in other populations. Our finding on the role of having a spring as a drinking water origin is coherent with some other studies and could be due to geological factors.

Lack of Association between Fingernail Selenium and Thyroid Cancer Risk: A Case-Control Study in French Polynesia

  • Ren, Yan;Kitahara, Cari Meinhold;de Gonzalez, Amy Berrington;Clero, Enora;Brindel, Pauline;Maillard, Stephane;Cote, Suzanne;Dewailly, Eric;Rachedi, Frederique;Boissin, Jean-Louis;Sebbag, Joseph;Shan, Larrys;Bost-Bezeaud, Frederique;Petitdidier, Patrick;Xhaard, Constance;Rubino, Carole;de Vathaire, Florent
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.13
    • /
    • pp.5187-5194
    • /
    • 2014
  • Background: Numerous studies have suggested that selenium deficiency may be associated with an increased risk for several types of cancer, but few have focused on thyroid cancer. Materials and Methods: We examined the association between post-diagnostic fingernail selenium levels and differentiated thyroid cancer risk in a French Polynesian matched case-control study. Conditional logistic regression models were used to estimate odds ratios and 95% confidence intervals. Results: The median selenium concentration among controls was $0.76{\mu}g/g$. Significantly, we found no association between fingernail selenium levels and thyroid cancer risk after conditioning on year of birth and sex and additionally adjusting for date of birth (highest versus lowest quartile: odds-ratio=1.12, 95% confidence interval: 0.66-1.90; p-trend=0.30). After additional adjustment for other covariates, this association remained non-significant (p-trend=0.60). When restricting the analysis to thyroid cancer of 10 mm or more, selenium in nails was non-significantly positively linked to thyroid cancer risk (p-trend=0.09). Although no significant interaction was evidenced between iodine in nails and selenium in nails effect (p=0.70), a non-significant (p-trend =0.10) positive association between selenium and thyroid cancer risk was seen in patients with less than 3 ppm of iodine in nails. The highest fingernail selenium concentration in French Polynesia was in the Marquises Islands ($M=0.87{\mu}g/g$) and in the Tuamotu-Gambier Archipelago ($M=0.86{\mu}g/g$). Conclusions: Our results do not support, among individuals with sufficient levels of selenium, that greater long-term exposure to selenium may reduce thyroid cancer risk. Because these findings are based on post-diagnostic measures, studies with prediagnostic selenium are needed for corroboration.

Liver dose reduction by deep inspiration breath hold technique in right-sided breast irradiation

  • Haji, Gunel;Nabizade, Ulviye;Kazimov, Kamal;Guliyeva, Naile;Isayev, Isa
    • Radiation Oncology Journal
    • /
    • v.37 no.4
    • /
    • pp.254-258
    • /
    • 2019
  • Purpose: Deep inspiration breath hold (DIBH) is a well-established technique that enables efficient cardiac sparing in patients with left-sided breast cancer. The aim of the current study was to determine if DIBH is effective for reducing radiation exposure of of liver and other organs at risk in right breast radiotherapy (RT). Materials and Methods: Twenty patients with right-sided breast cancer were enrolled in this study. Three-dimensional conformal RT plans were generated for each patient, with two different computed tomography scans of free breathing (FB) and DIBH. Nodes were contoured according to the Radiation Therapy Oncology Group contouring guidelines. Dose-volume histograms for the target volume coverage and organs at risk were evaluated and analyzed. Results: DIBH plans showed significant reduction in mean liver dose (5.59 ± 2.07 Gy vs. 2.54 ± 1.40 Gy; p = 0.0003), V20Gy (148.38 ± 73.05 vs. 64.19 ± 51.07 mL; p = 0.0003) and V10Gy (195.34 ± 93.57 vs. 89.81 ± 57.28 mL; p = 0.0003) volumes compared with FB plans. Right lung doses were also significantly reduced in DIBH plans. Heart and left lung doses showed small but statistically significant improvement with application of the DIBH technique. Conclusion: We report that the use of DIBH for right-sided breast cancer significantly reduces the radiation doses to the liver, lungs, and heart.

Statistical Assessment on Cancer Risks of Ionizing Radiation and Smoking Based on Poisson Models

  • Tomita, Makoto;Otake, Masanori;Moon, Sung-Ho
    • Journal of the Korean Data and Information Science Society
    • /
    • v.17 no.2
    • /
    • pp.581-598
    • /
    • 2006
  • In many epidemiological and medical studies, a number of cancer mortalities in categorical classification may be considered as having Poisson distribution with person-years at risk depending upon time. The cancer mortalities have been evaluated by additive or multiplicative models with regard to background and excess risks based on several covariances such as sex, age at the time of bombings, time at exposure, or ionizing radiation, cigarette smoking habits, duration of smoking habits, etc. An interest herein is to examine an additive, synergistic, or antagonistic relationship between radiation exposures and cigarette smoking habits for cancer mortalities. The results revealed a highly significant antagonistic in uence for cancer mortalities from all non-hematologic findings, lung and respiratory system with negative interaction between radiation exposures and cigarette smoking amounts.

  • PDF