• Title/Summary/Keyword: right lateral recumbency

Search Result 11, Processing Time 0.01 seconds

Penile Translocation Surgery in Lateral Recumbency of a Calf Using Tilt-Up Mobile (대동물 보정 차량을 이용한 횡와위 자세 육성우의 음경전위술)

  • Jeong, Jae-Kwan;Moon, Sung-Ho;Kang, Hyun-Gu;Kim, Ill-Hwa
    • Journal of Veterinary Clinics
    • /
    • v.29 no.1
    • /
    • pp.112-117
    • /
    • 2012
  • This report evaluated the convenience and accessibility of a penile translocation surgery in the lateral recumbency of a calf using a tilt-up mobile compared with that of dorsal recumbency on the ground of a barn. One nine-month-old F-1 (Korean native sire x Holstein dam) calf was sedated with xylazine (0.03 mg/kg, IV) and restrained in the right lateral recumbency position on a tilt-up restraint mobile (90 cm high), whereas the other nine-month-old Korean native calf was administered xylazine (0.3 mg/kg, IV) and restrained in dorsal recumbency position on the ground of a barn, with assistance by one person. For the two calves, lidocaine was administered subcutaneously from the preputial orifice to the S-shaped penis. The preputial orifice was incised, and the preputial sheath and penis were separated bluntly, then laterally translocated to the site toward the left flank at a $40^{\circ}$ angle. Anti-inflammatory drug (ketoprofen) and antibiotics (penicillin) were administered following the surgery. The duration of surgery was 30 min shorter in the calf that received the surgery in lateral recumbency using the tilt-up mobile with operator's standing posture (60 min) than the one that underwent surgery in dorsal recumbency on the ground with operator's bending posture (90 min). One week after the surgery, the operation area, including the translocated preputial orifice, was healed without complications in both cases. The results detailed in this report demonstrate that penile translocation surgery in the lateral recumbency position using a tilt-up mobile might be used conveniently in calves due to the convenience of restraint, reduced surgery time, and reduced physical inconvenience for the surgeon.

Correlation of Temporary Lateral Recumbency and Lung Opacity on Ventrodorsal Radiograph (일시적인 횡와 자세와 흉와위 영상에서 폐 불투과도의 상관관계)

  • Lee, Hyunjik;Jeong, Jiyoon;Choi, Wooshin;Lee, Donghoon;Lee, Youngjae;Chang, Jinhwa;Chang, Dongwoo
    • Journal of Veterinary Clinics
    • /
    • v.32 no.4
    • /
    • pp.313-318
    • /
    • 2015
  • The lung opacity on radiography is influenced by various factors. The physical density of the lung and the attenuation ensured on computed tomography (CT) scans is determined by three components : lung tissue, blood, and air. Temporary right lateral recumbency may responsible for the increase of opacity on ventrodorsal projection view. Thus, our aim is to demonstrate that the effect of right lateral recumbency posture on right lung opacity using radiograph and CT scan. In this study, 62 dogs without clinical or radiologic signs of cardiopulmonary disease are selected. Thorax radiographs per 30 seconds for 2 minutes (30s, 60s, 90s, 120s) were performed for 62 dogs. After discussion of the radiographic findings of lung field by two radiologists and a student at Chungbuk national university veterinary medical center a consensus opinion was recorded. Computed tomography per a minute (1 min, 2 min) for 2 minutes were performed for 2 dogs. Mean x-ray attenuation of lung was measured quantitatively using software at two levels (aortic arch and basal level). Among 62 dogs with radiograph comparison, 9.3% of dogs showed influence by postural effect. However, all 2 dogs with computed tomography comparison, showed influence by postural effect. In conclusion, position dependent changes of lung density in CT exam are not consistent with thoracic radiograph.

Comparison for Radiographic Measurements of Canine Liver Size by Left and Right Recumbency

  • Kim, Sung-yong;Yoon, Young-min;Hwang, Tae-sung;Shin, Chang-ho;Lim, Jong-su;Yeon, Seong-chan;Lee, Hee-chun
    • Journal of Veterinary Clinics
    • /
    • v.35 no.1
    • /
    • pp.13-16
    • /
    • 2018
  • Liver size is one of the important standards used to establish differential diagnoses for dogs with suspected hepatic diseases. No previous reports have been reported about comparison for radiographic measurements of canine liver size by left and right recumbency. The retrospective study was performed in dogs that underwent abdominal radiography with left, right and dorsal recumbency at the Veterinary Teaching Hospital of Gyeongsang National University from March 6, 2014 to December 31, 2014. We investigated differences of radiographic liver size according to direction of lateral recumbency. We found differences of radiographic measurements in canine liver size between left and right recumbency. Thus, positional effect should be considered in case of monitoring the canine liver size regularly.

Assessment of Computed Tomographic Lung Density in Beagle and Shihtzu Dogs : Influence of Position and Positive End Expiratory Pressure (비글과 시츄견에서 호기말 양압에 따른 전산화 단층촬영상의 폐밀도의 평가)

  • Kim, Tae-Hun;Chang, Jin-Hwa;Yun, Seok-Ju;Yoon, Jung-Hee;Chang, Dong-Woo
    • Journal of Veterinary Clinics
    • /
    • v.27 no.3
    • /
    • pp.273-283
    • /
    • 2010
  • The objective of this study was to measure densities in various areas of the normal canine lung with computed tomography (CT) depending on influences of gravity and the degree of lung inflation and to determine optimal positions and positive end expiratory pressure of canine lung for CT scanning. In each eight normal Beagle and Shihtzu dogs, a respiratory breathhold maneuver without spontaenous breathing at different positive end expiratory pressure (PEEP) of 0 mmHg, 10 mmHg and 20 mmHg was applied with the position of right and left lateral recumbency, sternal recumbency, and dorsal recumbency and spiral-CT scans of the total lung were acquired. Slices were selected at three levels through the apex, middle and basal lung at the aortic arch, carina and just above the diaphragm and lung density was measured in the dorsal, ventral, and lateral portions of the peripheral lung field. Lung density in dependent areas was higher than in nondependent areas (p < 0.05) regardless of species, positions, anatomic locations at the PEEP of 0 mmHg and 10 mmHg. However, no significant difference of lung density was found at PEEP of 20 mmHg in both species except the dorsal recumbency in Shihtzu dogs. This density gradient in the dependent areas is strongly influenced by PEEP (p < 0.05). In the four positions on the CT gantry, the lung density at the dependent and nondependent location of the lung was greater at the aortic arch than at the base (p < 0.05). Lung density decreased on identical location according to increase of PEEP (p < 0.05). There was no significant difference between right and left lung density at sternal and dorsal recumbency and no significant difference of the dorsal, ventral, and lateral portions of lung density at the right and left recumbency under identical pressure. It is implied that during chest CT scan with 20 mmHg of positive end expiratory pressure with right or left lateral recumbency, canine lung density do not influenced by gravity or anatomic location.

Evaluation of Total Lung Volume and Density using Multi-Detector Computed Tomography in Normal Dogs (정상견에서 다중채널 컴퓨터단층촬영술을 통한 폐용적과 밀도의 평가)

  • Choi, Ho-Jung;Lee, Ki-Ja;Choi, Soo-Young;Lee, Jung-Woo;Han, Woo-Sok;Lee, In;Kwon, Young-Hang;Lee, Young-Won
    • Journal of Veterinary Clinics
    • /
    • v.28 no.5
    • /
    • pp.510-515
    • /
    • 2011
  • This study was performed to quantitatively assess the normal lung volume and density according to the position by multi-detector computed tomography (MDCT) in dogs. Helical CT of the thorax was performed on 4 different positions with dorsal, left lateral, right lateral and ventral recumbency in 6 Pekingese and 6 Maltese dogs. During CT scanning, dogs were kept hyperventilated. Through the 3-dimensional reconstruction of CT images, the lung parameters were measured as the volume and density of the left, right including accessory lobe, and total lung. 3D images represented the different lung shape between Pekingese and Maltese dogs. Their difference of total lung volume and total lung density was not significant on the each position in both breeds. Right lung volume was significantly higher than left. The difference of left and right volume was $66.91{\pm}25.1$ ml. Linear relationship was shown between body weight and lung volume of ventral recumbency position. The dependent lung had higher density and lower volume than nondependent lung in both breed dogs. The volume of nondependent lung was not changed compared with the volume on ventral or dorsal recumbency. The total lung volume measured with MDCT is correlated with the lung density, and the lung density is useful to predict the normal total lung volume.

Assessment of Abdominal Organs Movement by Respiration Using Computed Tomography in Dogs: A Pitfall for Radiation Therapy

  • Ah Reum Kim;Soyon An;Gunha Hwang;Moonyeong Choi;Tae Sung Hwang;Hee Chun Lee
    • Journal of Veterinary Clinics
    • /
    • v.40 no.2
    • /
    • pp.104-112
    • /
    • 2023
  • The change in the position of the abdominal organs due to movement by respiration is one of the reasons behind inaccurate irradiation of organs during radiotherapy (RT). Although studies in human medicine have revealed on the respiratory movements of abdominal organs, there is little information and no reference data for dogs. The purpose of this study was to establish the reference values of abdominal organs movement in various postures using computed tomography (CT), and to compare the movements of organs between dorsal recumbency and ventral, right and left lateral recumbency during respiration. CT images for kidney, adrenal gland, medial iliac lymph node, urinary bladder, gallbladder, liver, stomach, and thoracic and lumbar vertebral body of five beagle dogs were acquired. The movements of organs were evaluated by comparing the end-expiratory and end-inspiratory images. Movements of the organs were evaluated by dividing it into right-to-left, dorsal-to-ventral, and cranial-to-caudal directions. The movements of abdominal organs according to the change in postures and respiration were establish. The movement of the bilateral organs was the least when the organs were in the downward position (p < 0.017). The movement of cranial-to-caudal direction was greater than the movement of the other directions in most of the organs. Data obtained in this study may be useful in selecting the appropriate posture that can reduce the movements of organs to be treated with RT, and the data could be useful for setting the planning target volume to consider the movements of the abdominal organs by respiration.

Ultrasonography of the Kidney and Urinary Bladder in Male Korean Native Goat (웅성 한국재래산양에서 신장 및 방광의 초음파검사법)

  • Kim Myung-Cheol;Jun Moo-Hyung
    • Journal of Veterinary Clinics
    • /
    • v.10 no.2
    • /
    • pp.199-202
    • /
    • 1993
  • The purpose of this study was to make fundamental ultrasonographic observations of kidney and urinary bladder in Korean native goat. The position, dimensions, and structure of the kidneys and bladders In 7 male Korean native goats were determinded by use of ultrasonography. A 3.5%.MHz linear transducer was used. All examinations were performed on goats in lateral recumbency under sedation. The left kidney was 4.2 to 5.9 cm long, 2.5 to 3.6 cm wide, and 2.4 to 3.2 cm deep. Diameter of the parenchyma and renal sinus of the left kidney ranged between 0.7 and 1.3 cm and 0.7 and 1.4 cm, respectively. Circumferences of the medullary Pyramids varied between 1.3 and 1.9 cm. Similar ultrasonic measurements were obtained for the right kidney. The diameter of the urinary bladder varied between 2.1 and 5.4 cm in the goats. It was concluded that the ultrasonographic findings described in this study can be used as references for diagnosis of morphologic changes in the kidney and urinary bladder of Korean native goat.

  • PDF

Echocardiographic evaluation of heart failure in dogs with myxomatous mitral valve disease: a retrospective study

  • Han, Donghyun;Lee, Dong-Guk;Jung, Dong-In
    • Journal of Biomedical and Translational Research
    • /
    • v.19 no.4
    • /
    • pp.79-85
    • /
    • 2018
  • Echocardiography is one of the most useful diagnostic techniques for differentiating heart disease as well as mitral valve lesion. Forty client-owned small breed dogs (weight, 2.3-13.2 kg) aged between 8-17 years with myxomatous mitral valve degeneration (MMVD) were included in the present study. The diagnosis of MMVD in dogs was made based on the clinical signs, chest radiography data, and echocardiographic findings. Echocardiographic examinations were conducted in accordance with recommended standards for dogs. M-mode, Doppler, and 2D echocardiography were performed in left and right lateral recumbency. 2D echocardiography was used to measure LA and Ao diameter from 2D short axis at the level of the aortic valve. In the comparison of conventional echocardiography indices in dogs with different stages of heart failure with MMVD, significant differences were observed in E/A ratio (p=0.005), EDV (p<0.001), EDVI (p<0.001), E-peak velocity (p= 0.001), ESV (p=0.028), ESVI (p=0.004), LA (p<0.001), LA/Ao Ratio (p<0.001), LVIDd (p<0.001), LVIDd/Ao Ratio (p<0.001), LVIDs (p=0.036), LVIDs/Ao Ratio (p=0.002), and MR Velocity (p=0.026). In addition, distinct correlations were found in EDV (r=0.712), LA/Ao ration (r=0.830), LVIDd (r=0.724), and LVIDd/Ao ratio (r=0.759). This study found that known conventional echocardiographic indices, including EDV, LA/Ao ratio, LVIDd dimension, and LVIDd/Ao ratio correlated with the severity of MMVD in point of significant differences and distinct correlations.

Laparoscopic Splenectomy in Two Dogs Using SonicisionTM

  • Park, Tae-Yeong;Kim, Hyun-Jin;Kim, Jung-Hoon;Kim, Jun-Min;Seok, Seong-Hoon;Jung, Dong-In;Hong, Il-Hwa;Lee, Hee-Chun;Yeon, Seong-Chan
    • Journal of Veterinary Clinics
    • /
    • v.33 no.4
    • /
    • pp.214-217
    • /
    • 2016
  • A 10-year-old, 24.1 kg, intact female Siberian husky dog (case 1) and 11-year-old, 5.0 kg, intact male Shihtzu dog (case 2) presented with chief complaints of polydipsia, anorexia, vomiting and exercise intolerance (case 1) and stranguria (case 2). Splenic nodule (case 1) and mass (case 2) were identified in these patients through ultrasonographic examination. Laparoscopic splenectomy was conducted for the histopathologic evaluation. In addition, laparoscopic ovariohysterectomy, liver biopsy (case 1) and castration (case 2) were performed for treatment or diagnosis of primary symptoms. Under general anesthesia, 5 mm three-portal access laparoscopic splenectomy was performed using the Sonicision$^{TM}$ equipment. The dogs were rotated onto right lateral recumbency. The spleen was elevated using a fan or goldfinger retractor, which revealed the ventral aspect of the spleen. Resection of vessels was started at the caudal aspect of the spleen using the Sonicision$^{TM}$. The excised spleen was removed from the abdominal cavity using a 12 mm endo-bag via the enlarged instrument portal. There were no post-operative complications in either patient. Histopathologic diagnoses were splenic lymphoid hyperplasia (case 1) and splenic nodular hyperplasia (case 2). Based on our experience, laparoscopic splenectomy is sufficient to replace traditional splenectomy in small animal surgery. The use of the Sonicision$^{TM}$ could be a novel surgical technique for three-portal laparoscopic splenectomy, regardless of patient size.

A Comparison of Two Intramuscular Doses of a Xylazine-Diazepam-Ketamine Combination in Dogs (개에서 Xylazine-diazepam-ketamine 병용마취 시 두 가지 근육내 투여 용량 비교)

  • Lee, Jae-Yeon;Seo, Ji-Won;Cho, Jae-Geum;Cho, Ha-Eun;Jeong, Seong-Mok;Kim, Myung-Cheol
    • Journal of Veterinary Clinics
    • /
    • v.29 no.1
    • /
    • pp.12-17
    • /
    • 2012
  • Many drugs are administered intramuscularly to immobilize and anesthetize dogs. There are many established intramuscular (IM) anesthetic combinations for dogs; however, little information is available on the effects of a xylazinediazepam-ketamine (XDK) combination. The purpose of this study was to investigate the anesthetic effects of the XDK combination in dogs. Twelve adult mixed bred dogs were used. All dogs were anesthetized with an IM injection of diazepam (0.5 mg/kg) and xylazine (1.1 mg/kg) with low-dose ketamine (5 mg/kg; group 1) or high-dose ketamine (10 mg/kg; group 2) in one syringe. After administration of the test dose, the animals were positioned in a right lateral recumbency, and analgesia and cardiopulmonary data were collected and recorded. The duration of anesthesia in group 2 was significantly longer than that of group 1 (mean [sd] 68.0 [7.6] v 51.3 [2.7] minutes). Blood pressure increased significantly after XDK administration in both groups, and $S_aO_2$ levels decreased significantly from baseline at 10, 20, and 30 minutes in both groups. XDK administration produced satisfactory sedation and analgesia in all dogs. In conclusion, intramuscular administration of xylazine-diazepam-ketamine combination at a doses of 1.1 mg/kg xylazine, 0.5 mg/kg diazepam, and 5 or 10 mg/kg ketamine appeared to be effective short duration anesthetic protocols in dogs.