Between August 1996 and August 1997, 22 patients underwent extracardiac Fontan operations. The basic diagnoses included univentricular heart of the right ventricular type (n=12); univentricular heart of the left ventricular type (n=4); tricuspid atresia (n=4); left isomerism, transposition of great arteries, ventricular septal defect and pulmonary stenosis (n=1); and criss-cross heart with uneven ventricle (n=1). The median age of the 14 men and 8 women was 29 months (range from 21 months to 26 years). Previous procedures included bidirectional cavopulmonary shunt (n=15, interval=15.6$\pm$3.4 months), Kawashima operation (n=4, interval=37.5$\pm$20 months), and classic Glenn shunt (n=1, interval=14 years). In 2 patients, extracardiac Fontan operations were done without any previous procedures. A 16- to 22-mm flexible Gore-Tex tube graft (n=18), Hemashield graft (n=3), or, alternatively, a nonvalved aortic allograft (n=1) was cut and anastomosed end-to-end between inferior vena cava and undersurface of pulmonary artery using Gore-Tex or Prolene suture in a running fashion. In risk Fontan patients (n=12), a communication between the extracardiac conduit and the right atrium was constructed. In the most 13 recent patients, the procedures were done without cross-clamping of the aorta and with a beating heart. Operative mortality was 9.1% (n=2). Complications included persistent chest tube drainage for more than 7 days (n=5), chorea (n=2), and low cardiac output (n=1). There were no late deaths. Follow-up echocardiogram (mean: 6 months) demonstrated satisfactory hemodynamic results in the surviving 20 patients. Potential advantages of this technique consist of minimization of surgical manipulation of atrial tissue, reduction or elimination of myocardial ischemia, creationof a uniform and stable inferior vena cava-to-pulmonary artery conduit, and increased flexibility and safety in certain high-risk patients such as those with increased pulmonary vascular resistance, pulmonary hypertension, and impaired ventricular function. Further investigations during a longer follow-up are needed to confirm the intermediate and long-term results, especially the reduction of late atrial arrhythmias.
An 8 month-old male Maltese (weighing 2.0 kg) was referred with loud heart murmur at routine physical exam in local animal clinic. Electrocardiogram found left ventricular hypertrophy pattern (4.5 mV R-wave). Diagnostic imaging studies revealed the elongation of left ventricle (LV) with classic triple bumps on the main pulmonary artery, aorta and left atrium on the ventrodorsal view of radiograph. Echocardiography revealed patent ductus arteriosus (PDA) duct and continuous turbulent shunt flow (maximal velocity 4.83 m/s) between the aorta and pulmonary artery with left to right direction. The PDA in this dog was successfully closed through femoral vein (transvenous approach) using a 5 mm Amplatz$^{(R)}$ Canine Duct Occluder. To the best of author's knowledge, this is the first case of PDA occlusion treated with Amplatz Canine Duct Occluder through femoral vein.
Kim, Ji Hyun;Kim, Sin Seung;Ha, Kyung Sun;Bae, Jungi;Park, Yonggeun
Tuberculosis and Respiratory Diseases
/
v.76
no.6
/
pp.295-298
/
2014
Pulmonary systemic arterialization to normal basal lung without sequestration is a rare congenital anomaly. In this rare abnormality, arterialization of the left lower lobe is the most common type. In general, surgical treatments have been performed. Recently, for reducing the complications and risks of surgery, embolization is mainly attempted by using coils. We report a case of 22-year-old male patient with a 10 mm anomalous arterial supply to his normal lung, which is being successfully treated by transcatheter embolization when using the Amplatzer Vascular Plug that has been adapted for the treatment of high-flows and large artery occlusions.
A 4-year-old, 6.1 kg intact female dachshund was referred to the Animal Medical Center with acute right hind limb lameness. Radiographs revealed fractures of iliac body and tibia in the right limb. In addition, the dog exhibited tricuspid valve regurgitation and moderate heartworm infection in the right ventricle and main pulmonary artery on echocardiogram. To obtain stable anesthetic conditions for operation, an adult heartworm removal procedure was previously followed by repair of the complex fractures. All surgical procedures were done without complication and with stable patient conditions. At a one month postoperative follow-up, the dog was doing well with normal ambulation and no tricuspid valve regurgitation as well.
Septic pulmonary embolism is the process in which an infected thrombus becomes detached from its site of origin and lodges in a pulmonary artery, and is usually associated with infective endocarditis, especially right-sided, or infection-associated with indwelling catheters, peripheral septic thrombophlebitis, and periodontal diseases, etc. Here, we report a case of septic pulmonary embolism associated with tricuspid valve infective endocarditis. A 23-year-old female was admitted to our hospital, due to fever, sore throat, and myalgia. In her past medical history, she had undergone a surgical operation for closure of a ventricular septal defect, but was informed that the operation resulted in an incomplete closure. The initial chest radiograph demonstrated multiple rounded, parenchymal nodules in various sizes; several nodules had central lucency suggesting cavitations. Echocardiography demonstrated a large vegetation attached to the septal tricuspid valve leaflet, extending from right ventricular inflow tract to outflow tract. Computed tomography of thorax revealed bilateral peripheral nodules and wedge-shaped consolidation at various sizes, mostly accompanied by cavitations.
Ventricular septal defect was the most common congenital Heart disease admitted to the Severance Hospital from December, 1963 to June 30. 1977. A total of 1,811 cardiac patients received cardiac catheterization in the CardiacCenter of Yonsei University Medical College. Out of the 1,811 cardiac patients, 791 cases had congenital heart disease and of these 172 cases had ventricular septal defect. This amounted to 21.7% of all those with congenital heart disease. Seventy cases of ventricular septal defect operated on in the chest surgery department are presented. Of these 70 cases of ventricular septal defect, 54 cases were male and 16 cases were female. Their ages ranged from 4/12 months to 32 years. The ratio of systolic pressure of the main pulmonary to systemic artery [Pp/Ps] for 29 of the 59 isolated ventricular septal defects was below 45 percent. Pp/Ps ratio for 19 of the 59 isolated ventricular septal defects was 75 percent. The patients were mostly below fifteen years of age. Out of 64 cases, there were 36 cases of type II defects, 20 cases of type I, 4 cases of type III , 2 cases of type IV, one case of both type II and one case of left ventricular right atrial communication. The anomalies associated with ventricular septal defect were 13 in all; 4 cases of aortic insufficiency, 3 cases of ruptured aneurysm of the sortie sinus of valsalva, 2 cases of ruptured aneurysm of the sortie sinus of valsalva with aortic insufficiency, 2 cases of patent ductus arteriosus, one case of ruptured aneurysm of the aortic sinus of valsalva with atrial septal defect [secundum type] and one case of atrial septal defect [secundum type]. Overall mortality was 8.6 percent. The mortality in pulmonary artery banding was 37.5 percent. The causes of mortality were in one case congestive heart failure, in one case asphyxia and in one case respiratory insufficiency. Tile mortality in ventricular septal defect associated with pulmonary hypertension was 7.1 percent. The cause of mortality was in one case low cardiac output syndrome. There was no mortality in the ventricular septal defects without pulmonary hypertension and mortality in the ventricular septal defect. In ventricular septal defect associated with combined anomalies, the causes mortality were in one case respiratory insufficiency and in one case congestive heart failure.
We reviewed the surgical results of intracardiac lateral tunnel Fontan procedure for the repair of functional single ventricles. Between 1990 and 1996, 104 patients underwent total cavopulmonary anastomosis. Patients' age and body weight averaged 35.9(range 10 to 173) months and 12.8(range 6.5 to 37.8) kg. Preoperative diagnoses included 18 tricuspid atresias and 53 double inlet ventricles with univentricular atrioventricular connection and 33 other complex lesions. Previous palliative operations were performed in 50 of these patients, including 37 systemic to pulmonary artery shunts, 13 pulmonary artery bandings, 15 surgical atrial septectomies, 2 arterial switch procedures, 2 resections of subaortic conus, 2 repairs of total anomalous pulmonary venous connection and 1 Damus-Stansel-Kaye procedure. In 19 patients bidirectional cavopulmonary shunt operation was performed before the Fontan procedure and in 1 patient a Kawashima procedure was required. Preoperative hemodynamics revealed a mean pulmonary artery pressure of 14.6(range 5 to 28) mmHg, a mean pulmonary vascular resistance of 2.2(range 0.4 to 6.9) wood-unit, a mean pulmonary to systemic flow ratio of 0.9(range 0.3 to 3.0), a mean ventricular end-diastolic pressure of 9.0 (range 3.0 to 21.0) mmHg, and a mean arterial oxygen saturation of 76.0(range 45.6 to 88.0)%. The operative procedure consisted of a longitudinal right atriotomy 2cm lateral to the terminal crest up to the right atrial auricle, followed by the creation of a lateral tunnel connecting the orifices of either the superior caval vein or the right atrial auricle to the inferior caval vein, using a Gore-Tex vascular graft with or without a fenestration. Concomitant procedures at the time of Fontan procedure included 22 pulmonary artery angioplasties, 21 atrial septectomies, 4 atrioventricular valve replacements or repairs, 4 corrections of anomalous pulmonary venous connection, and 3 permanent pacemaker implantations. In 31, a fenestration was created, and in 1 an adjustable communication was made in the lateral tunnel pathway. One lateral tunnel conversion was performed in a patient with recurrent intractable tachyarrhythmia 4 years after the initial atriopulmonary connection. Post-extubation hemodynamic data revealed a mean pulmonary artery pressure of 12.7(range 8 to 21) mmHg, a mean ventricular end-diastolic pressure of 7.6(range 4 to 12) mmHg, and a mean room-air arterial oxygen saturation of 89.9(range 68 to 100) %. The follow-up duration was, on average, 27(range 1 to 85) months. Post-Fontan complications included 11 prolonged pleural effusions, 8 arrhythmias, 9 chylothoraces, 5 of damage to the central nervous system, 5 infectious complications, and 4 of acute renal failure. Seven early(6.7%) and 5 late(4.8%) deaths occured. These results proved that the lateral tunnel Fontan procedure provided excellent hemodynamic improvements with acceptable mortality and morbidity for hearts with various types of functional single ventricle.
Kim, Sang Yoon;Kim, Eung Rae;Bang, Ji Hyun;Kim, Woong-Han
Journal of Chest Surgery
/
v.50
no.3
/
pp.215-219
/
2017
Pulmonary arteriovenous fistula (PAVF) is a complication of the Glenn shunt. A 57-year-old tetralogy of Fallot (TOF) patient, who had undergone a Glenn shunt and TOF total correction, complained of dyspnea and cyanosis. PAVFs were present in the rig ht lung, and rig ht lung perfusion was nearly absent. After coil embolization, takedown of the Glenn shunt, and reconstruction of the rig ht pulmonary artery, the patient's symptoms were relieved. Extrapulmonary radioisotope uptake caused by the PAVFs shown in lung perfusion scans decreased, and right lung perfusion increased gradually. Although the development and resolution of PAVFs after a Glenn shunt have been reported in the pediatric population, this may be the first report on this change in old age.
Lee, Jong Uk;Jang, Woo Sung;Lee, Young Ok;Cho, Joon Yong
Journal of Chest Surgery
/
v.49
no.2
/
pp.112-114
/
2016
The half-turned truncal switch (HTTS) operation has been reported as an alternative to the Rastelli or $r{\acute{e}}paration$$\grave{a}$$l^{\prime}{\acute{e}}tage$ ventriculaire procedures. HTTS prevents left ventricular outflow tract (LVOT) obstruction in patients with complete transposition of the great arteries (TGA) with a ventricular septal defect (VSD) and pulmonary stenosis (PS), or in those with a Taussig-Bing anomaly with PS. The advantages of the HTTS procedure are avoidance of late LVOT or right ventricular outflow tract (RVOT) obstruction, and of overstretching of the pulmonary artery. We report the case of a patient who underwent HTTS for TGA with VSD and PS, in whom there was no LVOT obstruction and only mild aortic regurgitation and mild RVOT obstruction, including observations at 12-year follow-up. Our experience with long-term follow-up of HTTS supports a solution for late complications after the Rastelli procedure.
Between February, 1983, and March, 1987, thirty-one systemic-pulmonary shunts were performed in 28 patients with cyanotic congenital heart disease. Age ranged from 8 months to 28 years [mean age, 5.4 years, Weight ranged from 7 kg to 48 kg [mean weight, 16kg]. There were 4 classic Blalock-Taussig shunts, 5 central polytetrafluoroethylene shunts, 1 aorta-right pulmonary artery shunt with graft, and 21 modified Blalock-Taussig shunts. One patient required another shunt immediately due to insufficient pulmonary blood flow with patent graft. There was no postoperative death. Conduit diameters included 4mm [2 cases], 5 mm [22 cases], and 6 mm [3 cases]. Long term follow up was available in 27 patients [96.4%] with mean period of 20 months [range, 4 months to 49 months]. The effectiveness of shunt was evaluated by cardiac catheterization with angiography [15 patients] or clinically. They showed improvement of systemic oxygen saturation values by 12% and decrease of hemoglobin by 2.3gm/dl [P<0.01]. There were 2 shunt occlusion in central shunts at 32 and 48 months respectively, and one narrowing of graft in modified Blalock-Taussig shunt at 12 months. The patency rate was 91.6% at 24 months for 5 mm grafts in modified Blalock-Taussig shunt.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.