• Title/Summary/Keyword: rial Lens

Search Result 2, Processing Time 0.019 seconds

Development of a Sensor Calibration to Enhance the Performance of a Non-contact Laser Optical Sensor Unit (비접촉 레이저 광센서의 성능 향상을 위한 센서보정에 관한 연구)

  • Seo, Pyeong-Won;Ryu, Young-Kee;Oh, Choon-Suk;Byun, Jong-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2006.10c
    • /
    • pp.579-581
    • /
    • 2006
  • Flat panel image display devices such as TFT LCD and PDP have required more large area and high quality control components. To control the qualities of the components, measurements of the flatness of a plate glass has been required. In order to measure the shape of the specular objects, Non-Contact Optical Sensor using Hologram laser unit was proposed. The sensor has a optical system that is composed of a Hologram laser and objective lens. The temperature of the sensor body is controlled by TEC(Thermoelectric Cooler) to maintain the same wavelength of the diode laser. In this research, we proposed the calibration scheme to make sensor real time measuring sensor. From the experimental results we see that the proposed sensor unit can measure the position of the glass surface in rial time.

  • PDF

The Necessity and Requirement of Trial Lens Set Standardization (검안렌즈 표준화의 필요성과 규격에 관한 연구)

  • Park, Sang-Yeul
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.3
    • /
    • pp.217-223
    • /
    • 2006
  • The purpose of this study is to provide improvements and standards of trial lens, in a situation that there is a lack of standards of trial lens set that have been used for self-conscious refraction test after helm refraction test at about 5,000 opticians, ophthalmologic clinics and hospitals, and contact-lens shops, that there is a lot of discrepancies between refraction specified and the actual power, and that there is no regulation of optical tolerance error. For the study, opticians who have used Trial lens set were asked to participate in a questionnaire survey through continuing education, and divided into those who have used domestic lens and those who have used imported lens, 5 opticians each for less than 5 years, 5 to 10 years, more than 10 years. The measurement of both refraction specified and the actual diopter was compared to Japan Industrial Standards(JIS T4402). As a result of comparative analysis, more than 80% of respondents have had reliability on the refraction of trial lens they had used, indicating that they have never measured the refraction specified and the actual diopter after buying them. Besides, Korean Industrial Standards(KS P4402) has been imperfect in diopter range since it was legislated in 1979. More than 95% of respondents have been unsatisfied with optometry. Also, it has indicated that refraction error is more frequent in long-term-used trial lens. The conclusion is that it is necessary to standardize trial lens set and that it is required to add lens to lens set provided under KS P4402. Moreover, it is necessary to have supervisory agency for a standardization of trial lens. I hope that both domestic lens and imported lens, as in German and Japan, will be tested to find whether they meet optical tolerance error and standard trial lens will be distributed. Good optic inspection is required for the improvement and management of eye health and optical function, and the same standard trial lens set should be used. whoever is tested. Also, I hope that trial lens set will be specified within standards and tolerance error.

  • PDF